C.A6470N CHAUVINARNOUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 256
Technical content
Datasheet sections
Datasheet sections
TEST & MEASUREMENT 2018
UNIVERSAL TEST & MEASUREMENT PHYSICAL & ENVIRONMENTAL MEASUREMENTS ELECTRICAL SAFETY RADIOFREQUENCY & MICROWAVE MEASUREMENTS ENERGY QUALITY & INSTALLATION MONITORING LABORATORY & EDUCATIONAL EQUIPMENT
Every story starts somewhere. The story of the Chauvin Arnoux company as an inventor and manufacturer of measurement instruments since 1893 is rich in developments and innovations. Today, its products bear witness to and reflect the sociological and technological changes and the industrial innovations which marked the previous century. A fascinating story that explains why and how Chauvin Arnoux’s image and personality evolved... in two colours. I t is often said that at the root of knowledge is language, or that the origin of an innovation was an idea,… yet it is the individual, the person, who is really the source of knowledge and discoveries. This also applies to electricity, which was not invented in the 19th century, but discovered in the 6th century BCE by a Greek philosopher and scientist named Thales, the first person to note the electrostatic properties of amber. From the beginning of the 19th century, there was the yellow of amber. Then manufactured goods began to include the yellow of brass and copper, materials used in measurement instruments, either for the casings of galvanometers or for the connections of electrical measurement instruments. Beige was also introduced with the use of varnished wood in the casings, while black was reserved for the instruments’ dials. Right from the start in 1893, the contrast between black and the yellow of varnished wood soon became the norm for the measurement instruments produced by Chauvin Arnoux. In a relatively short time, between 1900 and 1936, with the development of new technologies and new techniques for working materials , yellow brass began to be used with black Bakelite, eventually spreading to nearly all our instruments. Already known for its sense of design and the combination of its original colours yellow brass and 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM This calibration potentiometer dating from 1900 was used with a standard battery and a galvanometer like the one shown above. Its price was 195 francs! The Monoc L CdA 600 Polyclamp (1982) ABOUT THE CHAUVIN ARNOUX GROUP THE CHAUVIN ARNOUX GROUP Logo on the company’s former main gate gg l cocoloururss yyeyelllllowoww bbbrararasssss aandnd waswa 1895 reflection galvanometer 125 YEARS OF DEVELOPMENT
black, in its measurement instruments, Chauvin Arnoux reproduced these colours in its first corporate logo in 1927. In the 1940s, many measurement instruments only used black or black and the silver-grey of ferrous metals, sometimes painted. Chauvin Arnoux adapted its original visual identity to suit the fashions of the time, which also corresponded to technical criteria for safety, life-span extension or weight considerations linked to the metal and the manufacturing process used. The 1950s saw the arrival of rubber-like materials, used for the bases of portable instruments, and subsequently for the shockproof sheaths made of black neoprene, first designed and patented by Metrix® and Chauvin Arnoux in 1958. These shockproof sheaths later became widely used on the handheld instrument market. With the 1970s came plastics technology. This was when Chauvin Arnoux launched worldwide its first innovative products made of black and yellow plastic: the CdA 8 tester in 1979, the CdA 600 multimeter clamp in 1982, followed by the whole range. Some earth testers, such as the Terca in 1985 and the Prowatt wattmeters in 1989, also had a yellow casing. The combination of yellow and black for on-site equipment began to spread with its use for safety signage and for identifying hazardous areas on site… This encouraged Chauvin Arnoux to launch the well- known IMEG 500 or ISOL1 000 series in Europe and then in the United States with the company’s two colours. The MAN’X 500 series launched by Chauvin Arnoux , the very first multimeters made of a flexible material, further strengthened the company’s visual identity. At about the same time, Metrix launched several products with yellow casings and black platens, including the instruments in its MX 44 series (1988) followed by the MX 51 series. Over the years, Chauvin Arnoux has developed its visual identity across all its product ranges: its multimeters, wattmeters, megohmmeters and installation testers all bear the company’s colours One last remark about colours: while yellow is always seen as the colour of the sun and of certain kings or emperors in Asia, it is not so widely known that in physics, black is the symbol of a “black body”, meaning a system which absorbs all the light it receives. Black and yellow? A historic tandem for Chauvin Arnoux which was the first company to use this pairing for its corporate visual identity in the early 20th century when it first designed its logo in 1927. Axel Arnoux 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM On both the French MICA multimeter in 1985 and the ANAGRAF American version available the same year, the yellow of Chauvin Arnoux is clearly in evidence. MX 51 ABOUT THE CHAUVIN ARNOUX GROUP On both the Frenchh MIMICA multimimeteeter ir in 1198985 anandtd thhe ANAGRAGRAF American version availabablele theth same year, the yello Arnoux is clearly in evide
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM MEASUREMENT EXPERTS THE CHAUVIN ARNOUX GROUP A FEW FIGURES
- 100 million euros of sales revenues
- 10 subsidiaries across the world
- 1,000 employees
- 6 R&D departments worldwide
- 7 production sites
- 11% of revenues invested in R&D Founded in 1893 by Raphaël Chauvin and René Arnoux, CHAUVIN ARNOUX is an expert in the measurement of electrical and physical quantities in the industrial and tertiary sectors. Total control of product design and manufacturing in-house enables the Group to innovate constantly and to propose a very broad product and service offering meeting all its customers’ needs. The Group’s quality policy enables it to deliver products which comply with the specifications, as well as the international and national standards, in the metrological, environmental and user-safety sectors. 7 production sites 3 in Normandy 1 in Lyon 1 in Milan (Italy) 1 in Dover (USA) 1 in Shanghai (China) 11% of revenues invested in R&D
6 R&D departments
thriving! 10 subsidiaries Allemagne Autriche Chine Espagne Etats-Unis Italie Liban Royaume-Uni Suède Suisse expert measurement companies Portable test & measurement instrumentation Chauvin Arnoux®, Metrix®, Multimetrix® brands Design of optical sensors for quality control in laboratories & in-line processes. Metrology & regulatory testing Temperatures in industrial processes Metering, measurement & energy performance
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM CHAUVIN ARNOUX TEST & MEASUREMENT THE CHAUVIN ARNOUX GROUP In our laboratories, we carry out strict quality inspections and tests at each stage in the design and manufacturing processes: functional and metrological testing, mechanical and climatic testing, electromagnetic compatibility testing, electrical safety testing, ageing tests, etc. Electrical production, transmission, distribution, installation & maintenance Tertiary and industrial maintenance, diagnostics & testing “Eco Conception” eco-design label for product development based on an eco-friendly approach The Group’s ISO 9001 certification for the design processes and ISO 14001 certification for the manufacturing and sales processes demonstrate its determination to reconcile business and protection of the environment. Improvement of energy efficiency R&D and laboratory work Education KNOW-HOW ACKNOWLEDGED IN ALL SECTORS OF ACTIVITY QUALITY, STANDARDS AND ECO-RESPONSIBLE APPROACH CHAUVIN ARNOUX, the French international Group specialized in electrical measurement, relies on its Chauvin Arnoux® brand to propose a wide range of portable measuring instruments . Its offering covers:
- electrical measurement (testers, multimeters and current clamps)
- electrical safety testing (insulation testers, ohmmeters, earth/ground testers)
- power recording and analysis (wattmeters and network quality analysers)
- measurement of physical quantities (thermal cameras, luxmeters, sound level meters) Laboratory and educational instruments (training benches and cases) complete the scope of its expertise.
- Portable testers and multimeters
- Current clamps & multimeter clamps
- Insulation, earth and continuity testers
- Installation and electrical equipment testers
- Wattmeter-energy meters & electrical disturbance analysers
- Thermal cameras, thermometers, tachometers, field meters, luxmeters, etc.
- Recorders
- Training benches
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM COMMUNICATING WITH YOU, PUBLISHING & DIGITAL MEDIA FOR ADDITIONAL COMMUNICATION For Chauvin Arnoux, there is no need to choose between traditional or digital communication. The most important thing is to speak the same language as you! Due to its strong attachment to dialogue with all its partners and customers/prospects, the Chauvin Arnoux Group makes use of diverse print and digital media, giving priority to multi-channel communication. Whatever the device used, whether it is a smartphone, tablet or computer, Chauvin Arnoux offers users a website which guides them as they browse. It is simple to find, share and combine information, and offering more relevant information is an obvious target which the Group strives to achieve every day. Chauvin Arnoux, Chauvin Arnoux Energy, Pyrocontrole, Indatech and Manumesure: each of these entities presents the full extent of its offering through its products, its skills, its applications and its publications, backed by a common visual identity giving a structured image of the Group. A STRUCTURED WEBSITE This year, the Group will be proposing online sales of its main products. With just a few clicks, you will be able to order the products and accessories you need, which then be delivered directly to you or to a pick-up location. ONLINE SALES FROM 2018 Sales literature, catalogues, customer magazine, informative review for education: Chauvin Arnoux constantly strives to provide publications which meet your expectations. Nearly 50,000 copies of the magazine Contact Measurement News are distributed and it is also available in our distribution networks worldwide, presenting the Group's news through corporate and technical articles from the Group's five subsidiaries. It includes overviews of the standards, new applications, our production organization and our subsidiaries, providing transparent information which many of our customers have appreciated since the very first issue in black and white. PUBLICATIONS TO KEEP IN CONTACT N°67 ACTUALITÉS • MESURES CONTACT AUDITS ÉNERGÉTIQUES : NOUVEAU DÉCRET MARCHÉ : ÉLECTROCHIMIE, DES NOUVELLES PERSPECTIVES APPLICATIONS : SÉCURITÉ INCENDIE, RISQUES ÉLECTRIQUES PRESENT ON ALL THE SOCIAL MEDIA Follow all Chauvin Arnoux's news on the three main social media and our YouTube channel. Facebook www.facebook.com/ChauvinArnouxFrance Twitter twitter.com/ChauvinArnouxFr Linkedin www.linkedin.com/company/99353 Youtube www.youtube.com/c/chauvinarnouxgroup
WWW.CHAUVIN-ARNOUX.COM THE CHAUVIN ARNOUX GROUP 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM CHAUVIN ARNOUX, A LONG-TERM PARTNER FOR EDUCATION Drawing on its long history of close, privileged links with the French National Education system, the Chauvin Arnoux Group supports the players in education by participating in a large number of events, publishing the review "Les Cahiers de l’Instrumentation" and offering measuring instrumentation suited to the teaching requirements. A Measurement Certification and a dedicated website for students and teachers are also proposed to deal with the new constraints and to accompany tomorrow's professionals as closely as possible. The "Club du Mesurage" (Measurement Club) is a genuine think- ta nk brin gin g together experts from business a nd education in order to generate a constant flow of information about the evolution of the standards, the new market requirements, applications and particularly new applications… Open to all members of the Education sector, this Club allows genuine theoretical debate as well as creating a forum of expertise between two communities brought together by common objectives , leading every year to publication of Chauvin Arnoux's magazine for Education, "Les Cahiers de l’Instrumentation". To deal with the new constraints and to support tomorrow's professionals as closely as possible, CHAUVIN ARNOUX has set up a measurement certification programme, in cooperation with the French national education system. The aim of this certification is to confirm students' knowledge of the use of measuring instruments by means of an online multiple-choice questionnaire. The Chauvin Arnoux Group proposes a special dedicated offering for the world of education which is presented every year in the "Selection for Education" catalogue. The magazine "Les Cahiers de l’instrumentation" is a collection of practical exercises published annually for teachers and their students, providing concrete illustrations of solutions or the use of measuring, testing and energy control instruments. Every year, the Chauvin Arnoux Group acts as a partner and sponsor for a large number of events linked to the educational sector, intended to promote technical and scientific education by measuring equipment loans, the participation of Chauvin Arnoux managers in the judging panels or the provision of prizes for competitions. Discover Measurement Certification: certification-mesure.chauvin-arnoux.com THE" MEASUREMENT CLUB": A GENUINE FORUM FOR EXPERTISE! MEASUREMENT CERTIFICATION DEDICATED TO STUDENTS AND TEACHERS A PRODUCT OFFERING DEDICATED TO THE EDUCATION SECTOR "LES CAHIERS DE L’INSTRUMENTATION": THE MAGAZINE FOR EDUCATION PARTNER OF MANY EDUCATIONAL EVENTS CERTIFI CA TION MESURE DÉCOUVREZ LE SITE CERTIFICATION MESURE http://certification-mesure.chauvin-arnoux.com ELEECELEECELEECELEECELEECELEECELEEC ELEECELEECELEECELEECELEECELEECELEEC ELECELECELECELECELECELEC ELECELECELECELECELECELEC FEDFEDFEDFEDFEDFED FEDFEDFEDFEDFEDFED TMSECTMSECTMSECTMSECTMSECTMSECTMSECTMSEC TTMSECTMSECTMSECTMSECTMSECTMSECTMSEC TFCATFCATFCATFCATFCATFCAA TFCATFCATFCATFCATFCATFCA TTISECTISECTISECTISECTISECTISEC TTISECTISECTISECTISECTISECTISEC MSMSMSMSMSMSMS MSMSMSMSMSMS MEIMEIMEIMEIMEIMEI MEIMEIMEIMEIMEIMEI et un nouveau site web dédiés aux étudiants et enseignants BTS BACPRO
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM CHAUVIN ARNOUX, A CERTIFIED TRAINING ORGANIZATION SINCE 1993 The Chauvin Arnoux Group proposes six one-day training modules. Whether you need theoretical training or practical experience based around a product, choose the market leader to train you and your staff. New in 2016: a training course dedicated to energy auditing so that you perform the right measurements. UNDERSTANDING AND OVERCOMING HARMONICS
- The basics of harmonic phenomena.
- Identifying and characterizing the sources of disturbances.
- Measuring and detecting the phenomena in experimental conditions using a harmonic analyser.
- The applicable standards and labels.
- Understanding the effect of harmonics on the electrical components using real cases.
- How to deal with harmonic disturbances. ENERGY AUDITS: OPT FOR THE RIGHT MEASUREMENTS
- The advantages of energy auditing
- Economical, environmental and regulatory constraints
- People authorized to perform an energy audit
- Towards a continuous improvement process: the ISO 50001 standard
- Choosing the right measuring tool
- Defining the potential sources of energy savings and the related measurements
- Implementing appropriate solutions ELECTRICAL INSTALLATIONS AND NF C 15-100
- Properties and objectives of the earth/ground connection systems
- Behaviour of the earth/ground connection systems with regard to harmonics
- Insulation resistance measurement
- Electrical continuity measurements on protective conductors
- Resistance measurements on earth/ground electrodes
- Residual Current Device (RCD) testing ELECTRICAL INSTALLATIONS AND ENERGY QUALITY
- Excessive consumption of reactive energy leading to penalty payments.
- Loss of service continuity at the first fault on an IT system.
- Untimely tripping of the circuit-breakers protecting industrial electrical equipment.
- Untimely tripping of RCDs.
- Random fault on an electricity distribution system.
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM CERTIFICATION NUMBER 11.92.06217.92 - REFERENCED BY DATADOCK C.A 8336 NETWORK ANALYSER
- Setup and connections
- Presentation of the various measurements and functions: waveforms, harmonics, transients, alarms, etc.
- Recording and measurement campaigns
- Analysis of the measurement results
- Simulation exercise with the instrument on an electrical model THERMOGRAPHY
- Understanding heat exchange phenomena.
- Measuring with an infrared thermographic camera.
- Interpreting the measurements.
- Overview of all the applications of thermography and the current obligations. Detailed training schedule and registration form available from www.chauvin-arnoux.com or by sending a simple request to formation@chauvin-arnoux.com TRAINING IS AN ESSENTIAL ADVANTAGE IN ANYONE'S CAREER.
- Favouring skills development
- Gaining access to the different levels of qualification
- Obtaining authorizations Training provided on the Chauvin Arnoux Group's historic site in the 18th Arrondissement of Paris
- Expert training instructors acknowledged in their fields
- Innovative demonstration equipment to understand and operate
- Limited number of participants for high-quality discussions
APPLICATIONS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Measurements on pylons C.A 6474 On MV/HV lines C.A 6472 Separation of installations, voltage absence testing, phase sequence testing C.A 773 Testing of circuit-breakers and equipotential bonds C.A 6240 - C.A 6292 Soil resistivity and earth/ ground measurement C.A 6470N 15 kV insulation testing C.A 6555 Current measurements MA4000D EARTH/GROUND CONNECTION TESTING INSTALLATION MAINTENANCE AND TESTING
EARTH/GROUND CONNECTION TESTING THE CHAUVIN ARNOUX GROUP 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Analysis of electrical network quality (flicker, over- and undercurrent/ voltages/harmonics) C.A 8336 ENERGY SURVEY Electrical consumption monitoring PEL105 9 3 3
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Energy quality analysis C.A 8336 Testing for electrical or mechanical overheating C.A 1886 Noise C.A 834 Lighting C.A 1110 Humidity C.A 1246 Electric fields C.A 43 Recording of voltage drops and voltage surges L261 DETECTION OF ELECTRICAL DISTURBANCES INDUSTRIAL MAINTENANCE REGULATORY TESTING OF THE WORKING ENVIRONMENT 6 7 Electrical network
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Voltage absence testing C.A 762 IP2X Electrical cabinet testing C.A 6155 SAFETY OF PEOPLE MANUFACTURING QUALITY CONTROL Detection of leakage currents C.A 5275 + B102 Industrial machine testing C.A 6121 Earth/ground testing C.A 6417 Insulation testing C.A 6524
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Earth/continuity measurement C.A 6462 Comprehensive electrical safety testing on installations C.A 6116N REGULATORY TESTING AS PER IEC 60364-6 Measurement of insulation, leakproofing and thermal bridges C.A 1954 Energy performance of heating, ventilation and air-conditioning C.A 1052 CO 2 temperature and humidity testing C.A 1510 Recording and analysis of electrical consumption PEL103 ENERGY EFFICIENCY 62% 100% AVAILABLE MID-2018
HOUSING & TERTIARY THE CHAUVIN ARNOUX GROUP 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM GENERAL ELECTRICAL RENOVATION WORK Testing of the power supply and continuity of the electrical connections C.A 755 7 Detection and location of cables and metal conductors C.A 6681 8 Verification of voltages, currents and electrical continuity F201 9 Ionization current measurement on gas boiler C.A 5277 10
& MEASUREMENT Info and advice 20 Testers 24 Voltage detectors 28 Multimeters 31 Digital ammeters 40 Digital clamps 42 Accessories 46
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM THE STANDARDS EN 60529 The EN 60529 standard defines the level of tightness(leakproofing) of an instrument against penetration by solids or water. The IP rating corresponds to the instrument's level of protection against penetration by solids (1st digit) and by water (2nd digit). The higher the rating, the more effective the protection. A product without protection corresponds to a rating of IP00 (minimum rating), whereas a product totally protected against penetration by solids and liquids would have a rating of IP68 (maximum rating). IEC 61010 This international standard defines the safety rules for electrical measuring, control and laboratory instruments. It helps to ensure that the design and construction of the instruments protect users and their environment against: electric shocks, burns, mechanical hazards, the spread of fire from these instruments, excessive temperatures, etc. For some types of instrument, this standard is completed by specific instructions. The development of industrial and domestic equipment is increasing the hazards which may be encountered on an electrical installation, notably in terms of ever-higher voltage surges. On LV installations, where the voltages are limited to 1,000 VAC and 1,500 VDC, the hazard levels depend the type of installation and the voltage level. CAT II : Measurements on circuits connected directly to the low-voltage installation. Examples: domestic distribution system, portable or domestic appliances and equipment, mains power sockets. CAT III : Measurements on the building's installation. Examples: fixed installations involved in industrial distribution and the input circuits for electrical maintenance of a building (lighting, lift, etc.). CAT IV : Measurements at the source of the low-voltage installation. Examples: direct distribution circuit, primary sources, overhead-line and cable systems, including distribution busbars and the associated protective equipment against voltage surges. CAT II CAT III CAT IV
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM The international standards in the IEC 61010 family concern the safety rules for electrical measuring, control and laboratory instruments and their uses. More specifically, the IEC 61010-031 standard and its amendment A1 which define the safety rules for measuring instruments and accessories used with them. In the new edition which came into force on 1st March 2011, this standard has been completed with Chapter 13 covering "prevention of hazards linked to short-circuits and electric arcs": This addition stipulates the following rules for work on CAT III and CAT IV installations: Q The conductive part of test probes must not exceed 4 mm in length Q The external surfaces of the jaws of crocodile clips must be non-conductive and the conductive parts must not be accessible when the clip is closed. The IEC 61010-2-033 standard, first published on 09/02/2013, has brought changes concerning multimeters, multimeter clamps, etc. Since 9th March 2015, these instruments have had to guarantee a minimum safety level corresponding at least to CAT III 300 V. IEC 61557 This international standard specifies the electrical safety characteristics in 1,000 VAC and 1,500 VDC low- voltage distribution networks. It defines all the requirements for combined performance measurement and monitoring devices which measure and supervise the electrical parameters in electrical distribution networks. These requirements also define the performance levels in single and three-phase AC or DC networks with rated voltages less than or equal to 1,000 V AC or 1,500 V DC. The parts of the IEC 61557 standard applicable to our areas of test and measurement include: Part 1 : IEC 61557-1 : General Part 2 : IEC 61557-2 : Insulation resistance Part 3 : IEC 61557-3 : Loop impedance Part 4 : IEC 61557-4 : Resistance of earth conductors and equipotential bonding Part 5 : IEC 61557-5 : Resistance to earth Part 6 : IEC 61557-6 : Effectiveness of residual current devices (RCDs) in TT, TN and IT networks Part 7 : IEC 61557-7 : Phase sequence NF C 15-100 This is the official French safety standard concerning the protection of low voltage electrical installations , the protection of people and the ease of managing, operating and upgrading the installation. Installations in housing (house or apartment) must comply with this standard . In particular, NF C 15-100 defines the protective systems, RCD circuit-breakers, wiring, number and type of lighting points and number of power outlets in each type of room (bathroom, kitchen...), etc.
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM TECHNICAL REMINDERS In the specific case of a sinusoidal quantity, application of the relation above gives: Thus, for a 230 V/50 Hz network: V RMS = 230 V Vpeak = 325 V Vaverage = 207 V NUMBER OF COUNTS (FOR MEASUREMENT) This is one of the fundamental specifications of instruments using analogue-digital conversion. It is usually used to define the measurement range and the resolution , on the basis of the value chosen as the rated calibre. MEASUREMENT RANGE This indicates the limits within which a digital instrument maintains its specified characteristics. The measurements obtained are not subject to an error greater than the maximum tolerated error. It is defined by a minimum measurable value and a maximum measurable value. RATED CALIBRE The calibre of an instrument is the value of the quantity to be measured which corresponds to the upper limit of the measurement range. For example, for an ammeter, if this upper limit is 5 A, its calibre is said to be 5 A. RESOLUTION This is the smallest measurable value difference. It is also the value of one measurement count or unit of quantification which is usually termed the "unit". MINIMUM MEASURABLE VALUE (OR THRESHOLD) This is the smallest measurable value . For an instrument with excellent conversion linearity, it may be the same as the resolution. This is not always the case and the manufacturer should indicate it clearly, because this minimum value also depends on the accuracy, and particularly on the constant error. When the constant error is too high, it becomes impossible to obtain valid measurements of very low values. RMS: ROOT MEAN SQUARE The term RMS (Root Mean Square) refers to the effective value. By definition, the effective value of any current is the value of the DC current which would produce the same heating when flowing through a resistor. The amplitude (Vc) of a voltage or of a sinusoidal current is equal to √ 2 times its RMS value (Vc = √ 2 VRMS). It is crucial to know this RMS value in industrial environments ; it is this value which is used to define a current. For a sinusoidal AC voltage V peak = VRMS x √ Vaverage = 0.9 VRMS
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM SAFETY RULES AND GOOD PRACTICES Q Use measuring instruments and accessories which are suitable for the application and the measuring conditions. Prefer CAT IV instruments:
- They can withstand voltage surges which are up to 50 % greater than a CAT III product
- CAT IV 1000 V provides protection against electric shocks up to 12,000 V, while CAT IV 600 V instruments protect up to 8,000 V.
- Using a lower-category instrument means checking that the installation is equipped with protective systems (disconnecting switch, circuit-breaker, etc.) which are functional and in good condition. This is often the case… but not always!
- For outdoor or temporary installations or for installations upstream of the protective systems, CAT IV instruments must be used. Q It is the weakest element which defines your level of protection. If you use accessories of a lower category or with a lower voltage than your measuring instrument, the global level of safety offered by your measuring system will be reduced. Q Use accessories in perfect condition. Any accessory which is faulty, however slightly, must be replaced immediately as it can no longer guarantee your safety. Q The fuses are protective elements. If you replace them with cheaper models or, even worse, with a metal element (copper wire, aluminium foil, etc.), you will no longer be protected against possible voltage surges on your installation. An "average value" measuring instrument measures the average value of a sinusoidal current, after rectification and filtering, and displays the RMS value after applying a coefficient of 1/0.9 = 1.111 This indirect measurement method is simple and accurate but only valid for an undistorted sinusoidal current. It only tolerates distortion of a few percent. This is why "RMS" measuring instruments are increasingly widely used. They rely on direct measurement principles: the thermal method (used mainly in metrology) and analogue or digital calculation methods requiring sophisticated electronic components. PEAK VALUE – CREST FACTOR The crest factor is expressed as follows CF = Vpeak / VRMS This information complements the RMS value, allowing you to assess the distortion of a signal in qualitative terms. For a sinusoidal signal, CF = √ 2 = 1.414 ADVICE When we speak of a 230 V network voltage, we are referring to an RMS value. For many years, the level of distortion caused by linear loads (incandescent lamps, heating) connected to the network was very low. The spread of non-linear loads (switching power supplies, light dimmers, variable speed-drives or compact fluorescent lamps) is calling this approach into question, as "pure" sinusoidal currents are becoming increasingly rare on the network. Conventional measuring instruments (calculating the RMS value from the average value) are only accurate with sinusoidal currents, as a matter of principle. Otherwise, the measurement error may be as high as 50 %! You are advised to opt for "RMS" measuring instruments which are capable of providing correct measurements, whatever the waveform of the current or voltage.
