Features
- Error correction capability improved by soft-decision error correction
- The load on the control microprocessor can be reduced by storing decoded data in the on-chip data buffer RAM.
- Two synchronization detection circuits provide continuous and stable detection of the synchronization timing.
- Data can be read out starting with the backward- protection block data after a synchronization reset.
- Bit slip detection and correction
- Low spurious radiation
- Fully adjustment free
- Operating power-supply voltage: 4.5 to 5.5 V
- Operating temperature: –40 to +85°C
- Package: LC72722 : DIP24S LC72722M : MFP24S LC72722PM : MFP24 Package Dimensions unit: mm 3067A-DIP24S LC72722, 72722M, 72722PM SANYO Electric Co.,Ltd. Semiconductor Company TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN Single-Chip RDS Signal-Processing System LSI CMOS IC Any and all SANYO products described or contained herein do not have specifications that can handle applications that require extremely high levels of reliability, such as life-support systems, aircraft’s control systems, or other applications whose failure can be reasonably expected to result in serious physical and/or material damage. Consult with your SANYO representative nearest you before using any SANYO products described or contained herein in such applications. SANYO assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all SANYO products described or contained herein.
- CCB is a trademark of SANYO ELECTRIC CO., LTD.
- CCB is SANYO’s original bus format and all the bus addresses are controlled by SANYO. 0.48 (3.25) 3.3 3.9max 0.51min 21.0 (0.71) 1.78 0.25 7.62 6.4 1 12 24 13 0.95 0.9 SANYO: DIP24S [LC72722]
unit: mm 3112A-MFP24S unit: mm 3045C-MFP24 No. 5602-2/15 LC72722, 72722M, 72722PM 1 12 24 13 1.27 15.2 0.35 10.5 7.9 (0.62) 2.35max 0.1 (2.15) 0.65 0.15 SANYO: MFP24 [LC72722PM] 1 12 24 13 12.5 (0.75)1.0 0.15 0.35 5.4 7.6 0.63 1.7max 1.50.1 SANYO: MFP24S [LC72722M] Pin Assignment Block Diagram A12363 1 24VREF SYR 2 23MPXIN CE 3 22Vdda DI 4 21Vssa CL 5 20FLOUT DO 6 19CIN LC72722 LC72722M LC72722PM Top view RDS-ID 7 18T1 SYNC 8 17T2 T7(CORREC/ARI-ID/TA/BEO) 9 16T3(RDCL) T6(ERROR/57K/TP/BE1) 10 15T4(RDDA) Vssd 11 14T5(RSFT) Vddd 12 13XOUT XIN REFERENCE VOLTAGE ANTIALIASING FILTER SMOOTHING FILTER 57 kHz BPF (SCF) TEST PLL (57 kHz) VREF CLOCK RECOVERY (1187.5 Hz) DATA DECODER SYNC DETECT-2 SYNC DETECT-1 OSC/DIVIDER MEMORY CONTROL CLK(4.332 MHz) +5V +5V Vdda Vssa MPXIN T3 to T7 CCBDI CE CL RAM (24 BLOCK DATA) ERROR CORRECTION (SOFT DECISION) SYNC/EC CONTROLLER DO XIN XOUT SYR SYNC RDS-ID Vssd Vddd CINFLOUTVREF A12364
No. 5602-3/15 LC72722, 72722M, 72722PM Pin Functions Pin N o. Pin name Function I/O Pin circuit
1 VREF Reference voltage output (Vdda/2) Output
2 MPXIN Baseband (multiplexed) signal input Input
5 FLOUT Subcarrier output (filter output) Output
6 CIN Subcarrier input (comparator input) Input
3 Vdda Analog system power supply (+5 V) — —
4 Vssa Analog system ground — —
12 XOUT Crystal oscillator output (4.332/8.664 MHz) Output
13 XIN Crystal oscillator input (external reference signal input)
7 T1 Test input (This pin must always be connected to ground.) Input
8 T2 Test input (standby control)
0: Normal operation, 1: Standby state (crystal oscillator stopped)
9 T3 (RDCL) Test I/O (RDS clock output)
10 T4 (RDDA) Test I/O (RDS data output)
