  • 3 Year Warranty The LCL series is a low cost chassis mount product that is popular in industrial applications. The AC/DC supplies are enclosed in a metal case with terminal block input and output connectors. Three series offer 150, 300 and 500 Watts. Each power range includ es six single output models from 12 to 48 VDC. The user adjustable outputs cover all nominal voltage ranges. The LCL150 is convect ion cooled while the 300 and 500 Watt have internal fans. All LCL models are approved to ITE (60950-1) safety standards and meet EN55022 Level B conducted emissions. Operating temperature range is from -10 °C to +70 °C with derating above +50 °C. Standard features include overvoltage, overload, short circuit, and over temperature protection. Remote sense is included on the LCL500 with Remote On/Off available with the LCL300 a nd LCL500.

xppower.com Input Characteristics Input Derating Curve Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 264 VAC Derate output power < 90 VAC. See fig. 1. Input Frequency 47 63 Hz Power Factor >0.9 EN61000-3-2 class A compliant LCL150: EN61000-3-2 class C for loads ≥40% LCL300 & LCL500: EN61000-3-2 class C for loads ≥40% Input Current - Full Load 2.1 A LCL150 at 90 VAC

4.5 LCL300 at 90 VAC

6.6 LCL500 at 90 VAC

Inrush Current 50 A LCL150, 230 VAC, cold start 25 ˚C

60 LCL300 & LCL500, 230 VAC, cold start 25 ˚C

Earth Leakage Current <2 mA 264 VAC/60 Hz Input Protection T3.15 A/250 V internal in-line fuse LCL150 T6.3 A/250 V internal in-line fuse LCL300 T10 A/250 V internal in-line fuse LCL500 Models and Ratings 85 90 Output Power (%) 100 264 Input Voltage (VAC) Output Power Output Voltage Trim Range Output Current Ripple & Noise(1) Model Number 150 W 12.0 V 11.0-13.0 V 12.5 A 100 mV pk-pk LCL150PS12 13.5 V 12.5-14.5 V 11.1 A 100 mV pk-pk LCL150PS13 15.0 V 14.0-16.0 V 10.0 A 100 mV pk-pk LCL150PS15 24.0 V 23.0-25.0 V 6.3 A 150 mV pk-pk LCL150PS24 27 .0 V 26.0-28.0 V 5.6 A 150 mV pk-pk LCL150PS27 48.0 V 47 .0-49.0 V 3.1 A 250 mV pk-pk LCL150PS48 300 W 12.0 V 11.0-13.0 V 25.0 A 150 mV pk-pk LCL300PS12 13.5 V 12.5-14.5 V 22.0 A 150 mV pk-pk LCL300PS13 15.0 V 14.0-16.0 V 20.0 A 150 mV pk-pk LCL300PS15 310 W 24.0 V 23.0-25.0 V 13.0 A 150 mV pk-pk LCL300PS24 315 W 27 .0 V 26.0-28.0 V 11.7 A 200 mV pk-pk LCL300PS27 320 W 48.0 V 47 .0-49.0 V 6.70 A 240 mV pk-pk LCL300PS48 500 W 12.0 V 11.0-13.0 V 42.0 A 120 mV pk-pk LCL500PS12 13.5 V 12.5-14.5 V 37 .0 A 150 mV pk-pk LCL500PS13 15.0 V 14.0-16.0 V 34.0 A 150 mV pk-pk LCL500PS15 24.0 V 23.0-25.0 V 21.0 A 150 mV pk-pk LCL500PS24 27 .0 V 26.0-28.0 V 18.5 A 150 mV pk-pk LCL500PS27 48.0 V 47 .0-49.0 V 10.5 A 240 mV pk-pk LCL500PS48 1. Measured with 20 MHz bandwidth. Notes:

xppower.com Output Overload Characteristics Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table Initial Set Accuracy ±100 mV 50% load Output Voltage Adjustment ±1 V See Models and Ratings table Minimum Load 0 A Start Up Delay 2 s Start Up Rise Time ms LCL150

80 LCL300

35 LCL500

Hold Up Time 10 ms 115 VAC full load Line Regulation ±0.5 LCL150 ±0.3 LCL300 & LCL500 Load Regulation ±1 % T ransient Response 4 % Recovery within 1% in less than 500 μs for a 50% load change Ripple & Noise See Models and Ratings table Overvoltage Protection 110 140 % Recycle input to reset Overload Protection 110 150 % Rated output power, delayed by 1 s minimum to allow peak loads. See fig 2, 3 & 4 Short Circuit Protection Auto recovery, hiccup mode Overtemperature Protection Output turns off when OTP triggered, measured internally (Q1 temperature), auto recover when internal temperature was reduced. 11.96 11.98 12.02 12.04 12.06 12.5 12.75 13 13.25 Unit enters hiccup mode 13.5 13.75 14 14.25 Current (A) 100% 102% 104% 106% 108% 110% 112% 114% Percent Overload 90Vac 115Vac 230Vac 264Vac Output Voltage (V) Figure 2 - LCL150PS12

xppower.com General Specifications Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 85 88 % 230 VAC full load, See fig 5, 6 & 7 Isolation: Input to Output Input to Ground Output to Ground 3000 VAC1500 500 Switching Frequency 45 190 kHz PFC Converter LCL15090 110 Main Converter 62 65 PFC Converter LCL300 & LCL50080 190 Main converter Power Density 2.7 W/in LCL150