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 732 page 25 C.A 745 N page 26 C.A 755 page 27 C.A 757 page 27 Strengths Built-in torch Moulded body for exceptional handling Phase test with a single test probe Continuity and resistance test Casing with built-in compartment for stowing the test probes Measurements up to 1,000 V MiniFlex® measurement accessory supplied Measurements up to 1,000 V Display Leds LCD bargraph Backlit digital display Backlit digital display Single-pole phase detection Q No-contact phase detection QQ Q AC or DC voltage QQQ Audible continuity QQQ Resistance QQQ Diode QQ Capacitance QQ Current Q Removable test probes QQQ 600V CAT III QQQ 1000V CAT III Q
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 732 Réf. : P01191745Z STRENGTHS Q No-contact phase detection Q Built-in torch Q Moulded body for exceptional handling
CONTENTS
Q C.A 732 delivered in blister pack with 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 46 SPECIFICATIONS C.A 732 Detection threshold 195 VAC ≤ U ≤ 265 VAC Audible beep U > 230 V Operating frequency 50/60 Hz Standards IEC 61010 1000 V CAT III Power supply 2 x 1.5 V LR03 batteries Dimensions / weight 176 x 26 mm / 48 g 1000 V CAT III
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 745 N Ref. : P01191743Z STRENGTHS Q No risk of tripping high-sensitivity RCDs during phase/earth testing Q C.A 745 N delivered in blister pack with 2 x 1.5 V LR03 batteries and 2 removable test probes (red/black) ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 46 SPECIFICATIONS C.A 745 N Voltage test 12 V to 690 V ~ (7 segments) Beep U > 50 V~ Impedance 400 kΩ Phase/neutral identification Flashing “Ph” diode and intermittent beep for U > 100 V~ Operating frequency DC and 50/60 Hz Polarity test “+” and “-” Voltage protection up to 1,100 V Audible continuity test R < 2 kΩ Resistance test 2 kΩ to 300 kΩ (3 segments) Standards IEC 61010 600 V CAT III Power supply 2 x 1.5 V LR03 batteries Dimensions / weight 180 x 52 x 45 mm / 200 g 600 V CAT III IP
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 755 - C.A 757 Ref. : P01191755 P01191757 STRENGTHS Q Measurements up to 1,000 V Q Backlit digital display Q Built-in compartment for stowing test probes in casing Q C.A 757: MiniFlex® measurement accessory supplied Q C.A 755 delivered with 1 set of extra-fine test probes CAT III/CAT IV (red/ black), 2 x 1.5 V LR3 alkaline batteries Q C.A 757 delivered with 1 set of extra-fine test probes CAT III/CAT IV (red/ black), 2 x 1.5 V LR3 alkaline batteries, 1 MiniFlex® sensor with a loop length of 250 mm, a connection cable 1 m long and a specific connector for C.A 757, 1 Velcro strap ACCESSORIES / REPLACEMENT PARTS Q 1 set of black/red CAT III/IV test probes _____________ P01102152Z Q See all the accessories on page 46 SPECIFICATIONS C.A 755 C.A 757 Current Measurement range via current sensor 500 mA to 300 A (2 calibres) Resolution 0.01 A to 0.1 A DC voltage Measurement range 3 mV to 1,000 V – 4 calibres Resolution 1 mV to 1 V AC voltage Measurement range 100 mV to 1,000 V – 4 calibres Resolution 1 mV to 1 V Operating frequency DC and 50/60 Hz Impedance 10 MΩ No-contact voltage detection 230 V 50/60 Hz conductor at a distance of approx. 5 cm Audible continuity test R ≤ 30 Ω Resistance Measurement range 0.3 Ω to 30 MΩ – 6 calibres Resolution 0.1 Ω to 0.01 MΩ Capacitance Measurement range 400 pF to 30 mF Resolution 0.001 nF to 0.01 mF Standards 600 V CAT III, IEC 61010-1, IEC 61010-031, IEC 61010-032, IEC 61010-033 Power supply 2 x 1.5 V batteries (LR03) Battery life 100 hours with alkaline batteries – Automatic standby after 10 minutes Dimensions / weight 180 x 52 x 45 mm / 200 g 600 V CAT III IP
CHOOSE YOUR VOLTAGE DETECTOR/VOLTAGE ABSENCE TESTER (VAT) UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 742 / IP2X page 29 C.A 762 / IP2X page 29 C.A 771 / IP2X page 30 C.A 773 / IP2X page 30 600V CAT IV QQ 1000V CAT IV QQ IP2X Version QQQQ Single-pole phase detection QQQQ AC or DC voltage test QQQQ Stray voltage detection QQ RCD tripping QQ Audible continuity QQQQ Extended continuity / Resistance QQQ 2-wire phase rotation QQQ Removable test probe QQQQ Compliant with IEC 61243-3 QQQQ Integrated Autotest QQQQ LED display QQQQ Digital display Q Extended climatic class Q IP65 QQQQ
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ADDITIONAL INFO Q Don't forget the adapter for 2P+E sockets STRENGTHS Q Full integrated Autotest Q Voltage test up to 690 Vac (16 2/3 – 800 Hz) / 750 Vdc Q IP2X versions available, compliant with NF C 18-510 Q Removable test probe and lead Q Phase-sequence testing up to 400 Hz Q 1 voltage detector delivered with: Q 1 black Ø 2 mm test-probe lead with crystal safety cap Q 1 red Ø 2 mm test-probe lead with crystal safety cap Q 1 wrist-strap Q 2 x 1.5 V LR03 batteries Q The IP2X version is delivered with: Q 2 x IP2X Ø 4 mm test probes (red/black) Q 1 black cable 1.10 m long equipped with a probe-holder system Q 1 wrist strap Q 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Q Crystal safety cap for Ø 2 mm test probe (x10) ________ P01102033 Q See all the accessories on page 46 C.A 742 - C.A 742 IP2X Ref. : P01191742Z P01191742D C.A 762 - C.A 762 IP2X Ref. : P01191762Z P01191762D SPECIFICATIONS C.A 742 C.A 762 Voltage detector Voltage 12 VAC ≤ U ≤ 690 VAC
12 VDC ≤ U ≤ 750 VDC
Frequency DC, 16 2/3 to 800 Hz Impedance > 300 kΩ > 400 kΩ Max. current 3.5 mA RMS Indication of polarity Yes Hazardous voltage indication The red ELV (Extra Low Voltage) LED indicates when the voltage is higher than the SELV (Safety Extra Low Voltage); the higher the voltage, the faster it flashes. Phase / Neutral identification Above 120 V (45 - 65 Hz) Above 400 V (16 2/3 - 45 Hz) Continuity with buzzer Trigger threshold 100 Ω typical (150 Ω max.) Extended continuity test - 2 kΩ, 60 kΩ, 300 kΩ Test current ≤ 1 mA Open-circuit voltage ≤ 3.3 V Protection Up to 1000 V Phase rotation No 2-wire method Ph/Ph voltage - 50 V ≤ U ≤ 690 VAC Frequency - Between 45 and 400 Hz Buzzer Intermittent beep for voltage detection and continuous beep for continuity Standards and electrical safety IEC 61010 600 V CAT IV IEC 61243-3 Ed.2 concerning Voltage Detectors/Voltage Absence Testers (VATs) IEC 61326-1, emission and immunity in industrial environments Protection of enclosure Casing: IP65 Test probes (option): IP2X Climatic conditions Use from -15 °C to +45 °C / 20 to 95 % RH Power supply 2 x 1.5 V batteries (AAA and LR03) Battery life 7,500 x 10 s measurements 7,000 x 10 s measurements Dimensions / weight 163 x 64 x 40 mm / 210 g IP IEC 61243-3 600 V CAT IV NF C 18-510 * Typical value with standard protective equipment (PPE)
VOLTAGE DETECTORS / VOLTAGE ABSENCE TESTERS (VATS) UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 771 - C.A 771 IP2X Ref. : P01191771 P01191771A C.A 773 - C.A 773 IP2X Ref. : P01191773 P01191773A STRENGTHS Q Full Autotest with indication of the type of fault Q Lighting of the point of measurement Q Automatic standby Q Extended climatic class Q IP2X version available, compliant with NF C 18-510 Q 1 voltage detector delivered with: Q 1 set of red/black Ø 2 mm removable test probes with crystal safety cap Q 1 test-probe protector Q 1 Velcro strap Q 2 x 1.5 V LR03 batteries Q The IP2X version is delivered with: Q 1 set of red/black IP2X Ø 4 mm removable test probes with crystal safety cap Q 1 Velcro strap Q 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Q C.A 753 measurement adapter for 2P+E sockets _______ P01191748Z Q See all the accessories on page 46 SPECIFICATIONS C.A 771 C.A 773 Display LEDs LEDs + Backlit digital display Voltage detection Voltage 12 VAC ≤ U ≤ 1000 VAC
12 VDC ≤ U ≤ 1400 VDC
Frequency DC, 16 2/3 to 800 Hz Impedance > 500 kΩ Max. current 3.5 mA RMS Polarity indication Yes Stray voltage detection Yes (by low-impedance load switching) RCD tripping Yes (by low-impedance load switching) Approx. 30 mA to 230 V Redundant hazardous voltage indication The ELV (Extra Low Voltage) LED indicates a voltage higher than the SELV (Safety Extra Low Voltage) with the flashing rate proportional to the voltage Phase / Neutral identification Above 50 V (45 - 65 Hz) Above 150 V (16 2/3 - 45 Hz) Continuity & Resistance Buzzer trigger threshold 100 Ω typical (150 Ω max.) 100 Ω typical (150 Ω max.) Extended continuity test (Resistance) 2kΩ, 60 kΩ, 300 kΩ 0,5 Ω to 2,999 kΩ Test current / Open- circuit voltage ≤ 1 mA / ≤ 3.3 V Phase rotation 2-wire method Ph/Ph voltage 50 V ≤ U ≤ 1000 VAC (45 - 400 Hz) Buzzer Intermittent beep for voltage detection / Continuous beep for continuity Standards and electrical safety IEC 61243-3:2009, EN 61243-3:2010 IEC 61010 1000 V CAT IV Enclosure protection IP65 Climatic conditions -30 °C to +60 °C (Extended "class S") -15 °C to +45 °C ("class N") Battery life > 5,000 x 10 s measurements > 2,500 x 10 s measurements Dimensions / weight 228 x 60 x 39 mm (without test probe) / 350 g approx. IP IEC 61243-3 NF C 18-510 1000 V CAT IV ADDITIONAL INFO Q Don't forget the universal measurement adapter for testing your 2P+E power sockets
CHOOSE YOUR ANALOGUE MULTIMETER UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 5001 page 32 C.A 5003 page 32 C.A 5005 page 32 C.A 5011 page 33 Analogue QQQQ Digital Q Anti-parallax mirror QQQ 4,000-count display Q Backlighting Q TRMS AC + DC measurement method Q Max Q Low-impedance calibre (LowZ) QQQ AC and DC current QQQQ Current via clamp Q μA calibre QQQ
5 A calibre Q
10 A calibre QQ
15 A calibre Q
Voltage presence LED in ohmmeter mode Q
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT III IP C.A 5001 - C.A 5003 - C.A 5005 Ref. : P01196521E P01196522E P01196523E STRENGTHS Q “Fus” LED: HRC fuse check Q “Voltest™” LED: voltage presence in ohmmeter* mode Q Automatic tare in ohmmeter mode* Q μA calibres Q Compact, shockproof casing with multi-purpose "Multistand™” articulated stand * for C.A 5003 and C.A 5005 Q C.A 5001 delivered with 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 1.5 V LR6 battery Q C.A 5003 delivered with 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 9 V 6LR61 battery Q C.A 5005 delivered with 1 MN89 AC clamp, 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 9 V 6LR61 battery ADDITIONAL INFO Q Also delivered complete in a hard case: Q The C.A 5005 is delivered with a current clamp for measurements up to
200 AAC
ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 46 SPECIFICATIONS (1) Additional “Voltest™” function to check for the possible presence of a voltage during resistance measurement and audible continuity test - (2) Use limited to 600 V max. (3) Limited to 240 A max. by the MN 89 miniclamp - (4) In % of end-of-scale - (5) Degree of pollution 2 - (6) Electronic protection and HRC fuses for the current calibres with fuse test LED. C.A 5001 C.A 5003(1) C.A 5005(1) DC voltage 8 calibres : 100 mV / … / 1000 V(2) AC voltage 5 calibres : 10 V / … / 1000 V(2) Internal resistance 20 kΩ/V Operating frequency 10 Hz … 100 kHz depending on calibre DC current 5 cal. : 50 μA / … / 5 A 7 cal. : 50 μA / … / 15 A 6 cal. : 50 μA / … / 10 A AC current 4 cal. : 5 mA / … / 5 A 5 cal. : 1.5 mA / … / 15 A 5 cal. :
3 A / … / 300 A(3)
Resistance 2 cal. : 10 kΩ and 1 MΩ Audible continuity test R < 50 Ω Scale in dB for VAC 0 … +22 dB Typical accuracy(4) 1.5 % for VDC • 2.5 % for VAC and AAC & • 10 % for Ω Power supply 1 x 1.5 V LR06 battery 1 x 9 V 6LR61 battery Battery life 10,000 x 15 s measurements 10,000 x 10 s measurements Electrical safety(5) IEC 61010-1 Edition 2 600 V CAT III Protection(6) HRC fuses
0.5 A and 5 A
1.6 A and 16 A
1 A and 10 A
Ingress protection IP 40 IP 53 Climatic conditions −10 °C … +55 °C and HR < 90 % Dimensions / weight 160 x 105 x 56 mm / 500 g
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT IV IP
53 TRMS
C.A 5011 Ref. : P01196311E STRENGTHS Q Extra safety with 2 LEDs: “Fus”: HRC fuse test, “Voltest™”: voltage presence in ohmmeter mode Q Two complementary readings: digital for accuracy, with backlighting, and analogue for quick reading Q Automatic AC/DC recognition Q Compact, shockproof casing with multi-purpose Multistand™ articulated stand Q 1 C.A 5011 multimeter Q 1 set of silicone straight banana plug/elbowed banana plug leads Q 1 set of safety test probes Q 1 x 9 V 6LR61 battery ADDITIONAL INFO Q Also available delivered complete in hard case: ACCESSORIES / REPLACEMENT PARTS Q PVC test-probe lead with insulated elbowed male plug Ø 4 mm (x 2) ________ P01295456Z Q See all the accessories on page 46 SPECIFICATIONS (1) Use limited to 600 V max. (2) Crest factor ≤ 5 – (3) Additional Voltest™ function to check for the possible presence of a voltage - (4) In digital mode. In analogue mode: 2.5 % – (5) Degree of pollution 2 – (6) Electronic protection and HRC fuses for the current calibres with fuse test LED. C.A 5011 DC and AC voltage 2 x 5 calibres 400 mV / … / 1000 V(1) Impedance 10 MΩ Operating frequency (2) 20 Hz / … / 10 kHz DC and AC current 2 x 6 calibres : 400 μA / … / 10 A Resistance (3) 6 calibres : 400 Ω / … / 40 MΩ Audible continuity test (3) R < 400 Ω Frequency 3 calibres : 4 kHz / … / 400 kHz Scale in dB for VAC -20 dB … +16 dB Max. value Sur 500 ms Typical accuracy (4) 1% for VDC and Ω, 1.5 % for ADC Power supply 1 x 9 V 6LR61 battery Battery life 300 hours Electrical safety (5) IEC 61010-1 Edition 2 600 V Cat IV Protection (6) 1 A and 10 A HRC fuses Ingress protection IP 53 Climatic conditions -10 °C … +55 °C and RH < 90 % Dimensions / weight 160 x 105 x 56 mm / 500 g
CHOOSE YOUR DIGITAL MULTIMETER UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 702 page 36 C.A 703 page 36 C.A 5231 page 37 C.A 5233 page 37 2,000-count display QQ 6,000-count display QQ Bargraph QQ Bi-mode bargraph (full scale - central zero) Backlighting QQ AVG measurement method QQ TRMS AC/DC measurement method QQ TRMS AC+DC measurement method Autoranging QQQQ Max. Q Peak AC and DC voltage up to 600 V QQ AC and DC voltage up to 1,000 V QQ No-contact voltage detection QQQQ Low-impedance calibre (LowZ) QQ LowZ voltage with low-pass filter AC and DC current QQ Current via clamp Q μA calibre Q
10 A calibre Q
CHOOSE YOUR DIGITAL MULTIMETER UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 5273 page 38 C.A 5275 page 39 C.A 5277 page 39 2,000-count display QQQ 6,000-count display QQQ Bargraph QQQ Bi-mode bargraph (full scale - central zero) QQQ Backlighting AVG measurement method QQQ TRMS AC/DC measurement method QQ TRMS AC+DC measurement method QQQ Autoranging QQQ Max. Q Peak AC and DC voltage up to 600 V QQQ AC and DC voltage up to 1,000 V No-contact voltage detection QQQ Low-impedance calibre (LowZ) QQQ LowZ voltage with low-pass filter QQQ AC and DC current Current via clamp QQ μA calibre QQQ 10 A calibre QQQ Resistance QQQ Audible continuity QQQ Semi-conductor test QQQ Frequency QQQ Capacitance QQ Temperature QQQ CAT III 1000 V QQQ CAT IV 600 V
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT IV IEC 61010-2-033 C.A 702 - C.A 703 Ref. : P01191739Z P01191740Z STRENGTHS Q Pocket format Q Built-in test probes Q Easy to handle and safe Q Built-in torch Q C.A 702 and C.A 703 delivered with: Q 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 46 SPECIFICATIONS C.A 702 C.A 703 Display 2,000 counts Calibre selection Automatic (AUTORANGE) VDC / accuracy 200 mV / ± 0.5 % R + 3 D 2.000 V; 20.00 V; 200.0 V; 600 V / ± 1.2 % R + 3 D > 600 V / outside specifications VAC / accuracy (40-400 Hz) 2.000 V; 20.00 V / ± 1.0 % R + 8 D 200.0 V; 600 V / ± 2.3 % R + 10 D > 600 V / outside specifications No-contact voltage detection Yes Yes IDC / accuracy Protection 200.0 μA; 2,000 μA ± 2.0 % R + 8 D 20.00 mA; 200.0 mA ± 2.0 % R + 8 D 200 mA / 500 V electronic fuse IAC / accuracy Protection 200.0 μA; 2,000 μA ± 2.5 % R + 10 D 20.00 mA; 200.0 mA ± 2.5 % R + 10 D Protection 200 mA / 500 V Electronic fuse Resistance • Accuracy
- Protection 200.0 Ω / ± 0.8 % R + 5 D 2.000 MΩ / ± 5.0 % R + 5 D 20.00 MΩ / ±10.0 % R + 5 D • 600 VRMS Diode test • Test signal
- Protection 1.999 V • VTest ≤ 1.5 V • ITest ≤ 1 mA • 600 VRMS Audible continuity
- Buzzer • Protection 199.9 Ω • R < approx. 60 Ω • 600 VRMS Torch Yes Yes Standards IEC 61010 1000 V CAT III / 600 V CAT IV Power supply 2 x 1.5 V LR03 batteries Miscellaneous Built-in test-probe leads Dimensions / weight 104 x 55 x 32.5 mm / 145 g
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 1000 V CAT III 600 V CAT IV IP IEC 61010-2-033 TRMS C.A 5231 - C.A 5233 Ref. : P01196731 P01196733 STRENGTHS Q Compact and ergonomic Q AC/DC voltage up to 1,000 V Q AC/DC current up to 600 A with 1,000/1 current clamp (option) Q C.A 5231 delivered with: Q 1 set of red/black test-probe leads Q 1 x 9 V 6LR61 battery Q C.A 5233 delivered with: Q 1 set of red/black test-probe leads Q 1 TC-K adapter for DMM Q 1 wire K thermocouple Q 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Q PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2) ___________ P01295456Z Q See all the accessories on page 46 SPECIFICATIONS C.A 5231 C.A 5233 Display 6,000-count display + 61-segment bargraph Backlighting Yes Acquisition True RMS AC Autorange / Manual range Yes / Yes Best accuracy 0.02 % AC voltage 6 calibres / 1,000 V / resolution: 0.01 mV LowZ AC voltage Yes DC voltage 6 calibres / 1,000 V / resolution: 0.01 mV AC/DC current With 1 AC or DC clamp (1 mV/A) as an option 1 calibre: 600 A Resolution: 0.1 A 2 calibres: 10 A / 6 A Resolution: 0.001 A Resistance measurement 6 calibres / 60 MΩ / resolution: 0.1 Ω Audible continuity / Diode test Yes / Yes Frequency Duty cycle 3 calibres: up to 3 kHz Yes Capacitance 6 calibres / 1,000 μF Resolution: 0.01 nF Temperature 2 calibres -20 °C to 760 °C -4 °F to 1,400 °F Resolution: 0.1° No-contact voltage detection (NCV) Yes Yes Display Hold Yes Yes Relative mode Yes Min-Max Yes Power supply 1 x 9 V 6LR61 battery Ingress protection IP54 Standards IEC 61010-1, IEC 61010-2-033 CAT IV
600 V / CAT III 1000 V
IEC 61010-1, IEC 61010-2-033 CAT IV
600 V / CAT III 600 V
Dimensions / weight 155 x 75 x 55 mm / 320 g ADDITIONAL INFO Q The C.A 5231 can also be delivered complete with its MINI03 100 AAC current clamp:
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM TRMS 1000 V CAT III 600 V CAT IV IEC 61010-2-033 IP C.A 5273 Ref. : P01196773 STRENGTHS Q Large 6,000-count display Q Double backlit display Q Temperature and capacitance measurements Q Bargraph central zero mode Q Min/Max memorization Q C.A 5273 delivered delivered with: Q 1 set of banana leads Q 1 set of test probes Q 1 x 9 V 6LR61 battery Q 1 K thermocouple temperature sensor ACCESSORIES / REPLACEMENT PARTS Q PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2) ___________ P01295456Z Q See all the accessories on page 46 ADDITIONAL INFO Q 5 measurements / s Q 12-bit converter Q 3-year warranty SPECIFICATIONS C.A 5273 Display 2 x 6,000 counts, backlit Bargraph (63 elements) Bi-mode (full scale / central zero) Acquisition TRMS AC / DC Measurement rate 5 measurements / second Automatic / manual ranges Yes / Yes AC/DC voltage 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1,000 V Typical accuracy (VDC) 0.2% + 2 cts Bandwidth (VAC) 40 Hz to 3 kHz LowZ AC voltage Low-impedance setting with Low-pass Filter AC/DC current 6.000 A / 10.00 A (20 A/30 s) Resistance measurement 600.0 Ω / 6,000 Ω / 60.00 kΩ / 600.0 kΩ 6.000 MΩ / 60.00 MΩ Audible continuity / Diode test Frequency 600.0 Hz / 6.000 kHz / 50.00 kHz Capacitance 8 cal.: 6.000 nF to 60.00 mF Temperature -59.6 °C to +1,200°C -4°F to +2,192 °F Hold Yes Min / MAX (100 ms) Yes Automatic power-off Yes (deactivatable) Safety IEC 61010-1, IEC 61010-2-033 CAT IV 600 V / CAT III 1000V Ingress protection IP54 Power supply 1 x 9 V 6LR61 battery Dimensions / weight 90 x 190 x 45 / 400 g
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM TRMS AC+DC 1000 V CAT III 600 V CAT IV IEC 61010 IP C.A 5275 - C.A 5277 Ref. : P01196775 P01196777 STRENGTHS Q 10 μV resolution Q Current measurement from 1 μA Q Measurement of ionization currents Q Min / Max / Peak+ / Peak- acquisition Q Differential (∆X) and relative (∆X / X%) measurements Q C.A 5275 delivered with a set of banana plugs, a set of test probes, a 9 V battery, a shoulder bag, a MultiFix mounting accessory and a startup guide Q C.A 5277 same as C.A 5275 plus a K-thermocouple temperature sensor ACCESSORIES / REPLACEMENT PARTS Q PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2) ___________ P01295456Z Q See all the accessories on page 46 SPECIFICATIONS C.A 5275 C.A 5277 Display 2 x 6,000 counts, backlit Bargraph 63 elements, bi-mode (full scale / central zero) Acquisition TRMS AC / DC / AC+DC Measurement rate 5 measurements / second Automatic / Manual ranges Yes / Yes AC/DC/AC+DC voltage 60.00 mV / 600.0 mV / 6 V / 60.00 V / 600.0 V / 1,000 V Typical accuracy (VDC) 0.09% + 2 cts Bandwidth (VAC) 40 Hz to 10 kHz LowZ AC voltage Low-impedance setting with Low-pass Filter AC/DC/AC+DC current 6,000 μA / 60.00 mA / 600.0 mA / 6.000 A /
10.00 A (20 A / 30 s)
Ionization current 0.2 μA to 20.0 μADC Resistance measurement 600.0 Ω / 6,000 Ω / 60.00 kΩ / 600.0 kΩ 6.000 MΩ / 60.00 MΩ Audible continuity / Diode test Yes / Yes Frequency 600.0 Hz / 6.000 kHz / 20.00 kHz Capacitance 6.000 nF / 60 nF / 600 nF / 6 μF / 60 μF / 600 μF / 6 mF / 60 mF Temperature No -59.6 °C to +1,200 °C -4°F to 2,192 °F Hold Yes Min / MAX (100 ms) Yes Peak+ / Peak- (1 ms) No Yes Differential (∆X) / RELative (∆X/X%) measurement No Yes Automatic power-off Yes (deactivatable) Safety IEC 61010-1, IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V Ingress protection IP54 Power supply 1 x 9 V 6LR61 battery Dimensions / weight 90 x 190 x 45 / 400 g ADDITIONAL INFO Q 5 measurements / s Q 12-bit converter Q 3-year warranty
CHOOSE YOUR AMMETER WITH FLEXIBLE CURRENT SENSOR UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM MA400D-170 page 41 MA400D-250 page 41 MA4000D-350 page 41 Clamping Ø 45 mm Q Clamping Ø 70 mm Q Clamping Ø 100 mm Q AC current QQQ TRMS QQQ 4,000-count display QQQ Max. Hold QQQ CAT IV 600 V QQQ
AMMETERS WITH FLEXIBLE CURRENT SENSORS UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM STRENGTHS Q Compact, stand-alone and easy to use Q Direct current readings Q Measurement from just a few tens of mA Q Memorization of maximum value Q 1 ammeter delivered with: Q 2 x 1.5 V LR06 batteries Q 1 Velcro mounting strap ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 46 SPECIFICATIONS MA400D-170 / 250 Display range 4 AAC 40 AAC 400 AAC Measurement range 0.020 A … Resolution 1 mA 10 mA 100 mA Accuracy ± (2% + 10 cts) ± (1.5% + 2 cts) ± (1.5% + 2 cts) Clamping Ø / Sensor length MA400D-170 : Ø 45 mm / 170 mm MA400D-250 : Ø 70 mm / 250 mm Bandwidth 10 Hz … 3 kHz Power supply 2 x 1.5 V LR03 batteries Safety IEC 61010 CAT IV 600 V Operating temperature 0°C to +50°C Instrument weight 130 g approx. Casing dimensions 100 x 60 x 20 mm Length of built-in connection cable 0.8 m MA4000D-350 Display range 40 AAC 400 AAC 4,000 AAC Measurement range 0.2 A … 39.99 A 40.0 A … 399.9 A 400 A … 3,999 A Resolution 10 mA 100 mA 1 A Accuracy ± (2% + 10 cts) ± (1.5% + 2 cts) ± (1.5% + 2 cts) Clamping Ø / Sensor length MA4000D-350 : Ø 100 mm / 350 mm Bandwidth 10 Hz … 3 kHz Power supply 2 x 1.5 V LR06 batteries Safety IEC 61010 CAT IV 600 V Operating temperature 0°C to +50°C Instrument weight 130 g approx. Casing dimensions 100 x 60 x 20 mm Length of built-in connection cable 0.8 m MA400D-170 - MAD400D-250 Ref. : P01120575Z P01120576Z MA4000D-350 Ref. : P01120577Z 600 V CAT IV TRMS
CHOOSE YOUR MULTIMETER CLAMP UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM F201 page 43 F203 page 43 F205 page 43 F401 page 44 F403 page 44 F405 page 44 F407 page 44 F603 page 45 F605 page 45 F607 page 45 Clamping Ø 34 mm QQQ Clamping Ø 48 mm QQQQ Clamping Ø 60 mm QQQ AC current QQQQQQQQQQ DC current QQ QQQQQQ Automatic zero DC QQ QQQQQQ TRMS measurement QQQQQQQQQQ Measurement with DC component (AC+DC) QQ Q Q Q Measurement on non-linear loads QQQQQQQQQQ 6,000-count display QQQ 10,000-count display QQQ Q x 3 QQ Q x 3 Backlighting QQQQQQQQQ AC and DC voltage measurement QQQQQQQQQQ Resistance QQQQQQQQQQ Audible continuity QQQQQQ QQ Semi-conductor test QQQQQQ QQ Frequency QQQQQQQQQQ Temperature QQ QQ Q Active power (W) QQ Q Q Q Apparent and reactive power (VA, var) QQ Q Q Q Power factor (PF/DPF) QQ Q Q Q Q Q AC / DC / AC+DC power measurement QQ Q Q Q Phase rotation (2 wires) QQQ Total Harmonic Distortion (THDf% / THDr%) QQ Q Q Q Harmonic decomposition (Harm0…Harm25) QQ Crest factor (CF) QQ Automatic deactivatable AC/DC QQQQQQQQQQ Motor InRush QQQQQQQQQQ Current surge with load (TrueInrush) QQQQQQQQQQ Min. QQQQQQQQQQ Max. QQQQQQQQQQ Peak QQ Q Q Q Differential measurement ∆X QQ QQ QQ Relative measurement ∆X/X QQ QQ QQ Adapter input (external probe) QQQ Data logging QQ PC interface / Bluetooth interface QQ CAT IV 600 V QQQ CAT IV 1000 V QQQQQQQ
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM F201 - F203 - F205 Ref. : P01120921 P01120923 P01120925
600 AAC
900 ADC TRMS 1000 V
Q Clamping Ø 34 mm Q Compact format Q Light weight Q TRMS AC+DC with the F205 clamp F201 delivered with: Q 1 set of built-in PVC test-probe leads (black/red) / insulated elbowed male banana plug Ø 4 mm Q 1 x 9 V 6LR61 battery Q 1 Multifix shoulder bag Q 1 mini-CD containing the User Manual F203 same as F201 plus 1 wire thermocouple with built-in insulated Ø 4 mm banana connections with 19 mm spacing F205 delivered with: Q 1 set of PVC leads (black/red) with insulated elbowed male banana plug Ø 4 mm / insulated straight male banana plug Ø 4 mm Q 2 test probes / insulated female plug Ø 4 mm (black/red) Q 1 safety crocodile clip (black) Q 1 x 9 V 6LR61 battery Q 1 Multifix shoulder bag Q 1 mini-CD containing the User Manual SPECIFICATIONS F201 F203 F205 Clamping Ø 34 mm Display LCD Backlit LCD Resolution 6,000 counts Number of values displayed 1 Type of acquisition TRMS AC TRMS AC/DC TRMS AC, DC, AC+DC Autorange Yes Automatic AC/DC detection Yes AAC 600 A ADC 900 A AAC+DC 600 A (900 A peak) Best accuracy 1 % R + 3 counts VAC 1,000 V VDC 1,000 V VAC+DC 1,000 V (1,400 V peak) Best accuracy 1 % R + 3 counts Frequency for V / I Yes / Yes Resistance 60 kΩ Audible continuity Adjustable from 1 Ω to 599 Ω Diode test (semi-conductor junction) Yes Temperature (type K) °C: -60.0 to +1,000 °C Adapter Yes Single-phase and total three-phase power values AC, DC, AC+DC Active (W) Reactive (var) Apparent (VA) Yes Yes Yes FP Yes Harmonic analysis THDf / THDr Yes / Yes Phase rotation (2-wire method) Yes Functions Overcurrent measurement Yes Motor InRush Yes Load evolution (TrueInrush) Yes Hold Yes Min / MAX Yes Peak+ / Peak- Yes RELative ∆X Differential ∆X/X(%) Yes Yes Yes Yes Auto Power Off Yes Electrical safety as per IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033
600 V CAT IV - 1000 V CAT III
Power supply 1 x 9 V 6LR61 battery Dimensions / weight 78 x 222 x 42 mm / 340 g
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM F401 - F403 - F405 - F407 Ref. : P01120941 P01120943 P01120945 P01120947 STRENGTHS Q Small and medium-power LV applications Q Clamping Ø 48 mm Q TRMS AC+DC with the F405 / F407 clamps Q Delivered in pre-equipped MultiFix shoulder bag F401 / F403 delivered with: Q 1 set of PVC leads (black/red) with insulated elbowed male banana plug Ø 4 mm / insulated straight male banana plug Ø 4 mm Q 2 test probes / insulated female plug Ø 4 mm (black/red) Q 1 wire thermocouple with built-in insulated Ø 4 mm banana connections with 19 mm spacing Q 4 x 1.5 V LR03 batteries Q 1 Multifix shoulder bag Q 1 mini-CD containing the User Manual F405 same as F401 / F403 without the wire thermocouple and with 1 safety crocodile clip (black) F407 same as F405 with: Q 2 safety crocodile clips (red/black) Q 1 mini-CD containing the Power Analyser Transfer PC software and the User Manual SPECIFICATIONS F401 F403 F405 F407 Clamping Ø 48 mm Display Backlit LCD Resolution 10,000 counts Number of values displayed 1 3 Type of acquisition TRMS AC TRMS AC/DC TRMS AC, DC, AC+DC Autorange Yes Automatic AC/DC detection Yes AAC 1,000 A ADC 1,500 A AAC+DC 1,000 A (1,500 A peak) Best accuracy 1 % R + 3 counts VAC 1,000 V VDC 1,000 V VAC+DC 1,000 V (1,400 V peak) Best accuracy 1 % R + 3 counts Frequency for V / I Yes / Yes Resistance 100 kΩ Audible continuity Adjustable from 1 Ω to 999 Ω Diode test (semi-conductor junction) Yes Temperature (type K) °C: -60.0 to +1,000 °C Adapter Yes Single-phase and total three-phase power values Yes Active (W) Reactive (VAR) Apparent (VA) Yes Yes Yes FP / DPF Yes / – Yes / Yes Harmonic analysis THDf /THDr Yes / Yes Frequency analysis No 25th order Phase rotation (2-wire method) Yes Functions Overcurrent measurement Yes Motor Inrush Yes Load evolution (TrueInrush) Yes Hold Yes Min / MAX Yes Peak+ / Peak- Yes RELative ∆X Differential ∆X/X(%) Yes Yes Yes Yes Auto Power Off Yes Data logging Yes Communication interface Bluetooth Electrical safety as per IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033
1000 V CAT IV - 1000 V CAT III
Power supply 4 x 1.5 V LR06 batteries Dimensions / weight 92 x 272 x 41 mm / 600 g 1 000 AAC 1 500 ADC TRMS IP 1000 V CAT IV True InRush IEC 61010-2-032 IEC 61010-2-033
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM F603 - F605 - F607 Ref. : P01120963 P01120965 P01120967 STRENGTHS Q High-power LV applications Q Clamping Ø 60 mm Q TRMS AC+DC with the F605 / F607 Q Delivered in pre-equipped MultiFix shoulder bag F603 delivered with: Q 1 set of PVC leads (black/red) with insulated elbowed male banana plug Ø 4 mm / insulated straight male banana plug Ø 4 mm Q 2 test probes / insulated female plug Ø 4 mm (black/red) Q 1 wire thermocouple with built-in insulated Ø 4 mm banana connections with 19 mm spacing Q 4 x 1.5 V LR03 batteries Q 1 Multifix shoulder bag Q 1 mini-CD containing the USER Manual F605 same as F603 without the wire thermocouple and with 1 safety crocodile clip (black) F607 same as F605 with: Q 2 safety crocodile clips (black/red) Q 1 mini-CD containing the Power Analyser Transfer PC software and the User Manual SPECIFICATIONS F603 F605 F607 Clamping Ø 60 mm Display Backlit LCD Resolution 10,000 counts Number of values displayed 1 3 Type of acquisition TRMS AC/DC TRMS AC, DC, AC+DC Autorange Yes Automatic AC/DC detection Yes AAC 2,000 A ADC 3,000 A AAC+DC 2,000 A (3,000 A peak) Best accuracy 1 % R + 3 counts VAC 1,000 V VDC 1,000 V VAC+DC 1,000 V (1,400 V peak) Best accuracy 1 % R + 3 counts Frequency for V / I Yes / Yes Resistance 100 kΩ Audible continuity Adjustable from 1 Ω to 999 Ω Diode test (semi-conductor junction) Yes Temperature (type K) °C: -60.0 to +1,000 °C °F: -76 to +1,832 °F Adapter Yes Single-phase and total three-phase power values Yes Active (W) Reactive (VAR) Apparent (VA) Yes Yes Yes FP / DPF Yes / – Yes / Yes Harmonic analysis THDf /THDr Yes / Yes Frequency analysis 25th order Phase rotation (2-wire method) Yes Functions Overcurrent measurement Yes Motor Inrush Yes Load evolution (TrueInrush) Yes Hold Yes Min / MAX Yes Peak+ / Peak- Yes RELative ∆X Differential ∆X/X(%) Yes Yes Yes Yes Auto Power Off Yes Data logging Yes Communication interface Bluetooth Electrical safety as per IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033 Power supply 4 x 1.5 V LR06 batteries Dimensions / weight 111 x 296 x 41 mm / 640 g TRMS IP 1000 V CAT IV True InRush 2 000 AAC 3 000 ADC IEC 61010-2-032 IEC 61010-2-033
ACCESSORIES / REPLACEMENT PARTS UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 5001, C.A 5003 and C.A 5005 Q C.A 801 single-channel temperature adapter __________ P01652401Z Q C.A 803 two-channel temperature adapter Q Shoulder bag no. 21 with strap (250x165x60 mm) ______ P06239502 C.A 5001 C.A 5003 C.A 5005 C.A 771, C.A 771 IP2X, C.A 773 and C.A 773 IP2X Q Crystal safety cap for test probe Ø2 mm (x10) _________ P01102033 Q C.A 753 universal measurement adapter TESTERS C.A 742, C.A 742 IP2X, C.A 762 and C.A 762 IP2X Q Measurement adapter for 2P+E socket, model C.A 751 _____ P01101997Z Q Universal measurement adapter for 2P+E socket, Q Crystal safety cap for test probe Ø2 mm (x10) __________ P01102032 Q Set of 2 leads 0.25 m and 0.85 m long Q Set of 2 leads 1.5 m long with Ø4 mm IP2X test probes ____ P01295462Z Q MultiFix shoulder bag, 120 x 200 x 60 mm _____________ P01298074 Q Soft case, 200 x 100 x 40 mm with belt clip ____________ P01298065Z Q 1 probe-holder cable 1.10 m long + 2 red/black ø 4 mm VOLTAGE DETECTORS ANALOGUE MULTIMETERS C.A 732 C.A 745N Q Set of red/black test probes - Ø 2 mm, CAT II _________ P01102153Z Q Set of red/black test probes - Ø 4 mm, CAT II _________ P01102154Z Q C.A 753 universal measurement adapter Q Bag compatible with MultiFix accessory, C.A 755, C.A 757 Q Set of black/red Ø 2 mm test probes, CAT II __________ P01102153Z Q Set of black/red Ø 4 mm test probes, CAT II __________ P01102154Z Q C.A 753 universal measurement adapter Q Bag compatible with MultiFix accessory,
ACCESSORIES / REPLACEMENT PARTS UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Q MultiFix multi-position mounting accessory __________ P01102100Z Q Moulded PVC lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2) ________ P01295451Z Q Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2) ____ P01295453Z Q PVC test-probe lead, insulated elbowed male plug (x 2) __ P01295456Z Q C.A 801 single-channel temperature adapter __________ P01652401Z Q C.A 803 two-channel temperature adapter C.A 5231 Q 400 AAC / 600 ADC PAC10 current clamp ____________ P01120070 C.A 5233, C.A 5273 and C.A 5277 Q Safety adapter and temperature probe, wire K sensor, C.A 5011 Q Moulded PVC lead with straight male plug/insulated Q Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2) ________ P01295453Z Q PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2) ___________ P01295456Z Q C.A 801 single-channel temperature adapter __________ P01652401Z Q C.A 803 two-channel temperature adapter DIGITAL MULTIMETERS
ACCESSORIES / REPLACEMENT PARTS UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM F200, F400 and F600 SERIES Q MultiFix multi-position mounting accessory __________ P01102100Z Q Moulded PVC lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2) ________ P01295451Z Q Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2) ____ P01295453Z Q PVC test-probe lead, insulated straight male plug Q PVC test-probe lead, insulated elbowed male plug F400 and F600 SERIES F201 and F205 F203 Q Safety adapter and temperature probe, wire K sensor, Q C.A 801 single-channel temperature adapter __________ P01652401Z Q C.A 803 two-channel temperature adapter F403 and F603 Q Safety adapter and temperature probe, wire K sensor, Q C.A 801 single-channel temperature adapter __________ P01652401Z Q C.A 803 two-channel temperature adapter F407 and F607 MA400D & MA4000D MULTIMETER CLAMPS FIND ALL OUR ACCESSORIES ON PAGE 230
UNIVERSAL TEST & MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM
ELELELLLLLLECECCEEECCCTTTTTRTRTRRRRRRRRRRRTRRRTRRTRTRTRRRRRTRRRTRRRTRTRRRRRRRRRRTRRRRRRRRRTRRRRTT ICICCCAAAALALLLLLLLLLLAALLAALLLLALLLLLALLLLLALLALL SSSSSSSSSSSSAFAFAFAFETETETETE YYYY TTTTTTTTTTEEEEEEXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTEE
Multimeter clamps for leakage current 77 Earth and resistivity testers 79 Electrical equipment testers 87 Other testers 91 Data processing software 100 Accessories 102
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY INFO AND ADVICE ELECTRICAL INSTALLATION TESTING The risks linked to incorrect use of electricity may include: -life-threatening danger for people, -threat of damage to electrical installations and property, -harmful effects on systems operation and equipment life spans. So the purpose of electrical installation testing is primarily to ensure that people and goods are kept safe and are protected in the event of a fault . It also facilitates preventive maintenance of installations , preventing serious faults which might prove expensive (production shutdown, etc.). T o g u a r a n t e e p e o p l e ’ s s a f e t y w i t h r e g a r d t o t h e s e installations and the electrical equipment connected to them, standards have naturally been developed and updated to take changes into account. The IEC 60364 standard and its various national equivalents published i n e a c h E u r o p e a n c o u n t r y , s u c h a s NF C 15-100 in France or VDE 100 in Germany, specify the requirements concerning electrical installations in buildings. Chapter 6 of this standard describes the requirements for testing the compliance of an installation. The effectiveness of the safety measures implemented ca n only be guara nteed if regular tests prove they are operating correctly. This is why the standards cover not only the initial verifications when installations are commissioned, but also periodic testing whose frequency depends on the type of installation and equipment, its use and the legislation in the country involved. In addition, the tests must be carried out with measurement instruments that comply with the IEC 61-557 European standard ensuring user safety and reliable measurements. The electrical testing is divided into 2 parts: 1. Visual inspection to guarantee that the installation complies with the safety requirements (presence of an earth electrode, protective devices, etc.) and does not show any visible evidence of damage. 2. Measurements There are 4 main measurements required: 1. Earth 2. Continuity 3. Insulation 4. Tests of protective devices To guarantee safety on residential or industrial electrical installations, one of the basic rules is that there must be an earth electrode. If there is no earth electrode, it may endanger people’s lives and damage electrical installations and property. When a large enough area is available to set up stakes, you should measure the earth with the traditional 3-pole method, also known as the 62 % method. When the 62 % method is not applicable, however, other methods can be used. There are many methods for measuring the earth (1P live earth, PH-PE loop impedance, selective earth with 1-clamp method, etc.), some more suitable than others, depending on the type of earth connection system, the type of installation (residential, industrial, urban, rural, etc.), the possibility of cutting off the power, the area available for planting stakes, etc. 1. EARTH The purpose of continuity measurement is to check the continuity of the protective conductors and the main and supplementary equipotential bonds. The test is carried out using a measuring instrument capable of generating a no-load voltage of 4 to 24 V (DC or AC) with a minimal current of 200 mA. The resistance measured must be lower than a threshold specified by the standard applicable to the installation tested, which is usually 2 Ω. As the resistance value is low, the resistance of the measurement leads must be compensated, particularly if very long leads are used. 2. CONTINUITY Example : Approximate measurement of earth resistance by the Zs (Ph-PE) loop measurement method in a TT-type earthing system