11 T5 (RSFT) Test I/O (soft-decision control data output)
16 T6 (ERROR/57K/TP/BE1) Test I/O (error status output, regenerated carrier output,I/O*TP output, error block count output)
17 T7 (CORREC/ARI-ID/TA/BE0) Test I/O (Error correction status output, SK detection output,
TA output, error block count output)
18 SYNC Block synchronization detection output
19 RDS-ID RDS detection output
20 DO Data output
21 CL Clock input
22 DI Data input
24 SYR Synchronization and RAM address reset (active high)
14 Vddd Digital system power supply (+5 V) — —
15 Vssd Digital system ground — —
Note: * Normally function as an output pin. Used as an I/O pin in test mode, which is not available to user applications. Serial data interface (CCB) Vdda Vssa A12365 Vdda Vssa A12366 A12367 Vdda VREF Vssa A12368 Vddd Vssd A12369 XOUT XIN A12370Vssd S A12371 Vssd A12372 Vssd A12373Vssd S
No. 5602-4/15 LC72722, 72722M, 72722PM Parameter Symbol Conditions Ratings Unit Maximum supply voltage VDD max Vddd, Vdda: Vdda ≤ Vddd +0.3 V –0.3 to +7.0 V VIN1 max CL, DI, CE, SYR, T1, T2, T3, T4, T5, T6, T7, SYNC –0.3 to +7.0 V Maximum input voltage VIN2 max XIN –0.3 to Vddd +0.3 V VIN3 max MPXIN, CIN –0.3 to Vdda +0.3 V VO 1 max DO, SYNC, RDS-ID, T3, T4, T5, T6, T7 –0.3 to +7.0 V Maximum output voltage VO 2 max XOUT –0.3 to Vddd +0.3 V VO 3 max FLOUT –0.3 to Vdda +0.3 V IO 1 max DO, T3, T4, T5, T6, T7 6.0 mA Maximum output current IO 2 max XOUT, FLOU T 3.0 mA IO 3 max SYNC, RDS-ID 20.0 mA LC72722:DIP24S: 350 mW Allowable power dissipation Pd max Ta ≤ 85°C LC72722M:MFP24S: 150 mW LC72722PM:MFP24: 175 mW Operating temperature Topr –40 to +85 °C Storage temperature Tstg –55 to +125 °C Specifications Absolute Maximum Ratings at Ta = 25°C, Vssd = Vssa = 0 V Parameter Symbol Conditions Ratings Unit min typ max Supply voltage VDD 1 Vddd, Vdda: Vddd = Vdda 4.5 5.0 5.5 V VDD 2 Vddd: Serial data hold voltage 2.0 V Input high-level voltage VIH CL, DI, CE, SYR, T1, T2 0.7 Vddd 6.5 V Input low-level voltage VIL CL, DI, CE, SYR, T1, T2 0 0.3 Vddd V Output voltage VO DO, SYNC, RDS-ID, T3, T4, T5, T6, T7 6.5 V VIN1 MPXIN : f = 57 ±2 kHz 50 mVrms Input amplitude VIN2 MPXIN : 100% modulation composite 100 mVrms VXIN XIN 400 1500 mVrms Guaranteed crystal oscillator frequencies Xtal XIN, XOUT : CI ≤ 120 Ω (XS = 0) 4.332 MHz XIN, XOUT : CI ≤ 70 Ω (XS = 1) 8.664 MHz Crystal oscillator frequency deviation TXtal XIN, XOUT : fO = 4.322 MHz, 8.664 MHz ±100 ppm Data setup time tSU DI, CL 0.75 µs Data hold time tHD DI, CL 0.75 µs Clock low-level time tCL CL 0.75 µs Clock high-level time tCH CL 0.75 µs CE wait time tEL CE, CL 0.75 µs CE setup time tES CE, CL 0.75 µs CE hold time tEH CE, CL 0.75 µs CE high-level time tCE CE 20 ms Data latch change time tLC 1.15 µs tDC DO, CL: Differs depending on the value of the 0.46 µs Data output time pull-up resistor used. tDH DO, CE: Differs depending on the value of the 0.46 µs Allowable Operating Ranges at Ta = –40 to +85°C, Vssd = Vssa = 0 V Parameter Symbol Conditions Ratings Unit min typ max Input resistance Rmpxin MPXIN–Vssa : f = 57 kHz 43 kΩ Rcin CIN–Vssa : f = 57 kHz 100 kΩ Internal feedback resistance Rf XIN 1.0 M Ω Center frequency fc FLOUT 56.5 57.0 57.5 kHz –3 dB bandwidth BW – 3 dB FLOUT 2.5 3.0 3.5 kHz Gain Gain MPXIN–FLOOUT : f = 57 kHz 28 31 34 dB Electrical Characteristics at Ta = –40 to +85°C, Vssd = Vssa = 0 V Continued on next page.
