07 September 2010
Specification for LC band pass filter: L C 1 6 0 . 0 - 5 0 . 0 / 0 6 1. General 1.1. Package: 1.2. Type name: LC 160.0-50.0/06 1.3. Number of poles: 10 1.4. Operating temperature range ( OTR ): -20°C to +70°C 1.5. Storage temperature range: -30°C to +80°C time (s) temperature (°C) 260°C max. 260 217 Reflow soldering: three times max. max 300s 10,,,,,,30s 30,,,150s
- Electric values 2.1. Nominal centre frequency fo: 160.0 MHz 2.2. Pass band 2.2.1. Bandwidth at 3 dB: > fo ± 25.0 MHz 2.2.2. Ripple in pass band: < 2.0 dB ( peak to peak ) 2.2.3. Insertion loss: < 4.0 dB 2.2.4. Return loss ( Input / Output ) > 10 dB within 3-dB bandwidth 2.3. Stop band 2.3.1. fo ± 42.5 MHz: > 40 dB 2.3.2. fo ± 48.5 MHz: > 55 dB 2.3.3. Alternate attenuation: at DC..……..97 MHz > 80 dB at 220 MHz….1.0 GHz > 80 dB 2.4. Terminating impedance ( input and output ): 50 // 0 pF 2.5. Maximum power level ( working non-damaged ): +10 dBm / +20 dBm top view 3. Marking: 4. Environment conditions: Vectron MIL - standard 5. Packing: tape & reel, maximum 500 pcs. / reel OUT IN VECTRON YYWW LC 160.0-50.0/06