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY INFO AND ADVICE Good insulation is essential to prevent electric shocks. This measurement, usually carried out between active conductors and the earth, involves injecting a DC voltage, measuring the current and thus determining the insulation resistance value. The power must be switched off and the installation must be disconnected before perform i n g th i s test to ensure that the test voltage will not be applied to other equipment electrically connected to the circuit to be tested, particularly devices sensitive to voltage surges. According to the IEC 60364 standard, the minimum insulation resistance values must be as follows: Rated voltage DC test Insulation of circuit voltage resistance V V MΩ SELV or PELV 250 ≥ 0.5 ≤ 500 V including PELV 500 ≥ 1.0 > 500 V 1,000 ≥ 1.0 3. INSULATION Fuses / Circuit-breakers To check the specifications of the protective devices such as fuses or circuit-breakers, a fault loop impedance measurement is carried out to calculate the corresponding short-circuit current. A visual inspection can then be used to check that the sizing is correct. A fuse table directly integrated in certain installation testers can be used to check automatically that the fuses are correctly sized. Residual Current Devices (RCDs): types AC, A and B RCDs, which detect earth leakage currents, can be tested using two methods: - the basic test, also called a pulse test, which determines the trip time (in milliseconds) - the step test, which determines the trip time and trip current, thus detecting any RCD ageing. Type-B RCDs are designed to provide a specified response for DC-only leakage currents. A specific test is then required to check RCDs of this type. 4. TESTS OF PROTECTIVE DEVICES When testing low-voltage installations, other measurements are recommended (mandatory in some countries) such as: - The voltage drop ∆V% in the cables, obtained by means of two line-impedance measurements to check that their cross-sections are appropriate - The correct phase order in three-phase systems, thus ensuring that rotating machines turn in the right direction - The installation’s voltage and frequency , allowing identification of any poor connections Detection of phase current unbalance by measuring with a clamp and first-level assessment of the harmonic content are useful additions to any installation analysis. 5. OTHER RECOMMENDED MEASUREMENTS Example: RCD test via connection in a wall socket in TT-type earthing systems. RCD
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY INFO AND ADVICE To ensure that electrical equipment and installation operate correctly in total safety, all the conductors are insulated: sheathing for cables, varnish for windings. When the quality of these insulating materials diminishes, leakage currents may flow from one conductor to the other and, depending on the extent of the insulation faults (the worst being a short-circuit), may cause serious damage. Equipment with faulty insulation may break down, burn or cause a fault on the installation itself, thus triggering protective devices and shutting down the whole installation... Furthermore, some particularly sensitive installations (operating theatres in hospitals, chemical industries, etc.) are built using an IT-type earthing system (cf. IEC 60364- 6), which tolerates an initial line-earth insulation fault and only shuts down the installation if a second fault occurs. Measurements are needed to prevent and prepare for the hazards linked to insufficient or damaged insulation. These measurements concern both the electrical equipment and the installations to which it is connected. These measurements are carried out during commissioning on new or reconditioned items, and then repeated regularly to monitor their evolution over time. In concrete terms, first of all the installation or equipment is checked to ensure that no voltage is present in it. Then a DC test voltage is applied and the insulation resistance value is read. When measuring an insulation in relation to the earth, you are advised to place the positive pole of the test voltage on the earth to prevent earth polarization problems when carrying out multiple tests. All the standards concerning electrical installations or equipment specify the measurement conditions and minimum thresholds to be respected for insulation measurements. MEASURING LEVELS OF INSULATION These two concepts, which characterize the quality of an insulant, require further explanation as they are too frequently confused. Q Dielectric strength testing , also called “breakdown testing”, measures an insulant’s ability to withstand a medium-duration voltage surge without sparkover occurring. In reality, this voltage surge may be due to lightning or the induction caused by a fault on a power transmission line. The main purpose of this test is to ensure that the construction rules concerning leakage paths and clearances have been respected. This test is often performed by applying an AC voltage but can also be done with a DC voltage. This type of measurement requires a dielectrometer. The result obtained is a voltage value usually expressed in kilovolts (kV). Dielectric testing may be destructive in the event of a fault, depending on the test levels and the available energy in the instrument. For this reason, it is reserved for type tests on new or reconditioned equipment: only equipment that passes the test will be put into service. Q Insulation resistance measurement, however, is non- destructive under normal test conditions. Carried out by applying a DC voltage with a smaller amplitude than for dielectric testing, it yields a result expressed in kΩ, MΩ or GΩ. This resistance indicates the quality of the insulation between two conductors and provides a good idea of the risks of leakage currents. Because it is non-destructive, it is particularly useful for monitoring insulant ageing during the operating life of electrical equipment or installations. This means it can be used as a basis for preventive maintenance. This measurement is performed using an insulation tester, also called a megohmmeter. INSULATION RESISTANCE MEASUREMENT AND DIELECTRIC TESTING INSULATION MEASUREMENT
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY INFO AND ADVICE N M 100 m Insulation measurement on electrical installations Insulation test before powering up Before powering up a new installation, its insulation must be tested. Two types of measurements are required: - Verification of the conductors: this checks that none of the conductors, cut-off devices or connection equipment has suffered damage liable to cause an insulation fault. This is done before commissioning the installation, with all the receivers disconnected. - Verification of the whole installation in relation to the earth. INSULATION MEASUREMENT APPLICATIONS Insulation test after powering up After powering up the installation, the insulation should be checked regularly to make sure there is no substantial drift away from the initial values. Because the method used is the same as for testing before powering up, the installations must be switched off. In both cases, the insulation will be considered acceptable if the insulation resistance measured is greater than the threshold specified by the applicable standard for the installation tested (NF C 15-100 in France, VDE 100 in Germany, European standard IEC 60364, IEEE 43-2000, etc.) Insulation measurement on motors, transformers, etc. Whether on electrical installations or on machines, the quality of the insulating materials deteriorates as time passes due to the stresses affecting the equipment. This deterioration reduces the electrical resistivity of the insulants, leading in turn to an increase in the leakage currents and causing incidents which may be serious in terms of the safety of people and property, but also in terms of production stoppage costs in industry. So, in addition to the measurements durin g com m issionin g of new or renovated equipment, regular insulation testing of installations and equipment helps to prevent such incidents by organizing preventive maintenance designed to detect ageing and therefore prevent premature deterioration of the insulation properties before they reach a level liable to cause the incidents described above. Deterioration of the equipment may occur naturally, but it is often also accelerated by external contaminants such as dust, oil, etc. It is therefore strongly recommended to monitor its insulation over time. To carry out this preventive maintenance effectively, the Chauvin Arnoux range of megohmmeters proposes the following functions: - PI, DAR and DD quality ratios for a quick assessment of insulation quality, with the added advantage that they are not particularly influenced by temperature, making them easy to use without requiring correction of the results - Automatic calculation of the insulation resistance at a reference temperature (C.A 6549, C.A 6550, C.A 6555) - Method based on the influence of test voltage variation (step voltage measurement) CRITERIA FOR CHOOSING AN INSULATION TESTER Here are a few tips to help you choose an insulation tester that matches your requirements. Q The application. What type of equipment will you be testing: electrical installations, switchgear, telephony, etc. Rated operating voltage, manufacturer recommendations, dedicated standards Test voltage: 50 – 100 – 250 – 500 – 1,000 – 2,500 – 5,000 – 10,000 – 15,000 VDC Measurement range: kΩ, MΩ, GΩ, TΩ Q User comfort. Reading mode: needle display with logarithmic scale, digital LCD, analogue bargraph User-friendly features: programmable alarm thresholds, backlighting, remote control probe Q Operating mode. Hand-cranked generator, normal or rechargeable batteries Other measurements required: continuity, current, voltage, etc. Single-function or multi-function instrument, for testing installations or machines
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM EARTH MEASUREMENT For residential or industrial installations, the presence of an earth connection is one of the basic rules to ensure that the electrical installation is safe. The absence of an earth connection may endanger people’s lives and damage electrical installations and property. However, the presence of an earth connection does not guarantee safety and, even if the earth is correctly sized, only regular testing can ensure that it functions correctly. The standards for electrical installations, such as IEC 60364, NF C 15-100, etc., stipulate the general installation conditions to be applied in order to guarantee the safety of people, pets, farm animals and property by protecting them against the hazards and damage which may result from use of the electrical installations. When there is a large enough area available to set up stakes, earth measurement should be carried out with the traditional 3-pole method, also known as the 62 % method. There are a large number of different methods for earth measurements, however, and the right choice depends on the type of earthing system, the type of installation (residential, industrial, urban, rural, etc.), the possibility of switching off the power supply, the area available for setting up stakes, etc. Rural building with possibility of setting up stakes Urban building with no possibility of setting up stakes Single earth connection 3-pole method alias 62 % method Q Triangle method (2 stakes) Q 4-pole method Q Variant 62 % method (1 stake) Q Line-PE loop measurement Q Only with TT system Network of multiple parallel earths Selective 4-pole method Q Earth clamp Q Q Earth loop measurement with 2 clamps Q Q LIST OF THE DIFFERENT EARTH MEASUREMENT METHODS Here is an overview of the most frequently-used measurement methods: The 62 % in-line measurement method (two stakes) This method requires the use of two auxiliary electrodes (or “stakes”) to allow current injection and provide the 0 V reference potential. The positioning of the two auxiliary electrodes in relation to the earth connection to be tested E(X), is crucial. For correct measurements, the “auxiliary connection” providing the reference potential (S) must not be positioned in the areas influenced by earths E & H due to the flow of the current (i). Statistics from the field have shown that the ideal method for guaranteeing the highest possible measurement accuracy involves placing the stake S at a point 62 % of the distance from E on the line EH. You must then make sure that the measurement does not vary significantly when moving the stake S by ± 10 % (S’ and S”) on either side of its initial position, while remaining on the line EH. If the measurement varies, it means that (S) is in an influence area, so the procedure should be repeated after increasing the distances. For a correct measurement, the stake H should be at least 25 metres away from the earth to be tested. For more accurate measurement, it is possible to use
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Earth electrode to be tested R1 R2 Rn-1 Rn E S H ES C.A 6472RE Schematic diagram: earth clamp Schematic diagram: 2-clamp method PE N RCD Fuses / Circuit-breaker Rtransfo Rearth Note: on TN or IT (impedant) systems, the loop impedance measurement can be used to calculate the short-circuit current and thus to size the protective devices correctly. Selective earth measurements For interconnected earths, selective earth measurement can be used for quick, safe testing. In this case, it is not necessary to isolate the installation (no need to open the earth bar) and, for loop measurements with 2 clamps or with an earth clamp, it is not necessary to set up stakes. For the earth clamp and for the 2-clamp method, all you have to do to find out the earth value and the value of the currents flowing in it is clamp the cable connected to the earth. An earth clamp comprises two windings: a generator winding and a receiver winding: - The clamp’s “generator” winding develops an AC voltage at the constant level E around the clamped conductor; a current I = E / Rloop then flows through the resistive loop. - The “receiver” winding measures this current. - As E and I are known values, the loop resistance can be deduced from them. This case involves a network of parallel earths. Knowing that “n” resistances in parallel are equivalent to a resistance Raux with a negligible value, we can measure the local earth value Rx: Rloop = Rx + Raux (where Raux = resistance equivalent to R1…Rn in parallel) As Rx >> Raux’, we obtain the result Rloop # Rx The 2-clamp method is an equivalent method. One clamp acts as the generator, while the second acts as the receiver. This method may be more practical in places where access is difficult or when a larger clamping diameter is required. Line-PE loop measurement (only on TT system) In urban environments, it often proves difficult to measure earth resistances using auxiliary stakes because it is not possible to set up the stakes for reasons of space, concreting, etc. Loop measurement can then be used to test earths in urban environments without using stakes simply by hooking up to the mains power supply (mains socket). In addition to the earth to be measured, the loop resistance measured in this way includes the earth and internal resistance of the transformer and the resistance of the cables. As all these resistances are very low, the value measured is an overall earth resistance value. The actual earth resistance is therefore lower: Rmeasured > Rearth. The (overall) measurement error introduced by this method actually contributes to greater safety. The standards concerning electrical installations consider that the loop resistance (overall earth resistance) may be taken into account instead of the earth resistance to comply with the rules on protection against the risk of indirect contacts. a 4-pole measurement method (adding a connection between the earth to be tested and the ES terminal of the measurement instruments) to minimize the resistance of the measurement leads, thus improving accuracy. This method is strongly recommended for low resistance values as the influence of measurement-lead resistance will then be considerable. It is also possible to use the 4-pole + clamp method, which requires auxiliary stakes but allows precise measurement of the earth resistance.
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM SAFETY OF MACHINES, SWITCHBOARDS AND PORTABLE ELECTRICAL APPLIANCES The IEC 60204 / EN 60204 standard defines a machine as a set of parts or systems linked together, at least one of which is mobile. The fields of application are particularly diverse: machines for working metal, wood, textiles, printing, compressors, leather, tanneries, agricultural machinery, building sites and quarries, etc. Part 1 of this reference standard defines the general requirements regarding electrical machine safety to ensure the protection of people who may be exposed to hazardous phenomena due to failure of the electrical equipment or the command circuits, disturbances in the power sources or power circuits, loss of continuity in the circuits, electromagnetic disturbances, release of accumulated energy, excessive audible noise or excessive surface temperatures. To ensure electrical safety on the machines, you have to carry out a number of checks and tests after initial implementation, installation, renovation or modification and during periodic testing Q Checking of the protective automatic cut-off systems on the power supply in particular (the types of tests and checks depend on the earthing system):
- C h e c k i n g o f P E c o n t i n u i t y o n e a c h c i r c u i t i n t h e machine with a measurement current ≥ 200 mA which may be as high as 10 A,
- Verification of the loop impedance as per IEC 61557- 3 and correct coordination of the protection against overcurrents
- Visual check of the protection against overcurrents
- RCD testing as per IEC 61557-6, tripping-time test (recommended)
- Verification of the current at the first insulation fault by measurement or calculation Note: this test may be simplified depending on the condition of the machine as established by a questionnaire included in the standard. Q Insulation resistance measurement at 500 VDC, R > 1 MΩ Q Test of dielectric strength with 50 or 60 Hz AC voltage, at 2 x UN or 1,000 V, duration 1 sec (without disruptive discharge) Q Residual overvoltage test by measuring the discharge time < 1 sec or 5 sec. Q Operating test of the machine and the circuits involved in electrical safety Q The tests are usually performed in the order of decreasing failure in order to intercept electrical safety problems on the machine tested as quickly as possible. Other aspects of the machine may be checked, such as the conformity of the documentation, the temperature reached, the correct order of the phase sequence and the phase drop between the power supply and the load. The IEC 61439 / EN 61439 standard defines a set of low- voltage equipment as a combination of one or more low- voltage connection devices. A recent upgrade of this standard precisely defines the limits of liability between the original manufacturer, who should perform the design checks, and the assembler (switchboard operator) who should perform individual series testing. These checks include construction and performance tests. The switchboard operator is considered to become the original manufacturer if modifications are made to the low-voltage switchboard. A declaration of conform ity based on si m ple com pa rison with a si m i l a r switchboard will not be accepted, so a new check is necessary. This new context means that additional test equipment is needed to ensure compliance with the requirements of this reference standard. The tests required for low-voltage switchboards are: Q Physical measurement of the insulation gap or leakage distance Q PE continuity check with a measurement current ≥ 200 mA which may be up to 10 A (R ≤ 0.1 Ω) Q Short-circuit withstand by creating a bolted short-circuit Q Checking of the dielectric properties b y a t e s t a t 50 / 60 Hz with the application of a voltage between the different groups of terminals rising slowly and then held for 5 sec or 1 sec SWITCHBOARD SAFETY MACHINE SAFETY
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM INSULATION RESISTANCE MEASUREMENT DISCHARGE TIME By measuring the insulation resistance, it is possible to detect faults due to deterioration or pollution and mould. When the machines are disconnected, high-value capacitors may supply a hazardous voltage. This test measures whether the time taken by the discharge voltage to reach a non-hazardous value complies with the requirements (< 5s/< 1s). Measurement of Rinsulation in MΩ (IEC 61557-2) Disconnection TESTER Three-point connection PE N HV probe TESTER V DC TEST PE N The VDE 701 and VDE 702 standards define the inspections to be performed after repair or modification of the electrical appliances and the periodic inspections necessary, as well as general guidelines for electrical safety. This reference standard describes the automatic sequencing of the tests to be performed. Many of the tests and checks to be performed are identical to those described in the Machines and Switchboards section, plus certain tests “with probes” when the equipment does not have double insulation or reinforced insulation (Class I). Furthermore, the leakage current measurements must include leakage measurements by different methods (substitution method, differential leakage method, contact leakage method, etc.). The polarity of the mains leads must also be checked to ensure that it complies. SAFETY OF PORTABLE ELECTRICAL APPLIANCES MAIN TESTS & CHECKS Q Insulation test (variant) Other aspects can also be checked, such as the discharge time, the IP protection rating, the electrical circuits and connections (by random testing), identification of the external terminals, mechanical operation, shock voltage withstand, heating, etc. HV DIELECTRIC TEST The AC dielectric test can be used to confirm the device’s ability to function at its operating voltage. These tests are performed at a higher voltage than the normal operating voltage. AC dielectric strength HV probe TESTER V AC TEST PE N PE CONTINUITY TEST Used to check whether the resistance measured corresponds to the cross-section and length of the PE conductor. (IEC 61557-4) TESTER I-MEASUREMENT PE N RCD AND PRCD TEST The RCD test can be used to check operation of the RCDs. RCD test (Uc, T, I) (IEC 61557-6) TESTER Three-point connection PE N LOOP IMPEDANCE MEASUREMENT By measuring the loop impedance and calculating the prospective fault current (PFC), you can check that the automatic cut-off systems or fuses are appropriately sized. Loop & PFC measurement (IEC 61557-3) TESTER Three-point connection PE N RCD RCD
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM TECHNICAL OVERVIEW / OTHER TESTERS The measurement of low resistances is widely used in preventive maintenance to check the continuity of the chassis-earths, surface condition and metallization, the quality of the contacts in the switches and relays, the resistance of the cables and windings, to assess motor and transformer heating and, in general, to check the mechanical joints. A wide variety of fields are involved, including the automotive sector, telecommunications, transport, motor and transformer manufacturers, etc . as well as the repair and maintenance companies working in these different sectors. Measurement principle The basic principle for measuring resistance involves applying Ohm’s Law: U = R x I. When measuring very low resistances, a measurement current is injected and the resulting voltage is measured on the terminals of the resistance to be checked. The connections are the same as for 4-wire measurements, often called a Kelvin assembly, which limits the influence of the measurement leads when measuring low resistances. The connection diagram is shown opposite: From a DC voltage source U, a generator supplies a current with the value I. A voltmeter measures the v o l t a g e d r o p U x a t t h e terminals of the resistor Rx to be measured and displays Rx = Ux / I. The result is independent of the other resistances encountered in the current loop (Ri, Rf, Rc), as long as the total voltage drop which they cause with Rx remains lower than the voltage which the current source can supply. In practice, double retractable test probes, pivoting or otherwise, or Kelvin clamps are used for better contact with the object to be tested. Lastly, when measuring on a rivet, the two contacts of a given test probe must be capable of retracting by different amounts. The micro-ohmmeters must offer a resolution of 1 μΩ or even 0.1 μΩ, a wide measurement range and compensation of the thermocouple effects by inversion of the measurement current. To ensure operator safety, the equipment must be protected against accidental overvoltages, prevent measurement in the presence of a disturbance voltage and trigger automatic discharging after measurements on inductive objects. Lastly, as the resistance of metals changes significantly according to the temperature, it is a good idea to present the result at a given reference temperature. The instruments with the best performance automatically perform this calculation according to the type of metal, its temperature coefficient (approximately 0.4 %/°C for copper or aluminium), the ambient temperature and the reference temperature. MEASUREMENT OF LOW RESISTANCES Where: Ri = internal resistance of the instrument, Rf = resistance of the measurement wires, Rc = contact resistance, Rx = resistance to be measured Strict compliance with the primary / secondary ratio values of the voltage, power and current transformer is crucial because any variation of these values over time is a sign of problems in the transformer, s u c h a s i n t e r n a l d a m a g e , possible deterioration of the insulants due to mechanical damage or contamination or short-circuits between loops. In addition, accurate measurement of the excitation current can identify problems in the magnetic core of the transformer, such as type and thickness of the material, mechanical stresses and air-gap and assembly variations. By checking the winding polarity and the presence of open circuits or groups of term ina ls in open circuit, it is possible to detect rewiring errors after maintenance operations. Transformer ratio measurements performed using the method described in the IEEE C57.12-90 ™- 2006 reference document ensure standard, repeatable measurements. As such measurements are often performed in environments where a lot of noise is present, it is important for the operator to MEASUREMENT OF THE TRANSFORMER RATIO AND EXCITATION CURRENT H BLACK H RED X REDX BLACK
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Interconnection of several sections of the electrical network or several buildings on the same site in a three-phase system requires the phase sequence to follow the normal direction. This is particularly crucial for the power supplies of rotating machines as the rotation order of the phases connected determines the direction of the rotating field and therefore the rotation direction of the rotor. Phase rotation direction The phase rotation direction can be determined by connecting the three phases of the electrical network to be tested to the tester, in accordance with the markings. The tester then indicates the phase rotation direction : clockwise or anticlockwise. In this case, the tester is self-powered via the measurement inputs. To cover a wide range of applications, the equipment must be capable of operating at frequencies from 15 to 400 Hz. Rotating field direction or rotation direction without connection For some phase sequence detectors, the possibility of testing without connection, simply by positioning the tester on the casing of the motor, allows you to obtain a quick indication of the rotat i n g fiel d d i rect ion. In this mode, the tester must be set up in parallel to the rotor and in the prescribed direction. This principle is not valid when controlling a motor by means of a frequency converter. Determination of the phase connection direction on a motor If you connect the motor’s power supply phases to the tester and turn the rotor half a turn to the right by hand, the tester indicates whether or not the phase wires are connected in the right order. Indication of solenoid valve activation without connection On testers capable of testing without connection, the activation of a solenoid valve can be detected by placing the tester close to the valve. The clockwise or anticlockwise LED then indicates the direction of the field generated. be able to choose different filters in order to obtain more reliable results in such environments. Operator safety is ensured by a technique involving primary excitation, thus guaranteeing that no hazardous signal can occur at the secondary terminals of the transformer being tested. Storage of different “boilerplates” (specifications) in the instrument and direct display of the ratio value and its percentage deviation from the rated value help to speed up interpretation of the measurements performed. Their long battery life and their storage capacity for the results make digital ratiometers particularly useful for performing and analysing measurements. MOTOR DIRECTION AND PHASE ROTATION TESTS Research carried out by battery manufacturers has shown that the internal impedance of a rechargeable battery increases with its age and the number of discharges which it has undergone. By analysing the internal impedance, you can therefore assess the condition of the elements inside and determine whether the battery needs to be replaced or not. Instead of the absolute value of the battery’s internal resistance, it is the variation of the value which is important. Indeed, a 25% increase causes performance to fall by approximately 80%. These values may vary according to the battery technology involved. These values are compared with the instantaneous measurements made and noted when the batteries were installed. Preventive maintenance equipment should simultaneously measure and display the internal resistance by means of a 4-wire method for AC at a frequency close to 1 kHz, as well as the open-circuit voltage . As the internal resistance values measured may be low, you have to compensate the resistance of the measurement leads and retractable test probes. A large number of alarm comparison systems are used to quickly detect battery deterioration. On the basis of this comparison, the result is assessed and one of the LEDs (PASS, WARNING, FAIL) is then activated accordingly. BATTERY CAPACITY MEASUREMENT sensors source
TEXTECHOOSING YOUR INSTALLATION TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6030 page 63 C.A 6113 page 64 C.A 6116N page 64 C.A 6117 page 64 Insulation 50 / 100 / 250 / 1000 V QQQ RCD tests No-trip tests QQQQ Trip time (pulse) QQQQ Trip current (Ramp) QQQQ Management of standards or selective RCDs, type AC or A QQQQ Management of type-B RCDs Q Earth management 2P/3P earth QQQ 1P live earth (RA) QQQQ Selective earth with 1 clamp (RA Sel) QQQ Impedance & loop resistance Z-loop (L-PE) QQQQ Z-Line (L-N or LL) QQQ Ik calculation (PFC) QQQQ Isc calculation (PSCC) QQQ Integrated fuse table Q Voltage drop Q Resistance / Continuity Manual & automatic measurements QQQ Other functions Voltage / frequency QQQQ Current / leakage current on clamp QQQQ Phase sequence QQQQ Power values QQ Harmonics QQ Wiring polarity: test + reversal QQQ Alarms QQQQ Storage / Communication Storage QQ Q Storage of 3 tree-structure levels QQ Optical interface Q USB interface QQ Display and power supply Black and white LCD Q Black and white graphical LCD Q Colour graphical LCD QQ Online help QQQ Battery operation Q Operation with rechargeable batteries QNi-Mh QLi-ion QLi-ion PC software ICT/ DataView® QQ Transfer View Q Safety / Standards IEC 61010-1 600 V CAT III QQQQ IEC 61557 QQQQ
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6030 Ref. : P01191511 600 V CAT III IP STRENGTHS Q Dedicated to RCD testing Q Earth loop measurement without tripping the RCD Q Automatic detection of the L/N/PE positions on the mains socket Q Optical communication for data printing and transfer Q C.A 6030 delivered in a “neck-strap” bag with 1 shoulder bag for accessories containing 1 measurement lead with a European mains power socket, Q 1 measurement lead with 3 separate cables, Q 3 crocodile clips Q 3 test probes Q Data transfer software Q 1 optical communication cable ADDITIONAL INFO Q The C.A 6030 is delivered as standard with a European mains power socket Q It can also be delivered with a 1P loop-measurement kit: ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6030 Voltage measurement 2 to 550 V (DC or RMS) at connection Frequency 15.3 Hz to 450 Hz at connection Wiring polarity: test + inversion Yes RCD tests Rated voltage / frequency of the installation 90 to 550 V / 15.3 to 65 Hz I∆n 10 / 30 / 100 / 300 / 500 mA + variable from 6 mA to650 mA No-trip test ½ I∆n Trigger time I∆n, 2 I∆n, 5 I∆n, 150 mA, 250 mA Trigger current Step mode L-PE loop measurement (without RCD trip > 30 mA) Measurement of Z and R Rated voltage / frequency of the installation 90 to 550 V /15.3 to 65 Hz Measurement range 0.1 Ω to 4,000 Ω Accuracy 10 % of the value +15 cts Measurement current 0.1 to 0.5 I∆n Short-circuit current calculation (Isc) Up to 2.75 kA Live earth measurement (1 stake) (no RCD trip > 30 mA) Rated voltage / frequency of the installation 90 to 550 V / 15.3 to 65 Hz Measurement range 0.1 Ω to 4000 Ω Accuracy 10 % of value + 15 cts Measurement current 0.1 to 0.5 I∆n Phase rotation 90 < voltage present < 550 V Current / leakage current (with optional current clamp) MN20 clamp 5 mA to 20 A C172 clamp 5 mA to 20 A C176 clamp 50 mA to 200 A Cable compensation Yes Alarms In each function Memory 100 measurements Communication output Optical interface Power supply /Electrical safety 6 x 1.5 V batteries / IEC 61010-1 - 600 V CAT III Display Backlit 4,000-count LCD Dimensions / weight 211 x 108 x 60 mm / 0.9 kg
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT III IP STRENGTHS Q Tests on RCDs (types AC, A and B) Q Battery life of up to 30 hours Q Testing according to IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600… Q Automatic continuity measurement Q Colour screen (except C.A 6113) Q Measurements: voltage, current via clamp, power, waveforms and harmonics Q Loop measurement with 1 mΩ resolution Q C.A 6113 delivered in a shoulder bag with: Q 1 x PA 30 W power pack Q 1 Euro 3-point lead - 3 safety leads (red, blue, green) Q 3 test probes Ø 4 mm (red, blue, green) Q 3 crocodile clips (red, blue, green) Q 2 elbowed-straight safety leads (red and black) 3 m long Q 1 three-point Euro mains lead Q 1 remote-control probe Q 1 anti-scratch film mounted on the instrument Q 1 wrist-strap Q 1 x 4-point hands-free strap Q 1 CD-ROM containing the user manual Q C.A 6116N and C.A 6117 delivered in a shoulder bag with: Q 1 mains power / charger pack (type 2) Q 1 Li-Ion rechargeable battery pack mounted on the instrument Q 1 USB A/B cable 1.80 m long with ferrite Q 1 three-point lead - 3 safety leads (red, green and blue) Q 3 test probes Ø 4 mm (red, green and blue) Q 3 crocodile clips (red, green and blue) Q 2 elbowed-straight safety leads 3 m long (red and black) Q 1 three-point EURO mains lead Q 1 two-point EURO mains lead Q 1 remote-control probe Q 1 anti-scratch film mounted on the instrument Q 1 wrist-strap Q 1 x 4-point hands-free strap Q ICT data export software on CD-ROM Q 1 CD-ROM containing the user manual Q Three-point lead with separated wires 2.5 m __________ P01295398 Q Three-point lead for testing European mains sockets _____ P01295393 Q See all the accessories on page 102 ACCESSORIES / REPLACEMENT PARTS Q Integrated fuse table for quick result readings on the instrument Q User-friendly interface Q Extra-wide graphical screen Q Integrated contextual help for each function Q ICT data export software provided Q Compatible with the DataView® software Q Delivered as standard with a three-point European mains lead ADDITIONAL INFO C.A 6113 - C.A 6116N - C.A 6117 Ref. : P01145445 P01145455 P01145460 EFFECTIVE CONTEXTUAL HELP AND GUARANTEED SAFETY These testers are equipped with clear, detailed contextual help . This makes them suitable for both experts and less-experienced users. There is dedicated help for each measurement, including a guide to the connections to be set up and help for interpreting the results . For greater safety, if it is incorrectly connected or if a hazardous voltage is present, the instrument displays an error message in order to warn the user.