No. 5602-5/15 LC72722, 72722M, 72722PM Parameter Symbol Conditions Ratings Unit min typ max Att1 FLOUT : ∆f = ±7 kHz 30 dB Stop band attenuation Att2 FLOUT : f < 45 kHz, f > 70 kHz 40 dB Att3 FLOUT : f < 20 kHz 50 dB pull-up resistor used.Reference voltage outputVref VREF : Vdda = 5 V 2.5 V Hysteresis VHIS CL, DI, CE, SYR, T1, T2 0.1 Vddd V Output low-level voltage VOL 1 DO, T3, T4, T5, T6, T7 : I = 2 mA 0.4 V VOL 2 SYNC, RDS-ID : I = 8 mA 0.4 V Input high-level current IIH1 CL, DI, CE, SYR, T1, T2 : VI= 6.5 V 5.0 µA IIH2 XIN : VI= Vddd 2.0 11 µA Input low-level current IIL1 CL, DI, CE, SYR, T1, T2 : VI= 0 V 5.0 µA IIL2 XIN : VI= 0 V 2.0 11 µA Output off leakage current IOFF DO, SYNC, RDS-ID, T3, T4, T5, T6, T7 : 5.0 µAVO = 6.5 V Current drain Idd Vddd + Vdda 9 mA Continued from preceding page. CCB Output Data Format
- Each block of output data consists of 32 bits (4 bytes), of which 2 bytes are RDS data and 2 bytes are flag data.
- Any number of 32-bit output data blocks can be output consecutively.
- When there is no data that can be read out in the internal memory, the system outputs blocks of all-zero data consecutively.
- If data readout is interrupted, the next read operation starts with the 32-bit data block whose readout was interrupted. However, if only the last bit remains to be read, it will not be possible to reread that whole block.
- The check bits (10 bits) are not output.
- The data valid/invalid decision is made by referencing the error information flags (E0 to E2) must not be referred to.
