PROCESS CONTROL PROTECTION LCP Load Cell Protector The Novaris LCP provides protection for both 4-wire and 6-wire loadcells as well as the measuring instrument. The LCP is contained within an IP65 enclosure, or alternatively as a PCB only. Installation of the LCP is certified and does not affect weighbridge calibration. LCP-18 LCP-36 LCP-18-PCB LCP-36-PCB Electrical Specifications Connection type Series Modes of protection Transverse and common mode Maximum continuous voltage (DC) Uc 18V 36V 18V 36V Maximum discharge current (8/20µs) Imax 250A Protection stages SAD and GDT Voltage protection level @ 0.25kA (8/20µs) UP <40 <70 <40 <70 Impulse durabiltiy C1 8/20µs, 0.25kA, 300 times Over stressed fault mode Mode 2 Maximum load current IL 6.5A 5A Lines protected 4 or 6 Mechanical Specifications Operating temperature / humidity -40 to +85ºC / 5 to 95% non-condensing Terminal capacity 2.5mm Terminal screw torque 0.5Nm Ground connection M5 s/s stud 100mm lead Environmental IP 65 IP 00 Mounting Panel mount Enclosure / colour Aluminium / black PCB only Weight 600g 80g Dimensions Width 116mm 76mm Height 65mm 63mm Depth 56mm 20mm Standards Compliance IEC61643-21 ITU-T K.44 AS/NZS 1768 IEEE C62.41 UL497B NSC No: S366 LCP - 36 - [*] Product Series Option U c IECEx ia and ATEX models available with the Novaris Hazardous Area range Refer to page 58 for signalling protocol compatibility