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM SPECIFICATIONS C.A 6113 C.A 6116N C.A 6117 Continuity / Resistance Measurement current I > 200 mA up to 39.99 Ω and 12 mA approx. up to 400 Ω Accuracy ± (1.5% of measurement + 2 cts), with audible beep Range 4kΩ / 40kΩ - 400kΩ Insulation Test voltage 50 /100 / 250 / 500 / 1,000 V DC Range / accuracy 0.01 MΩ to 2 GΩ / ±(5 % of measurement + 3 cts) Short-circuit current ≤ 3mA Earth 3P earth Range 0.50 Ω to 15 kΩ Accuracy ±(2 % of measurement + 2 cts) Others RH & RS auxiliary-stake resistance measurement (up to 40 kΩ) 1P selective earth Range / accuracy 0.20 Ω to 399.9 Ω ±(10 % of measurement + 10 cts) (ISel via clamp) Loop impedance (Zs (L-PE) and Zi (L-N or L-L)) – 1P live earth Live earth Installation voltage / freq. 990 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz High-current mode - Zs (L-PE) (TRIP) & Zi (L-N or L-L) Range / accuracy Max. test current: 7.5 A 0.100 Ω to 399.99 Ω / ±(5% of measurement + 2 cts) NO TRIP mode (Zs (L-PE)) Test current: 6 mA – 9 mA – 12 mA (as required) - 0.20 Ω to 3,999 Ω ±(5% of measurement + 2 cts) Calculation of short-circuit current Ik (PFC (Zs)) , I Sc (PSCC (Zi)) Fault and short-circuit current: display range 0.1 A to 6 kA Integrated fuse table Yes Voltage drop ∆U% (Zi) -40% to + 40% Others Measurement of the resistive and inductive components of the impedances Zs and Zi RCDs RCD types AC and A Installation voltage / freq. 90 V to 500 V / 15.8 Hz to 17.5 Hz and 45 Hz to 65 Hz I∆n 10/30/100/300/500/650/1000 mA (90V – 280V) or variable - 10/30/100/300/500 mA (280-550V) or variable Ramp and pulse test No-trip test ½ I∆n – Duration: 1,000 ms or 2,000 ms Trip current Ramp mode 0.3 x I∆n to 1.06 x I∆n per increment of 3.3% x I∆n Trip time measurement Pulse mode 0.2 à 0.5 x I∆n (Uf) / 0.5 x I∆n / 2 x I∆n (selective) / 5 x I∆n. Pulse: 0 to 500 ms, Ramp mode: 0 to 200 ms Type-B RCDs Installation voltage / freq. 90 V to 275 V / 15.8 Hz to 17.5 Hz and
45 Hz to 65 Hz
I∆n: ramp / pulse 2 x I∆n pulse 4 x I∆n 10/30/100/300/500 mA 10/30/100 mA Test in Ramp mode 0.2 x I∆n to 2.2 x I∆n Trip test 1.1x2 or 2.2x2 or 2.2x4 x I∆n Other measurements Current (1 mA*) 5.0 mA to 19.99 A (MN77 clamp) / 5.0 mA to 199.9 A (C177A clamp) Voltage 0 to 550 V AC/DC / DC and 15.8 to 500 Hz Frequency 10 to 500 Hz Phase rotation 20 to 500 VAC Active power 0 to 110 kW single-phase - 0 to 330 kW three-phase Simultaneous display of the voltage and current waveforms Harmonics Voltage and current / up to 50th order / THD-F / THD-R General specifications Large backlit LCD screen, 320 x 240 pts monochrome graphical 5.7 ‘’ colour graphical 5.7’’ Memory/Communication 1,000 tests, via USB for data transfer and report creation Power supply: rechargeable battery NiMH 9.6 V rated 4 Ah. Lithium-ion 10.8 V rated 5.8 Ah Battery life up to 24 hours up to 30 hours Dimensions / weight 280 x 190 x 128 mm / 2,2 kg Ingress protection / EMC IP 53 / IK04 / IEC 61326-1 Electrical safety / standards IEC 61010 -1 – 600 V CAT III – 300 V CAT IV – IEC 61557 *if a voltage is connected to the instrument
TEXTECHOOSE YOUR PORTABLE INSULATION TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6501 C.A 6503 C.A 6511 C.A 6513 C.A 6522 C.A 6524 C.A 6526 C.A 6532 C.A 6534 C.A 6536 F62 / F65 page 68 page 68 page 69 page 69 page 70 page 70 page 70 page 71 page 71 page 71 page 77 Type Hand-cranked Analogue Portable digital Test voltage (in VDC) 10 Q Q1 V increments 25 Q Q1 V increments
50 QQQ
100 QQQQ
250 Q QQQ Q
500 QQQQQQQ Q
1,000 Q QQQQ Max. measured value
200 MΩ Q
1 GΩ QQ
5 GΩ Q
20 GΩ QQ
40 GΩ Q
50 GΩ Q
200 GΩ QQ
Test duration programming QQQQQQ Quality ratios PI QQQ DAR QQQ Graphical Storage QQQQ Bluetooth QQQ Display Analogue QQQQ LCD + bargraph QQQQQQ Power supply Hand-cranked QQ Batteries QQQQQQQQQ
TEXTECHOOSE YOUR PORTABLE INSULATION TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6541 C.A 6543 C.A 6505 C.A 6545 C.A 6547 C.A 6549 C.A 6550 C.A 6555 page 72 page 72 page 73 page 74 page 74 page 75 page 76 page 76 Type On-site digital TEST VOLTAGE (IN VDC)
50 QQQQQQQQ
100 QQQQQQQQ
250 QQQQQQQQ
500 QQQQQQQQ
1,000 QQQQQQQQ 2,500 QQQQQQ 5,000 QQQQQQ variable from 50 to 5,100 QQQQQQ 10,000 QQ variable from 40 to 10,000 QQ 15,000 Q variable from 40 to 15,000 Q Max. measured value
4 TΩ QQ
10 TΩ QQQQ
25 TΩ Q
30 TΩ Q
Programming of test duration QQQQQQQQ Quality ratios PI QQQQQQQQ DAR QQQQQQQQ DD QQQQQ Graphical R (t) QQ QQQQQ u (t) + i (t) QQ i (u) QQ Ramp QQ Ramp by voltage steps QQQ R calculation (Tref) QQQ I limit QQ Early break / burn-in QQ Storage QQ QQQQQ RS 232 QQ Q USB QQ Display LCD + bargraph QQQQQ Graphical QQQ Power supply Batteries Q Rechargeable battery QQQQQQQ
TEXTEHAND-CRANKED INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Q C.A 6501 delivered in a shoulder bag Q 2 elbowed / straight PVC leads 1.5 m long (black/red) Q 2 crocodile clips (black/red) Q 1 black test probe Q C.A 6503 delivered in a shoulder bag Q 3 elbowed/straight PV leads 1.5 m long (black/red/blue) Q 3 crocodile clips (black/red/blue) Q 1 black test probe ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 C.A 6501 - C.A 6503 Ref. : P01132503 P01132504 STRENGTHS Q Rugged plastic casing ideal for all-terrain use Q Special for on-site use Q No power supply required SPECIFICATIONS C.A 6501 C.A 6503 Insulation Test voltage (DC) 500 V 250 V / 500 V / 1000 V Range 0.5 to 200 MΩ 1 to 5,000 MΩ Accuracy 2.5 % of full scale 2.5 % of full scale Resistance -Range 45 to 500 kΩ Accuracy 2.5 % of full scale Continuity -Range 0 to 100 Ω Accuracy 2.5 % of full scale Voltage Range 0… 600 VAC Frequency 45 to 450 Hz Accuracy 3 % of full scale Display Analogue Dimensions / weight 120 x 120 x 130 mm / 1.06 kg Power supply Hand-cranked magneto providing a stable voltage Ingress protection IP 54 with cover IP 52 without cover Electrical safety IEC 61010 - 600 V CAT II / 300 V CAT III 300 V CAT III IP
TEXTEANALOGUE INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT III IP C.A 6511 - C.A 6513 Ref. : P01140201 P01140301 STRENGTHS Q Simple to use Q Rugged thanks to their shockproof sheath ADDITIONAL INFO Q C.A 6511 : insulation at 500 V, continuity at 200 mA Q C.A 6513 : insulation at 1,000 V, continuity at 200 mA and resistance Q C.A 6511 and C.A 6513 delivered mounted in their shockproof sleeves Q 2 elbowed/straight PVC leads 1.5 m long (black/red) Q 1 black test probe Q 1 red crocodile clip Q 4 x 1.5 V LR06 batteries Q 1 replacement fuse ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6511 C.A 6513 Insulation Test voltage (DC) 500 V 500 V / 1000 V Range 0.1 to 1,000 MΩ Accuracy ± 5 % of measurement Resistance Range - 0 to 1,000 Ω Accuracy - ± 3 % of full scale Continuity Range −10 Ω to +10 Ω Accuracy ± 3 % of full scale Measurement current ≥ 200 mA Current reversal Yes Voltage Range 0… 600 V AC Frequency 45 to 400 Hz Accuracy ± 3 % of full scale Display Analogue Dimensions / weight 167 x 106 x 55 mm / 500 g (excl. sheath) Power supply 4 x 1.5 V LR06 batteries Electrical safety IEC 61010 - 600 V CAT III
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6522 - C.A 6524 - C.A 6526 Ref. : P01140822 P01140824 P01140826 STRENGTHS Q Test voltage from 50 to 1,000 V Q Measurement range from 10 kΩ to 200 GΩ Q PI and DAR ratios to determine the quality of the insulation Q Alarms and Pass/Fail indicator LEDs (C.A 6526) Q Storage of up to 1,300 measurements Q C.A 6522, C.A 6524 or C.A 6526 Q 1 “hands-free” bag Q 2 elbowed-straight safety leads (red and black) 1.50 m long Q 1 red crocodile clip Q 1 black test probe Q 6 x LR6 batteries Q 1 CD-ROM containing the multilingual user manual Q 1 safety datasheet in 20 languages Q In addition, for the C.A 6526: 1 CD-ROM containing the Megohmmeter Transfer software ACCESSORIES / REPLACEMENT PARTS Q 2 elbowed-straight safety leads (red and black) Q See all the accessories on page 107 SPECIFICATIONS C.A 6522 C.A 6524 C.A 6526 Industrial maintenance Voltage Measurement range / resolution 0.3 V - 399.9 V / 0.1 V; 400 V - 700 V / 1 V Accuracy / Input impedance ± (3 % + 2 cts) / 400 KΩ Operating frequency DC; 15.3 - 800 Hz Frequency Measurement range / resolution / accuracy - 15.3 Hz - 399.9 Hz / 0.1 Hz / ± (1 % + 2 cts) 400 - 800 Hz / 1 Hz / ± (1 % + 1 ct) Insulation Test voltage 250-500-1,000 V 50 - 100 - 250 - 500 - 1,000 V Range at maximum test voltage 40 GΩ 200 GΩ Compliance with IEC 61557-2 standard 2 GΩ Measurement range: 50 V - 10 kΩ - 10 GΩ
100 V - 20 kΩ - 20 GΩ
250 V 50 kΩ - 10 GΩ 50 kΩ - 50 GΩ
500 V 100 kΩ - 20 GΩ 100 kΩ - 100 GΩ
1,000 V 200 kΩ - 40 GΩ 200 kΩ - 200 GΩ Measurement range / resolution 10(1) - 999 KΩ and 1.000 - 3.999 MΩ / 1 KΩ; 4.00 - 39.99 MΩ / 10 kΩ 40.0 - 399.9 MΩ / 100 KΩ; 400 - 3,999 MΩ / 1 MΩ 4.00 - 39.99 GΩ / 10 MΩ; 40.0 - 200 GΩ / 100 MΩ Accuracy ± (3 % + 2 cts) (2) Test voltage (I < 1 mA) - 0 % + 20 % Test voltage display ± (3 % + 3 cts) Test current / resolution - 0.01 μA - 39.99 μA / 10 nA; 40.0 - 399.9 μA / 100 nA; 0.400 - 2.000 mA / 1 μA Test current accuracy - ± (10 % + 3 cts) PI/DAR ratios - 10 min / 1 min - 1 min / 30 s Timer (min:s) 0:00 - 39:59 Discharge time (at 25 V) < 2 s/μF Alarms - 2 fixed thresholds + 1 prog. threshold Continuity Continuity measurement range 0.00 Ω -10.00 Ω (200 mA) 0.00 Ω - 10.00 Ω (200 mA) 0.0 - 100.0 Ω (20 mA) Accuracy / Open-circuit voltage ± (2 % + 2 cts) / ≥ 6 V Measurement current 200 mA : 200 mA (- 0 mA +20 mA) - 20 mA : 20 mA ± 5 mA Continuity thresholds (fast beep) 2 Ω fixe 2 Ω, 1 Ω , programmable threshold Cable compensation Up to 9.99 Ω Resistance Measurement range / resolution - 0 - 3,999 Ω / 1 Ω 4.00 kΩ - 39.99 kΩ / 10 Ω 40.0 kΩ - 399.9 kΩ / 100 Ω 400 kΩ - 1,000 kΩ / 1 kΩ Accuracy ± (3 % + 2 cts) Capacitance Measurement range / resolution -- 0.1 nF - 399.9 nF / 0.1 nF 400 nF - 3,999 nF / 1 nF 4.00 μF - 10.0 μF / 10 nF Accuracy - - ± (3 % + 2 cts) Line length General specifications Display 2 x 4,000 cts + logarithmic bargraph Storage - 300 measurements 1,300 measurements Communication - - Bluetooth® Class II Power supply / automatic power-off 6 x LR6 batteries / 5 min, deactivatable Battery life 1,500 measurements : UN x 1 kΩ @ UN (5 s ON / 55 s OFF) 3,000 continuity measurements (5 s ON / 55 s OFF) Dimensions / weight / IP rating 211 x 108 x 60 mm / 850 g / IP 54 / IK 04 EMC / Electrical safety IEC 61326-1 / IEC 61010-1 and IEC 61010-2-030,
600 V CAT IV
Compliance with standards IEC 61557 parts 1, 2, 4 and 10 600 V CAT IV IEC 61557 IP
54 TRMS
(1): 2 kΩ for the C.A 6532, C.A 6534 and C.A 6536. (2): To be added: 10 V: 1 % per 0.1 GΩ; 25 V: 0.4 % per 0.1 GΩ, 50 V: 2 % per GΩ, 100 V: 1 % per GΩ; 250 V : 0.4 % per GΩ; 500 V: 0.2 % per GΩ; 1,000 V: 0.1 % per GΩ.
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM STRENGTHS Q Test voltage from 50 to 500 V Q Measurement range from 2 kΩ to 50 GΩ Q ∆Rel mode and configurable alarms Q Measurement of capacitance per unit length in nF/km (C.A 6532) Q 200 mA / 20 mA continuity with active fuseless protection Q C.A 6532, C.A 6534 ou C.A 6536 Q 1 “hands-free” bag Q 2 elbowed-straight safety leads (red and black) 1.50 m long Q 1 red crocodile clip Q 1 black test probe Q 2 wire grips (red/black) Q 6 x LR6 batteries Q 1 CD-ROM containing the multilingual user manual Q 1 safety datasheet in 20 languages Q 1 CD-ROM containing the Megohmmeter Transfer software (except C.A 6536) ACCESSORIES / REPLACEMENT PARTS Q 2 elbowed-straight safety leads (red and black) Q See all the accessories on page 107 SPECIFICATIONS C.A 6532 - C.A 6534 - C.A 6536 Ref. : P01140832 P01140834 P01140836 C.A 6532 C.A 6534 C.A 6536 Telecom Electronics Avionics, ESD, aerospace, defence Voltage Measurement range / resolution 0.3 V - 399.9 V / 0.1 V; 400 V - 700 V / 1 V Accuracy / input impedance ± (3 % + 2 cts) / 400 KΩ Operating frequency DC ; 15.3 - 800 Hz Frequency Measurement range / resolution / Accuracy 15.3 Hz - 399.9 Hz / 400 - 800 Hz / 1 Hz / ± (1 % + 1 ct) Insulation Test voltage 50 - 100 V 10-25-100- 250-500 V 10 to 100 V
1 V increments
voltage 20 GΩ 50 GΩ 20 GΩ Compliance with IEC 61557-2 std 2 GΩ Measurement range: 10 V 2 kΩ - 1 GΩ 2 kΩ - 2 GΩ
25 V 5 kΩ - 2 GΩ (UN/5) kΩ to
50 V 10 kΩ - 10 GΩ (UN/5) GΩ
100 V 20 kΩ - 20 GΩ 20 kΩ - 10 GΩ 20 kΩ - 20 GΩ
250 V 50 kΩ - 25 GΩ
500 V 100 kΩ - 50 GΩ
Variable test voltage 10 to 100 V Measurement range / resolution 10(1) - 999 KΩ and 1.000 - 3.999 MΩ / 1 KΩ; 4.00 - 39.99 MΩ / 10 KΩ 40.0 - 399.9 MΩ / 100 KΩ; 400 - 3,999 MΩ / 1 MΩ 4.00 - 39.99 GΩ / 10 MΩ; 40.0 - 200 GΩ / 100 MΩ Accuracy ± (3 % + 2 cts) (2) ± (3 % + 2 cts)(3) Test voltage (I < 1 mA) - 0 % + 20 % ± 0.5 V Test voltage display ± (3 % + 3 cts) Test current / resolution 0.01 μA - 39.99 μA / 10 nA; 40.0 - 399.9 μA / 100 nA 0.400 - 2.000 mA / 1 μA Accuracy of test current ± (10 % + 3 cts) PI/DAR ratios 10 min / 1 min - 1 min / 30 s -- Timer (min:s) 0:00 - 39:59 Discharge time (at 25 V) < 2 s/μF Alarms 2 fixed thresholds + 1 programmable threshold Continuity Continuity measurement range 0.00 Ω - 10.00 Ω (200 mA); 0.0 - 100.0 Ω (20 mA) Accuracy / open-circuit voltage ± (2 % + 2 cts) / ≥ 6 V Measurement current 200 mA : 200 mA (- 0 mA +20 mA) - 20 mA : 20 mA ± 5 mA Continuity thresholds (fast beep) 2 Ω, 1 Ω , programmable threshold Cable compensation up to 9.99 Ω Resistance Measurement range / resolution 0 - 3,999 Ω / 1 Ω ; 4.00 kΩ - 39.99 kΩ / 10 Ω / ± (3 % +2 cts) 40.0 kΩ - 399.9 kΩ / 100 Ω 400 kΩ - 1,000 kΩ / 1 kΩ / ± (3 % + 2 cts) Capacitance Measurement range / resolution 0.1 nF - 399.9 nF / 0.1 nF 400 nF - 3,999 nF / 1 nF 4.00 μF - 10.0 μF / 10 nF - - Accuracy ± (3 % + 2 cts) - - Line length 0 - 100 km - - General specifications Display 2 x 4,000 cts + logarithmic bargraph Storage 1,300 measurements - Communication Bluetooth® Class II - Power supply / Automatic power-off 6 x LR6 battery / 5 min, deactivatable Battery life 1,500 measurements: UN x 1 kΩ @ UN (5 s ON / 55 s OFF) 3,000 continuity measurements (5 s ON / 55 s OFF) Dimensions / weight / IP rating 211 x 108 x 60 mm / 850 g / IP 54 / IK 04 EMC / electrical safety IEC 61326-1 / IEC 61010-1 and IEC 61010-2-030, Compliance with standards IEC 61557 parts 1, 2, 4 and 10 600 V CAT IV IEC 61557 IP (1) : 2 kΩ for the C.A 6532, C.A 6534 and C.A 6536. (2) : To be added: 10 V: 1 % per 0.1 GΩ; 25 V: 0.4 % per 0.1 GΩ, 50 V: 2 % per GΩ, 100 V: 1 % per GΩ; 250 V: 0.4 % per GΩ; 500 V: 0.2 % per GΩ; 1,000 V: 0.1 % per GΩ. (3) : To be added: 10 % /UN per 100 MΩ
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 600 V CAT III IP C.A 6541 - C.A 6543 Ref. : P01138901 P01138902 STRENGTHS Q Test voltages from 50 V to 1,000 V Q Wide measurement range from 2 kΩ to 4 TΩ Q Automatic calculation of DAR / PI quality ratios Q Communication for C.A 6543 Q C.A 6541 delivered with an accessories bag containing: Q 1 set of 2 leads 1.5 m long (red/blue) Q 1 black guarded lead 1.5 m long Q 3 crocodile clips (red/blue/black) Q 1 test probe (black) Q 8 x LR14 batteries Q C.A 6543 delivered with an accessories bag containing: Q 1 set of 2 leads 1.5 m long (red/blue) Q 1 black guarded lead 1.5 m long Q 3 crocodile clips (red/blue/black) Q 1 test probe (black) Q 1 power-supply lead 2 m long Q 1 communication cable ADDITIONAL INFO Q Site-proof casing with highly shock-resistant lid Q Delivered with an accessories bag which can be clipped onto the site-proof casing ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6541 C.A 6543 Insulation Test voltage
50 V 2 kΩ to 200 GΩ
100 V 4 kΩ to 400 GΩ
250 V 10 kΩ to 1 TΩ
500 V 20 kΩ to 2 TΩ
1,000 V 40 kΩ to 4 TΩ Accuracy 2 kΩ to 40 GΩ ±5 % of value ± 3 cts
40 GΩ to 4 TΩ ±15 % of value ± 10 cts
duration 1 to 59 min. DAR (1 min. / 30 sec.) 0.000 to 9.999 PI (10 min. / 1 min.) 0.000 to 9.999 Adjustable PI Time adjustable from 30 s to 59 min. Voltage test / safety 0 to 1,000 V AC/DC Voltage alert indicator Yes > 25 V Test inhibition Yes > 25 V Smooth function Yes Continuity Range 0.01 to 39.99 Ω Measurement current ≥ 200 mA up to 20 Ω Resistance Range 0.01 to 400 kΩ Capacitance Range 0.005 to 4.999 μF Memory - Communication Storage of R(t) 20-kbyte memory 128-kbyte memory Storage of measurements 20 measurement results Up to 1,500 measurement results Direct report printing - On locally-connected printer, fixed format Communication port No RS232 PC software No DataView ® (option) Display Giant LCD + bargraph Giant LCD + bargraph Power supply 8 x LR14 batteries NiMH rechargeable battery Dimensions / weight 240 x 185 x 110 mm / 3.4 kg 240 x 185 x 110 mm / 3.4 kg Electrical safety IEC 61010 600 V CAT III – IEC 61557 IEC 61010 600 V CAT III – IEC 61557
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 1000 V CAT III 600 V CAT IV IP C.A 6505 Ref. : P01139704 STRENGTHS Q Fixed and programmable test voltages from 40 V to 5,100 V Q Wide measurement range from 10 kΩ to 10 TΩ Q Large LCD screen Q Automatic calculation of the DAR / PI quality ratios Q Measurement of voltage, capacitance and leakage current ADDITIONAL INFO Q Site-proof casing with highly shock-resistant lid Q Delivered with a shoulder bag CONTENU Q C.A 6505 delivered with a shoulder bag containing: Q 2 simplified measurement leads 2 m long, equipped with an HV plug at each end Q 1 guarded safety lead 2 m long, equipped with an HV plug at one end and an HV plug with rear connection at the other end Q 1 guarded safety lead 0.35 m long, equipped with an HV plug at one end and an HV plug with rear connection at the other end Q 3 crocodile clips (red, blue and black) Q 1 mains power-supply lead 1.80 m long ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6505 Insulation Test voltage
500 V 10 kΩ to 2 TΩ
1,000 V 100 kΩ to 4 TΩ 2,500 V 100 kΩ to 10 TΩ 5,000 V 300 kΩ to 10 TΩ Voltage programming 40 V to 1,000 V: 10 V increments 1,000 V to 5,100 V: 100 V increments Accuracy 1 kΩ to 400 GΩ ±5 % of value ± 3 cts
400 GΩ to 10 TΩ ±15 % of value ± 10 cts
Programming of test duration 1 to 59 min. DAR (1 min. / 30 sec.) 0.02 to 50.00 PI (10 min. / 1 min.) 0.02 to 50.00 Customizable PI Time adjustable from 30 s to 59 min. Voltage test / Safety 0 to 1,000 V AC/DC Voltage alert indicator Yes > 25 V Test inhibition Yes > 25 V Capacitance 0.001 to 49.99 μF Leakage current measurement 0.001 nA to 3 mA Display Giant LCD + bargraph Power supply NiMH rechargeable battery Dimensions / weight 270 x 250 x 180 mm / 4.3 kg Electrical safety IEC 61010 1000 V CAT III - 600 V CAT IV IEC 61557
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 7474 1000 V CAT III 600 V CAT IV IP STRENGTHS Q Fixed and programmable test voltages from 40 V to 5,100 V Q Wide measurement range from 30 kΩ to 10 TΩ Q Measurement filtering functions Q Automatic calculation of DAR / PI / DD ratios Q Storage and communication with the C.A 6547 Q C.A 6545 delivered with a shoulder bag containing: Q 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue) Q 1 guarded safety lead 3 m long with rear-connection HV plug and HV crocodile clip (black) Q 1 cable with rear connection (blue) 0.35 m long Q 1 mains power cable 2 m long Q C.A 6547 delivered with a shoulder bag containing: Q 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue) Q 1 guarded safety lead 3 m long with rear-connection HV plug and HV crocodile clip (black) Q 1 cable with rear connection (blue) 0.35 m long Q 1 mains power cable 2 m long Q 1 communication cable ADDITIONAL INFO Q Compatible with the DataView® software Q Delivered with a shoulder bag ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6545 C.A 6547 Insulation Test voltage
500 V 30 kΩ to 2 TΩ
1,000 V 100 kΩ to 4 TΩ 2,500 V 100 kΩ to 10 TΩ 5,000 V 300 kΩ to 10 TΩ Voltage programming 40 V to 1,000 V: 10 V increments 1,000 V to 5,100 V: 100 V increments Accuracy 30 kΩ to 40 GΩ ±5 % of value ± 3 cts
40 GΩ to 10 TΩ ±15 % of value ± 10 cts
duration 1 to 59 min. DAR (1 min. / 30 sec.) 0.02 to 50.00 PI (10 min. / 1 min.) 0.02 to 50.00 Customizable PI Time adjustable from 30 s to 59 min. DD 0.02 to 50.00 Voltage test /Safety 0 to 1,000 V AC/DC Voltage alert indicator Yes > 25 V Test inhibition Yes – Adjustable according to test voltage Smoothing function Configurable – Digital filtering stabilizing the measurements Capacitance 0.005 to 49.99 μF Leakage current measurement 0.001 nA to 3 mA Memory – Communication Storage of R(t) 4-kbyte memory 128-kbyte memory Storage of measurements 20 measurement results Up to 1,500 measurement results Direct report printing No On locally-connected printer, fixed format Communication port No RS232 PC software No DataView ® (option) Display Giant LCD + bargraph Power supply NiMH rechargeable battery Dimensions / weight 270 x 250 x 180 mm / 4.3 kg Electrical safety IEC 61010 1000 V CAT III - 600 V CAT IV - IEC 61557 C.A 6545 - C.A 6547 Ref. : P01139701 P01139702
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 7575 1000 V CAT III 600 V CAT IV IP C.A 6549 Ref. : P01139703 STRENGTHS Q Calculation of the resistance at a reference temperature Q Graphical display of R(t) curves Q Fixed and programmable test voltages from 40 V to 5,100 V Q Wide measurement range from 30 kΩ to 10 TΩ Q Test by voltage ramp Q C.A 6549 delivered with a shoulder bag containing: Q 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue) Q 1 guarded safety lead 3 m long with rear-connection HV plug and HV crocodile clip (black) Q 1 cable with rear connection (blue) 0.35 m long Q 1 mains power cable 2 m long Q 1 communication cable ADDITIONAL INFO Q Compatible with the DataView® software Q Delivered with a shoulder bag ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6549 Insulation Test voltage 1,000 V 100 kΩ to 4 TΩ 2,500 V 300 kΩ to 10 TΩ 5,000 V 300 kΩ to 10 TΩ Voltage programming 40 V to 1,000 V: 10 V increments 1,000 V to 5,100 V: 100 V increments Automatic voltage increments Programmable value and duration up to 5 steps, three profiles stored Accuracy 30 kΩ to 40 GΩ ±5 % of value ± 3 cts test duration programming 1 to 59 min. DAR (1 min. / 30 sec.) 0.02 to 50.00 PI (10 min. / 1 min.) 0.02 to 50.00 Customizable PI Time adjustable from 30 s to 59 min. DD 0.02 to 50.00 Voltage test / Safety 0 to 1,000 VAC/DC Voltage alert indicator Yes > 25 V Test inhibition Yes – Adjustable according to test voltage Smoothing function Configurable – Digital filtering stabilizing the measurements Capacitance 0.005 to 49.99 μF leakage current measurement 0.001 nA to 3 mA Memory– Communication Storage of R(t) Viewing on display + Storage of the samples Storage of measurements Up to 1,500 measurement results Direct report printing On locally-connected printer, fixed format Communication port RS-232 PC software DataView ® (option) Display Wide graphical screen Power supply NiMH rechargeable battery Dimensions / weight 270 x 250 x 180 mm / 4.3 kg Electrical safety IEC 61010 1000 V CAT III - 600 V CAT IV IEC 61557
TEXTEDIGITAL INSULATION TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 1000 V CAT IV IP C.A 6550 - C.A 6555 Ref. : P01139705 P01139706 STRENGTHS Q Fixed and programmable test voltages from 40 V to 10/15 kV Q Wide measurement range from 10 kΩ to 30 TΩ Q 5 mA charging current Q Digital graphical display and bargraph of the R(t) + U(t), i(t) and i(u) curves in real time Q Ramp and voltage step tests ADDITIONAL INFO Q Resistance calculation at a reference temperature Q memory capacity: 80,000 measurements Q Optically-isolated USB communication Q 2 levels of diagnostics available : - Go / No go - Qualitative measurement for preventive maintenance Q C.A 6550 and C.A 6555 delivered with a shoulder bag containing: Q 2 safety leads 3 m long equipped with an HV plug at each end (red/blue) Q 1 guarded safety lead 3 m long equipped with an HV plug at one end and an HV plug with rear connection at the other end (black) Q 3 crocodile clips (red, blue, black) Q 2 x CAT IV 1000 V test probes (red/black) for voltage measurement Q 1 blue lead 0.5 m long with rear connection Q 1 mains power cable 2 m long Q DataView® software Q 1 optical / USB communication cable Q 1 CD-Rom containing the user manual ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6550 C.A 6555 Test voltages 10 kV 15 kV Insulation measurement Ranges 500 V : 10 kΩ to 2 TΩ 1,000 V : 10 kΩ to 4 TΩ 2,500 V : 10 kΩ to 10 TΩ 5,000 V : 10 kΩ to 15 TΩ 10,000 V : 10 kΩ to 25 TΩ 15,000 V : 10 kΩ to 30 TΩ Fixed test voltages 500 / 1,000 / 2,500 / 5,000 / 10,000 V 500 / 1,000 / 2,500 / 5,000 / 10,000 / 15,000 V Variable test voltages
40 V - 10,000 V
40 V - 15,000 V
Variable: 40-10 kV Increment:
40 V - 1 kV: 10 V
1 kV - 10 kV: 100 V Variable: 40-15 kV Increment: 1 kV - 15 kV: 100 V Ramp mode 3 preconfigurable ramps: start voltage / end voltage / duration Ramp configuration range 40-1,100 V / 500-10,000 V 40-1,100 V / 500-15,000 V Step mode Up to 10 plateaux (values and duration configurable for each plateau) Voltage measurement before and after test AC : 0 - 2,500 V DC : 0 - 4,000 V Capacitance measurement (> 500 V) 0.001-9.999 μF / 10.00-49.99 μF Leakage current measurement 0 - 8 mA Discharge after test Yes / automatic Additional test stop modes I-limit Programmable 0.2 - 5 mA Early-break di/dt Timer Up to 99:59 minutes Debug mode Burn-in Permanent test Calculation of ratios PI, DAR, DD, SV, ∆R (ppm/V) Calculation of R at ref. temp. Yes Measurement display filter 3 filters with variable time constant Graphs on display R(t)+u(t) ; i(t) ; i(u) Storage 256 recordings, 80,000 cts R, U, I and date-stamp Communication Optically-isolated port for USB and RS232 connection PC software DataView Power supply NiMH rechargeable batteries, 8 x 1.2 V / 4,000 mAh Charging by 90-260 V 50/60 Hz external voltage Electrical safety 1000 V CAT IV - IEC 61010-1 and IEC 61557 Dimensions / weight 406 x 330 x 174 mm, 6 kg approx.
