LCA120 CLARE | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 6
Technical content
Features
Description
Ordering Information
Switching Characteristics of Normally Open (Form A) Devices /K43/K4F/K4E/K54/K52/K4F/K4C /K4C/K4F/K41/K44 /K31/K30/K6D/K73 /K31/K30/K25 /K31/K30/K25 /K39/K30/K25 /K2B /K54 /K4F/K4E /K54 /K4F/K46/K46 /K2B /K2B
- Telecommunications
- Telecom Switching
- Tip/Ring Circuits
- Modem Switching (Laptop, Notebook, Pocket Size)
- Hookswitch
- Dial Pulsing
- Ground Start
- Ringer Injection
- Instrumentation
- Multiplexers
- Data Acquisition
- Electronic Switching
- I/O Subsystems
- Meters (Watt-Hour, Water, Gas)
- Medical Equipment-Patient/Equipment Isolation
- Security
- Aerospace
- Industrial Controls
- Small 6 Pin DIP Package
- Low Drive Power Requirements (TTL/CMOS Compatible)
- No Moving Parts
- High Reliability
- Arc-Free With No Snubbing Circuits
- 3750VRMS Input/Output Isolation
- FCC Compatible
- VDE Compatible
- No EMI/RFI Generation
- Machine Insertable, Wave Solderable
- Surface Mount and Tape & Reel Versions Available + Control – Control Do Not Use Load Do Not Use Load AC/DC Configuration LCA120 Pinout + Control – Control Do Not Use + Load – Load DC Only Configuration LCA120 Pinout
- UL Recognized: File Number E76270
- CSA Certified: File Number LR 43639-10
- BSI Certified to:
- BS EN 60950:1992 (BS7002:1992) Certificate #: 7344
- BS EN 41003:1993 Certificate #: 7344 LCA120 is a 250V, 170mA, 20Ω 1-Form-A relay. It fea- tures enhanced peak load current capability. Current limiting version is available. (“L” suffix)
Parameter Conditions Symbol Min Typ Max Units Output Characteristics @ 25°C Load Voltage (Peak) - V L - - 250 V Load Current (Continuous) AC/DC Configuration - I L - - 150 mA DC Configuration - I L - - 200 mA Peak Load Current 10ms I LPK --- m A On-Resistance AC/DC Configuration I L=Load Current R ON -1 5 2 0 Ω DC Configuration I L=Load Current - 5 6 Ω Off-State Leakage Current V L=25OV I LEAK -- 1 µ A Switching Speeds Turn-On I F=5mA, VL=10V T ON -- 3 m s Turn-Off I F =5mA, VL=10V T OFF -- 3 m s Output Capacitance 50V; f=1MHz C OUT -5 0- p F Input Characteristics @ 25°C Input Control Current I L=Load Current I F 5- 5 0m A Input Dropout Current - I F 0.4 0.7 - mA Input Voltage Drop I F=5mA V F 0.9 1.2 1.4 V Reverse Input Voltage - V R -- 5 V Reverse Input Current V R=5V I R - - 10 µA Input to Output Capacitance - C I/O -3- p F Input to Output Isolation - V I/O 3750 - - V RMS www.clare.com LCA120 Rev. 8 Absolute Maximum Ratings are stress ratings. Stresses in excess of these ratings can cause permanent damage to the device. Functional operation of the device at these or any other conditions beyond those indicated in the opera- tional sections of this data sheet is not implied. Exposure of the device to the absolute maximum ratings for an extend- ed period may degrade the device and effect its reliability. Absolute Maximum Ratings (@ 25˚ C)
Electrical Characteristics
Parameter Min Typ Max Units Input Power Dissipation - - 150 1 mW Input Control Current - - 50 mA Peak (10ms) - - 1 A Reverse Input Voltage - - 5 V Total Power Dissipation - - 800 2 mW Isolation Voltage Input to Output 3750 - - V RMS Operational Temperature -40 - +85 °C Storage Temperature -40 - +125 °C Soldering Temperature Surface Mount Package - - +220 °C (10 Seconds Max.) 1 Derate Linearly 1.33 mw/˚C 2 Derate Linearly 6.67 mw/˚C
