LB8122A.1.EL < Interface between the I/O modules and the PCS/PLC < Mounting in Zone 2, Class I/Div.2 or in the safe area < Non-volatile memory for configuration and parameter settings < Communication via PROFINET < HART communication via HART I/P Function The PROFINET gateway is the interface between the I/O modules on the backplane and the control system. HART communication is via PROFINET or HART I/P. In addition to the input/output data of the I/O modules, the HART auxiliary variables can also be accessed in the process image. Connection Zone 2 Div. 2 COM COM µC PROFINET to I/O Technical Data Supply Connection backplane bus Rated voltage Ur 12 V DC , only in connection with the power supplies LB9*** Nominal voltage 12 V DC , Power dissipation 4.53 W Power consumption 4.53 W Fieldbus connection Fieldbus type PROFINET Ethernet Interface Connection type RJ-45 , via front connector Transfer rate 10BASE-T, 100BASE-TX 100 MBit/s Station connection directly to PCS or PLC or via hubs or switches Release date: 2021-11--

15 Date of

Release date: 2021-11-15 Date of issue: 2021-11-15 Filename: 70120382_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Cable type SFTP in accordance with ISO/IEC 11801 for Cat 5e or better Bus length max. 100 m per link Addressing DHCP, via controller (DCP) or fixed IP address Ethernet address IP V4 address (preset: DHCP on, changeable via display) Supported I/O modules LB1x01*…LB1x03*, LB1x08*, LB1x09*, LB2x01*…LB2x17*, LB3x01*…LB3x06*, LB4x01*, LB4x02*, LB4x04*…LB4x06*, LB5x01*, LB5x02*, LB5x04*…LB5x06*, LB6x01*, LB6x05*, LB6x06*, LB6x08*, LB6x10*…LB6x17*, LB7x04* HART communication via PROFINET and HART I/P PROFINET conformance class CC B Internal bus Connection backplane bus Galvanic isolation Ethernet/other circuits basic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC RS 485 interface/other circuits basic insulation according to IEC/EN 61010-1, rated insulation voltage 35 Veff or 50 V DC Insulation voltage 1500 V AC acc. to IEEE 802.3u Electrical isolation Power supply, internal bus/other circuits basic insulation according to IEC/EN 61010-1, rated insulation voltage 30 V DC Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Conformity Degree of protection IEC 60529 Fieldbus standard IEEE 802.3 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 (module) , mounted on backplane Connection via backplane Mass approx. 150 g Dimensions 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) Data for application in connection with hazardous areas Certificate DEMKO 16 ATEX 1780 X Marking 1 II 3 G Ex ec IIC T4 Gc Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018-07 EN IEC 60079-7/A1:2018-01 International approvals ATEX approval DEMKO 16 ATEX 1780 X IECEx approval IECEx UL 16.0141 X Gateway for PROFINET LB8122A.1.EL Release date: 2021-11-15 Date of issue: 2021-11-15 Filename: 70120382_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Approved for Ex ec IIC T4 Gc General information System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly OK NET L1 L2 LED red/green: Adapter Status LED red/green: Network Status LED green: Link Status Port 1 LED green: Link Status Port 2 Gateway for PROFINET LB8122A.1.EL Release date: 2021-11-15 Date of issue: 2021-11-15 Filename: 70120382_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091