TEXTEMULTIMETER CLAMPS FOR LEAKAGE CURRENT ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Q F62 & F65 delivered with 1 shoulder bag Q 1 set of straight banana/elbowed banana leads Q 1 set of safety test probes Q 2 x 1.5 V LR03 batteries 10 μA 10,000 counts F62 - F65 Ref. : P01120760 P01120761 STRENGTHS Q Quick leakage-current testing Q Troubleshooting of insulation faults on live installations Q 50/60 Hz filter ACCESSORIES / REPLACEMENT PARTS Q Red + black crocodile clips in blister pack (set of 2) _____P01295457Z Q Elbowed test-probe leads, 1.5 m (1 red /1 black) _______ P01295456Z Q See all the accessories on page 102 SPECIFICATIONS F62 F65 Display 10,000 counts - 2 measurements / s Acquisition AVG TRMS Function Unit Calibre Resolution Accuracy with 50-60 Hz filter with 50-60 Hz filter Current mA AC 60 mA 10 μA 1.2 % ± 5 cts 2.5 % ± 5 cts 60 - 500 Hz 1.2 % ± 5 cts 2.5 % ± 5 cts (60-500 Hz) 600 mA 100 μA 3.5 % ± 10 cts (500-3 kHz) A AC
10 A 1 mA
1.2 % ± 5 cts 2.5 % ±5 cts 60 - 500 Hz 1.2 % ± 5 cts 2.5 % ± 5 cts (60-500 Hz)
80 A 10 mA
3.5 % ± 10 cts (500-3 kHz)
100 A 5 % ± 5 cts 5 % ± 5 cts (50-60 Hz) 5 % ± 5 cts 5 % ± 5 cts (50-60 Hz)
Voltage V AC 600 V 0.1 V 1.0 % ± 5 cts (50-60 Hz) 1.2 % ± 5 cts (60-500 Hz) 1.0 % ± 5 cts (50-60 Hz) 1.2 % ± 5 cts (60-500 Hz) 2.5 % ± 5 cts (500-3 kHz) V DC 600 V 0.1 V 1 % ± 2 cts Resistance Ω 1 kΩ 0.1 Ω 1 % + 3 cts (VTest ≤ 3.3 VDC)Audible continuity Buzzer < 35 Ω Frequency A 100 Hz 1 kHz 0.1 Hz 1 Hz 0.5 % ± 2 cts (I > 10 mA) V 100 Hz 1 kHz 0.1 Hz 1 Hz 0.5 % ± 2 cts (V > 5 VAC) Max. value 100 ms Backlighting Yes Deactivatable automatic power-off Yes Clamping diameter 28 mm Dimensions / weight 218 x 64 x 30 mm / 280 g (with batteries) Standards IEC 61010-1 / IEC 61010-2-032 / IEC 61010-2-033 Installation category 300 V CAT III Enclosure protection rating IP 30 as per EN 60529
TEXTECHOOSE YOUR EARTH TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6421 page 80 C.A 6423 page 80 C.A 6460 page 81 C.A 6462 page 81 Type Earth testers Earth 3P method QQQQ 4P method QQ Automatic coupling Selective earth Earth clamp 4P + clamp method 2-clamp method Pylon earth measurement Resistivity Manual QQ Automatic Contact voltage measurement Measurement of potential QQ Continuity Earth potential Measurement frequency Single frequency: 128 Hz QQQQ Single frequency: 2,083 Hz 41 to 512 Hz 41 to 5,078 Hz Measurement of Rs, Rh Measurement of Ustray Display Analogue Q LCD QQQ 3-display LCD OLED Storage / Communication Storage Communication Optical USB interface Bluetooth® Power supply Batteries QQQ Rechargeable batteries Q PC / Tablet software GTT/ DataView® GTC Tablet application
TEXTECHOOSE YOUR EARTH AND RESISTIVITY TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6470N TERCA 3 page 82 C.A 6471 page 83 C.A 6472 page 84 C.A 6416 page 86 C.A 6417 page 86 Type Earth and resistivity testers Earth testers Earth 3P method QQQ 4P method QQQ Automatic coupling QQQ Selective earth Earth clamp QQ 4P + clamp method QQ 2-clamp method QQ Pylon earth measurement* Q Resistivity Manual Automatic QQQ Contact voltage measurement QQ Measurement of potential QQQ Continuity QQQ Earth potential Q Measurement frequency Single frequency: 128 Hz Single frequency: 2,083 Hz QQ 41 to 512 Hz QQ 41 to 5,078 Hz Q Measurement of Rs, Rh QQQ Measurement of Ustray QQQ Display Analogue LCD 3-display LCD QQQ OLED QQ Storage / Communication Storage QQQQQ Communication QQQ Q Optical USB interface QQQ Bluetooth® Q Power supply Batteries QQ Rechargeable batteries QQQ PC / Tablet software GTT/ DataView® QQQ GTC Q Tablet application Q *Used with the C.A 6474
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6421 - C.A 6423 Ref. : P01123011 P01127013 STRENGTHS Q 2-pole and 3-pole methods Q Simple to use Q Confirmation of the measurement by self-diagnosis Q Designed for use in the field with leakproof on-site casing and easy-to-read display Q C.A 6421 and C.A 6423 delivered with transport strap Q 8 x 1.5 V LR06 batteries ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6421 C.A 6423 Measurement Earth Type 2P & 3P Resistivity No Measurement range 0.5 to 1,000 Ω 0.01 to 2,000 Ω (in 3 automatic calibres) Resolution - 10 mΩ / 100 mΩ / 1 Ω (depending on calibre) Accuracy ± (5 % + 0.1 % at full scale) ± (2 % + 1 pt) No-load voltage ≤ 24 V ≤ 48 V Frequency 128 Hz Alarms 3 fault indicator LEDs Power supply 8 x 1.5 V LR06 batteries Display Analogue 2,000-count digital LCD Electrical safety IEC 61010 & IEC 61557 Dimensions / weight 238 x 136 x 150 mm / 1.3 kg IP
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM IP C.A 6460 - C.A 6462 Ref. : P01126501 P01126502 STRENGTHS Q 3-in-1 testers: resistivity, earth and coupling Q Validation of the measurement by self-diagnosis: 3 LEDs indicating the presence of faults liable to make the measurement result invalid Q Highly-resistant site-proof casing with lid for use in severe field conditions Q Large LCD display with backlighting Q C.A 6460 delivered with 8 x 1.5 V LR06 batteries Q C.A 6462 delivered with 1 mains lead for recharging ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6460 C.A 6462 Measurement Earth / resistivity / coupling Type 3P & 4P Measurement range 0.01 to 2,000 Ω (in 3 automatic calibres) Resolution 10 mΩ / 100 mΩ / 1 Ω (depending on calibre) Accuracy ± (2 % + 1 ct) No-load voltage ≤ 42 V peak Frequency 128 Hz Alarms 3 fault indicator LEDs Power supply 8 x 1.5 V LR06 batteries NiMH rechargeable battery Display 2,000-count digital LCD Electrical safety IEC 61010 & CEI 61557 Dimensions 273 x 247 x 127 mm (handle folded away) Weight 2.8 kg 3.3 kg EARTH / RESISTIVITY / COUPLING TESTERS
TEXTEEARTH AND RESISTIVITY TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM IP 50 V CAT IV C.A 6470N TERCA 3 Ref. : P01126506 STRENGTHS Q 4-in-1 tester: Earth / Resistivity / Coupling / Continuity Q Suitable for industry, housing and electricity companies Q C.A 6470N delivered with: Q 1 mains adapter Q 1 x 2-pole mains power cable for battery recharging on the mains Q Data export software Q 1 optical / USB communication cable Q 1 CD-Rom containing the user manual Q 5 specifications labels ACCESSOIRES / RECHANGES Q Adapter for battery-charging on vehicle cigarette-lighter __ P01102036 Q See all the accessories on page 102 SPECIFICATIONS C.A 6470N 3P method Range (automatic selection) 0.01 Ω to 99.9 kΩ Resolution 0.01 to 100 Ω Test voltage 16 or 32 V, selectable Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Accuracy ± 2 % of value ± 1 ct 4P method Range 0.001 Ω to 99.99 kΩ Resolution 0.001 to 10 Ω Test voltage 16 V or 32 V Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Measurement accuracy ± 2 % of value ± 1 ct Soil resistivity measurement - 4P method Measurement method Wenner or Schlumberger method with automatic calculation of the results and display in Ω-metre Range (automatic selection) 0.01 Ω to 99.99 kΩ Resolution 0.01 Ω to 100 Ω Test voltage 16 or 32 V, selectable Measurement frequency 41 to 128 Hz External voltage measurement Range (automatic selection) 0.1 to 65.0 VAC/DC - DC and 15-440 Hz Accuracy ± 2 % of value + 1 ct Resistance / continuity measurement - earth connection test) Measurement type 2P or 4P method, selectable Range (automatic selection) 2P : 0.01 Ω to 99.9 kΩ 4P : 0.001 Ω to 99.99 kΩ Accuracy ± 2 % of value + 3 cts Test voltage 16 VDC (polarity +, − or auto) Test current > 200 mA for R < 20 Ω Storage Memory capacity 512 test results Communication Optically-isolated USB Power supply Rechargeable battery Charger power supply External power supply with 18 VDC / 1.5 A output or 12 VDC vehicle power supply Dimensions / weight 272 x 250 x 128 mm / 3.2 kg Electrical safety 50 V CAT IV EARTH / RESISTIVITY / COUPLING / CONTINUITY TESTER
TEXTEEARTH AND RESISTIVITY TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM EARTH / SELECTIVE EARTH / RESISTIVITY / COUPLING / CONTINUITY TESTER C.A 6471 Ref. : P01126505 STRENGTHS Q 5-in-1 tester: Earth / Selective earth / Resistivity / Coupling / Continuity Q Ideal for industry and electricity companies Q C.A 6471 delivered with: Q 1 mains adapter Q 1 x 2-pole main power cable for battery recharging on the mains Q Data export software Q 1 optical / USB communication cable Q 2 x C182 clamps with 2 safety leads Q 1 carrying bag Q 1 CD-Rom containing the user manual Q 5 specifications labels ACCESSORIES / REPLACEMENT PARTS Q Adapter for battery recharging on vehicle cigarette lighter _ P01102036 Q See all the accessories on page 102 SPECIFICATIONS C.A 6471 Measurements with 2 clamps Range 0.01 to 500 Ω Resolution 0.01 to 1 Ω Measurement frequency Auto : 1,611 Hz Manual : 128 Hz - 1,367 Hz - 1,611 Hz - 1,758 Hz 3P method Range (automatic selection) 0.01 Ω to 99.9 kΩ Resolution 0.01 Ω to 100 Ω Test voltage 16 V or 32 VRMS rated voltage, selectable Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Accuracy ± 2 % of value + 1 ct at 128 Hz 4P method / 4P+clamp measurement Range 0.001 Ω to 99.99 kΩ Resolution 0.001 to 100 Ω Test voltage 16 V or 32 V, selectable Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Measurement accuracy ± 2 % of value ± 1 ct Soil resistivity measurement Measurement method Wenner or Schlumberger method with automatic calculation of the results and display in Ω-metre Range (automatic selection) 0.01 to 99.99 kΩ ; ρ max. 999 kΩm Resolution 0.01 Ω to 100 Ω Test voltage 16 or 32 V, selectable Measurement frequency 41 to 128 Hz, selectable External voltage measurement Range (automatic selection) 0.1 to 65.0 VAC/DC - DC and 15-440 Hz Accuracy ± 2 % of value + 1 ct Resistance / Continuity measurement - (earth connection test) Measurement type 2P or 4P method, selectable Range (automatic selection) 2P: 0.01 Ω to 99.9 kΩ; 4P : 0.001 Ω to 99.99 kΩ Accuracy ± 2 % of value + 2 cts Test voltage 16 VDC (polarity +, − or auto) Test current > 200 mA for R < 20 Ω Storage Memory capacity 512 test results Communication Optically-isolated USB Power supply Rechargeable battery Charger power supply External power supply with 18 VDC / 1.9 A output or 12 VDC Dimensions / weight 272 x 250 x 128 mm / 3.2 kg Electrical safety 50 V CAT IV IP 50 V CAT IV
TEXTEEARTH AND RESISTIVITY TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM IP 50 V CAT IV C.A 6472 Ref. : P01126504 STRENGTHS Q All types of earth resistance measurement & pylon earth measurement (with the C.A 6474) Q Resistivity (Wenner + Schlumberger methods) Q Earth coupling Q Soil potential measurement Q Continuity / resistance Q C.A 6472 delivered with: Q 1 mains adapter Q 1 x 2-pole mains power cable for battery recharging on the mains Q Data export software Q 1 optical / USB communication cable Q 2 x C182 clamps with 2 safety leads Q 1 carrying bag Q 1 CD-Rom containing the user manual Q 5 specifications labels ACCESSORIES / REPLACEMENT PARTS Q Adapter for battery charging on vehicle cigarette lighter __ P01102036 Q See all the accessories on page 102 SPECIFICATIONS C.A 6472 3P measurements Range (automatic selection) 0.01 Ω to 99.9 kΩ Resolution 0.01 Ω to 100 Ω Test voltage 16 V or 32 VRMS rated voltage, selectable Measurement frequency 41 to 5.078 Hz, automatic or manual Test current Up to 250 mA Accuracy ± 2 % R +1 ct at 128 Hz Measurements with 2 clamps Range 0.01 to 500 Ω Resolution 0.01 to 1 Ω Measurement frequency Auto: 1,611 Hz - Manual: 128 Hz - 1,367 Hz - 1,611 Hz - 1,758 Hz 4P method / 4P+clamp measurement Range 0.001 Ω to 99.99 kΩ Resolution 0.001 to 10 Ω Test voltage 16 V or 32 V, selectable Measurement frequency 41 to 5,078 Hz, automatic or manual Test current Up to 250 mA Measurement accuracy ± 2 % of value ± 1 ct Soil resistivity measurement - 4P method Measurement method Wenner or Schlumberger method with automatic calculation of the results and display in Ω-metre Range (automatic selection) 0.01 to 99.99 kΩ ; ρ max. 999 kΩm Resolution 0.01 Ω to 100 Ω Test voltage 16 or 32 V, selectable Measurement frequency 41 to 512 Hz, selectable Earth potential measurement Measurement range 0.00 to 65.00 V Resolution 0.01mV to 10 mV Measurement frequency 41 to 5,078 Hz Accuracy ± 5% + 1 ct at 128 Hz External voltage measurement Range (automatic selection) 0.1 to 65.0 VAC/DC - DC and 15-450 Hz Accuracy ± 2 % of value + 1 ct Resistance / Continuity measurement Measurement type 2P or 4P method, selectable Range (automatic selection) 2P : 0.01 Ω to 99.9 kΩ 4P : 0.001 Ω to 99.99 kΩ Accuracy ± 2 % of value + 2 cts Test voltage 16 VDC (polarity +, − or auto) Test current > 200 mA for R < 20 Ω Storage Memory capacity 512 test results Communication Optically-isolated USB Power supply Rechargeable battery Charger power supply External power supply with 18 VDC / 1.9 A output or 12 VDC vehicle power supply Dimensions / weight 272 x 250 x 128 mm / 3.2 kg Electrical safety 50 V CAT IV EARTH / SELECTIVE EARTH / RESISTIVITY / COUPLING / CONTINUITY / PYLON EARTH TESTER
TEXTEEARTH AND RESISTIVITY TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM IP SPECIALLY FOR MEASUREMENTS ON PYLONS C.A 6474 Ref. : P01126511 STRENGTHS Q Used with the C.A 6472 for measurements on pylons Q Overall line impedance Q Pylon earth resistance Q Resistance of each pylon footing Q Quality of overhead earth wire connection Q C.A 6474 delivered with an accessories bag containing: Q 1 connection cable Q 6 BNC/BNC cables 15 m long Q 4 AmpFlex® flexible current sensors 5 m long Q 1 set of 12 identification rings for AmpFlex® Q 2 cables (5 m green, 5 m black) with safety plugs on winder Q 5 spade lug/Ø 4 mm banana plug adapters Q 3 adjustable clamps Q 1 calibration loop Q 5 specifications labels Available with 8 m AmpFlex® sensor ADDITIONAL INFO Possibility of connecting several AmpFlex® sensors in series for a length > 8 metres The complete Pylon Earth Kit is available to order with the code P01299930. It comprises: Q C.A 6472 Q C.A 6474 Q 5 m AmpFlex® Q 100 m earth kit For the 8 m AmpFlex® version of the complete pylon earth kit, order: ACCESSORIES / REPLACEMENT PARTS Q Connection cable between the C.A 6472 and C.A 6474 ____ P01295271 Q See all the accessories on page 102 SPECIFICATIONS C.A 6474 / PYLON BOX Measurements Measurement type Overall pylon earth resistance Earth resistance of each pylon footing Overall line impedance Quality of overhead earth wire connection. Active measurement (injection by the C.A 6472) Passive measurement (use of eddy currents) Range 0.067 Ω to 99.99 kΩ Accuracy ± (5 % + 1 ct) Frequency 41 to 5,078 Hz Frequency sweep Yes Dimensions 272 x 250 x 128 mm Weight 2.3 kg Power supply / Storage / Display Provided by the C.A 6472
TEXTEEARTH AND RESISTIVITY TESTERS ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM Q 1 clamp delivered in a shoulder bag Q 4 x 1.5 V LR06 batteries Q 1 verification certificate Q 1 CD-ROM containing the user manual Q The C.A 6417 is delivered with the simplified GTC driver as well C.A 6416 - C.A 6417 Ref. : P01122015 P01122016 STRENGTHS Q Quick earth-loop testing Q OLED screen and force compensation system Q Simultaneous display of Ω and A Q Contact voltage alarm ADDITIONAL INFO Q Automatic measurement HOLD when the clamp is opened Q Android application downloadable from Google Play ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 102 SPECIFICATIONS C.A 6416 C.A 6417 Loop ohmmeter 1,500-count display Measurement ranges (Ω) / Resolution (Ω) / Accuracy 0.10 to 0.99 / 0.01 / ±1.5 % ±2 r (r = resolution) 100 to 199 / 1 / ±3 % ±r 200 to 395 / 5 / ±5 % ±r 400 to 590 / 10 / ±10 % ±r 600 to 1,150 / 50 / Approx. 20 % 1,200 to 1,500 / 50 / Approx. 25 % Frequencies Measurement frequency: 2,083 Hz Translation frequency: 50, 60, 128 or 2,083 Hz Loop inductance measurement Measurement ranges (μH) / Resolution (μH) / Accuracy 10 to 100 / 1 / ±5 %±r 100 to 500 / 1 / ±3 %±r Contact voltage (calculated) Measurement ranges (V) / Resolution (V) / Accuracy Ammeter 4,000-count display Measurement ranges (A) / Resolution (A) / Accuracy 0.200 to 0.999 mA / 1 μA / ±2 % ±50 μA 1.000 to 2.990 mA - 3.00 to 9.99 mA / 10 μA / ±2 % ±50 μA 10.00 to 29.90 mA - 30.0 to 99.9 mA / 100 μA / ±2 %±r 100.0 to 299.0 mA - 0.300 to 0.990 A / 1 mA / ±2 %±r 1.000 to 2.990 A - 3.00 to 39.99 A / 10 mA / ±2 %±r Setup Modes Standard or advanced Alarms Configurable on Z, V and A Buzzer Active / Inactive HOLD Manual or automatic PRE-HOLD Automatic power-off Active / Inactive General specifications Display 152-segment OLED. Active area: 48 x 39 mm Max. clamping diam. Ø 35 mm Storage 300 time/date-stamped measurements 2,000 time/date-stamped measurements Communication Bluetooth® Class 2 Power supply 4 x 1.5 V LR06 alkaline batteries or 4 x Ni-MH rechargeable batteries Battery life 1,440 x 30-second measurements Calibration Automatic at startup Electrical safety IEC 61010 600 V CAT IV Ingress protection IP40 Dimension / weight 55 x 95 x 262 mm / Approx. 935 g with batteries 600 V CAT IV IP
TEXTECHOOSE YOUR ELECTRICAL EQUIPMENT TESTER ELECTRICAL SAFETY 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM C.A 6121 page 88 C.A 6155 page 89 Insulation
250 VDC Q
500 VDC QQ
1,000 VDC Q Dielectric tests 1,000 / 1,250 / 1,500 VAC Q 1,000 / 1,890 / 2,500 VAC Q 100 to 5,000 VAC Continuity I test > 10 A QQ I test 0.2 A Q I test 0.1 A I test 25 A Voltage drop I test 10 A Q Via Zi Q Discharge time Discharge time at 60 V QQ Leakage current Via socket Q Substitution method (residual) Q Contact leakage current Q Direct method via clamp Q Functional testing Apparent power S, voltage V Q Active power, current, frequency & cos φ Loop impedance & loop resistance Zs-loop (L-PE) (Trip), Calculation of Ik (PFC) Q Zs-loop (L-PE) (No Trip), Calculation of Ik (PFC) Q Zi-loop (L-N or LL), Calculation of Isc (PSCC) Q RCD & PRCD testing PRCD x 0.5 / x 1 / x 5x I∆n Q RCD x 0.5 / x 1 / x 2 / x 5x I∆n Q Other functions Alarms QQ Phase sequence Q Storage / communication Storage Q(999) Q(6000) RS232 / USB communication QQ Q Transmission of results to printer QQ Interface for pedal (START/STOP, SAVE) and lamps Q Interface for barcode Q DOOR OPEN interface PC software MachineLink CALink
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY ELECTRICAL EQUIPMENT TESTERS C.A 6121 Ref. : P01145601 STRENGTHS Q Insulation Q Dielectric test Q Continuity Q Voltage drop Q Discharge time Q C.A 6121 Q 1 accessories bag Q 2 dielectric test guns with 2 m cable Q 2 continuity test leads 2.5 m long (1 red, 1 black) Q 2 insulation test leads 3 m long (1 red, 1 black) Q 2 crocodile clips (1 red, 1 black) Q 1 red test probe Q 1 discharge-time cable Q 1 power supply cable ACCESSORIES / REPLACEMENT PARTS Q Machine Link Windows processing software Q See all the accessories on page 102 SPECIFICATIONS C.A 6121 Insulation Test voltage 500 / 1,000 VDC Measurement range 1 kΩ to 500 MΩ Accuracy 0 to 200 MΩ ± (2 % R + 2 cts) Dielectric tests Test voltage 1,000 / 1,250 / 1,500 VAC (50 Hz) for Umains =
230 V and at 500 VA
Measurement range 0 to 500 mA Accuracy ± (2 % R + 0.3 mA) For trigger current set to 1, 3, 5, 10 or 20 mA ± (2 % R + 0.5 mA) For trigger current set to 30, 40, 50, 60, 70, 80, 90 or 100 mA ± (2 % R + 2 mA) For trigger current set to 150, 200, 250, 300, 330, 350, 400, 450 or 500 mA Continuity Range 0 to 2 Ω Measurement current I > 10 A Accuracy 0 to 1 Ω ± (2 % R + 2 mΩ) Voltage drop Test current 10 A Measurement range 0 to 10 V Accuracy ± (2 % R + 0.02 V) Discharge time External (2 cts) or internal (4 cts) Range 0 - 10 s Accuracy ± (2 % R + 0.2 s) Storage 999 measurements Communication output RS232 Power supply 230 V / 50 Hz mains supply Dimensions / weight 400 x 260 x 250 mm / 11 kg Electrical safety IEC 61010-1 - 600 V CAT III 600 V CAT III IP
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY ELECTRICAL EQUIPMENT TESTERS 300 V CAT III IP SPECIFICATIONS C.A 6155 Ref. : P01146002 STRENGTHS Q Integration of all the measurements required by the new editions of the IEC 60204 (edition5), VDE0701/0702 and IEC 61439 (ex-IEC 60439) standards Q Preprogrammed test sequences based on the standards or customizable Q Extended memory, up to 6,000 measurements stored ADDITIONAL INFO Q Large backlit graphical display with an intuitive user interface Q Contextual help for each function Q Built-in keypad for quick, simple customization of the measurements recorded Q Possibility of connecting a barcode reader Q C.A 6155 Q 1 accessories bag containing: Q 2 high-voltage test cables (2 m) Q 1 high-voltage test probe (red) Q 1 high-voltage crocodile clip (red) Q 1 plug-in test cable 1.5 m long Q 1 test cable 3 m long with three separate leads Q 3 test cables (green, black, red, 1.5 m) Q 1 test cable (red, 4 m) Q 4 test probes (blue, green, black, red) Q 3 crocodile clips (black) Q PC software on CD-ROM with RS232 cable and USB Q 1 multilingual safety datasheet Q 1 measurement report C.A 6155 Dielectric test Test voltage 1,000 V / 1,890 V / 2,200 V I limit 0.1 to 100 mA (1,890 V / 2,200 V) 0.1 to 200 mA (1,000 V) Timer 2, 3, 5, 10, 30 s Insulation resistance measurement U test 250 / 500 VDC Range up to 200 MΩ Timer 5, 10, 30, 60, 120 s Continuity test Range 0.01 to 1.99 Ω - 2.00 Ω to 19.9 Ω I test 0.20 / 10 A U test < 9 V Timer 5, 10, 30, 60, 120, 180 s Leakage current measurement Substitution method 0.00 to 19.99 mA Differential method 0.00 to 9.99 mA Accuracy ± (5 % R + 5 cts) Contact leakage current measurement Measurement range 0.00 to 2.50 mA Accuracy ± (10 % R + 5 cts) Measurement of 60 V / 120 V discharge time 10 % R Voltage range (peak value) 0 to 550 V Time range 0 to 9.9 s Functional testing Apparent power 0.00 to 4.00 kVA Power-cable polarity test Yes Current measurement with clamp 0.00 mA to 24.9 A PRCD test Calibre 10, 15, 30 mA Test current 0,5 x I∆n, I∆n, 5 x I∆n Other Automatic PRCD test RCD test Calibre 10, 30, 100, 300, 500, 1,000 mA Test current 0.5 x I∆n, I∆n, 2 x I∆n, 5 x I∆n Current range AC / AC (pulsed) / DC Type of RCD General / Selective Type of test Ramp / Pulse Uc contact voltage measurement Yes Other Automatic RCD test High-current Zs loop measurement Measurement current 6.5 A Range 0.00 to 1,999 Ω Accuracy ±(5 % R + 5 digits) Calculation of Ik 0.00 to 23.0 kA Zs loop measurement (no RCD trip) Range 0.00 to 1,999 Ω Accuracy ±(5 % R + 10 digits) Calculation of Ik 0.00 to 23.0 kA Zi loop measurement Measurement current 6.5 A Range 0.00 to 1,999 Ω Accuracy ±(5 % R + 5 digits) Calculation of Ik 0.00 to 199 kA Voltage / frequency 0 to 550 V / DC, 14.0 to 499.9 Hz Phase rotation Voltage 100 to 550 V AC Frequency 14 to 500 Hz Communication RS 232 1 barcode/ RFID reader connection + 1 printer / PC connection USB 1 printer / PC connection Alarms Yes for all functions Storage 6,000 memory locations Software Yes, delivered as standard, Pro version available as an option Power supply 115 V - 230 V / 50-60 Hz Dimensions / weight 33.5 cm × 16.0 cm × 33.5 cm / 8.4 kg Functional standards VDE 701 702 / IEC 60204 / IEC 61439 Electrical safety IEC 61010-1 / IEC 61557 (parts 1, 2, 3, 4, 6, 7) 300 V CAT II, 300 V CAT III (TP1) Ingress protection IP 50: closed product
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY ELECTRICAL EQUIPMENT TESTERS *BSG = Both Sides Grounded MICRO-OHMMETERS C.A 6240 page 93 C.A 6255 page 94 C.A 6292 page 95 4-wire measurement method (Kelvin) QQQ Measurement range 400 Ω 2,500 Ω 1 Ω Resolution 1 μΩ 0.1 μΩ 0.1 μΩ Measurement current 10 A / 1 A / 100 mA / 10 mA 10 A / 1 A / 100 mA / 10 mA / 1 mA Automatic 50 / 100 / 150 and 200 A Manual from 20 to 200 A Inductive mode Normal Inductive, non-inductive, auto non-inductiveNormal / BSG* = Both Sides Grounded Alarms Q Temperature compensation Q USB / RS232 communication QQ Q Memory (number of measurements) 100 1500 8000 Automatic recording QQ Power supply NiMH batteries NiMH batteries Mains
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY CHOOSE YOUR TESTER DTR 8510 page 96 Range of VT/PT ratios 0.8000 to 8,000 / 1 Range of CT ratios 0.8000 to 1,000 / 1 Power supply up to 10 hours Memory 10,000 tests Communication Optical USB RATIOMETERS C.A 6608 page 97 C.A 6609 page 97 Operating mode With connection Avec et sans connexion Operating voltage with connection 40 to 850 VAC between phases 40 to 600 VAC between phases Operating voltage without connection 120 to 400 VAC between phases Power supply Via the measurement 9 V battery PHASE ROTATION AND/OR MOTOR TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY CHOOSE YOUR TESTER C.A 6681 E/R page 98 Operation with/without voltage QQ Location of a short-circuit / circuit break QQ Location of cables, conductors or metal pipes Q CABLE AND METAL CONDUCTOR LOCATOR C.A 6630 page 99 Min / max measurement range 40 mΩ / 40 Ω Min / max resolution 10 μΩ / 10 mΩ Measurement frequency 1 kHz Comparison function 99 sets of settings Manual storage (number of locations) 999 Automatic storage (number of locations ) 9,600 BATTERY CAPACITY TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY MICRO-OHMMETERS 50 V CAT III IP C.A 6240 Ref. : P01143200 STRENGTHS Q 4-wire measurement method Q Automatic current reversal Q Test current up to 10 A Q 1 μΩ resolution Q Automatic recording “on the fly” or manual recording Q C.A 6240 Q 1 shoulder bag Q 1 set of 2 x 10 A Kelvin clamps with 3 m cable Q 1 European 2P mains power cable Q Data export software Q 1 optical / USB communication cable ADDITIONAL INFO Q The C.A 6240 is compatible with the DataView® software ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 106 SPECIFICATIONS C.A 6240 Measurement method 4-wire method Range 4,000 μΩ 40 mΩ 400 mΩ 4,000 mΩ 40 Ω 400 Ω Accuracy 0.25 % ±2 cts 0.25 % ±2 cts 0.25 % ±2 cts 0.25 % ±2 cts 0.25 % ±2 cts 0.25 % ±2 cts Resolution 1 μΩ 10 μΩ 0.1 mΩ 1 mΩ 10 mΩ 100 mΩ Measurement current 10 A 1 A 1 A 100 mA 10 mA 10 mA Memory 100 measurements Communication output Optical / USB link Power supply Rechargeable NiMH battery Dimensions / weight 273 x 247 x 280 mm / 5 kg Electrical safety IEC 61010 - 50 V CAT III
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY MICRO-OHMMETERS 50 V CAT III IP C.A 6255 Ref. : P01143221 STRENGTHS Q Optimized measurement on inductive objects Q 4-wire measurement method Q Automatic compensation of stray currents Q Test current of up to 10 A Q Measurements up to 2,500 Ω, resolution 0.1 μΩ Q Integrated «temperature compensation» function Q C.A 6255 Q 1 set of cables 3 m long terminated by Kelvin clamps Q 1 Euro mains power cable 2 m long Q 1 CD-ROM containing the MOT (Micro-Ohmmeter Transfer) software Q 1 RS 232 communication cable Q 1 CD-ROM containing the user’s manual in 9 languages ADDITIONAL INFO Q The C.A 6255 is compatible with the DataView® software Q Possibility of connecting the Pt100 sensor (option) directly to the instrument ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 106 SPECIFICATIONS C.A 6255 Measurement method 4-wire method Range 5,000 mΩ 25,000 mΩ 250,00 mΩ 2500,0 mΩ 25,000 Ω 250,00 Ω 2500,0 Ω Accuracy 0.05 % +1 μΩ 0.05 % +3 μΩ 0.05 % +30 μΩ 0.05 % +0.3 mΩ 0.05 % +3 mΩ 0.05 % +30 mΩ 0.05 % +300 mΩ Resolution 0.1 μΩ 1 μΩ 10 μΩ 0.1 mΩ 1 mΩ 10 mΩ 100 mΩ Measurement current 10 A 10 A 10 A 1 A 100 mA 10 mA 1 mA Measurement modes Inductive, non-inductive, non-inductive with automatic trigger Temperature compensation By temperature sensor or manual Memory 1500 measurements Communication output RS232 link Power supply Rechargeable NiMH battery Dimensions 270 x 250 x 180 mm / 4 kg Electrical safety IEC 61010 - CAT III 50 V