www.clare.comRev. 8 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in t he written specifications, please contact our application department. LCA120 Typical LED Forward Voltage Drop (N=50 Ambient Temperature = 25°C) IF = 5mADC LED Forward Voltage Drop (V) Device Count (N) LCA120 Typical On-Resistance Distribution (N=50 Ambient Temperature = 25°C) (Load Current = 170mADC; IF = 5mADC) On-Resistance (Ω) Device Count (N) LCA120 Typical Blocking Voltage Distribution (N=50 Ambient Temperature = 25°C) 305 325 345 365315 335 355 Blocking Voltage (V) Device Count (N) LCA120 Typical IF for Switch Operation (N=50 Ambient Temperature = 25°C) (Load Current = 170mADC) LED Current (mA) Device Count (N) LCA120 Typical IF for Switch Dropout (N=50 Ambient Temperature = 25°C) (Load Current = 170mADC LED Current (mA) Device Count (N) LCA120 Typical Turn-On Time (N=50 Ambient Temperature = 25°C) (Load Current = 170mADC; IF = 5mADC) Turn-On (ms) Device Count (N) LCA120 Typical Turn-Off Time (N=50 Ambient Temperature = 25°C) (Load Current = 170mADC; IF = 5mADC) Turn-Off (ms) Device Count (N) LCA120 Typical Load Current vs. Temperature Temperature (°C) Load Current (mA) 250 200 150 100 -40 -20 0 20 40 60 80 120 100 20mA 10mA 5mA LCA120 Typical Leakage vs. Temperature (Measured across Pins 4 & 6) Temperature (°C) Leakage (µA) -40 0.0250 0.0200 0.0150 0.0100 0.0050 -20 0 20 40 60 80 100 LCA120 Typical Blocking Voltage vs. Temperature Temperature (°C) Blocking Voltage (VRMS) -40 350 345 340 335 330 325 320 315 -20 0 20 40 60 80 100 LCA120 Typical Turn-On vs. Temperature (Load Current = 170mADC) Temperature (°C) 5mA 10mA 20mA Turn-On (ms) -40 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 -20 0 20 40 60 80 100 LCA120 Typical Turn-Off vs. Temperature (Load Current = 170mADC) Temperature (°C) Turn-Off (ms) -40 0.700 0.600 0.500 0.400 0.300 0.200 0.100 -20 0 20 40 60 80 100 5mA
www.clare.com4 LCA120 Rev. 8 PERFORMANCE DATA* *The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in t he written specifications, please contact our application department. LCA120 Typical LED Forward Voltage Drop vs. Temperature Temperature (°C) LED Forward Voltage Drop (V) 1.8 1.6 1.4 1.2 1.0 0.8 -40 -20 0 20 40 60 80 120 100 50mA 30mA 20mA 10mA 5mA LCA120 Typical Turn-On vs.LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) Turn-On (ms) 0 5 1 01 52 02 53 03 54 04 5 1.4 1.2 1.0 0.8 0.6 0.4 0.2 LCA120 Typical Turn-Off vs.LED Forward Current (Load Current = 170mADC) LED Forward Current (mA) Turn-Off (ms) 0 5 1 01 52 02 53 03 54 04 5 0.410 0.400 0.390 0.380 0.370 0.360 0.350 0.340 LCA120 Typical On-Resistance vs. Temperature (Load Current = 170mADC; IF = 5mADC) Temperature (°C) On-Resistance (Ω) -40 60.000 50.000 40.000 30.000 20.000 10.000 -20 0 20 40 60 80 100 LCA120 Typical Load Current vs. Load Voltage (Ambient Temperature = 25°C) IF = 5mADC Load Voltage (V) Load Current (mA) 200 150 100 -50 -100 -150 -200 LCA120 Energy Rating Curve Time Load Current (A) 10µs 1.2 1.0 0.8 0.6 0.4 0.2 1ms 100ms 10s100µs 10ms 1s 100s LCA120 Typical IF for Switch Operation vs. Temperature (Load Current = 170mADC) Temperature (°C) LED Current (mA) -40 2.500 2.000 1.500 1.000 0.500 -20 0 20 40 60 80 100 LCA120 Typical IF for Switch Dropout vs. Temperature (Load Current = 170mADC) Temperature (°C) LED Current (mA) -40 2.500 2.000 1.500 1.000 0.500 -20 0 20 40 60 80 100
