30 August 2010

Specification for LC band pass filter: L C 1 1 3 . 0 - 1 0 . 0 / 0 6 1. General 1.1. Package: 1.2. Type name: LC 113.0-10.0/06 1.3. Number of poles: 6 1.4. Operating temperature range: -40°C to +85°C 1.5. Storage temperature range: -55°C to +125°C 2. Electric values 2.1. Nominal centre frequency fo: 113.0 MHz 2.2. Pass band 2.2.1. Centre frequency fc at +25°C: 113.0 MHz 500 kHz 2.2.2. Bandwidth between 3 dB - frequencies: > fc

5.0 MHz

2.2.3. Ripple in pass band ( peak to peak ): < 1.0 dB 2.2.4. Insertion loss: 5.0 dB ( measured on smallest attenuation in pass band ) 2.3. Stop band 2.3.1. fc

7.0 MHz

2.3.2. fc

8.0 MHz

2.3.3. fc

9.5 MHz

2.3.4. fc

11.0 MHz

2.3.5. Alternate attenuation 80 dB 2.4. Terminating impedance ( input and output ): 50 // 0 pF 2.5. 3-rd order intermodulation products measured at 108.1 MHz: test tones 107.7 MHz / 107.3 MHz, power level -24 dBm: -110 dBm ( 86 dB down from test tones ) test tones 97.9 MHz / 103.0 MHz, power level -1.9 dBm: -110 dBm ( 86 dB down from test tones ) test tones 98.0 MHz / 87.9 MHz, power level +4.1 dBm: -110 dBm ( 86 dB down from test tones ) 2.6. Maximum input power level: +25dBm / +30dBm ( working / non-damaged ) 3. Marking: 4. Environment conditions: Corresponding to Vectron MIL Standard 202 VECTRON YYWW IN LC 113.0-10.0/06 OUT 601083-001 OR-002