- When the first leading bits are not "1010", the read in data is invalid, and the read operation is cancelled. 1. Offset word detection flag (1 bit): OWD OWD Offset word detection
1 Detected
0 Not detected (protection function operating)
B 1 0 1 0 O W D R F R F A R I S Y C D D D D D D B E E E D D D D D D D D D D B B R E 0 1 1 0 1 1 0 B B B A A A A CCB address 6C Output data/first bit Last bit (8) RDS data (7) Error information flags (6) Synchronization established flag (5) ARI (SK) detection flag (4) RAM data remaining flag (3) Consecutive RAM read out possible flag (2) Offset word information flag (1) Offset word detection flag Fixed pattern (1010)
No. 5602-6/15 LC72722, 72722M, 72722PM 2. Offset word information flag (3 bits): B0 to B2 B B B Offset word2 1 0 0 0 0 A 0 0 1 B 0 1 0 C 0 1 1 C’ 1 0 0 D 1 0 1 E 1 1 0 Unused 1 1 1 Unused 3. Consecutive RAM readout possible flag (1 bit): RE RE RAM data information 1 The next data to be read out is in RAM. 0 This data item is the last item in RAM, and the next data is not present. ARI SK signal
0 Not detected
- RAM data remaining flag (2 bits): RF0, RF1 Caution:This value is only meaningful when RE is 1. When RE is 0, there is no data in RAM, even if RF is 00. If a synchronization reset was applied using SYR, then the backward protection block data that was written to memory is also counted in this value. Caution:This flag indicates the synchronization state of the circuit at the point where the data block being output was received. On the other hand, the SYNC pin (pin 18) output indicates the current synchronization state of the circuit. Caution:If the number of errors exceeds the value of the EC0 to EC2 setting (see the section on the CCB input format), the error information flags will be set to the “Correction not possible” value. When the error flags E0 to E2 are 011 (indicating that correction is not possible) the data must be handled as invalid data. RF1 RF0 Remaining data in RAM (number of blocks) 0 0 1 to 7 0 1 8 to 15 1 0 16 to 23 1 1 24 5. ARI (SK) detection flag (1 bit): ARI SYC Synchronization detection
1 Synchronized
0 Not synchronized
- Synchronization established flag (1 bit): SYC 7. Error information flags (3 bits): E0 to E2 8. RDS data (16 bits): D0 to D15 This data is output with the MSB first and the LSB last. Caution: When error correction was not possible, the input data is output without change. E E E Number of 2 1 0 bits corrected 0 0 0 0 (no errors) 0 0 1 1 0 1 0 2 0 1 1 3 1 0 0 4 1 0 1 5 1 1 0 Correction not possible 1 1 1 Unused
No. 5602-7/15 LC72722, 72722M, 72722PM CCB Input Data Format Caution: The bits labeled with an asterisk must be set to 0. 1. Synchronization protection (forward protection) method setting (4 bits): FS0 to FS3 FS3 = 0: If offset words in the correct order could not be detected continuously during the number of blocks specified by FS0 to FS2, take that to be a lost synchronization state. FS3 = 1: If blocks with uncorrectable errors were received consecutively during the number of blocks specified by FS0 to FS2, take that to be a lost synchronization state. Initial value: FS0 = 0, FS1 = 1, FS2 = 0, FS3 = 0 Initial value: BS = 0 F F F S S S Condition for detecting lost synchronization 0 1 2 0 0 0 If 3 consecutive blocks matching the FS3 condition are received. 1 0 0 If 4 consecutive blocks matching the FS3 condition are received. 0 1 0 If 5 consecutive blocks matching the FS3 condition are received. 1 1 0 If 6 consecutive blocks matching the FS3 condition are received. 0 0 1 If 8 consecutive blocks matching the FS3 condition are received. 1 0 1 If 10 consecutive blocks matching the FS3 condition are received. 0 1 1 If 12 consecutive blocks matching the FS3 condition are received. 1 1 1 If 16 consecutive blocks matching the FS3 condition are received. 2. Synchronization detection method setting (1 bit): BS BS Synchronization detection conditions 0 If, during 3 blocks, 2 blocks of offset words were detected in the correct order. 1 If the offset words were detected in the correct order in 2 consecutive blocks. DI B 0 1 0 1 0 1 1 0 B B B A A A A F S F S F S F S E C E C E C C T E C E C B S S Y R * * * O W E [1] CCB address 6A [2] CCB address 6B IN1 data, first bit IN2 data, first bit (12) Circuit control (5) Error correction method setting (4) RAM write control (3) Synchronization and RAM address reset (2) Synchronization detection method setting (1) Synchronization protection method setting (11) Test mode settings (10) Output pin settings (9) RDS/RBDS selection (8) Demodulation circuit phase control (7) Crystal oscillator frequency selection (6) Intermittent DO output setting (12) Circuit control DI B 1 1 0 1 0 1 1 0 B B B A A A A C T S P S P P T T S T S T S T S P T P T X S P L P L * *R M