4.4 LCL300

4.9 LCL500

MTBF 200 kHrs MIL-HDBK-217F at 25 ˚C, GB Weight 1.39 (630) lb (g) LCL150 See mechanical details1.94 (880) lb (g) LCL300 3.2 (1.45) lb (kg) LCL500 Output Overload Characteristics 23.6 23.7 23.8 23.9 24.1 Current (A) Output Voltage (V) 100% 102% 104% 106% 108% 110% 112% 114% 116% Percent Overload 90Vac 115Vac 230Vac 264Vac Unit enters hiccup mode Figure 3 - LCL300PS24 47 .5 47 .6 47 .7 47 .8 47 .9 48.1 Current (A) Output Voltage (V) 100% 103% 105% 108% 110% 113% 115% 118% 120% Percent Overload 90Vac 115Vac 230Vac 264Vac Unit enters hiccup mode Figure 4 - LCL500PS48

xppower.com Safety Agency Approvals Safety Agency Safety Standard Category CB Report US/14041/UL IEC 60950-1 (2005) Ed 2 E139109-A27-CB-1 Information T echnology LCL150 US/14236/UL IEC 60950-1 (2005) Ed 2 E139109-A29-CB-1 LCL300 US/14254/UL IEC 60950-1 (2005) Ed 2 E139109-A28-CB-1 LCL500 UL UL File #E139109 UL60950-1(2007) CSA 22.2 No. 60950-1-07 Ed 2 Information T echnology TUV TUV Certificate #B09 07 57396 061 EN60950-1/A11:2009 Information T echnology LCL150 TUV Certificate #B09 07 57396 062 EN60950-1/A11:2009 LCL300 TUV Certificate #B09 07 57396 063 EN60950-1/A11:2009 LCL500 Equipment Protection Class Safety Standard Notes & Conditions Class I IEC 60950-1-2005 Ed 2 See safety agency conditions of acceptability for details Pin Function 1 +Vout 2 +Vout 3 -Vout 4 -Vout

5 Ground

6 AC Neutral

7 AC Live

Notes: Weight: 1.39 lbs (630g) approx. Dimensions shown in inches (mm). T olerance is ±0.05 (±0.2) maximum. Mechanical Details - LCL150 1.02 (26.0) 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 1.97 (50.0) 0.90 (23.0) 0.57 (14.5) 4.64 (118.0) 0.57 (14.5) 0.90 (23.0) 4.64 (118.0) 1.02 (26.0) 7 .55 (192.0) T erminal Block, M4 Screw 7 pins 0.37 (9.5) centre 3.74 (95.0) 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 2 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration

Mechanical Details - LCL300 LCL500 xppower.com Weight: 1.94 lbs (880g) approx. Dimensions shown in inches (mm). T olerance is ±0.05 (±0.2) maximum. Airflow direction is out of the unit at fan. J1 Pin Connections Pin Function 1 +Vout 2 +Vout 3 +Vout 4 -Vout 5 -Vout 6 -Vout

7 Ground

8 AC Neutral

9 AC Live

Weight: 3.2 lbs (1.45 kg) approx. Dimensions shown in inches (mm). T olerance is ±0.05 (±0.2) maximum. Applying >4.5 V to Pin 2 with respect to Pin 1 turns output off. Applying <0.8 V to Pin 2 with respect to Pin 1 or open circuit turns output on. Mating Connectors (J2): WST P4-I25002 housing WST I25002BS contacts J1 Pin Connections Pin Function 1 +Vout 2 +Vout 3 +Vout 4 -Vout 5 -Vout 6 -Vout

1 Remote Control -

2 Remote Control +

3 Sense -

4 Sense +

1.97 (50.0) 0.63 (16.0) 8.07 (205.0) 1.97 (50.0)0.94 (24.0) 0.63 (16.0) 6.81 (173.0) 6.81 (173.0) 1.97 (50.0) 0.98 (25.0) 0.50 (12.5) 4.33 (110.0) 7 .44 (189.0) T erminal Block, M4 Screw 9 pins 0.37 (9.5) centre 3 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 3 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 1.41 (36.0) 2.08 (53.0) 0.60(15.0) 1.00 (25.5) 5.00 (127 .0) 9.21 (234.0) 9.84 (250.0) (15.0) 1.00 (25.5) 1.41 (0.36) (36.0) 3.54 (90.0) T erminal Block, M4 Screw 9 pins 0.37 (9.5) centre AIRFLOW 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration 4 x M4 x 0.7 THD 0.15 (3.8) Max Screw Penetration