LCW50 XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

  • 50W convection cooled
  • Integrated connector cover
  • ITE, industrial & household approvals
  • Class B conducted & radiated emissions
  • Input voltage range 85-305VAC
  • Regulated single outputs from 5.0V to 48VDC
  • Output voltage trim ±10%
  • Efficiency to 90%
  • Short circuit, overvoltage & overload protection
  • Conformal coating option
  • -30°C to +70°C operating temperature
  • 3 year warranty Technology Industrial Electronics Robotics Instrumentation

Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 4.5 52.8 VDC See Models & Ratings table % Full load LCW50US05 ±1 All other models Voltage Adjustment ±10 % Minimum Load 0 A No minimum load required Start Up Delay 58 130 ms 115VAC full load 60 138 230VAC full load Hold Up Time ms 115VAC 30 230VAC Drift ±0.03 % After 20 minutes warm up, 230VAC, 0°C to 50°C Line Regulation ±0.5 % 100-264VAC, full load Load Regulation ±1.0 % 0-100% load LCW50US05 ±0.5 All other models Transient Response 10 % Recovery within 1% in less than 5ms for a 50-75% and 75-50% load step Ripple & Noise mV pk-pk See Models & Ratings table Over/Undershoot 10 % Full load 5ms recovery Overvoltage Protection 6.3 LCW50US05 Hiccup mode, auto recovery

16.2 LCW50US12

21.75 LCW50US15

33.6 LCW50US24

49.0 LCW50US36

60.0 LCW50US48

Overload Protection 110 200 % Nominal output current, auto recovery Temperature Coefficient ±0.03 5 %/°C Short Circuit Protection Continuous, hiccup with auto recovery Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 115/230 305 VAC Derate output power linearly from 100% at 100VAC to 80% at 85VAC and from 100% at 277VAC to 80% at 305VAC 120 430 VDC Alternative input. Not to be used in addition to AC input. DC input not included in safety approvals, external DC rated fuse required. Derate output power linearly from 100% at 120VDC to 80% at 100VDC and from 100% at 390VDC to 80% at 430VDC Input Frequency 47 50/60 63 Hz Input Current - Full Load 1.2 A 115VAC 0.8 230VAC No Load Input Power 0.5 W Inrush Current A 115VAC cold start at 25°C ambient 60 230VAC cold start at 25°C ambient Earth Leakage Current 0.75 mA 277VAC/50Hz (T yp) Input Protection T3.15A/300VAC Internal fuse fitted in line

Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 88 % 230VAC Full load (see Models & Ratings table) Isolation: Input to Output Input to Ground Output to Ground

4000 VAC

Class I construction2000 VAC

1250 VAC

Switching Frequency 65 kHz Power Density 3.60 W/in3 Mean Time Between Failure 300 khrs MIL-HDBK-217F , Notice 2 25°C GB Weight 0.418 (190.0) lb(g) Case Material Aluminium chassis with vented galvanized steel cover Conformal Coating Option Acrylic resin, UL94V-0 rated, certified (UL No. E351072), minimum 30μm coating thickness. Add suffix -E to part number Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -30 +70 °C See derating curve Storage Temperature -40 +85 °C Cooling Natural convection Humidity 5 90 %RH Non-condensing Operating Altitude 5000 m Shock and Vibration T ested according to EN60068-2-27 , 10 - 500Hz, 5g (1H) for each X, Y and Z plane EMC: Immunity Phenomenon Standard T est Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 3 A Contact ±6kV/Air ±8kV Radiated Immunity EN61000-4-3 3 A 10V/m EFT EN61000-4-4 3 A ±2kV Surge EN61000-4-5 Installation class 4 A Line to line ±1kV , line to ground ±2kV Conducted EN61000-4-6 3 A 10Vrms Dips EN61000-4-11 Dip. 100% (0VAC), 10ms A Dip. 100% (0VAC), 20ms B Dip. 60% (88VAC), 200ms A Dip. 30% (154VAC), 500ms A Dip. 20% (176VAC), 5000ms A Interruptions Int. 100% (0VAC), 5000ms B EMC: Emissions Phenomenon Standard T est Level Notes & Conditions Conducted EN55032 Class B Radiated EN55032 Class B

Certification Standard Notes & Conditions UL UL62368-1 Information T echnology EN EN62368-1, EN60335, EN61558 Information T echnology and Household CE Meets all applicable directives UKCA Meets all applicable legislation AC-DC POWER SUPPLIESLCW50 Series T emperature Derating Application Notes -30 -10 10 20 30 40 500 Ambient temperature (°C) 100 Output power (%) 60 70-20 (5V at <165VAC input) (5V at >165VAC input, 12V, 15V, 24V, 36V, 48V)

3.642 (92.5) NOTES: UNITS: mm [inch] PIN SECTION TOLERANCES: 0.10 [ 0.004] TOLERANCES: 1 DECIMAL PLACE 1.00 [ 0.039] 2 DECIMAL PLACES 0.50 [ 0.020] 0.374 (9.5) Pitch (Typ.) ‘ON’ LED Adj. 0.256 (6.5) 3.543 (90.0) Ø0.138 (3.5) 1.024 (26.0) 2 x 0.591 (15.0) 2.913 (74.0) 0.394 (10.0) 0.571 (14.5) 0.138 (3.5) 2 x M3 x 0.5 Thread Max. penetration = 5mm 2.165 (55.0) 0.807 (20.5) 2 x 1.594 (40.5) Max. penetration = 3mm 2 x M3 x 1.181 (30.0) 3.228 (82.0) 0.319 (8.1) Typ.

0.5 Thread

3.898 (99.0) 0.138 (3.5) Lorem ipsum Power V out 1. All dimensions are in inches (mm). 2. Tightening torque: M3.5, 0.4Nm fixings 3. General tolerances: ±0.039 (±1.00) 4. Chassis must be connected to protective earth. 5. Use 22-14 AWG wire range for connector Notes:

03 Sept 2021

1 AC(L)

2 AC(N)

3 GND

Connector torque: M3.5, 0.4Nm