No. 5602-8/15 LC72722, 72722M, 72722PM 3. Synchronization and RAM address reset (1 bit): SYR Initial value: SYR =0 Caution:1.To apply a synchronization reset, set SYR to 1 temporarily using the CCB, and then set it back to 0 again using the CCB. The circuit will start synchronization capture operation at the point SYR is set to 0. 2.The SYR pin (pin 24) also provides an identical reset control operation. Applications can use either method. However, the control method that is not used must be set to 0 at all times. Any pulse with a width of over 250 ns will suffice. 3.A reset must be applied immediately after the reception channel is changed. If a reset is not applied, reception data from the previous channel may remain in memory. 4.Data read out after a synchronization reset is read out starting with the backward protection block data preceding the establishment of synchronization. SYR Synchronization detection circuit RAM 0 Normal operation (reset cleared) Normal write (See the description of the OWE bit.) 1 Forced to the unsynchronized state (synchronization reset)After the reset is cleared, start writing from the data prior to the establishment of synchronization, i.e. the data in backward protection. Initial value: OWE = 0 Initial values: EC0 = 0, EC1 = 1, EC2 = 0, EC3 = 0, EC4 = 1 Caution:1.If soft-decision A or soft-decision B is specified, soft-decision control will be performed even if the number of bits corrected is set to 0 (error detection only). With these settings, data will be output for blocks with no errors. 2.As opposed to soft-decision B, the soft-decision A setting suppresses soft decision error correction. 4. RAM write control (1 bit): OWE 5. Error correction method setting (5 bits): EC0 to EC4 OWE RAM write conditions 0 Only data for which synchronization had been established is written. 1 Data for which synchronization not has been established (unsynchronized data) is also written. (However, this applies when SYR = 0.) E E E Number of C C C bits corrected0 1 2 0 0 0 0 (error detection only) 1 0 0 1 or fewer bits 0 1 0 2 or fewer bits 1 1 0 3 or fewer bits 0 0 1 4 or fewer bits 1 0 1 5 or fewer bits 0 1 1 Illegal value 1 1 1 Illegal value E E C C Soft-decision setting 3 4 0 0 Mode 0: Hard decision 1 0 Mode 1: Soft decision A 0 1 Mode 2: Soft decision B 1 1 Illegal value 6. Intermittent DO output setting SP0 SP1 DO output state 0 0 DO goes low when one or more blocks of data are written to memory. 1 0 DO goes low when 4 or more blocks of data are written to memory. 0 1 DO goes low when 8 or more blocks of data are written to memory. 1 1 DO goes low when 12 or more blocks of data are written to memory. 7. Crystal oscillator frequency selection (1 bit): XS XS = 0: 4.332 MHz XS = 1: 8.664 MHz Initial value: XS = 0 Initial values: SP0 = 0, SP1 = 0
No. 5602-9/15 LC72722, 72722M, 72722PM 8. Demodulation circuit phase control (2 bits): PL0, PL1 Initial values: PL0 = 0, PL1 = 1 Caution:1.When PL0 is 0 (normal operation), the IC detects the presence or absence of the ARI signal and reproduces the RDS data by automatically controlling the demodulation phase with respect to the reproduced carrier. However, the initial phase following a synchronization reset is set by PL1. 2.If PL0 is set to 1, the demodulation circuit phase is locked according to the PL1 setting at either 90° (PL1 = 0) or 0° (PL1 = 1), allowing RDS data to be reproduced. When ARI is not present, PL1 should be set to 0, since the RDS data is reproduced by detecting at a phase of 90° with respect to the reproduced carrier. When ARI is present, PL1 should be set to 1, since detection is at 0°. In cases where the ARI presence is known in advance, more stable reproduction can be achieved by fixing the demodulation phase in this manner. PL0 PL1 Demodulation circuit phase control 0 0/1 <Normal operation> when ARI presence or absence is unclear.
