Features
- 150W convection cooled
- ITE, industrial & household approvals
- Integrated connector cover
- Class B conducted & radiated emissions
- Input voltage range 85-264VAC
- 300VAC withstand voltage for 5s
- Output voltages from 12V to 48VDC
- Output voltage trim ±10%
- Efficiency to 89%
- Short circuit, overvoltage & overload protection
- Conformal coating option
- -30°C to +70°C operating temperature
- 3 year warranty
Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 10.8 52.8 VDC See Models & Ratings table Initial Set Accuracy ±1 % Full load Voltage Adjustment ±10 % Minimum Load 0 A No minimum load required Start Up Delay 200 ms Full load Hold Up Time ms 115VAC 16 230VAC Line Regulation ±0.5 % 100-264VAC, full load Load Regulation ±0.5 % 0-100% load Transient Response 10 % Recovery within 1% in less than 5ms for a 50-75% and 75-50% load step Ripple & Noise mV pk-pk See Models & Ratings table Over/Undershoot 10 % Full load, 5ms recovery Overvoltage Protection
16.2 VDC LCS150US12
Cycle input voltage to restart
21.7 LCS150US15
33.6 LCS150US24
48.6 LCS150US36
60.0 LCS150US48
Overload Protection 110 150 % Nominal output current, auto recovery Temperature Coefficient ±0.03 %/°C Short Circuit Protection Continuous, hiccup with auto recovery Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 115/230 264 VAC Derate output power linearly from 100% at 100VAC to 80% at 85VAC 120 370 VDC Alternative input. Not to be used in addition to AC input. DC input not included in safety approvals, external DC rated fuse required. Derate output power linearly from 100% at 140VDC to 80% at 120VDC Input Frequency 47 50/60 63 Hz Surge Withstand 300VAC for maximum 5s Input Current - Full Load 4.0 A 115VAC 2.0 230VAC No Load Input Power 0.5 W Inrush Current A 115VAC cold start at 25°C ambient 60 230VAC cold start at 25°C ambient Earth Leakage Current 0.75 mA 230VAC/50Hz Input Protection T6.3A/250VAC Internal fuse fitted in line
Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 88 % 230VAC Full load (see Models & Ratings table) Isolation: Input to Output Input to Ground Output to Ground
4000 VAC
Class I construction2000 VAC
1250 VAC
Switching Frequency 65 kHz Power Density 5.5 W/in3 Mean Time Between Failure 300 khrs MIL-HDBK-217F , Notice 2 +25°C GB Weight 0.9 (410) lb(g) Case Material Aluminium chassis with vented galvanized steel cover Conformal Coating Option Acrylic resin, UL94V-0 rated, certified (UL No. E351072), minimum 30μm coating thickness. Add suffix -E to part number Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -30 +70 °C See derating curve Overtemperature Protection Output disabled, auto recovery. T emperature measured internally Storage Temperature -40 +85 °C Cooling Natural convection Humidity 5 90 %RH Non-condensing Operating Altitude 5000 m Shock and Vibration T ested according to EN60068-2-27 , 10 - 500Hz, 5g (1H) for each X, Y and Z plane EMC: Emissions Phenomenon Standard T est Level Notes & Conditions Conducted EN55032 Class B Radiated EN55032 Class B Harmonic Current EN61000-3-2 Class A Less than 80% load
EMC: Immunity Phenomenon Standard T est Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 3 A Contact ±6kV / Air ±8kV Radiated Immunity EN61000-4-3 3 A 10V/m EFT EN61000-4-4 4 A ±4kV Surge EN61000-4-5 Installation class 4 A Line to line ±2kV , line to ground ±4kV Conducted EN61000-4-6 3 A 10Vrms Dips EN61000-4-11 Dip. 100% (0VAC), 10ms B Dip. 100% (0VAC), 20ms B Dip. 60% (88VAC), 200ms A Dip. 30% (154VAC), 500ms A Dip. 20% (176VAC), 5000ms A Interruptions Int. 100% (0VAC), 5000ms B Safety Approvals Certification Standard Notes & Conditions UL UL62368-1 Information T echnology EN EN62368-1, EN60335, EN61558 Information T echnology and Household CE Meets all applicable directives UKCA Meets all applicable legislation AC-DC POWER SUPPLIESLCS150 Series
-30 -10 10 20 30 40 45 500 Ambient temperature (°C) 100 Output power (%) 60 70-20 (15V, 24V, 36V, 48V) (12V) T emperature Derating AC-DC POWER SUPPLIES LCS150 Series
V Out Adj. Power ‘ON’ LED 3x M3x0.5 Thread Max. Penetration = 5mm 2x M3x0.5 Thread Max. Penetration = 3mm Typ. Pitch (Typ.) < Pin 1 < Pin 7 6.000 (152.4) 5.906 (150.0) 0.138 (3.5) 0.866 (22.0) 2x 4.606 (117.0) 3.071 (78.0) 0.945 (24.0) 6.260 (159.0) 3.819 (97.0) 0.236 (6.0) 0.571 (14.5) 0.945 (24.0) 1.024 (26.0) 1.181 (30.0) 0.138 (3.5) 0.374 (9.5) 0.323 (8.2) 1. All dimensions are in inches (mm). 2. Tightening torque: M3, 0.4Nm fixings. 3. General tolerances: ±0.039 (±1.00). 4. Chassis must be connected to protective earth. Notes:
12 Aug 2021
1 AC(L)
2 AC(N)
3 GND
Connector torque: M4, 0.9Nm