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY MICRO-OHMMETERS IP BSG C.A 6292 Ref. : P01143300 STRENGTHS Q Permanent test at 100 A and for up to 120 s at 200 A Q Test current up to 200 A Q Resistance from 0.1 μΩ to 1 Ω Q Safe measurements: BSG method (Both Sides Grounded) Q Storage of up to 8,000 measurement results Q C.A 6292 delivered with a hard case containing: Q 1 set of 2 Kelvin leads 6 m long (red / black) with adjustable-clamp connections Q 1 green earth lead 3m long with 1 crocodile clip Q 1 USB cable 1.5 m long Q 1 T1 5 A 250 V fuse mounted in the instrument Q 1 European mains power lead Q 1 CD-ROM containing the DataView® software Q 1 CD-ROM containing the user manual in 5 languages ADDITIONAL INFO Q The backlit LCD screen with its 4 lines of 20 characters is easy to read whatever the environment. ACCESSORIES / REPLACEMENT PARTS Q 1 set of 2 Kelvin leads 6 m long (red / black) Q See all the accessories on page 106 SPECIFICATIONS C.A 6292 Test current Programmable from 20 to 200 A Resistance 0.1 μΩ to 2 mΩ 2 to 200 mΩ 200 mΩ to 1 Ω Resolution 0.1 μΩ (200 A max) 10 μΩ (25 A max to 200 mΩ) 1 mΩ ( 5 A max to 1 Ω) Accuracy ± 1% from 50 μΩ to 1Ω Output voltage 110 VAC : 4.2 V @ 200 A 220 VAC : 8.6 V @ 200 A Maximum load resistance
110 VAC : 20 mΩ @ 200 A
220 VAC : 42 mΩ @ 200 A
Measurement method 4 Kelvin-type connection terminals Test mode Normal or BSG Test duration Adjustable from 5 to 120 s @200 A, unlimited below 100 A Storage Up to 8,000 measurement results Interface USB 2.0 Software DataView® Power supply 100 to 240 VAC - 50/60 Hz Dimensions 502 x 394 x 190 mm Weight 13 kg approx. Operating temperature 0 °C to +55 °C Storage temperature -10 °C to +70 °C Humidity 95% RH Protection Protected against voltage surges, short-circuits, overheating and overvoltage on the safety terminals Ingress protection IP54 Electrical safety IEC 61010-1 Consumption 1,500 VA max. Current measurement with the optional MR6292 clamp Measurement range 1.0 - 50.0 ADC Resolution 0.1 mA Intrinsic uncertainty ± (1.5% + 2 cts) Output signal 10 mV / ADC Load impedance > 100 kΩ // 100 pF Influence of conductor position in jaws 0.50 %
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY RATIOMETER 50 V CAT IV IP DTR 8510 Ref. : P01157702 STRENGTHS Q Measurement of the transformation ratio of power, voltage and current transformers Q Storage of up to 10,000 measurement results Q Displays the transformation ratio, the excitation current, the winding polarity and the percentage deviation from the rated values Q Direct reading of the transformation ratio from 0.8000:1 and up to 8000.0:1 Q Tests performed by excitation of the primary with measurement on the secondary Q 1 set of leads 4.6 m long with crocodile clips Q 1 external battery charger with mains lead Q 1 USB cable Q 1 NiMH battery datasheet Q DataView software on CD-Rom ADDITIONAL INFO Q Up to 10 hours’ continuous operation thanks to the rechargeable NiMH batteries ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 106 SPECIFICATIONS DTR 8510 Range of ratios (VT/PT) Automatic: 0.8000 to 8000:1 Accuracy (VT/PT) Range of ratios Accuracy (% of reading) 0.8000 to 9.9999 ± 0.2 % 10.000 to 999.99 ± 0.1 % 1000.0 to 4999.9 ± 0.2 % 5000.0 to 8000.0 ± 0.25 % Range of ratios (CT) Autoranging: 0.8000 to 1000.0 Accuracy (CT) ± 0.5 % of reading Excitation signal VT/PT mode: 32 Vrms max CT mode: auto-level 0 to 1 A, 0.1 to 4.5 Vrms Display of excitation current Range: 0 to 1,000 mA; Accuracy: ± (2 % of reading + 2 mA) Excitation frequency 70 Hz Display Alphanumeric LCD, 2 lines of 16 characters with adjustment of the contrast and backlighting. Easy to read in both day and night conditions Languages available French, English, Spanish, Italian, German, Portuguese Measurement method As per IEEE Std C57.12.90™ Power supply Two 12 V rechargeable NiMH batteries, 1,650 mAH Battery life Up to 10 hours in continuous operation; low-battery alert Battery charger Universal input (90 to 264 Vrms), smart charger Charging time < 4 hours for full charge Memory 10,000 tests Date / time Powered by dedicated battery, real-time clock Communication USB 2.0, optical isolation, 115.2 kB Software Delivered with the DataView ® analysis software Dimensions / weight 272 x 248 x 130 mm / 3.7 kg Connection XLR connectors Cables Shielded H and X cables 4.6 m (15 ft) long, equipped with colour-coded crocodile clips Casing Rugged polypropylene casing, UL 90 V0 Vibrations IEC 68-2-6 (1.5 mm at 55 Hz) Shocks IEC 68-2-27 (30 G) Falls IEC 68-2-32 (1 m) Ingress protection IP 40 with lid open as per EN 60529 IP 53 with lid closed as per EN 60529 Safety EN 61010-1, 50 V CAT IV; pollution degree 2
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY PHASE ROTATION AND/OR MOTOR TESTERS 600 V CAT III IP C.A 6608, C.A 6609 Ref. : P01191304 P01191305 STRENGTHS Q Indication of phase presence or absence Q Determination of a motor’s rotation direction with or without contact (C.A 6609 only) Q Automatic tests as soon as the connections have been set up Q Terminals and cables identified by colour coding to simplify connection Q C.A 6608 phase rotation testers delivered in a shoulder bag with: Q 3 test leads Q 3 crocodile clips Q C.A 6609 phase rotation and motor tester delivered in a shoulder bag with: Q 3 test leads Q 3 crocodile clips SPECIFICATIONS C.A 6608 C.A 6609 Operating voltage for phase rotation function 40 to 850 VAC between phases With connection: 40 to 600 VAC between phases Without connection: 120 to
400 VAC between phases
Frequency range 15 to 400 Hz Power supply Self-powered via measurement inputs 9 V battery Dimensions 130 x 69 x 32 mm Weight 130 g 170 g Electrical safety IEC 61010-1 600 V CAT III IEC 61557-7
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY CABLE AND METAL CONDUCTOR LOCATOR C.A 6681 Ref. : P01141626 STRENGTHS Q Can be used on live or non-current-carrying installations Q Digital, visual and audible indication to track the conductor intuitively Q Large LCD screen with indication of the transmission power, the digital identification code and the voltage present on the circuit tested. CONTENU Q 1 hard case containing 1 C.A 6681E transmitter Q 1 C.A 6681R receiver Q 1 set of 2 red/black leads, straight male isolated Ø 4 mm banana / elbowed make isolated Ø 4 mm banana, 1.5 m long Q 1 set of 2 red/black crocodile clips Q 1 earthing stake Q 1 adapter for mains power socket Q 1 male plug adapter for B22 bayonet socket Q 1 male plug adapter for E27 screw socket Q 1 x 9 V 6LR61 battery Q 6 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Q 33 m reel of green wire with battery clip/4 mm Q 15 m reel of green wire with battery clip/4 mm Q See all the accessories on page 102 SPECIFICATIONS C.A 6681 R Detection depth Single-pole application: 0 to 2 m approx. Two-pole application: 0 to 0.5 m approx. Simple looping line: up to 2.5 m Identification of network voltage 0~0.4 m approx. Dimensions 241.5 × 78 × 38.5 mm Weight 360 g approx. with battery C.A 6681 E Transmitted signal frequency 125 kHz External voltage measurement 12~300 V DC/AC(50~60 Hz) Dimensions 190 × 89 × 42.5 mm Weight 420 g approx. with battery ADDITIONAL INFO Q Automatic or manual adjustment of signal reception sensitivity Q The transmitter and receiver units are equipped with: - A battery status indicator - An additional lighting system (torch) for use in dark environments
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM ELECTRICAL SAFETY BATTERY CAPACITY TESTERS C.A 6630 Ref. : P01191303 STRENGTHS Q Zero adjustment function for compensation of the voltage circuit displayed Q 2-display LCD screen Q 7-hour battery life in continuous operation with 6 x 1.5 V batteries (not supplied) Q Capacity test from 35 Ah to 500 Ah Q Nickel-Cadmium, Lithium-Ion, Nickel-Metal-Hybrid or Lead-Acid batteries Q 1 hard case containing: Q C.A 6630 Q 1 set of 2 measurement leads 1 m long terminated by retractable test probes Q PC data transfer software to export and process the stored data Q 1 C.A 6630 / PC connection cable ACCESSORIES / REPLACEMENT PARTS Q Set of 2 leads with retractable test probes ____________ P01102103 Q See all the accessories on page 102 SPECIFICATIONS C.A 6630 Resistance measurement Range 40 mΩ 400 mΩ 4 Ω 40 Ω Resolution 10 μΩ 100 μΩ 1 mΩ 10 mΩ Measurement current 37.5 mA 3.75 mA 375 μA 37.5 μA Accuracy ± (1 % R + 8 digits) Temp. coeff.: ± ( 0.1 % R + 0.5 digit) / °C Measurement voltage 1.5 mVAC Measurement frequency 1 kHz ± 10 % Voltage measurement Range 4 V 40 V Resolution 1 mV 10 mV Accuracy ± (0.1 % R + 6 digits) Max. consumed power 1 VA Mechanical specifications Dimensions 250 x 100 x 45 mm Weight 500 g including batteries BATTERY CAPACITY TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 100 ELECTRICAL SAFETY DATA PROCESSING SOFTWARE DATAVIEW® Réf. : P01102095 FUNCTIONS Q Configuration of all the functions of instruments connected to a PC or via Bluetooth® Q Recovery of the recorded measurement data Q Backup of measurement files Q Opening of saved files Q Processing and creation of reports Q Export into an Excel spreadsheet Q Export in .pdf format Q Database management Q Remote test activation by simply pressing a button Q Data capture and display in real time Q Display of DAR, PI and DD ratios Q Graphical plotting of programmed-duration tests and voltage ramp tests in real time Q Possibility of creating a library of configurations for specific applications Q Printing of measurement reports Q Windows XP / 256MB of RAM Q Windows Vista & Windows 7/8/10 (32/64 bit) Q 1 GB of RAM for Windows Vista & Windows 7/8 (32 bit) Q 2 GB of RAM for Windows Vista & Windows 7/8 (64 bit) Q 80 MB available space on hard disk (200 MB recommended) REQUIRED CONFIGURATION ADDITIONAL INFO Q The DataView® software: Q Automatically recognizes the instrument connected when it is hooked up to the PC and opens the corresponding menu. Users then have direct access to the configuration and the recorded data Q Is equipped with a large number of predefined report templates for quick generation in compliance with the applicable standards. Users can also create their own templates, as required, and directly add their own comments. DataView® Modules ICT MEG GTT GTC MOT DTR Associated products C.A 6117 C.A 6547 C.A 6471 C.A 6255 C.A 6549 C.A 6472 C.A 6292 C.A 6550 C.A 6474 C.A 6555 C.A 6526 C.A 6532 C.A 6534 ICT MEG GTT GTC MOT DTR ICT REPORTS ACCORDING TO THE APPLICABLE STANDARDS The ICT module of DataView® proposes to define the tree-structure which will be used during the actual test campaign (sites, parts, objects), as well as the tests to be performed for each of them. Once defined in this way, the campaign can be recorded in the instrument via the communication link. This saves significant time in the field.
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 101 ELECTRICAL SAFETY DATA PROCESSING SOFTWARE MEG MODULE Graphical plotting of the V(t) and R(t) tests on a fixed insulation resistanceMEG MODULE Graphical plotting of the V(t) and R(t) tests on a non-linear insulation resistance (surge suppressor) GTT MODULE Example of configuration MOT MODULE Results of motor winding test DTR MODULE Recovery of the measurement data recorded in the ratiometer
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 102 ELECTRICAL SAFETY ACCESSORIES FOR MULTI-FUNCTION INSTALLATION TESTERS ARTICLE CODE DESCRIPTION C.A 6113 C.A 6116N C.A 6117 P01295398 2.5 m three-point lead with separate wires QQQ P01295393 Three-point lead for EURO mains socket test QQQ P01295094 2 elbowed-straight safety leads - (red and black) 3 m long QQQ P01101921 3 test probes Ø 4 mm - (red, blue and green) QQQ P01101922 3 crocodile clips (red, blue and green) QQQ P01102092A Remote-control probe for C.A 6116N QQQ P01101943 Replacement black test probe for remote-control probe QQQ P01120335 C177 clamp (20 A) Q P01120336 C177A clamp (200A) QQQ P01120460 MN77 clamp (20A) QQQ P01102057 PA 30 W power pack Q P01102129 Type-2 power pack / charger without mains lead (requires P01295174) QQ P01296024 NiMH 35 Wh battery pack Q P01296047 Li-Ion battery pack QQ P01102130 Li-Ion charger support without mains lead QQ P01295174 2P EURO mains lead QQQ HX0061 DC/DC charger for vehicle cigarette lighter Q P01102084A Continuity rod QQQ P01102017 15 m earth kit (red / blue / green) QQQ P01102018 Black 30 m 1P earth kit QQQ P01102021 3P earth kit (50 m) QQQ P01102022 3P earth kit (100 m) QQQ P01298081 4-point hands-free strap - model 2 QQQ P01298057 Hand strap QQQ P01102094 C.A 61 screen protection film QQQ P01298056 Shoulder bag no. 22 QQQ P01295293 USB-A USB-B cable Q QQ P01102095 DataView ® software QQ P01298082 Comfort strap QQQ POWER SUPPLY / BATTERIESMISCELLANEOUS MEASUREMENT LEADS AND SENSORS Q Accessories Q Included in the original delivery
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 103 ELECTRICAL SAFETY MEASUREMENT LEADS FOR INSULATION TESTERS CODE P01295231 Red simplified HV safety lead / black with rear connection 3 m Q QQQ P01295232 Blue simplified HV safety lead + blue crocodile clip 3 m Q QQQ P01295221 Guarded blue simplified HV safety lead with rear connection 0.35 m QQQQ P01295220 Set of 3 safety leads with HV crocodile clips - red, blue and black 3 m Q QQQ P01295214 Safety lead with blue HV crocodile clip 8 m QQQQ P01295215 Safety lead with red HV crocodile clip 8 m QQQQ P01295216 Safety lead with rear connection and black HV crocodile clip 8 m QQQQ P01295217 Safety lead with blue HV crocodile clip 15 m QQQQ P01295218 Safety lead with red HV crocodile clip 15 m QQQQ P01295219 Safety lead with rear connection and black HV crocodile clip 15 m QQQQ P01295465 Set of 3 red, blue and black simplified HV safety leads with rear connection 3 m QQ P01295466 Set of 3 safety leads with red, blue and black HV crocodile clips with rear connection 3 m QQ P01295467 Guarded blue HV safety lead with rear connection 0.5 m QQ P01295468 Safety lead with blue HV crocodile clip 8 m QQ P01295469 Safety lead with red HV crocodile clip 8 m QQ P01295470 Safety lead with rear connection and black HV crocodile clip 8 m QQ P01295471 Safety lead with blue HV crocodile clip 15 m QQ P01295472 Safety lead with red HV crocodile clip 15 m QQ P01295473 Safety lead with rear connection and black HV crocodile clip 15 m QQ P01295471A Safety lead with blue HV crocodile clip 20 m QQ P01295472A Safety lead with red HV crocodile clip 20 m QQ P01295473A Safety lead with rear connection and black HV crocodile clip 20 m QQ 10/15 KV RANGE 5 KV RANGE Q Accessories Q Included in the original delivery
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 104 ELECTRICAL SAFETY CONTENTS OF THE EARTH & RESISTIVITY KITS OTHER ACCESSORIES To order Contents of the earth and resistivity kits Recommended associated products Reels and winders Other accessories Installation testers 3P 3/4P+ρ Expert Pylon Article code Description Green Red Blue Black Stake(s) / Mallet Spade-lug / banana adapter Bag C.A 6030 C.A 6113 C.A 6116N C.A 6117 C.A 6421 C.A 6423 C.A 6460 P01102018 Black 30 m 1P earth kit 33 m 1 / - QQ P01102020 33 m 1P loop kit 33 m 1 / - Q P01102017 15 m 3P earth kit (red, green, blue) 5 m 15 m 10 m 2 / - QQ P01102021 50 m 3P earth kit 10 m 50 m 50 m 2 / 1 5 Standard QQQQ P01102022 100 m 3P earth kit 10 m 100 m 100 m 2 / 1 5 Standard QQQQQ P01102023 166 m 3P earth kit 10 m 166 m 166 m 2 / 1 5 Prestige QQQQ P01102040 50 m 4P resistivity kit 33 m 50 m 50 m 33 m 4 / 1 5 Standard QQQQ P01102024 100 m earth & resistivity kit 100 m 10 m 100 m 100 m 33 m 4 / 1 5 Prestige QQQQ P01102025 166 m earth & resistivity kit 100 m 10 m 166 m 166 m 33 m 4 / 1 5 Prestige QQQ P01102030 100 m add-on for resistivity 100 m 33 m 2 / - Standard QQQQ Article code Description Reels and winders Green Red Blue Black P01102026 Green cable winder 10 m P01102028 Set of 5 adapters for terminals P01102029 Set of 4 reel handles P01102031 T earth stake P01102046 Set of 3 adjustable clamps P01102047 10 m black cable H winder 10 m P01120310 C172 clamp P01295260 166 m reel of red cable 166 m P01295261 100 m reel of red cable 100 m P01295262 50 m reel of red cable 50 m P01295263 166 m reel of blue cable 166 m P01295264 100 m reel of blue cable 100 m P01295265 50 m reel of blue cable 50 m P01295266 100 m reel of green cable 100 m P01295267 33 m reel of black cable 33 m P01295268 33 m reel of green cable 33 m P01295270 2 m black cable winder (2 m cable for clamps) 2 m P01295291 5 m green cable winder 5 m P01295292 5 m black cable H winder 5 m 1P Kit3P Kit4P KitAdd-on Article code Description P01102037 C.A 647x continuity kit (4 croc. clips - red, black, blue and yellow), (2 red/ black test probes), (4 x 1.5m cables, red, black, blue and yellow) QQQ P01120550 5m AmpFlex™ flexible current sensors Q P01120551 8m AmpFlex™ flexible current sensors Q P01102046 Set of 3 adjustable clamps Q P01120310 C172 clamp Q P01120335 C177 clamp Q P01120336 C177A clamp Q P01120333 C182 clamp QQ ADDITIONAL INFO Q Possibility of ordering the carrying bag:
ACCESSORIES FOR ELECTRICAL EQUIPMENT TESTERS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 105 ARTICLE CODE DESCRIPTION LENGTH C.A 6121 C.A 6155 C.A 6160 Measurement and test leads P01295097 4 mm banana cable - red + black 3 m QQ P01295137 Double crocodile cable - black 2.5 m Q P01295140 Double crocodile cable - red 2.5 m Q P01295141 Discharge lead (EURO) 2 m QQ P01295236 Double continuity cables 2.5 m Q P01295234 Power supply cable (EURO) 2 m Q P01102139 Test lead - red 4 m Q P01102136 Plug-in test cable 1.5 m Q P01102137 Test cable with separate wires 3 m Q P01102138 Black + red test lead 1.5 m Q P01102140 Green test lead 1.5 m Q P01102141 Black test probe for C.A 6155 Q P01102142 Red test probe for C.A 6155 Q P01102143 Green test probe for C.A 6155 Q P01102144 Blue test probe for C.A 6155 Q P01102145 Set of 3 black crocodile clips Q HV test guns and probes P01101919 HV test gun 2 m QQ P01102135 HV test probe for C.A 6155 Q P01101918 HV test gun 6 m QQ Remote control, indication and communication P01101916 Remote-control pedals QQ P01101917 Red / green indicator lamps QQ P01101841 DB9F-DB25M adapter QQ P01295172 DB9F-25F cable x 2 QQ P01295173 DB9F-DB9M cable no. 1 Q P01101915 MachineLink software with communication cables Q CALink software Q P01101996 CELink software with communication cables Q Fuses P01297086 F 6x32T 16 A 250 V (set of 10 fuses) QQ Q Optional accessories Q Included in the original delivery
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 106 ELECTRICAL SAFETY ACCESSORIES FOR OTHER TESTERS ARTICLE Double test probes and Kelvin clamps for pour micro-ohmmeters P01101794 10 A Kelvin clamps (set of 2), L=3 m Spade lug QQ P01101783 1A mini Kelvin clamps (set of 2) Spade lug QQ P01102056 1 A double test probe (set of 2) L=2.85m Spade lug and 4 mm banana QQ P01103065 10 A double gun-type test probe (set of 2) L= 3.15m Spade lug and 4 mm banana QQ P01103063 10 A double pivoting test probe (set of 2) L= 3.15m Spade lug and 4 mm banana QQ P01295486 Set of 2 Kelvin leads 6 m long (red / black) with adjustable-clamp connections Q P01295487 Set of 2 Kelvin leads 15 m long (red / black) with adjustable-clamp connections Q P01295488 Green earth lead with crocodile clip Q P01120470 MR6292 clamp Q Other accessory for micro-ohmmeters P01102013 Pt 100 sensor Q Measurement lead for ratiometer P01295143A Set of 2 replacement leads, H primary, X secondary L= 4.6m , compatible with DTR 8500 / DTR 8510 4 mm banana Q Adapters for cable and metal conductor locator P01102114Z Kit of 3 measurement adapters for housing (B22, E27, mains socket) B22 bayonet E27 screw socket 2P mains socket Q Measurement lead for battery capacity tester P01102103 Set of 2 double-contact current / voltage measurement leads for C.A 6630 battery tester. L=1m Jack Q Q Optional accessories Q Included in the original delivery
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 107 ELECTRICAL SAFETY ACCESSORIES / REPLACEMENT PARTS C.A 6030 C.A 6501 and C.A 6503 C.A 6511 and C.A 6513 Q Elbowed-straight safety leads (red + black) 1.5 m long __ P01295453Z C.A 6541 and C.A 6543 Q Fuse F 2.5 A - 1,200 V - 8 x 50 mm - 15 kA (x 5) _______ P01297071 Q Fuse F 0.1 A - 660 V - 6.3 x 32 mm - 20 kA (x 10) _______ P01297072 C.A 6543 Q RS 232 printer DB 9F - DB 9M cable no. 01 ___________ P01295173 C.A 6505, C.A 6545, C.A 6547 and C.A 6549 Q Fuse FF 0.1 A - 380 V - 5 x 20 mm - 10 kA (x 10) _______ P03297514 INSTALLATION TESTERS INSULATION TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 108 ELECTRICAL SAFETY ACCESSORIES / REPLACEMENT PARTS C.A 6547 and C.A 6549 Q RS 232 printer DB 9F - DB 9M cable no. 01 ___________ P01295173 C.A 6550 and C.A 6555 MULTIMETER CLAMPS FOR LEAKAGE CURRENT F62 and F65 Q Elbowed test-probe leads, 1.5 m, (1 red/1 black) _______ P01295456Z Q Soft case 200 x 100 x 40 mm with belt clip ___________ P01298065Z Q C.A 801 single-channel temperature adapter __________ P01652401Z Q 2-channel temperature adapter with differential Q Shoulder bag no. 21 (250 x 165 x 60 mm) with strap ____ P06239502 C.A 6421 and C.A 6423 C.A 6416 and C.A 6417 C.A 6460 and C.A 6462 C.A 6470N, C.A 6471 and C.A 6472 Q Adapter for battery charging on vehicle cigarette lighter __ P01102036 Q Set of 10 fuses: F 0.63 A - 250 V - 5 x 20 mm - 1.5 kA ___ AT0094 Q Adapter for battery charging on the mains supply ______ P01102035 EARTH AND RESISTIVITY TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 109 ELECTRICAL SAFETY ACCESSORIES / REPLACEMENT PARTS C.A 6155 C.A 6471 and C.A 6472 Q MN82 clamp (diam. 20 mm) delivered with 2 m cable for connection to ES terminal __________ P01120452 Q C182 clamp (diam. 52 mm) delivered with 2 m cable for connection to ES terminal __________ P01120333 C.A 6474 Q Set of 12 identification rings for AmpFlex® ___________ P01102045 Q 5 m green cable (E terminal connection) _____________ P01295291 Q 5 m black cable (E terminal connection) _____________ P01295292 EARTH AND RESISTIVITY TESTERS C.A 6121 Q Machine Link Windows processing software Q Roll of paper for series printer (set of 5) _____________ P01101842 ELECTRICAL EQUIPMENT TESTERS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 110 C.A 6240 and C.A 6255 Q Straight probe with 10 A double pivoting retractable Q Gun with 10 A double retractable test probe (x 2) _______ P01103065 C.A 6240 C.A 6255 C.A 6292 Q 1 set of 2 Kelvin leads 6 m long (red / black) Q 1 set of 2 Kelvin leads 15 m long (red / black) DTR 8510 C.A 6681 Q 33 m reel of green wire, battery clip/4 mm male Q 15 m reel of green wire, battery clip/4 mm male Q 10 m reel of green wire, battery clip/4 mm male Q Kit of 3 measurement adapters for housing C.A 6630 Q Set of 2 leads with retractable test probes ___________ P01102103 OTHER TESTERS SEE ALL OUR ACCESSORIES ON PAGE 230 ACCESSORIES / REPLACEMENT PARTS ELECTRICAL SAFETY
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 111 ELECTRICAL SAFETY NOTES
& INSTALLATION MONITORING Info and advice 114 Power and harmonics clamps 118 Power and energy quality analysers 122 Electrical measurement loggers 126 Physical measurement loggers 136 Solar power analysers 139 Data processing software 142 Accessories 144
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 114 POWER AND DISTURBANCES POWER MEASUREMENTS TROUBLESHOOTING DISTURBANCES A phase of analysis is essential to precisely identify the behaviour of the installations and determine which solutions to implement. The measurements made help to ensure that the solutions are pertinent and that the gains achieved are maintained over the long term in the context of an energy optimization programme. So measurement provides the foundation for optimizing your installations’ energy efficiency , supervising your electrical networks and fairly allocating the costs. Power measurement is a key element for the definition, success and long-term effects of an energy optimization programme. Reducing electricity consumption is also a simple, painless way of saving money. Electricity is a clean energy source which is less harmful for the environment, but it does affect it nevertheless. The various parameters of the installation are measured regularly, including the different power values used to size the electrical network and the phase shift data, as well as the voltage, current and frequency measurements. For private customers, reactive power is neither measured nor billed separately. Instead is it included at a flat rate in the active power price. Things are very different for industrial customers, however. Electricity suppliers penalize consumers whose displacement power factor (cos phi or DPF) is lower than 0.93 (in France) or whose tan phi is higher than 0.4 (in France). This set of measurements will help the installation manager to size the capacitor banks correctly. With the spread of systems incorporating electronics using switching power supplies, the electrical network is becoming increasingly polluted. A further complication is the fact that electricity market deregulation could lead to more frequent general network blackouts. The quality requirements have become much more demanding and stringent than in the past. All the equipment in factories and buildings now includes digital electronics which are known to be sensitive to micro-outages, peaks and dips, harmonics and disturbances in general. The complexity of industrial equipment makes it vulnerable to the voltage disturbances that occur on the electrical network. The arrival of new quick-switching components is leading to a large number of low-order harmonic currents
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 115 Some faults are encountered very frequently. In general, most disturbances are caused by: Slow and transient voltage variations. The voltage amplitude is a crucial parameter for electricity quality. The voltage amplitude varies abnormally and may even drop to a level close to zero. The causes mainly lie in the installation itself. The connection of heavy loads may lead to voltage variations if the short-circuit power at a point of supply is undersized. Several types of faults are then defined: overvoltage, voltage dip, outage, etc. The rated network voltage variation range is set by the power distributor. Flicker: rapid voltage fluctuations. When variable loads s u c h a s a r c f u r n a c e s , l a s e r printers, microwave ovens or air-conditioning systems are started up, they cause rapid voltage variations . This phenomenon is called flicker. In reality, the flicker value is the result of a statistical calculation based on measurements of the rapid voltage variations. A 10-minute interval is considered an acceptable compromise for evaluation of the short-term flicker (Pst). If the combined effect of several disturbance-generating loads operating in a random way (e.g. welding units or motors) has to be taken into account or when flicker sources with long or variable operating cycles are involved (electric arc furnace), the resulting disturbance must be assessed over a longer time. The measurement duration defined is then 2 hours, a time considered appropriate for the load operating cycle or the time during which an observer may be sensitive to long-term flicker (Plt). Harmonics and interharmonics. The waveform of the current consumed by loads connected to the electrical network is often no longer purely sinusoidal. This current distortion implies distortion of the voltage wich also depends on the impedance of the source. The disturbances called harmonics are caused by connecting non-linear loads, such as equipment incorporating power electronics, to the network . This may have instant consequences on certain electronic equipment: operating problems (synchronization, switching), untimely tripping, measurement errors on energy meters, etc. In the medium term, the extra heating caused by this may reduce the life span of rotating machines, capacitors, power transformers and neutral conductors. Today’s measuring instruments have to be capable of performing this harmonic analysis order by order, as well as measuring the Total Harmonic Distortion (THD) for more detailed diagnosis of the installation. Electrical network analysers capable of recording disturbances for industrial companies and professionals in the electricity sector (producers, transmission companies, electricity users) are essential tools for satisfactory supervision and timely maintenance of installations. They have to provide direct measurements, allow as much parameterization as possible for recording and facilitate subsequent analysis.
