Features

  • Lasing Mode Structure: single mode
  • Peak Wavelength : typ. 1430 nm
  • Optical Ouput Power: 3 mW, CW
  • Package: 5.6 mm, flat window Absolute Maximum Ratings (TC=15°C) Item Symbol Value Unit CW Output Power PO 20 mW LD Reverse Voltage Vr 2 V LD Forward Current Iop 150 mA PD Reverse Voltage VrPD 20 V PD Forward Current IPD 10 mA Operating Case Temperature TC -40 … +60 °C Storage Temperature Tstg -40 … +85 °C Specifications (TC=15°C) Item Conditions Symbol Min. Typ. Max. Unit Optical Specifications CW Output Power -40 .. +60 °C PO 3 - - mW 25°C, PO=3mW 1420 1430 1450 Center Wavelength -40..60°C, PO=3mW λC 1400 - 1470 nm Spectral Width 25°C, PO=3mW Δλ - 0.9 4 nm Wavelength Temp. Coefficient -40..60°C, PO=3mW Δλ / ΔT - 0.5 - nm/K Θ║ - 21 - deg. FWHM Beam Divergence 25°C, PO=3mW Θ┴ - 36 - deg. 25°C, Iop= Ith +16mA 4 7 - Modulation Bandwidth 60°C, Iop= Ith +16mA f-3dB 2 6 - GHz 25°C, Iop= Ith +16mA - 5 - Resonance Frequency 60°C, Iop= Ith +16mA fr - 4 - GHz Electrical Specifications 25 °C - 12 18 Threshold Current 60 °C Ith - 19 33 mA 25°C, PO=3mW - 21 40 Operating Current 60°C, PO=3mW Iop - 29 60 mA 25°C, PO=3mW 0.16 0.32 - Slope Efficiency 60°C, PO=3mW η 0.12 0.29 - W/A Operating Voltage 25°C, PO=3mW V op - 1.1 1.6 V Serial resistance 25°C, PO=3mW R S - 6 - Ω Monitor Current 25°C, PO=3mW I m 100 250 700 µA Monitor Dark Current 25°C, VRPD=5V I d - 0.1 1.0 µA Monito Capacitance F=1MHz, VRPD=5V C m - 5 10 pF The above specifications are for reference purpose only and subjected to change without prior notice.

13.09.2011 LD1430-C003 2 of 4

5.6 mm Package (Unit:mm) Bottom View PIN Funciton

1 Case, LD Anode

2 PD Anode

3 PD Cathode

4 LD Cathode

13.09.2011 LD1430-C003 3 of 4

Typical Performance Curves

13.09.2011 LD1430-C003 4 of 4

  • Laser Light can damage the human eyes and skin. Do not expose the eye or skin directly to any laser light and/or through optical lens. When handling the LDs, wear appropriate safety glasses to prevent laser light, even any reflections from entering to the eye. Focused laser beam through optical instruments will increase the chance of eye hazard.
  • The LD emitts invisible light Cautions 1. Operating methode
  • This LD shall change its forward voltage requirement and optical ouput power according to temperature change. Also, the LD will require more operation current to maintain same ouput power as it degrades. In order to maintain output power, use of APC (Automatic Power Control) is recommended. Which use monitor feedback to adjust the operation current.
  • Confirm that electrical spike current generated by switching on and off does not exceed the maximum operating current level specified her ein above as absolute maximum rating. Also, employ appropriat countermeasures to reduce chattering and/or overshooting in the circuit. 2. Static Electricity
  • Static electricity or electrical surges will reduce and degrade the reliability of the LDs. It is recommended to use a wrist trap or anti-electrostatic glove when handeling the product. 3. Absolute Maximum Rating
  • Active layer of LDs shall have high current density and generate high electric field during its operation. In order to prevent excessive dam age, the LD must be operated striclty below absolute maximum rating.