Features

  • 320W fan cooled
  • Active PFC
  • Integrated connector cover
  • ITE & industrial approvals
  • Class B conducted & radiated emissions
  • Input voltage range 85-305VAC
  • Regulated single outputs from 5.0V to 48VDC
  • Output voltage trim
  • Efficiency to 89%
  • Short circuit, overvoltage & overload protection
  • Conformal coating option
  • -30°C to +70°C operating temperature
  • 3 year warranty TechnologyIndustrial Electronics RoboticsInstrumentation

Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 4.5 56 VDC See Models & Ratings table Initial Set Accuracy % Full load LCW320PS05 ±1 All other models Voltage Adjustment ±10 % Minimum Load 0 A No minimum load required Start Up Delay 0.3 1.4 s 115/230VAC full load Hold Up Time 12 ms 115/230VAC Drift ±0.03 % After 20 minutes warm up, 230VAC, 0°C to 50°C Line Regulation ±0.5 % Full load LCW320PS05 ±0.3 LCW320PS12/15 ±0.2 LCW320PS24/48 Load Regulation % 0-100% load LCW320PS05 ±0.5 All other models Transient Response 10 % Recovery within 1% in less than 5ms for a 50-75% and 75-50% load step Ripple & Noise mV pk-pk See Models & Ratings table Over/Undershoot 10 % Full load Overvoltage Protection 7. 0 VDC LCW320PS05 Auto recovery, hiccup mode

16.2 LCW320PS12

21.8 LCW320PS15

32.4 LCW320PS24

60.0 LCW320PS48

Overload Protection 105 150 % Nominal output current, hiccup with auto recovery Temperature Coefficient ±0.03 %/°C Short Circuit Protection Continuous hiccup with auto recovery Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 115/230 305 VAC Derate output power linearly from 100% at 100VAC to 80% at 85VAC 120 430 VDC Alternative input. Not to be used in addition to AC input. DC input not included in safety approvals, external DC rated fuse required. Derate output power linearly from 100% at 140VDC to 80% at 120VDC Input Frequency 47 50/60 63 Hz Power Factor 0.98 115VAC at full load 0.95 230VAC at full load Input Current - Full Load 4.0 A 115VAC 2.0 230VAC No Load Input Power 0.3 W Inrush Current A 115VAC cold start at 25°C ambient 65 230VAC cold start at 25°C ambient Earth Leakage Current 2.0 mA 305VAC Input Protection T6.3A/300VAC Internal fuse fitted in line

Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -30 +70 °C See derating curve Overtemperature Protection Hiccup mode with auto recovery, temperature measured internally Storage Temperature -40 +85 °C Cooling Fan cooled, automatic operation Humidity 5 90 %RH Non-condensing Operating Altitude 5000 m Derate output linearly from 2000m to 85% at 5000m Shock and Vibration T ested according to EN60068-2-27 , 10 - 500Hz, 5g (1H) for each X, Y and Z plane EMC: Emissions Phenomenon Standard T est Level Notes & Conditions Conducted EN55032 Class B Radiated EN55032 Class B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 88 % 230VAC Full load (see Models & Ratings table) Isolation: Input to Output Input to Ground Output to Ground

4000 VAC

Class I construction2000 VAC

500 VAC

Switching Frequency 65 kHz Power Density 7 .07 W/in3 Mean Time Between Failure 250 khrs MIL-HDBK-217F , Notice 2 25°C GB Weight 1.65 (750) lb(g) Case Material Aluminium chassis with vented galvanized steel cover (AL1100 and SGCC) Conformal Coating Option Acrylic resin, UL94V-0 rated, certified (UL No. E351072), minimum 30μm coating thickness. Add suffix -E to part number

EMC: Immunity Phenomenon Standard T est Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 3 A Contact ±6kV / Air ±8kV Radiated Immunity EN61000-4-3 3 A 10V/m EFT EN61000-4-4 3 A ±2kV Surge EN61000-4-5 Installation class 3 A Line to line ±1kV , line to ground ±2kV Conducted EN61000-4-6 3 A 10Vrms Dips EN61000-4-11 Dip. 100% (0VAC), 10ms A Dip. 100% (0VAC), 20ms B Dip. 60% (88VAC), 200ms A Dip. 30% (154VAC), 500ms A Dip. 20% (176VAC), 5000ms A Interruptions Int. 100% (0VAC), 5000ms B Safety Approvals Certification Standard Notes & Conditions UL UL62368-1 Information T echnology TUV EN62368-1 Information T echnology CE Meets all applicable directives UKCA Meets all applicable legislation AC-DC POWER SUPPLIESLCW320 Series

-30 -10 10 20 30 40 500 Ambient temperature (°C) 100 Output power (%) 60 70-20 LCW320 Series AC-DC POWER SUPPLIES

‘ON’ LED V Out Adj. 2x M4x0.7 Thread - Both Sides Max. Penetration = 5mm 4x M4x0.7 Thread Max. Penetration = 3mm Pitch (Typ.) Typ. < Pin 1 < Pin 9 LCW320-C 1.181 (30.0) 8.465 (215.0) 1.868 (47.5) 1.280 (32.5) 5.906 (150.0) 2x 5.906 (150.0) 2x 1.280 (32.5) 0.323 (8.2) 0.374 (9.5) 4.528 (115.0) 1.445 (36.7) Air Flow 1. All dimensions are in inches (mm). 3. General tolerances: ±0.039 (±1.00) 4. Chassis must be connected to protective earth. Notes:

12 Aug 2021

7 GND

8 AC(N)

9 AC(L)

Connector torque: M3.5, 0.8Nm