0 If the circuit determines that the ARI signal is absent: 90°phase
1 If the circuit determines that the ARI signal is present: 0°phase
- RDS/RBDS (MMBS) selection (1 bit): RM Initial value: RM = 0 —: Open, ll , l : Output enabled (l = reverse polarity) Initial values: PT0 = 1, PT1 = 1, PT2 = 0 (mode 3) Caution:1.When PT2 is set to 1, T6 (ERROR/57K/TP), T7 (CORREC/ARI-ID/TA) SYNC, and RDS-ID pins change to active high. 2.The output pins (T3 to T7, SYNC, and RDS-ID) are all open-drain pins, and require external pull-up resistors to output data. TP = Traffic program code RM RBDS support Decoding method 0 None Only RDS data is decoded correctly (Offset word E is not detected.) 1 Provided RDS and MMBS data is decoded correctly (Offset word E is also detected.) 10.Output pin settings (3 bits): PT0 to PT2 These bits control the T3, T4, T5, T6, T7, SYNC, and RDS-ID pins. P P P T3 T4 T5 T6 T7Mode T T T 0 1 2 RDCL RDDA RSFT ERROR 57K TP BE1 CORREC ARI-ID TA BE0 2 0 1 0 ll ll ll — ll — — — ll — — 3 1 1 0 ll ll ll ll — — — ll — — — 6 0 1 1 ll ll ll — l — — — l — — 7 1 1 1 ll ll ll l — — — l — — — Mode 1 (PT2 = 0) Pin T6 (TP) TP = 0 detected High (1) TP = 1 detected Low (0) TA = Traffic announcement code Mode 1 (PT2 = 0) Pin T7 (TA) TA = 0 detected High (1) TA = 1 detected Low (0) Mode 2 (PT2 = 0) Pin T7 (ARI-ID) No SK High (1) SK present Low (0) Mode 3 (PT2 = 0) Pin T6 (ERROR) Pin T7 (CORREC) Correction not possible Low (0) Low (0) Errors corrected High (1) Low (0) No errors High (1) High (1)
No. 5602-10/15 LC72722, 72722M, 72722PM These pins indicate the number of blocks in a set of 48 blocks that had errors before correction. The output polarity of these pins is fixed at the values listed in the table. Mode 4 Pin T6 (BE1) Pin T7 (BE0)Number of error blocks (B) B = 0 Low (0) Low (0) 1 ≤ B ≤ 20 Low (0) High (1) 20 < B ≤ 40 High (1) Low (0) 40 < B ≤ 48 High (1) High (1) Caution: The output indicates the synchronization state for the previous block. Mode (PT2 = 0) The SYNC pin 0 to 2 When synchronized: Low (0). When unsynchronized: High (1) When synchronized: Goes high for a fixed period (421 µs) at 3 the start of a block and then goes low. When unsynchronized: High (1) When PT2 = 0 The RDS-ID pin No RDS High (1) RDS present Low (0) 11. Test mode settings (4 bits): TS0 to TS3 Initial values: TS0 = 0, TS1 = 0, TS2 = 0, TS3 = 0 (Applications must set these bits to the above values.) Notes: The T1 and T2 pins (pins 7 and 8) are related to test mode as follows: The T1 pin must be tied to VSS (0 V). Initial values: CT0 = 0, CT1 = 0 Pin T1 Pin T2 LSI operation Notes 0 0 Normal operating mode These states are user settable0 1 Standby mode (crystal oscillator stopped) 1 0/1 LSI test mode Users cannot use this state 12. Circuit control (2 bits): CT0 and CT1 Item Control CT0 RSFT control When set to 1, soft-decision control data (RSFT) is more difficult to generate. CT1 RDS-ID detection conditionWhen set to 1, the RDS-ID detection conditions are made more restrictive. RDCL/RDDA/RSFT and ERROR/CORREC/SYNC Output Timing Timing 1 17 µs 421 µs 421 µs Tp2 Tp1 17 µs RDCL output RSFT output RDDA output A12377
No. 5602-11/15 LC72722, 72722M, 72722PM Timing 2 (mode 3, PT2 = 0) A12378 Input data Error correction SYNC output ERROR output CORREC output Sync NG Sync OK Sync OK Sync OK Sync OK Sync OK Sync NG Sync NG Data corrected No errors No errors Data corrected UncorrectableUncorrectable Tp1 Tp1 Serial Data Input and Output Methods Data is input and output using the CCB (computer control bus), which is the Sanyo audio IC serial bus format. This IC adopts an 8-bit address CCB format. I/O mode (LSB) Address (MSB) CommentB0 B1 B2 B3 A0 A1 A2 A3 1 IN1 (6A) 0 1 0 1 0 1 1 0 · Control data input mode, also referred to as “serial data input” mode.
