LB1009A PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 3

Technical content

< 8-channel < Inputs Ex ic < Installation in Zone 2 or safe area < Dry contact or NAMUR inputs < Positive or negative logic selectable < Simulation mode for service operations (forcing) < Line fault detection (LFD) < Permanently self-monitoring < Module can be exchanged under voltage Digital Input Function The device accepts digital input signals of NAMUR sensors or mechanical contacts from the field. Furthermore it can accept active signals with 24 V or 5 V DC in the safe area. Open and short circuit line faults are detected. This does not apply for active signals. The inputs are galvanically isolated from the bus and the power supply. Connection COM Zone 2 I II III IV V VI VII VIII 10- 12- 11+ 14- 13+ 16- 15+ 10 kΩ 2.2 kΩ Technical Data Slots Occupied slots 1 Supply Connection backplane bus Rated voltage Ur 12 V DC , only in connection with the power supplies LB9*** Power dissipation 1.55 W Power consumption 1.55 W Internal bus Connection backplane bus Interface manufacturer-specific bus to standard com unit Digital input Number of channels 8 Release date: 2021-12--

01 Date of

Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 244407_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Connection [2] volt-free contact Connection [3] Usage without connection to areas where there is a risk of explosion: active signals, mechanical contacts, NAMUR proximity switches, 2-wire sensors If the device has been operated in general electrical systems that are not connected to areas where there is a risk of explosion, the device cannot then be used in electrical systems that are connected to areas where there is a risk of explosion. Usage with connection to areas where there is a risk of explosion: mechanical contacts, NAMUR proximity switches Rated values acc. to EN 60947-5-6 (NAMUR) Voltage 8.2 V Internal resistor Ri 1 kΩ Line fault detection can be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection Connection mechanical switch with additional resistors (see connection diagram) proximity switches without additional wiring Short-circuit < 360 Ω Open-circuit < 0.35 mA Digital signals (active) Use in safe area: configurable 24 V 5 V Switching point: ON > 8 V > 2.7 V Switching point: OFF < 3 V < 2.3 V Minimum pulse duration 15 ms Indicators/settings LED indication Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-8) red: line fault (lead breakage or short circuit) , yellow: signal (per channel) Coding optional mechanical coding via front socket Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 Conformity Electromagnetic compatibility NE 21 Degree of protection IEC 60529 Environmental test EN 60068-2-14 Shock resistance EN 60068-2-27 Vibration resistance EN 60068-2-6 Damaging gas EN 60068-2-42 Relative humidity EN 60068-2-56 Ambient conditions Relative humidity 95 % non-condensing Shock resistance shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 when mounted on backplane Mass approx. 90 g Digital Input LB1009A Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 244407_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091

Dimensions 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) Data for application in connection with hazardous areas Input Voltage Uo 10 V Current Io 12 mA Power Po 30 mW (linear characteristic) Certificate EXA 13 ATEX 0037X Marking 1 II 3 G Ex nA [ic] IIC T4 Gc Galvanic isolation Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010 International approvals ATEX approval EXA 13 ATEX 0037X IECEx approval EXA 13.0003X Approved for Ex nA [ic] IIC T4 Gc General information System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly I P Ex ic Front view Sockets for removable plug green (accessory) Status LED red/yellow per channel Power LED green Diagnostic LED red/white Accessories LB9131A Terminal Block Digital Input LB1009A Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 244407_eng.pdf Germany: +49 621 776 2222 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0002 Singapore: +65 6779 9091