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 116 DATA LOGGING MADE SIMPLE The data logger family is a cost-effective, advanced- design product line incorporating features and functions not found in data loggers costing 2 to 3 times their price. The choice of data storage modes and storage rates allows the operator to effortlessly configure these loggers to optimize memory usage for the application required. Extended Recording Mode (XRM™) and delayed start time are just two of the many application-friendly features in these loggers. A n i n t e r n a l m e m o ry o f 5 1 2 k B a l l o w s s t o r a g e o f o v e r 240,000 measurements, more than enough for most data collection needs. All the AC measurement loggers are True RMS (TRMS) and all the DC measurement loggers allow the user to program both scale and engineering units. A full set of alarm programming tools allows programming of alarm set points and triggering on high, low, inside or outside trigger points. Their battery operation and compact size allow installation in locations where space is restricted without the need for external power. A series of front-panel LEDs provides a quick overview of the logger’s state and memory usage. Software is included as standard, providing real-time viewing of measurement data even while recording. Instrument configuration, data storage and report generation from predefined templates or operator custom- designed templates are also standard features. In addition, several data loggers can be synchronized to record at the same time intervals using DataView
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 117 MAIN ADVANTAGES APPLICATIONS Q True RMS measurements provide an accurate representation of measured signals for AC models Q Choice of data storage modes to assist in matching the data collection to the needs of the application Q Stores over 240,000 measurements, ensuring that no valuable data is missed (more than 8 hours at 8 samples per second; approximately 1 week at one sample every 2 seconds) Q Compact size and battery operation Q Display and analyse real-time data through your PC Q DataView® helps electricians or engineers to detect problems occurring randomly during fault/intermittent current detection Q Neutral current monitoring to detect unwanted leakage currents Q Real-time current harmonics monitoring to locate unwanted energy which causes equipment failure Q Load profiling which sizes loads for proper transformer and meter selection Q Split-phase load monitoring for residential voltage and current Q Machine load monitoring detects overload conditions causing premature equipment failure due to overheating Q Process loop monitoring can detect problematic sensors and control systems Q HVAC and general temperature profiling (refrigeration and air-conditioning systems)
CHOOSE YOUR POWER ANALYSER / POWER CLAMP ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 118 C.A 404 page 214 C.A 405 page 214 F205 page 43 F407 page 120 F607 page 121 C.A 8220 page 122 C.A 8230 page 123 Strengths Specially for education For small and medium power values Power and harmonics in a clamp Specially for motor maintenance Specially for electrical network maintenance Number of U / I input channels 1111111 Current (A) 1 5 600 1,000 2,000 Depending on sensors Depending on sensors Display Analogue QQ Digital QQQQQ Scope mode Q Electrical network Single-phase QQQQQQQ Balanced three-phase QQQQQQ Three-phase Measurements DC voltage QQQQQ AC voltage QQQQQ DC current QQQQQ AC current QQQQQ Frequency QQQQQ Power VA (S) QQQQQ W (P) QQQQQQQ var (Q1) QQQQQ var (D) var (N) Q Cos φ / DPF QQQQ PF QQQQQ Tan φ Q Energy VAh, Wh, varh QQQQ Harmonics THD-r QQQQQ THD-f QQQQ Decomposition QQQQ Others PST flicker Q PLT flicker Sliding PLT flicker Unbalance Temperature Q Resistance QQQQ Rotation speed Q Monitoring Recording QQ Q Transients Alarms Q PC software QQQQ
CHOOSE YOUR POWER ANALYSER / POWER CLAMP ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 119 C.A 8331 page 124 C.A 8333 page 124 C.A 8336 page 124 Comfortable to handle and very compact Ideal for installation maintenance Top-of-the-range analysers Strengths Number of U / I input channels 334 Current Depending on sensors Depending on sensors Depending on sensors (A) Display Analogue QQQ Digital QQQ Scope mode Electrical network QQQ Single-phase QQQ Balanced three-phase QQQ Three-phase Measurements QQQ DC voltage QQQ AC voltage QQQ DC current QQQ AC current QQQ Frequency Power QQQ VA (S) QQQ W (P) QQQ var (Q1) QQQ var (D) QQQ var (N) QQQ Cos φ / DPF QQQ PF QQQ Tan φ Energy QQQ VAh, Wh, varh Harmonics QQQ THD-r QQQ THD-f QQQ Decomposition Others QQQ PST flicker Q PLT flicker Q Sliding PLT flicker QQQ Unbalance Temperature Resistance Rotation speed Monitoring QQQ Recording QQ Transients QQ Alarms PC software QQQ
POWER AND HARMONICS MULTIMETER CLAMPS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 120 1000 V CAT IV IP 1 000 AAC Ø 48 mm F407 Ref. : P01120947 STRENGTHS Q Measurements up to 1,000 AAC or 1,500 ADC or AAC+DC Q Clamping Ø 48 mm Q Harmonic analysis up to the 25th order Q TrueInrush function Q 3-year warranty Q F407 delivered in a bag pre-equipped for MultiFix Q 1 set of banana/banana leads (red/black) Q 1 set of test probes (red/black) Q 1 set of crocodile clips (red/black) Q 4 x 1.5 V LR6 batteries Q 1 safety datasheet Q 1 CD-Rom containing a user manual and the PC data recovery software (Power Analyser Transfer) ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS F407 Current(RMS) AC 100 mA to 1,000 A DC and AC+DC 100 mA to 1,500 A Best accuracy 1 % L + 3 counts Voltage (RMS) AC 100 mV to 1,000 V DC and AC+DC 100 mV to 1,000 V Best accuracy 1 % L + 3 counts Auto AC/DC Yes (V and A) Resistance 100 kΩ Continuity/buzzer Yes (< 40 Ω) Power W (P), var (Q1), VA (S) Yes, single and total three-phase Crest factor (CF) Yes PF and cos φ (DPF) Yes / Yes Auto power-off Yes Hold function Yes Backlighting function Yes Min Max key Yes Peak +/- 100 ms function Yes / Yes TrueInrush function Yes THD-f / THD-r harmonics function Yes / Yes Decomposition into harmonic orders 25th order REC storage function Yes Recordings (with Min, Max) Up to 3,000 measurements Bluetooth communication function Yes Frequency 15 Hz to 20 kHz Clamping Ø 48 mm Protection IP 54 Electrical safety IEC 61010
1000 V CAT IV
Dimensions / weight 272 x 92 x 41 mm - 600 g (with batteries)
POWER AND HARMONICS MULTIMETER CLAMPS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 121 1000 V CAT IV IP 2 000 AAC Ø 60 mm F607 Ref. : P01120967 STRENGTHS Q Measurements up to 2,000 Aac or 3,000 Adc or Aac+dc Q Clamping Ø 60 mm Q Harmonic analysis up to the 25th order Q TrueInrush function Q 3-year warranty Q F607 delivered in a bag pre-equipped for MultiFix Q 1 set of banana/banana leads (red/black) Q 1 set of test probes (red/black) Q 1 set of crocodile clips (red/black) Q 4 x 1.5 V LR6 batteries Q 1 safety datasheet Q 1 CD-Rom containing 1 user manual and the PC data recovery software (Power Analyser Transfer) ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS F607 Current(RMS) AC 100 mA to 2,000 A DC and AC+DC 100 mA to 3,000 A Best accuracy 1 % L + 3 counts Voltage (RMS) AC 100 mV to 1,000 V DC and AC+DC 100 mV to 1,000 V Best accuracy 1 % L + 3 counts Auto AC/DC Yes (V and A) Resistance 100 kΩ Continuity/buzzer Yes (< 40 Ω) Power W (P), var (Q1), VA (S) Yes, single and total three-phase Crest factor (CF) Yes PF and cos φ (DPF) Yes / Yes Auto power-off Yes Hold function Yes Backlighting function Yes Min Max key Yes Peak +/- 100 ms function Yes / Yes TrueInrush function Yes THD-f / THD-r harmonics function Yes / Yes Decomposition into harmonic orders 25th order REC storage function Yes Recordings (with Min, Max) Up to 3,000 measurements Bluetooth communication function Yes Frequency 15 Hz to 20 kHz Clamping Ø 60 mm Protection IP 54 Electrical safety IEC 61010 Dimensions / weight 296 x 111 x 41 mm - 640 g (with batteries)
POWER AND ENERGY QUALITY ANALYSERS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 122 600 V CAT III IP C.A 8220 Ref. : P01160620 STRENGTHS Q Access to all the measurements simultaneously Q Low resistance and high current measurements Q Motor temperature measurement Q Motor rotation speed Q C.A 8220 Q 2 banana leads Q 2 x 4 mm test probes Q 2 crocodile clips Q 6 x 1.5 V LR06 batteries Q 1 optical USB cable Q Power Analyser Transfer processing software Q 1 CD-ROM containing the user manual ADDITIONAL INFO Q The C.A 8220 analyser is also available with a current sensor: ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS C.A 8220 Voltage (TRMS) Phase/Phase : 660 VAC+DC Phase/Neutral : 600 VAC+DC Current (TRMS) MN MN93: 2 to 240 AAC ; MN93A: 0.005 AAC to 5 AAC / 0.1 AAC to 120 AAC C 3 A to 1,200 A AC AmpFlex® or MiniFlex® 30 A to 6,500 AAC PAC 10 A to 1,000 A AC / 10 A to 1,400 ADC E3N 50 mA to 10 A AC+DC, 100 mA to 100 AAC+DC Frequency 40 Hz to 70 Hz Other measurements W (P), var (Q1), PF, DPF, VA (S), temperature, phase rotation, RPM, resistance, continuity, diode test, Wh, VAh, varh Harmonics 1st to 50th order Sampling rate 256 samples/period Recording capacity ≥ 9 complete sets of voltage, current, power and harmonics measurements Power supply 6 x 1.5 V LR06 batteries, mains power supply available as an option Battery life ≥ 8 hours with display activated Communication Optical USB Display Backlit 3-display screen with symbols Dimensions / weight 211 x 108 x 60 mm / 0.88 kg Electrical safety IEC 61010 600 V CAT III, pollution degree 2 MOTOR MAINTENANCE
POWER AND ENERGY QUALITY ANALYSERS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 123 600 V CAT III IP C.A 8230 Ref. : P01160630 STRENGTHS Q Access to all the measurements simultaneously Q INRUSH function covering up to 18 s Q Colour graphical display Q Recording and alarms Q C.A 8230 Q 2 banana leads Q 2 x 4 mm crocodile clips Q 2 crocodile clips Q 6 rechargeable NIMH batteries Q 1 x 230 V mains adapter Q 1 optical USB cable Q 1 bag no. 5 Q Power Analyser Transfer processing software Q 1 CD-ROM containing the user manual ADDITIONAL INFO Q The C.A 8230 analyser is also available with a current sensor: ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS C.A 8230 Voltage (TRMS) Phase/Phase : 660 V Phase/Neutral : 600 V Current (TRMS) MN MN93 : 2 to 240 AAC ; MN93A : 0.005 AAC to 5 AAC / 0.1 AAC to 120 AAC C 3 A to 1,200 A AC AmpFlex® or MiniFlex® 30 A to 6,500 AAC PAC 10 A to 1,000 A AC / 10 A to 1,400 ADC E3N 50 mA to 10 A AC+DC, 100 mA to 100 AAC+DC Frequency 40 Hz to 70 Hz Other measurements VA (S), W (P), var (Q1, N), PF, DPF, Wh, varh, VAh, K factor, flicker, harmonic phase shift, phase rotation Harmonics THD, V, A, VA 1st to 50th order: direction, sequence Sampling rate 256 samples/cycle Recording capacity 1.5 MB partitioned for the waveforms, alarms and trend recordings Power supply 6 rechargeable NiMH batteries (supplied) AC power supply: 120/230 Vac (50/60 Hz) Battery life ≥ 8 h with display activated ≥ 40 with display deactivated (recording mode) Communication Optical USB Display ¼ VGA colour LCD (320 x 240) Dimensions / weight 211 x 108 x 60 mm / 0.88 kg Electrical safety IEC 61010 600 V CAT III, pollution degree 2 ELECTRICAL NETWORK MAINTENANCE
NETWORK AND THREE-PHASE ENERGY ANALYSERS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 124 1000 V CAT III IP 600 V CAT IV EN 50160 IEC 61000-4-30 C.A 8331 - C.A 8333 - C.A 8336 Ref. : P01160511 P01160541 P01160591 STRENGTHS Q TRMS AC+DC voltage and current, frequency Q Measurements for power surveys Q Measurements for sizing the anti-harmonic filters Q Simultaneous recording of all the parameters Q Capture of all the transients, alarms and waveforms ADDITIONAL INFO Q The Power Analyser Transfer PC data recovery software is supplied as standard Q C.A 8331 / C.A 8333 / C.A 8336 delivered with: Q 1 bag No. 22 Q 1 USB lead Q 1 mains adapter Q 4 x 4 mm banana voltage leads 3 m long (5 leads for C.A 8336) Q 4 crocodile clips (5 clips for C.A 8336) Q 1 safety datasheet Q 1 set of 12-colour markers for identifying the leads and inputs Q 1 anti-scratch screen protection film (mounted) Q 1 CD-ROM containing the Power Analyser Transfer PC data recovery software Don’t forget to order your current sensors - see page 144 ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144
NETWORK AND THREE-PHASE ENERGY ANALYSERS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 125 FUNCTIONS Q Real-time waveform display (5 voltage inputs and 4 current inputs) Q ½-period RMS voltage and current measurements Q Intuitive use Q Automatic recognition of the different types of current sensors Q Integration of all the DC components Q Voltage and current ratios Q Mixing of current sensors Q Measurement, calculation and display of the harmonics up to the 50th order, along with their phase information Q Calculation of the Total Harmonic Distortion (THD) Q Transient capture down to a single sample (1/256th of a period) Q Display of phasor diagram Q Measurement of power values: VA, W, VAD, total var and var per phase Q Measurement of energy values: VAh, Wh, VADh, total varh and varh per phase Q Calculation of K factor and FHL Q Calculation of cos φ displacement power factor and (DPF) and power factor (PF) Q Capture of up to 210 transients Q Calculation of PST & PLT Flicker Q Calculation of unbalance (current and voltage) Q Monitoring of the electrical network with setting of alarms Q Backup and recording of screenshots (image and data) Q Recording and export on PC Q Real-time data recovery and communication software on PC Q EN 50160 reports SPECIFICATIONS C.A 8331 C.A 8333 C.A 8336 Number of channels 3U / 4I 4U / 4I Number of inputs 4V / 3I 5V / 4I IEC 61000-4-30 - EN50160 reports Voltage (TRMS AC+DC) 2 V to 1,000 V Voltage ratio Up to 500 kV Current (TRMS AC+DC) MN MN93 : 500 mA to 200 AAC ; MN93A : 0.005 AAC to 100 AAC C193 1 A to 1,000 AAC AmpFLEX™ or MiniFlex® 100 mA to 10,000 AAC PAC93 1 A to 1,300 AAC/DC E3N 50 mA to 100 AAC/DC Current ratio Up to 60 kA Frequency 40 Hz to 69 Hz Power values W (P), VA (S), var (Q1, N, D), PF, DPF, cos φ, tan φ Energy values Wh, varh (Q1h, Nh, Dh), VAh Harmonics Yes THD Yes, 0 to 50th order, phase Expert mode - Yes Transients - 50 210 Flicker Pst Pst and Plt Inrush mode - Yes on 4 periods Yes > 10 minutes Unbalance Yes Recording Min/Max Yes parameters at the max. sampling rate 4 hours to 2 weeks A few days to several weeks 2 weeks to several years Alarms - 4,000 of 10 different types 10,000 of 40 different types Peak Yes Vectorial representation Automatic Display ¼ VGA colour TFT screen, 320 x 240, diagonal 148 mm Capture of screens and curves 12 50 Electrical safety IEC 61010 1000 V CAT III / 600 V CAT IV Protection rating IP53 / IK08 Languages More than 27 Communication interface USB Battery life Up to 10 hours Power supply Rechargeable 9.6 V NiMH battery or mains power supply Dimensions / weight 240 x 180 x 55 mm / 1.9 kg
CHOOSE YOUR ELECTRICAL MEASUREMENT LOGGER ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 126 PEL103 page 128 PEL102 page 128 PEL105 page 129 L562 page 130 CL601 page 131 L101 page 132 With display QQ Without display Q QQQ Power Power values QQQQ Energy values QQQ Current Clamp format Q Voltage inputs (format) Qualistar Qualistar Qualistar BNC BNC Current inputs (format) Number of inputs 334111 Voltage RMS QQQQ DC QQQ Number of inputs 3341
CHOOSE YOUR ELECTRICAL MEASUREMENT LOGGER ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 127 L102 page 132 L111 page 132 ML912 page 133 ML914 page 134 AL834 page 134 L261 page 135 L481 page 135 With display QQQQQQQ Without display Power Power values Energy values Current Clamp format BNC Banana Banana Voltage inputs (format) Banana Current inputs (format)
21244 Number of inputs
See acc. See acc. MiniFlex ® MiniFlex® AmpFlex® Sensor type Voltage Q RMS QQ DC
11 Number of inputs
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 128 1000 V CAT III 600 V CAT IV IP PEL 102 - PEL 103 Ref. : P01157152 P01157153 ADDITIONAL INFO The PEL Transfer analysis software is delivered as standard for: Q Configuration of the PEL100s Q Verification of the connections before recording starts Q Downloading of the recorded measurements Q Display of the various measurement results and analyses STRENGTHS Q Compatible with all electrical networks: single-phase, split-phase, three-phase with or without neutral, etc. Q Implementation without powering down the electrical network Q All the instruments can be powered by the phase Q Data recording on integrated SD card Q Compact and magnetized for mounting in closed cabinets Q A PEL 102 or PEL 103 logger delivered with: Q 4 measurement leads Q 4 crocodile clips (black) Q 1 x 2 GB SD card Q 1 set of markers (for the ends of the leads and current sensors) Q 1 mains power cable Q 1 USB cable (Type A / Type B) Q 1 carrying bag Q 1 safety datasheet Q PEL Transfer PC software Q 1 SD USB adapter Q 1 CD-ROM containing the user manual ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS PEL 102 PEL 103 Display None With triple digital display Type of installation Single-phase, split-phase, three-phase with or without neutral, etc. Number of channels 3U / 4I Number of inputs 4U / 3I Measurements Network frequency DC, 50 Hz, 60 Hz & 400 Hz Voltage (measurement range) 10.00 to 1,000 VAC/DC Current MN93 500 mA to 200 AAC MN93A 5 mA to 100 AAC C193 1 A to 1,000 AAC AmpFlex® A193 & MiniFlex® MA193 200.0 mA to 10.00 kAAC PAC93 1 A to 1,000 AAC
1 A to 1,300 ADC
J93 50 A to 3,500 AAC / 50 A to 5,000 ADC Calculated Measurements Ratios Up to 650,000 V / up to 25,000 A Power 10 W to 10 GW / 10 var to 10 Gvar (N)
10 VA to 10 GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018) Phase cos φ, tan Φ, PF Harmonics THD Additional functions Phase sequence Yes Min / Max Yes Mounting Magnet, hook Recording Sampling rate / Acquisition interval / Aggregation 128 samples/period - 1 measurement/s from 1 min to 60 min Data storage SD card, 8 GB (SD-HC card up to 32 GB) Communication USB, Ethernet & BlueTooth Power supply 110 V - 250 V (+10 %, -15 %) @ 50-60 Hz & 400 Hz Safety IEC 61010 600 V CAT IV
1000 V CAT III
Dimensions 256 x 125 x 37 mm without sensor Weight 900 g 950 g Casing IP54, ETL
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 129 1000 V CAT IV IP PEL 105 Ref. : P01157155 ADDITIONAL INFO Q When used with the DataView® software, the measurements made with the PEL105 can be processed directly for measurement report generation. Q Possibility of remote connection via an IRD server STRENGTHS Q Suitable for installation on an electricity pole Q All-terrain casing resistant to shocks, UV light and high temperatures Q Self-powered by its voltage inputs up to 1,000 V Q Continuous recording with a 200 ms acquisition interval Q Measurements in compliance with the IEEE 1459 standards Q One PEL105 logger delivered with: Q 5 black silicone leads 3 m long, straight banana / straight banana Q 5 black crocodile clips, 1000 V CAT IV Q 1 set of inserts/rings Q 4 AmpFlex® IP67 A196 3 m long Q 1 set of waterproof caps Q 1 SD card Q 1 USB cable Q 1 bag Q 1 safety datasheet Q 1 USB key containing a quick startup guide and a user manual ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS PEL 105 Display With triple digital display Type of installation Single-phase, split-phase, three-phase with or without neutral, etc. Number of channels 4U / 4I Number of inputs 5U / 4I Measurements Network frequencies DC, 50 Hz, 60 Hz & 400 Hz Voltage (measurement range) 10.00 V to 1,000 V AC/DC @ 50/60 Hz
600 VAC @ 400 Hz
C193 1 A to 1,000 AAC AmpFlex® A193 & MiniFlex® MA193 200 mA to 10 kAAC PAC93 1 A to 1,000 AAC / 1 A to 1,300 ADC E3N 50 mA to 10 AAC/DC / 100 mA to 100 AAC/DC J93 50 to 3,500 AAC / 50 to 5,000 ADC Calculated measurements Power 20 W to 10 GW 20 var to 10 Gvar (Q1, N)
20 VA to 10 GVA
Energy Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018) Phase cos φ, tan Φ, PF Harmonics THD Additional functions Phase sequence Yes Min / Max Yes Recording Sampling rate / Acquisition interval / Aggregation 128 samples./period 5 measurements/s From 1 min to 60 min Data storage 8 GB SD card (SD-HC card up to 32 GB) Communication Ethernet, Bluetooth®, WiFi and USB Power supply Self-powered internally from 94 to 1,000 V @ 50-60 Hz & 400 Hz / DC Safety IEC 61010 - 1000 V CAT IV Mechanical specifications Dimensions 245 x 270 x 180 mm Weight < 4 kg Casing IP67
TRMS VOLTAGE/CURRENT LOGGER ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 130 600 V CAT III 300 V CAT IV TRMS L562 Ref. : P01157060 STRENGTHS Q Detects voltage drops and surges Q Monitors power consumption on single-phase networks, as well as energy consumption Q Up to 240,000 measurements saved in non-volatile memory Q Recording rate from 8/s to 1/day Q L562 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 banana leads 1.5 m long Q 2 crocodile clips Q 2 x 1.5 V LR06 alkaline batteries ADDITIONAL INFO Q Automatic report generation with the DataView® software ACCESSORIES / REPLACEMENT PARTS Q Standard PVC leads with straight 4 mm male plugs ______P01295288Z Q See all the accessories on page 144 SPECIFICATIONS L562 Number of channels 2 Connection Current channel Voltage channel Input connection BNC Banana connector Input range 0 to 1 VAC 0 to 600 VAC Resolution 0,1 mV 0,1 V Accuracy (50/60 Hz) 0 to 10 mV: not specified 10 to 50 mV: ± (0.5 % R + 1 mV) 50 to 1,000 mV: 0 to 5 V: not specified 5 to 50 V: ± (0.5 % R + 1 V) 50 to 600 V: Sampling rate 64 samples per period Storage interval Programmable from 125 ms to 1 day Recording modes Stop when full, FIFO, XRM™ extended recording mode and recording on alarms Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 136 x 70 x 32 mm Max. conductor sizes Depends on current sensor Weight (with battery) 181 g Casing UL94-V0 Vibration IEC 60068-2-6 (1,5 mm, 10 à 55 Hz) Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 131 600 V CAT III 300 V CAT IV TRMS CL601 Ref. : P01157010 STRENGTHS Q Stand-alone with safe connections Q Alarm function Q Overload indication Q Monitoring of machine loads, electrical troubleshooting, etc. ADDITIONAL INFO Q Automatic report generation Q CL601 delivered with: Q 1 USB cable 2 m long, type A to mini-B Q 5 pins Q PC communication software Q 2 x 1.5 V LR06 batteries SPECIFICATIONS CL601 Number of channels 1 Input connection Split-phase current transformer AC current Current range 0 to 600 AAC Resolution 0,1 A Accuracy (50/60 Hz) 0 to 5 A: not specified 5 to 50 A: ± (1 % R + 1 A) 50 to 400 A: ±(1 % R + 0.5 A) 400 to 600 A: ±(3 % R + 1 A) Sampling rate 64 samples per period Storage interval Programmable from 125 ms to 1 day Storage modes Start/end, FIFO and XRM™ extended recording mode Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 235 x 102 x 41 mm Max. conductor size 1 conductor Ø 42 mm, 2 conductors each with Ø 25.4 mm Weight (with batteries) 485 g Electrical safety IEC 61010, 300 V CAT IV / 600 V CAT III Casing UL94-V0 Vibration IEC 60068-2-6 (1.5 mm, 10 to 55 Hz) Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 132 50 V CAT III TRMS L101 - L102 - L111 Ref. : P01157020 P01157030 P01157080 STRENGTHS Q L101 records on request and can be used to monitor current on 1 channel Q L102 can be used to monitor the neutral current in relation to the earth, as well as split-phase loads It is equipped with 2 independent channels Q L111 has the same function as the L101 but with single- channelnnection via banana socket for clamps with current output Q L101 and L102 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 x 1.5 V LR6 batteries Q L111 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 x 1.5 V LR06 batteries ADDITIONAL INFO Q Automatic report generation ACCESSORIES / REPLACEMENT PARTS Q USB cable 2 m long, type A to mini-B 5-pin _____________Contact us Q See all the accessories on page 144 SPECIFICATIONS L101 L102 L111 Number of channels 121 Input connection BNC One BNC connector per channel 2 flush-mounted banana sockets Current range 0 to 1 VAC depending on sensor Resolution 0,1 mV 0,1 mA Accuracy (50/60 Hz) 0 to 10 mV: not specified 10 to 50 mV: ± (0.5 % R + 1 mV) 50 to 1,000 mV: 0 to 10 mA: not specified 10 to 50 mA: ± (0.5 % R + 1 mA) 50 to 1,000 mA: ± (0.5 % R + 0.5 mA) Sampling rate 64 samples per period Storage interval Programmable from 125 ms to 1 day Storage modes Start/end, FIFO, XRM™ extended recording mode and recording on alarms Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 136 x 70 x 32 mm 132 x 70 x 32 mm Max. conductor size Depends on current sensor Weight (with batteries) 180 g Electrical safety IEC 61010, 50 V CAT III Casing UL94-V0 Vibration IEC 60068-2-6 (1,5 mm, 10 to 55 Hz) Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 133 600 V CAT III 300 V CAT IV ML912 Ref. : P01157130 STRENGTHS Q Two MiniFlex® flexible current sensors for measuring currents from 0.5 A to 1,000 A Q Two ranges: 100 / 1,000 Aac Q Monitoring of loads on the phase Q Intermittent fault detection Q Monitoring of current harmonics Q ML912 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 x 1.5 V LR06 batteries ADDITIONAL INFO Q Automatic report generation ACCESSORIES / REPLACEMENT PARTS Q USB cable 2 m long, type A to mini-B 5-pin _____________Contact us Q See all the accessories on page 144 SPECIFICATIONS ML912 Number of channels 2 Input connection Built-in MiniFlex® flexible AC current sensors Range 0.5 to 100 AAC 5 to 1,000 AAC Resolution 0.1 mA 0.1 V Accuracy 0 to 1 A: not specified 1 to 100 A: ±(1 % R + 0.5 A) 0 to 5 A: not specified 5 to 1,000 A: ±(1 % R + 1 A) Sampling rate 64 samples per period Storage interval Programmable from 125 ms to 1 day Storage modes Start/stop, FIFO, XRM™ extended recording mode and recording on alarms Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 136 x 70 x 32 mm without sensor Weight (with batteries) 245 g Electrical safety IEC 61010-1, 600 V CAT III, 300 V CAT IV, Pollution degree 2 Casing UL94-V0 Vibration IEC 60068-2-6 Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C Safety - electromagnetic compatibility Safety IEC 61010-1 ; 600 V CAT IV ; Pollution degree 2 Protection IP40
CURRENT LOGGERS WITH FLEXIBLE SENSORS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 134 600 V CAT IV 1000 V CAT III IP
65 TRMS
Ref. : P01157135 P01157140 STRENGTHS Q Compact current loggers with flexible sensors Q TRMS measurements up to 1,000 AAC (ML914) or 3,000 AAC (AL 834) Q Safe, accessible, risk-free measurements via the Bluetooth communication function Q DataView® software for effective analysis of your measurements Q ML 914 delivered with: Q PC communication software Q 4 type-C batteries Q 1 CD-ROM containing the user manual Q 1 safety datasheet Q AL 834 delivered with: Q PC communication software Q 4 x 1.5 V LR14 batteries Q 1 CD-ROM containing the user manual Q 1 safety datasheet ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS ML914 AL 834 Number of channels 4 Type of sensor Built-in MiniFlex® Built-in flexible sensors Range 100 A 1,000 A 300 A 3,000 A Accuracy (50/60 Hz) 0 to 1 A: not specified 1 to 100 A: ± (1% R + 0.5 A) 0 to 5 A: not specified 5 to 1,000 A: ± (1% R + 1 A) 0 to 5 A: not specified 1 to 300 A: ± (1% R + 0.5 A) 0 to 15 A: not specified 15 to 3,000 A: ± (1% R + 1 A) Resolution 0.1 V Sampling rate 64 samples per period Acquisition interval Programmable from 125 ms to 1 day Storage modes Start/stop, FIFO, XRM™ extended mode and on alarm Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 1,000,000 measurements (2 MB) Communication BlueTooth® (Class 2) Power supply 4 x 1.5 V LR14 batteries Battery life Up to 180 days Safety IEC 61010 600 V CAT IV and 1000 V CAT III Mechanical specifications Dimensions 150 x 150 x 90 mm without sensor 150 x 150 x 91 mm without sensor Max. conductor size 45 mm 203 mm Weight 1.1 kg 1.77 kg Casing IP50 as per IEC 60529 IP65 as per IEC 60529
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 135 600 V CAT III 300 V CAT IV TRMS L261 - L481 Ref. : P01157040 P01157110 STRENGTHS Q L261 Q 600 VAC/DC TRMS Q Suitable for industrial, commercial or residential monitoring Q Recording of voltage drops and surges Q L481 Q 850 VDC Q Voltage monitoring on machines, wind turbines, railway applications, etc. Q Detection of intermittent voltage faults Q L261 and L481 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 banana leads Q 2 voltage leads 1.5 m long Q 2 crocodile clips Q 2 x 1.5 V LR06 batteries ACCESSORIES / REPLACEMENT PARTS Q Standard PVC leads with 4 mm straight male plugs ______P01295288Z Q See all the accessories on page 144 SPECIFICATIONS L261 L481 Number of channels 1 Input connection 2 flush-mounted banana sockets Current range 0 to 600 VAC/DC -850 VDC to +850 VDC Accuracy (50/60 Hz) 0 to 5 V: not specified 5 to 50 V: ± (0.5 % R + 1 V) 50 to 600 V: 0 to 5 V: not specified 5 to 50 V: ± (0.5 % R + 1 V) 50 to 850 V: Resolution 0.1 V Sampling rate 64 samples per period 8 samples per second Storage interval Programmable from 125 ms to 1 day Storage modes Start/stop, FIFO, XRM™ extended measurement mode and recording on alarms Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 125 x 70 x 32 mm Weight (with batteries) 180 g Electrical safety IEC 61010-1, 600 V CAT III, 300 V CAT IV, Pollution degree 2 Casing UL94-V0 Vibration IEC 60068-2-6 (1.5 mm, 10 to 55 Hz) Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C ADDITIONAL INFO Q Automatic report generation
CHOOSE YOUR PHYSICAL MEASUREMENT LOGGER ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 136 L452 page 137 L642 page 138 Number of inputs 22 Process 4-20 mA QQ 0-10 V Q Temperature Q Programmable storage interval 5 s to 1 day 125 ms to 1 day
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 137 L452 Ref. : P01157201 STRENGTHS Q Process data logger with display Q 2 measurement channels Q Events counter Q Dry contact closure Q Detection of logic levels Q 1 adapter and 1 μUSB power cable Q 1 CD-ROM containing the Datalogger Transfer software ADDITIONAL INFO Q To simplify its use, the L452 is equipped with a magnetized rear panel. You can also use the Multifix system or a wall mount. ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS L452 Measurement range Resolution Accuracy (% reading) Sampling Current DC 4 to 20 mA 0.01 mA 0.05 mA (0.25 %) 5 samples/s Voltage DC 5 samples/s± 1 V ± 1 mV ± 1 mV (0,5 %) ± 10 V ± 10 mV ± 10 mV (0,5 %) Impulsion -1 m s- - Digital -1 m s 1 s (for recording for 1 month max.) Pulse voltage 3.3 V (with 1,000,000 Ω pull-up) Battery life Acquisition 200 ms, display on: 18 days Acquisition 200 ms, display off: 36 days Acquisition 1 min, display off: 270 days Power supply 110 to 240 V (50/60 Hz) – External: via USB connector Internal: 2.4 V rechargeable NiMH batteries (2 x 1.2 V) Storage modes Start/Stop (stop when memory full or when campaign end date is reached) Control Local mode (multi-directional keypad on front panel) Remote mode (control via PC) Recording duration 10 minutes to 1 year, configurable Examples 2 channels @ 200 ms: 19 days 2 channels @ 1 min: > 1 year (theoretically) Acquisition interval 200 ms to 1 hour Communication Bluetooth 2.1, Class 1, USB 2.0 Dimensions 32.4 x 65.5 x 125 mm (137.5 mm with screw connector) Weight 206 g Display LCD 128 x 64 pixels Measurement terminal strip 6 screw terminals Operating temperature 0 to 50 °C Protection IP42 (terminal block IP20) Electrical protection IEC 61010-1 Ed. 3 and IEC 61010-2-030 Ed. 1