- This is a 16-bit data input mode. 2 IN2 (6B) 1 1 0 1 0 1 1 0 · Control data input mode, also referred to as “serial data input” mode.
- This is a 16-bit data input mode. 3 OUT (6C) 0 0 1 1 0 1 1 0 · Data output mode, also referred to as “serial data output” mode.
- The data for multiple blocks can be output sequentially in this mode. CE CL DI DO B0 B1 B2 B3 A0 A1 A2 A3 First Data IN1/2 First Data OUT First Data OUT A12379 I/O mode determined For the CL normal high state For the CL normal low state
No. 5602-12/15 LC72722, 72722M, 72722PM Serial data input (IN1, IN2)tSU , tHD , tEL , tES , tEH ‡ 0.75 µs tLC < 1.15µs tCE < 20 ms CL: N ormal high CL: N ormal low tSU tHD tEL tES tEH tLC tCE B0 B1 B2 B3 A0 A1 A2 A3 FS0 CT1 FS1 FS2 SP0 FS3 SP1 EC3 TS0 EC4 TS1 CT0 TS2 TS3 CE CL DI Internal data A12380 tSU tHD tEL tES tEH tLC tCE B0 B1 B2 B3 A0 A1 A2 A3 FS1 FS0 CT1 FS2 SP0 FS3 SP1 EC3 TS0 EC4 TS1 CT0 TS2 TS3 CE CL DI Internal data A12381 Serial data output (OUT)tSU , tHD , tEL , tES , tEH ‡ 0.75 µs tDC , tDH < 0.46 µs tCE < 20 ms CL: N ormal high CL: N ormal low Notes:1. Since the DO pin is an n-channel open-drain output, the transition times (tDC , tDH ) will differ with the value of the pull-up resistor used. 2. The CE, CL, DI, and DO pins can be connected to the corresponding pins on other ICs that use the CCB interface. (However, we recommend connecting the DO and CE pins separately if the number of available microcontroller ports allows it.) 3. Serial data I/O becomes possible after the crystal oscillator starts oscillation. tSU tHD tEL tES tEH tDC tDC tCE B0 B1 B2 B3 A0 A1 A2 A3 1 0 1 0 D3 D2 D1 D0 CE CL DI DO A12382 tDH tSU tHD tDC tDC B0 B1 B2 B3 A0 A1 A2 A3 1 0 1 0 D3 D2 D1 D0 CE CL DI DO A12383 tDH tEL tES tEH tCE
No. 5602-13/15 LC72722, 72722M, 72722PM Serial data timing CL: N ormal high CL: N ormal low Old New tCE VIH VIL VIHVIL tEH tDH tLC tES tDC tEL tCL tCH tSU tHD VIH VIL VIH VIL VIH VIL VIH CE CL DI DO Internal data latch A12384 tCE VIH VIL VIL VIH VIL tEH tDH tLC tES tDC tDC tEL Old New tCLtCH tSU tHD VIH VIL VIHVIL VIHVIL VIL CE CL DI DO A12385 Internal data latch Parameter Symbol Conditions Ratings Unit min typ max Data setup time tSU DI, CL 0.75 µs Data hold time tHD DI, CL 0.75 µs Clock low-level time tCL CL 0.75 µs Clock high-level time tCH CL 0.75 µs CE wait time tEL CE, CL 0.75 µs CE setup time tES CE, CL 0.75 µs CE hold time tEH CE, CL 0.75 µs CE high-level time tCE CE 20 ms Data latch transition time tLC 1.15 µs Data output time tDC DO, CL 0.46 µs tDH DO, CE 0.46 µs Differs with the value of the pull-up resistor used.
