< 2-channel < Simulation mode for service operations (forcing) < Mounting in Zone 2, Class I/Div.2 or in the safe area < Permanently self-monitoring < Output with watchdog < Module can be exchanged under voltage Function The device features 2 independent channels. The device can be used to switch solenoids, sounders, or lamps. The device can perform general switching operations, such as switching auxiliary power circuits. The outputs are galvanically isolated from the bus and the power supply. Connection Zone 2 COM I II Technical Data Slots Occupied slots 1 Supply Connection backplane bus Rated voltage Ur 12 V DC , only in connection with the power supplies LB9*** Power dissipation 0.65 W Power consumption 0.65 W Internal bus Connection backplane bus Interface manufacturer-specific bus to standard com unit Output Release date: 2021-12--

01 Date of

Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254825_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Connection channel I: 1-2 NC, 3; channel II: 4-5 NC, 6 Minimum load 1 V , 1 mA Relay Switching voltage DC: 30 V , AC: 230 V , 60 V (UL) Switching current 1 A DC / AC resistive load Switching power 30 VA / 30 W / 230 VA , 60 W (UL) Electrical life 0.5 Mio. cycles Response time 20 ms (depending on bus cycle time) Contact Material AgPd gold plated Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Digital output Number of channels 2 Field device interface Connection Relay output Connection channel I: 1-2 NC, 3; channel II: 4-5 NC, 6 Relay Switching voltage DC: 30 V , AC: 230 V , 60 V (UL) Switching current 30 VA / 30 W / 230 VA Switch power 30 VA / 30 W / 230 VA Minimum load 1 V 1 mA Electrical life 0.5 Mio. cycles Contact Material AgPd gold plated Response time 20 ms (depending on bus cycle time) Watchdog within 0.5 s the device goes in safe state, e.g. after loss of communication Indicators/settings LED indication Power LED (P) green: supply Status LED (1, 2) yellow: signal (per channel) Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Low voltage Directive 2014/35/EU EN 61010-1 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 when mounted on backplane Relay output LB6101H Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254825_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Connection removable front connector with screw flange (accessory) Mass approx. 90 g Dimensions 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) Data for application in connection with hazardous areas Certificate PF 08 CERT 1234 X Marking 1 II 3 G Ex nA nC IIC T4 Gc Galvanic isolation Output/power supply, internal bus safe electrical isolation acc. to EN 61010-1 Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 International approvals ATEX approval PF 08 CERT 1234 X UL approval E106378 IECEx approval BVS 09.0037X Approved for Ex nA nC IIC T4 Gc General information System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly P Front view Power LED green Socket for removable plug green (accessory) Status LED yellow per channel Relay output LB6101H Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254825_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091