www.clare.com 5Rev. 8 Dimensions mm (inches) MECHANICAL DIMENSIONS PC Board Pattern (Top View) 6.350 ± .127 (.250 ± .005) 2.540 ± .127 (.100 ± .005) 7.620 ± .127 (.300 ± .005) 5.080 ± .127 (.200 ± .005) 6-.800 DIA. (6-.031 DIA.) PC Board Pattern (Top View) 2.540 ± .127 (.100 ± .005) 8.305 ± .127 (.327 ± .005) 1.905 ± .127 (.075 ± .005) 1.499 ± .127 (.059 ± .005) Tape and Reel Packaging for 6 Pin Power DIP Surface Mount Package 7.493 – .102 (.295 – .004) 12.090 (.476) 1.753 – .102 (.069 – .004) 3.987 – .102 (.157 – .004) 1.498 – .102 (.265) .406 MAX. (.016) 4.877 (.192) Top Cover Tape 2.007 – .102 (.079 – .004) 11.989 – .102 (.472 – .004) User Direction of Feed .050R TYP. 16.002 – .305 (.630 – .012) 10.300 (.405) Embossment Embossed Carrier Top Cover Tape Thickness .102 MAX. (.004) 10.300 – .102 (.405 – .004) 1.549 – .102 (.061 – .004) 330.2 DIA. (13.00) 1 6
6 Pin Power DIP Through Hole (Standard)
6 Pin Power DIP Surface Mount ( “S” Suffix)
78 Cherry Hill Drive
Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Clare Switch Division 4315 N. Earth City Expressway Earth City, MO 63045 Tel: 1-314-770-1832 Fax: 1-314-770-1812 Clare Micronix Division
145 Columbia
Aliso Viejo, CA 92656-1490 Tel: 1-949-831-4622 Fax: 1-949-831-4628 SALES OFFICES AMERICAS Americas Headquarters Clare Beverly, MA 01915 Tel: 1-978-524-6700 Fax: 1-978-524-4900 Toll Free: 1-800-27-CLARE Eastern Region Clare
603 Apache Court
Mahwah, NJ 07430 Tel: 1-201-236-0101 Fax: 1-201-236-8685 Toll Free: 1-800-27-CLARE Central Region Clare Canada Ltd.
3425 Harvester Road, Suite 202
Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 Western Region Clare
1852 West 11th Street, #348
Tracy, CA 95376 Tel: 1-209-832-4367 Fax: 1-209-832-4732 Toll Free: 1-800-27-CLARE Canada Clare Canada Ltd. Burlington, Ontario L7N 3N1 Tel: 1-905-333-9066 Fax: 1-905-333-1824 EUROPE European Headquarters CP Clare nv Bampslaan 17 B-3500 Hasselt (Belgium) Tel: 32-11-300868 Fax: 32-11-300890 France Clare France Sales Lead Rep 99 route de Versailles
91160 Champlan
Tel: 33 1 69 79 93 50 Fax: 33 1 69 79 93 59 Germany Clare Germany Sales ActiveComp Electronic GmbH Mitterstrasse 12
85077 Manching
Tel: 49 8459 3214 10 Fax: 49 8459 3214 29 Italy Via C. Colombo 10/A I-20066 Melzo (Milano) Tel: 39-02-95737160 Fax: 39-02-95738829 Sweden Clare Sales Comptronic AB Box 167 S-16329 Spå nga Tel: 46-862-10370 Fax: 46-862-10371 United Kingdom Clare UK Sales Marco Polo House Cook Way Bindon Road Taunton UK-Somerset TA2 6BG Tel: 44-1-823 352541 Fax: 44-1-823 352797 ASIA/PACIFIC Asian Headquarters Clare Room N1016, Chia-Hsin, Bldg II, 10F, No. 96, Sec. 2 Chung Shan North Road Taipei, Taiwan R.O.C. Tel: 886-2-2523-6368 Fax: 886-2-2523-6369 http://www.clare.com Clare, Inc. makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice. Neither circuit patent licenses nor indemnity are expressed or implied. Except as set forth in Clare’s Standard Terms and Conditions of Sale, Clare, Inc. assumes no liability whatsoever, and disclaims any express or implied warranty, relating to its products including, but not limit- ed to, the implied warranty of merchantability, fitness for a partic- ular purpose, or infringement of any intellectual property right. The products described in this document are not designed, intended, authorized or warranted for use as components in sys- tems intended for surgical implant into the body, or in other appli- cations intended to support or sustain life, or where malfunction of Clare’s product may result in direct physical harm, injury, or death to a person or severe property or environmental damage. Clare, Inc. reserves the right to discontinue or make changes to its products at any time without notice. Specification: DS-LCA120-R8 ©Copyright 2001, Clare, Inc. OptoMOS ® is a registered trademark of Clare, Inc. All rights reserved. Printed in USA. 7/17/01