No. 5602-14/15 LC72722, 72722M, 72722PM CE pin DO pin (Last data)-1 Last data New data T Tdo DO check (Tdo < T) A12386 2. When DO goes low 265 µs after data is read out Here, there is data that has not been read out remaining in the data buffer. In this case, applications are guaranteed to be able to read out that data without it being overwritten by new data if they start a readout operation within 20 ms of DO going low. (Note that this is the worst case condition.) Notes:1. Although an application can determine whether or not there is data remaining in the buffer by checking the DO level with the above timing, checking the RE and RF flags in the serial data is a preferable method. 2. Applications are not limited to reading out one block of data at a time, but rather can read out multiple blocks of data continuously as described above. When using this method, if an application references the RE and RF flags in the data while reading out data, it can determine the amount of data remaining. However, the length of the period for data readout (the period the CE pin remains high) must be kept under 20 ms. 3. If the DO pin is shared with other ICs that use the CCB interface, the application must identify which IC issued the readout request. One method is to read out data from the LC72722 and either check whether meaningful data has been read (if the LC72722 is not requesting a read, data consisting of all zeros will be read out) or check whether the DO level goes low within the 256 µs following the completion of the read (if the DO pin goes low, then the request was from another IC). CE pin DO pin (Last data)-2 (Last data)-1 Last data T Tdo DO check (Tdo < T) A12387 1. When the DO pin is high following the 265 µs period (Tdo) after data is read out Here, the buffer is in the empty state, i.e. the state where new data has not been written. After this, when the DO pin goes low, applications are guaranteed to be able to read out that data without it being overwritten by new data if they start a readout operation within 480 ms of DO going low. DO pin operation This IC incorporates a RAM data buffer that can hold up to 24 blocks of data. At the point where one block of data is written to this RAM, the IC issues a read request by switching the DO pin from high to low when SP = 00. (See the CCB input data fromat.) The DO pin always goes high for a fixed period (Tdo = 265 µs) after a readout and CE goes low. When all the data in the data buffer has been read out, the DO pin is held in the high state until a new block of data has been written to the RAM. (When SP = 00) If there is data that has not yet been read remaining in the data buffer, the DO pin goes low after the Tdo time has elapsed. After a synchronization reset, the DO pin is held high until synchronization is established. It goes low at the point where the IC synchronizes(When SP = 00).
PS No. 5602-15/15 LC72722, 72722M, 72722PM This catalog provides information as of May, 2002. Specifications and information herein are subject to change without notice. Specifications of any and all SANYO products described or contained herein stipulate the performance, characteristics,and functions of the described products in the independent state,and are not guarantees of the performance, characteristics, and functions of the described products as mounted in the customer’s products or equipment. To verify symptoms and states that cannot be evaluated in an independent device, the customer should always evaluate and test devices mounted in the customer’s products or equipment. SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety measures so that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. In the event that any or all SANYO products (including technical data, services) described or contained herein are controlled under any of applicable local export control laws and regulations, such products must not be exported without obtaining the export license from the authorities concerned in accordance with the above law. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or any information storage or retrieval system, or otherwise, without the prior written permission of SANYO Electric Co., Ltd. Any and all information described or contained herein are subject to change without notice due to product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification” for the SANYO product that you intend to use. Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use or any infringements of intellectual property rights or other rights of third parties. Sample Application Circuit Notes:1. Determine the value of the DO pin pull-up resistor based on the required serial data transfer speed. 2. If the SYR pin is unused, it must be connected to ground. + 1 24VREF SYR SYR 2 23MPXIN CE 3 22Vdda DI 4 21Vssa CL 5 20FLOUT DO 6 19CIN RDS-ID 7 18T1 SYNC 12 13XOUT XIN 10 µF MPXIN Vdda Vssa 8 T2 Vssd
9 T3NC NC
0.1 µF 15Vssd 14Vddd 0.1 µF Vssa
4.332 MHz
10 kΩ Vddd 10 kΩ RDS-ID SYNC Vddd 10 kΩ A12388