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 138 50 V CAT III L642 Ref. : P01157050 STRENGTHS Q Monitoring of processes, heating systems and air-conditioning Q 2 input channels for thermocouple (J, K, T, N, E, R, S) Q Storage interval programmable from 1 every 5 seconds up to 1 per day Q Choice of 4 recording modes Q Up to 240,000 measurements saved in non-volatile memory Q L642 delivered with: Q 1 USB cable 2 m long, type A to mini-B 5-pin Q PC communication software Q 2 x 1.5 V LR06 batteries ADDITIONAL INFO Q Automatic report generation ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 144 SPECIFICATIONS L642 Number of channels 2 Input connection 2 miniature thermocouple connectors Measurement range °C (°F) j -210 to +1,200 (-346 to +2,192) k -200 to +1,372 (-328 to +2,501) t -250 to +400 (-418 to +752) n -200 to +1,300 (-328 to +2,372) E -150 to +950 (-238 to +1,742) R 0 to 1,767 (32 to 3,212) S 0 to 1,767 (32 to 3,212) Resolution 0.1 °C/F < 1,000 °C/F; 1 ° ≥ 1,000 °C/F Accuracy (50/60 Hz) 0.1 % to 0.2 % + 0.6 ° at 1 ° depending on thermocouple range and type Sampling rate 8 samples acquired at the storage interval Storage interval Programmable from 5 s to 1 day Storage modes Start-end, FIFO, XRM™ extended recording mode and recording on alarms Recording duration 15 minutes to 8 weeks, programmable using DataView® Data storage 240,000 measurements (512 kB). The recorded data are stored in non-volatile memory, even if the battery is low or absent Communication Optically-isolated USB 2.0 Power supply 2 x 1.5 V LR06 batteries Battery life 100 hours to > 45 days (depending on recording interval/duration) Mechanical specifications Dimensions 125 x 70 x 32 mm Weight (with batteries) 200 g Casing UL94-V0 Vibration IEC 60068-2-6 (1,5 mm, 10 to 55 Hz) Shocks IEC 60068-2-27 (30 G) Falls IEC 60068-2-32 (1 m) Environment Operating temperature -10 to +50 °C Storage temperature -20 to +60 °C
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 139 FTV 100 page 140 FTV 200 page 141 Solar power installation tester Q Solar panel tester Q DC voltage measurement QQ DC current measurement QQ AC voltage measurement Q AC current measurement Q Temperature measurement QQ Insolation measurement QQ Calculation of the installation's overall efficiency Q Calculation of inverter efficiency Q I / V curve in Standard Test Conditions Q Library of panels Q Report software QQ CHOOSE YOUR SOLAR POWER ANALYSER
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 140 1000 V CAT III 600 V CAT IV IP FTV 100 Ref. : P01160700 STRENGTHS Q Calculation of solar power installation efficiency Q Testing of solar power installation energy efficiency Q Electrical power survey Q Calculation of DC/AC inverter efficiency Q Simultaneous measurements on 1, 2 or 3 rows of panels installed in parallel Q FTV100 with 1 DC input plus A PAC10-FTV DC current clamp and
3 MN-FTV AC clamps delivered with:
Q 1 pyranometer for insolation with 5 m cable Q 1 Pt100 sensor for environment temperature with 3 m cable Q 1 Pt100 sensor for panel temperature with 3 m cable Q 3 AC current clamps (MN-FTV) with 3 m cable Q 1 DC current clamp (PAC10-FTV) with 3 m cable Q 4 x 3 m leads with test probes Q 1 rechargeable battery with mains adapter Q Data processing software Q 1 bag Q 1 certificate of conformity ADDITIONAL INFO Q Particularly easy to read, even in direct sunlight, thanks to the anti- reflective treatment Q The FTV 100 is also available in a version with 3 DC inputs plus 3 PAC10-FTV DC current clamps and 3 MN-FTV AC clamps __ P01160720 ACCESSORIES / REPLACEMENT PARTS Q 3 -DC-input installation measurement kit comprising:
2 PAC current clamps (PAC10-FTV) with 3 m cable,
2 sets of leads with test probes (3 m) Q GREENTEST FTV100 REMOTE unit comprising: 4 x 1.5 V LR6 batteries, 2 x RS232 M/M connectors for soldering, 1 mounting strap Q See all the accessories on page 144 SPECIFICATIONS FTV 100 Display Large 5.7” extra-bright colour digital LCD screen (320 x 240) with anti-reflective treatment Inputs Functions Range Accuracy Pyranometer Solar irradiance measurement 0 to 2,000 W/m2 ± 2 % Environmental temperature Measurement with Pt100 sensor Solar panel temperature Measurement with Pt100 sensor DC voltage 1 to 3 inputs 1,000 VDC ± 1 % DC current 1 to 3 inputs 1,400 ADC ± 1 % AC voltage 1 to 3 inputs 600 VAC ± 1 % AC current 1 to 3 inputs 3,000 AAC ± 1 % Functions Calculation functions Efficiency of solar panels with compensation of the modules’ temperature coefficient Efficiency of DC/AC conversion by the inverter Data logger Up to 10 instrument configurations pre-recorded in memory (measurements and results) Specifications Communication RS232 (remote unit) + USB (PC) Internal power supply Built-in rechargeable Li-Ion battery (4.5 Ah) Battery life 8 hours External power supply 230 Vac - 50 Hz external power supply Protection IP67 closed / IP54 open Dimensions / weight 360 x 304 x 194 mm / 3 kg Electrical safety IEC 61010-1 - 600 V CAT IV / 1 000 V CAT III
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 141 600 V CAT IV IP EN 60891 FTV 200 Ref. : P01160745 STRENGTHS Q Solar panel testing Q I-V curves of all types of solar panels Q Excellent display resolution: 500 measurement counts per curve with zoom Q Measurement of temperature, solar irradiance, peak power, Voc, Isc, etc. Q The specifications of thousands of types of solar panels are referenced in the integrated library ADDITIONAL INFO Q The FTV 200 is also available in a complete version delivered with 1 professional pyranometer and a Pt100 sensor Q FTV 200 delivered with: Q 1 bag Q 1 set of cables 3 m long Q 1 set of MC4 adapters (red/black) Q 1 MC4/banana Ø 4 mm adapter Q 1 magnetic stylus for touch screen Q 1 USB key Q 1 mains adapter Q 1 set of flexible test probes Q PC software Q 1 certificate of conformity ACCESSOIRES / RECHANGES Q See all the accessories on page 144 SPECIFICATIONS FTV 200 Screen 4.3” colour graphical LCD touch screen Library 10,000 curves (with panel reference values / manufacturer) Functions Voltage DC 10 to 1,000 V Current DC 0.1 to 10 A Power 10 W to 10 kW Radiation By pyranometer / 0 to 2,000 W/m2 Temperature by Pt100 - 20°C to +100°C I-V graph Graphic display of voltage/current measurement per panel or string MPP graph Graphic display of maximum power point (MPP) General specifications Communication USB 2.0 Power supply / battery life Mains or rechargeable Li-Ion battery pack / 12 hours on battery Safety IEC 61010, CAT III 600 V Operating temperature -5°C to +40°C Dimensions/weight 270 x 250 x 130 mm / 2.5 kg
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 142 DATAVIEW® Ref. : P01102095 FUNCTIONS Q Configuration of all the functions of instruments connected to a PC or via Bluetooth® Q Recovery of recorded measurement data Q Backup of measurement files Q Opening of saved files Q Processing and report creation (EN50160) Q Export into an Excel spreadsheet Q Export in .pdf format Q Database management Q Windows Vista & Windows 7/8/10 (32/64 bit) Q 1 GB RAM for Windows Vista & Windows 7/8 (32 bit) Q 2 GB RAM for Windows Vista & Windows 7/8 (64 bit) Q 80 MB available hard-disk space (200 MB recommended) REQUIRED CONFIGURATION ADDITIONAL INFO Q The Dataview® software: Q Automatically recognizes the instrument connected when it is hooked up to the PC and opens the corresponding menu. Users then have direct access to its configuration and the data stored on it Q Equipped with a large number of predefined report templates for quick generation in accordance with the applicable standards. Users can also create their own templates to meet their needs and directly add their own comments DataView® modules PAT PAT 2 PEL TRANSFER DATALOGGER Associated products F407 C.A 8331 PEL 102 L 562 F607 C.A 8333 PEL 103 CL601 C.A 8220 C.A 8336 PEL 105 L101 C.A 8230 L102 L111 ML912 ML914 AL834 L261 L481 L452 L642 POWER ANALYZER TRANSFER 2 FOR C.A 8331 / C.A 8336 The PAT 2 module in DataView® offers additional functions: Q Configuration of alarms Q Configuration of transients Q Configuration of trend curves Q Real-time display Q Data recovery, backup and export Q Measurement campaign start after automatic configuration of the associated instrument. PAT PAT 2 PEL TRANSFER DATA LOGGER
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 143 PAT 2 MODULE Configuration of EN 50160 parametersPAT MODULE Display of data stored by an F407 clamp PEL TRANSFER MODULE Remote display of a vectorial representation DATA LOGGER MODULE Recording of 0 -10 V - 2 channels Measurement campaign reports 5HFRUGLQJ6WDUW'DWH 5HFRUGLQJ'XUDWLRQ PLQ V ,QVWUXPHQW,' 0RGHO&$)LUPZDUH+DUGZDUH5HY3/''DWDEDVH)LOH1DPH BB5HFRUGLQJB4XDOLVWDU3OXVB3:GYE ,QVWUXPHQW&RQILJXUDWLRQ &RQQHFWLRQ7\\SH 3KDVH:LUH 5HDFWLYHYDOXHV4 YDU FDOFXODWLRQ 6HSDUDWHG :LW KRXW+DUPRQLFV 3KDVH+DUPRQLF5DWLRV)XQGDPHQWDO9DOXHDVUHIHUHQF H I /RQJ7HUP)OLFNHU 3OW )L[HG:LQGRZ 7UDQVIRUPHU)DFWRU.4 ( 2SHUDWRU1DPH &KDXQRX[$UYLQ 6WHSKDQH785'$ UXHGH%DJDWHOOH 3/28(7)UDQFH 6LWH1DPH $7/$17,& 6$81,(50LNH UXH0DOEHUW3RFK 1$17(6)5$1&( &RPPHQWV 4XDOLVWDU3OXV BB5HFRUGLQJB4XDOLVWDU3OXVB3: &RYHUV KHHWRI YDUK 9$K V'LY PLQ V 1DPH 'DWH 7LPH 0D[ 8QLWV 'XUDWLRQ 8QLWV YDUK YDUK PLQ V PLQ V (S'& PLQ V YDUK YDUK PLQ V 9$K 9$K PLQ V 9DOXH (S'& YDUK 9$K YDUK YDUK YDUK 'DWH 7LPH 9DO 8QLWV YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK YDUK 4XDOLVWDU3OXV BB5HFRUGLQJB4XDOLVWDU3OXVB3 (QHUJ\\RI V'LY PLQ V 1DPH 'DWH 7LPH $YJ 0LQ 0D[ 8QLWV 'XUDWLRQ 8QLWV 9UPV PLQ V 9DOXH 9UPV 9UPV 'DWH 7LPH 9DO 0LQ 0D[ 8QLWV 4XDOLVWDU3OXV BB5HFRUGLQJB4XDOLVWDU3OXVB3: 9UPV RI
ACCESSORIES / REPLACEMENT PARTS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 144 MODEL MEASUREMENT RANGE CLAMPING Ø / LENGTH IEC 61010 REFERENCE MN93 500 mA to 200 AAC Ø 20 mm 600 V CAT III / 300 V CAT IV P01120425B MN 93A 5 mA to 100 AAC Ø 20 mm 600 V CAT III / 300 V CAT IV P01120434B MA193-250 MA193-350 MA196-350 100 mA to 10 kAAC Ø 70 mm / 250 mm Ø 100 mm / 350 mm Ø 100 mm / 350 mm
1000 V CAT III / 600 V CAT IV
PAC93 1 A to 1,000 AAC / 1 A to 1,300 ADC 1 x Ø 39 mm or 2 x Ø 25 mm 600 V CAT III / 300 V CAT IV P01120079B J93 50 A to 3,500 AAC /
50 A to 5,000 ADC Ø 72 mm 600 V CAT III / 1000 V CAT IV P01120110
A196A-610 100 mA to 10 kAAC Ø 140 mm / 450 mm Ø 190 mm / 610 mm 1000 V CAT III / 1000 V CAT IV P01120526B P01120554 A193-800 100 mA to 10 kAAC Ø 250 mm / 800 mm 1000 V CAT III / 600 V CAT IV P01120531B C193 1 A to 1,000 AAC Ø 52 mm 600 V CAT IV P01120323B E3N 50 mA to 10 AAC/DC 100 mA to 100 AAC/DC Ø 11.8 mm 600 V CAT III / 300 V CAT IV P01120043A DESCRIPTION REFERENCE Kit of 5 banana leads + 5 crocodile clips + 1 set of coloured rings P01295483 Kit of 4 banana leads + 4 crocodile clips + 1 set of coloured rings P01295476 1 set of coloured inserts and rings P01102080
5 A adapter unit P01101959
Reeling box - MultiFix magnetized casing P01102149 USB-A USB-B lead P01295293 Bag no. 22 P01298056 DataView® software P01102095 ESSAILEC casing P01102131 CURRENT SENSORSOTHER ACCESSORIES POWER AND ENERGY QUALITY ANALYSERS AND LOGGERS
ACCESSORIES / REPLACEMENT PARTS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 145 MODÈLE MEASUREMENT RANGES OUTPUT SIGNAL PHASE SHIFT* MAX. CONDUCTOR SIZE OUTPUT CONNECTION COMPATIBLE PRODUCTS REFERENCE AC VOLTAGE Ø CABLE BUSBAR E3N 100 mA to 10 A 1 to 100 A 100 mV/AAC 10 mV/AAC < 1.5 ° 11.8 mm – BNC lead L101 L102 L562 P01120043A MN 60 0.1 to 24 A 0.5 to 240 A 100 mV/AAC 10 mV/AAC < 2.5 ° 19.8 mm – BNC lead P01120409 PAC 12 0.2 to 40 A 0.5 to 400 A 10 mV/AAC 1 mV/AAC < 1.5 ° One cable: 30 mm Two: 24 mm Two 31,5 x 10 mm BNC lead P01120072 PAC 22 0.2 to 100 A 0.5 to 1,000 A 10 mV/AAC 1 mV/AAC < 1.5 ° One cable: 39 mm Two: 25 mm One 50 x 12 mm Two 50 x 5 mm BNC lead P01120073 C160 0.1 to 10 A 0.1 to 100 A 1 to 1,000 A 100 mV/AAC 10 mV/AAC 1 mV/AAC < 1 ° 52 mm 50 x 5 mm BNC lead P01120308 D38N 1 to 30 A 1 to 300 A 1 to 3,000 A 10 mV/AAC 1 mV/AAC 0,1 mV/AAC < 1 ° 64 mm 64 x 100 mm 50 x 135 mm BNC lead P01120057A MN11 0.5 to 240 A 1 mA/ AAC < 2.5 ° 19.8 mm – Wire cable with reinforced or double insulation 1.5 m long and terminated by 2 elbowed male banana safety plugs Ø 4 mm L111 P01120404 C103 0.1 to 1,200 A 1 mA/ AAC < 0.5 ° 52 mm 50 x 5 mm Wire cable with reinforced or double insulation 1.5 m long and terminated by 2 elbowed male banana safety plugs Ø 4 mm P01120303 *Maximum rated phase shift VOLTAGE OUTPUTCURRENT OUTPUT CURRENT SENSORS FOR LOGGERS (EXCLUDING PEL)
ACCESSORIES / REPLACEMENT PARTS ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 146 C.A 8331 / C.A 8333 / C.A 8336 Q PA30W mains power pack (C.A 8331-33-35-36) ________ P01102057 Q Set of 2 magnetized test probes (1 red / 1 black) ______ P01103058Z C.A 8435 C.A 8220 C.A 8220 / C.A 8230 Q Set of 2 magnetized test probes (1 red / 1 black) ______ P01103058Z THREE-PHASE POWER AND ENERGY QUALITY ANALYSER POWER AND ENERGY QUALITY ANALYSER F407, F607 Q Set of 2 magnetized test probes (1 red / 1 black) _______ P01103058Z POWER AND HARMONICS MULTIMETER CLAMP FTV 100 / FTV200 SOLAR POWER ANALYSER PEL 102 and PEL 103 Q Set of 2 magnetized test probes (1 red / 1 black) _______ P01103058Z PEL 105 Q Set of IP 67 banana leads 3 m long (x5) _____________ P01295479 Q Set of 2 magnetized test probes (1 red / 1 black) ______ P01103058Z POWER AND ENERGY LOGGERS
ENERGY QUALITY & INSTALLATION MONITORING 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 147 L261 and L481 Q Standard PVC leads with 4 mm straight male plugs _____ P01295288Z Q USB cable 2 m long, type A to mini-B 5-pin ___________ Contact us L562 Q Standard PVC leads with 4 mm straight male plugs _____ P01295288Z TRMS VOLTAGE/CURRENT LOGGER L111 Q Standard PVC leads with 4 mm straight male plugs _____ P01295288Z ML912 ML914 et AL 834 L101 and L102 CURRENT LOGGERS VOLTAGE LOGGERS L642 TEMPERATURE LOGGER L452 PROCESS DATA LOGGER FIND ALL OUR ACCESSORIES ON PAGE 230 FTV 100 Q 3-DC-input installation measurement kit: 2 sets of leads with test probes (3 m) Q GREENTEST FTV100 REMOTE unit: 4 x 1.5 V batteries,
2 RS232 M/M connectors for soldering,1 mounting strap _ P01160736
Q «Cable» communication kit: 1 series cable 15 m long, Q «Bluetooth» communication kit: 2 Bluetooth adapters (transmitter/receiver), 2 RS232 M/F and M/M series cables 20 cm long, adapter programming software __________ P01160738 FTV 200 SOLAR POWER ANALYSER ACCESSORIES / REPLACEMENT PARTS ENERGY QUALITY & INSTALLATION MONITORING
& ENVIRONMENTAL MEASUREMENTS Info and advice 150 Calibrators 154 Thermal cameras 157 Thermometers 164 Other physical & environmental measuring instruments 172 Accessories 188
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 150 TEMPERATURE MEASUREMENT Thermometers have always been essential instruments, used by all industrial companies for:
- Ambient temperature measurement.
- Control of the temperature in a cold room or climatic chamber.
- Temperature measurement on partitions.
- Verification of the hot spots in a an electrical cabinet.
- Verification of foodstuff freshness by inserting a probe in the heart of the product Chauvin Arnoux offers easy-to-use electronic thermometers which are rugged and accurate:
- Thermocouple thermometers.
- Resistive-probe thermometers.
- No-contact thermometers.
- Thermal cameras. THERMOCOUPLES The operating principle of thermocouples is based on the electromotive force created naturally between two conductor wires of different materials joined at the end (SEEBECK effect). This electromotive force depends on the temperature to which one of the two junctions is exposed. This temperature is measured as a voltage of a few millivolts. A thermocouple is therefore composed of two junctions (or welds) linking two different metals or alloys. One of the junctions, positioned at the point of measurement, is called the hot junction, while the other is called the cold junction and its known temperature serves as the reference. For two given materials or alloys, there is a relation between the electromotive force and the reference and measurement temperatures. This relation is usually expressed by a characteristic curve of sensitivity in mV/°C. RESISTIVE PROBES Some pure metals have a coefficient of resistivity which varies as a function of temperature in a reproducible way. The metals generally used are platinum and copper. Currently, the widest-used type is platinum, with a resistance of 100 Ω at 0 °C. OPTICAL OR NO-CONTACT MEASUREMENTS All bodies emit electromagnetic radiation whose spectrum has an energy distribution which is a function of temperature. This measurement system offers quick temperature testing on parts which are current-carrying, moving or difficult to access. It can also be used for measurements of very high temperatures or on poor heat conductors such as ceramics or synthetic materials. CHOOSING THE RIGHT TEMPERATURE MEASUREMENT SYSTEM Three types of measurement are used to measure temperature:
- Measurement by penetration (semi-solids, pasty samples, etc.) and by immersion (liquids).
- Ambient measurement (air, gas).
- Surface measurement (solid bodies). For the latter type, users can choose a system with or without contact, depending on the application involved. The type of application will determine the instrument and the probe chosen. In general, thermocouples offer quick response times and wide measurement ranges. Sensors with resistive probes are usually slower, but they are also more accurate. The sensor selection criteria will depend on:
- the milieu and the operating environment.
- the temperature range.
- the required accuracy.
- the response time.
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 151 INFRARED THERMOGRAPHY Infrared thermography detection technology has become irreplaceable for ensuring safe conditions for industrial production. Infrared thermal imaging is a no-contact, real-time inspection method for production equipment subject to high voltages, powerful electric currents or high operating speeds. For this detection method, there is no need to cut off the current, shut down the machines or stop production. It can be used to troubleshoot any latent malfunctions in advance and thus prevent failures and avoid production incidents. Thermal imaging is an innovative technique for safe, reliable and quick “no-contact” assessment. A thermal camera does not measure temperatures but radiation fluxes. Once the operator has adjusted certain parameters, the camera calculates the temperatures of the target. It then provides the user with a map of the temperatures, called a thermogram: each temperature is represented by a different colour. ELECTRICAL MAINTENANCE The purpose of this sort of inspection is to detect any overheating in working electrical systems due to various causes: poor connections, overloads, phase unbalance, faulty contacts, etc. This helps to prevent and avoid costly equipment damage, production shutdowns, operating losses, fires, etc. The aim is to help with decision-making for corrective action, to prevent incidents, to anticipate any works which might be necessary and to facilitate electrical installation maintenance (time saving and safety). MECHANICAL MAINTENANCE Moving mechanical parts heat up quite normally due to friction. Infrared thermography reveals abnormal overheating due to wear, misalignment, lubrication problems, etc. It is used to complement vibratory analysis, which is much more time-consuming to set up. A single image gives a full health report on the electric motor, its power supply (cables), the bearings and, if necessary, the alignment. BUILDING THERMICS These applications of infrared thermography concern architects, heating and sanitary installers, heating operators, electricians, property companies, property experts, owners and insurers. With a n infrared ca mera, it is easy to view the distribution of heat on the front of a building and it also possible to precisely locate heat losses due to faulty insulation. This helps to produce a thermal survey of the building.
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 152 INDOOR AIR QUALITY Whether in places open to the public (transport, government offices, schools or hospitals), workplaces or private areas, our lifestyles mean we spend most of our time indoors. Human activities and products used in construction, decoration and furniture (paint, floor and wall coverings, varnishes, etc.) are all sources of contamination emitting substances into the air. The issue of indoor air quality has only been raised recently, but it is a major concern because it affects everyone. CARBON DIOXIDE (CO2) Carbon dioxide is a colourless, odourless gas produced by the com bustion of ca rbon-ba sed m ateri a l s s uc h a s wood, oil, coal and their derivatives. It is also produced by humans’ and animals’ respiration. Plants, however, actually extract CO 2 from the air during photosynthesis, thus contributing to the natural balance. Nevertheless, the level of CO2 in outdoor air is increasing. This gradual increase began with the industrial revolution and the growing use of fossil fuels. WHY MEASURE IT? Indoors, CO2 is representative of a level of confinement indicating an accumulation of pollutants in the premises and insufficient air renewal. Links have been found between poor ventilation, leading to high levels of CO 2, and reduced performance by children in tests involving logic, reading and calculations. Concentrations above 1,000 ppm already cause sleepiness, difficulty in concentrating and even headaches.
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 153 THRESHOLD VALUES I n v o l u m e t e r m s , t h e p r o p o r t i o n o f C O2 in the air is 0.0375%, or 375 ppmv (parts per million by volume). In urban environments, it may be as high as 500 ppm.
- 500 to 1,000 ppm - Indoor air quality: Good
- 1,000 ppm - Certain studies have shown an increase in asthma-related symptoms among children on average over a school day
- 1,500 to 2,500 ppm - Indoor air quality: Poor (1,500 ppm is the regulatory limit usually specified, particularly for educational premises in the United Kingdom, Germany and Austria)
- 2,500 to 5,000 ppm - Symptoms: headache, fatigue and loss of concentration
- 5,000 ppm - Average concentration over 8 hours - Occupational Exposure Limit in France and elsewhere SENSOR POSITIONING AND RECOMMENDATIONS The measuring instrument should preferably be positioned between 50 cm and 2 m from the ground. In practice, it should be set up in a safe place with access to a power socket if necessary. The instrument should be kept at least 50 cm away from any intense heat sources (heating) and should be kept out of direct sunlight. The instrument must not be placed in the direct flow of air from outside (windows) or close to the entrance. The CO 2 level varies during the day, depending on how many people are present, the activities involved and the efficiency of the air renewal system; for these reasons, functions for recording and for indicating any threshold overruns are crucial. CO 2 and other gases absorb IR radiation in a “specific” way.
- 1 source emits an IR signal in a predefined cavity
- The CO 2 absorbs part of the light in the near-IR spectrum, thus reducing the intensity of the signal
- The IR detector measures the intensity of the signal received at the absorption wavelength of carbon dioxide. The Beer-Lambert Law establishes the relationship between the signal intensity and the gas concentration. MEASUREMENT PRINCIPLE The method used by the C.A 1510 to measure CO2 levels is an NDIR (Non-Dispersive InfraRed) method. IR source Measurement cell Detector CO2
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 154 C.A 1621 page 155 C.A 1623 page 155 C.A 1631 page 156 Measurement / Simulation J, K, T, E, R, S, B and N thermocouples Q Resistive probes Pt10, Pt50, Pt100, Pt200, Pt500, Pt1000 Q 4-20 mA Q 0-10 V Q Voltage Up to 100 mV QQ Up to 20 V Q Current Up to 24 mA Q Resistance 0.00 to 3,200.0 Q
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 155 °C °F C.A 1621 - C.A 1623 Ref. : P01654621 P01654623 STRENGTHS Q Large screen for easier reading Q Instrument calibration without removing the sensors Q Comfortable handling due to its dimensions (205x97x45 mm) and weight (472 g) C.A 1621: thermocouple-probe temperature calibrator capable of measuring and simulating: Q up to 8 types of thermocouple: J, K, T, E, R, S, B and N Q a voltage in mV C.A 1623: resistive-probe temperature calibrator capable of measuring and simulating: Q up to 7 types of resistive probes: Pt 10, Pt 50, Pt 100, Pt 200, Pt 500, Pt 1000, Pt 100(JIS) Q a resistance Q 6 x 1.5 V LR06 batteries Q C.A 1621 delivered with 2 additional thermocouple adapters Q C.A 1623 delivered with 2 additional test leads and 2 additional crocodile clips ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1621 Input/output range Resolution Accuracy -10 mV … 100 mV 0.01 mV ± 0.025 % + 2 counts Function Range Resolution Accuracy Ref. junction error C.A 1623 Range 4-wire measurement accuracy ± Ω Simulation accuracy ± Ω Acceptable excitation mA 0.1 0.5 … 3.0 1,500.0 Ω … 3,200.0 Ω 1 1 0.05 … 0.42 Mode Range Accuracy in °C Excitation admissible mA4-wire input 2-wire / 3-wire input Output Pt10 385 -200 … +800 °C 0.1 … 3.0 0.1 … 3.0 Pt200 385 -200 … +250 °C 0.2 0.3 1.6 0.2 0.8 0.1 … 3.0 Pt500 385 +250 … +630 °C 0.8 0.3 0.3 0.4 0.05 … 3.0 Pt1000 385 -200 … +500 °C 1.6 0.4 0.5 0.2 0.2 0.1 … 3.0 ADDITIONAL INFO Q Power supply via optional mains lead: Q Input: 100 V/240 V - 50/60 Hz – 1.8 A Q Output: 12 VDC, 2 A max Q Battery-powered (6 x 1.5 V supplied) or via mains lead (option)
PROCESS SIGNAL CALIBRATORS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 156 C.A 1631 Ref. : P01654402 STRENGTHS Voltage/current process signal calibrator used to measure or supply: Q a 0 -24 mA DC current loop Q a 0 - 20 V DC voltage Q 6 x 1.5 V LR06 batteries Q 2 test leads Q 2 crocodile clips Q 2 test probes ADDITIONAL INFO Q Power supply via optional mains lead: Q Input: 100 V/240 V - 50/60 Hz – 1.8 A Q Output: 12 Vdc, 2 A max Q Powered by batteries (6 x 1.5 V supplied) or via mains lead (option) SPECIFICATIONS C.A 1631 Calibre Resolution Accuracy ± (% of reading + counts) 100 mV 0.01 mV 0.02 % + 3 20 V 0.001 V 0.02 % + 3 Input impedance: 2 MΩ (rated value), < 100 pF Protection against overvoltages: 30 V - Current supplied at 20 V: 1 mA Calibre Resolution Accuracy ± (% of reading + counts) 24 mA 0.001 mA 0.015 % + 3 Protection against overloads: 125 mA 250 V quick-response fuse Percentage display: 0 % = 4 mA 100 % = 20 mA Source mode: 1,000 Ω load at 20 mA for a battery voltage ≥ 6.8 V (700 Ω at 20 mA for a battery voltage between 5.8 and 6.8 V) Simulation mode: external loop voltage condition: 24 V (rated value), 30 V maximum, 12 V minimum. Loop voltage power supply: 24 V ± 10 % ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188
CHOOSE YOUR THERMAL CAMERA PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 157 C.A 1950 page 158 C.A 1954 page 159 C.A 1886 page 160 C.A 1888 page 161 Detectors 80 x 80 Q 160 x 120 QQ 384 x 288 Q Thermal sensitivity (N.E.T.D) 0.08°C @ 30°C QQQ 0.05°C @ 30°C Q Temperature range -20°C to +250°C QQ -20°C to +600°C QQ 1,000°C / 1,500°C (option) QQ Display mode Thermal image QQQQ Real image and merge Merge via software Merge via software QQ Display 2.8 inches 2.8 inches 3.5 inches 3.5 inches Analysis functions Manual cursor 1133 Min / Max on area QQQQ Average on area QQQ Isotherm QQQQ Temperature profile QQQQ Temperature differential QQ Alarms QQ Correction parameters Emissivity, environmental temp., relative humidity, distance QQQQ Others CNPP Approval QQ Wide-angle or telephoto lenses available as options QQ Analysis and report creation software CAm Report CAm Report RayCAm Report RayCAm Report Available mid-2018
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 158 SPECIFICATIONS IP 80x BMP C.A 1950 Ref. : P01651901 STRENGTHS Q 13-hour battery life and startup in only 3 seconds Q Withstands falls of up to 2 m without interrupting operation Q Focus-free with 20° x 20° field of view Q Voice annotation for recording your comments directly on the image (earphone supplied) Q Connectivity with current clamps and multimeters Q C.A 1950 delivered in site-proof hard case with: Q 4 x NiMH batteries Q 1 battery charger Q 1 x 2 GB micro SD HD card Q 1 USB cable Q 1 Bluetooth® earphone Q 1 CD-ROM containing the CAmReport software Q 1 measurement report ADDITIONAL INFO Q Recording of thermal image and real image simultaneously. Image merge function available via the CAmReport software supplied Q Large number of measurement tools: manual cursor, automatic detection, temperature profile, etc. Q Built-in brightness sensor C.A 1950 Detector 80 x 80 Type UFPA microbolometer, 8 ~14 μm Frequency 9 Hz Sensitivity (N.E.T.D) 80 mK @ 30 °C (0.08 °C @ 30 °C) Temperature measurement Temperature range -20 °C to +250 °C Accuracy ±2 °C or ±2 % of reading Imaging performance (thermal image) Field of view 20° x 20° IFOV (spatial resolution) 4.4 mrad Focus Fixed Minimum focal distance 40 cm Real image Yes (320 x 240 pixels) Display mode Thermal image, real image with automatic parallax compensation. Image merge available with PC software Analysis functions Measurement tools 1 manual cursor + 1 automatic detection + Min Max on adjustable area + Temperature profile + Isotherm Parameter settings Emissivity, environmental temperature, distance, relative humidity Voice comments Yes by Bluetooth® (earphone supplied) Connectivity F407, F607, MTX 3292 and MTX 3293 clamps Data storage On 2 GB removable micro SD card (approx. 4,000 images), up to 32 GB Image format .bmp (thermal and real images recorded simultaneously) Image presentation Adjustment Automatic or manual adjustment of palette min/max Image hold Animated or fixed image Image display Multi-palette Screen 2.8 inches Power supply Type Rechargeable NiMH batteries with low self-discharge Recharging External (charger supplied) Battery life 13 hrs 30 min (typical) / 50 % brightness, Bluetooth® off Environmental specifications Operating temperature -15 °C to +50 °C (-4 °F to +122 °F) Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) Humidity 10 % to 95 % Compliance with standards EN 61326-1 : 2006 / EN 61010-1 Ed. 2 Fall resistance 2 metres on all surfaces Shock resistance 25 G Vibration resistance 2 G Physical specifications Weight /dimensions 700 g with rechargeable batteries / 225 x 125 x 83 Ingress protection IP 54 Interfaces - USB link and Mass Storage: the product is then recognized as a USB key for easy image transfer - Bluetooth for connectivity with earphone (voice comments) and Chauvin Arnoux® Metrix® measuring instruments (F407, F607, MTX 3292, MTX 3293) Tripod mounting Yes, ¼’’ insert on camera General specifications Report creation software Supplied as standard with automatic report generation in .pdf or .docx (Word) format / Compatible with W7, W8, 32 and
64 Bits
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 159 SPECIFICATIONS IP 160x 120 PNG C.A 1954 Réf. : P01651904 STRENGTHS Q Unprecedented! Battery life of up to 9 hrs in continuous use Q Withstands falls from up to 2 m without interrupting operation Q Focus-free with 38° x 28° field of view Q Recovery of data from other measuring instruments (current, humidity, dew point, etc.) Q Practical: voice recording, user-enhanceable emissivity table, organization of folders by site Q C.A 1954 delivered in set-proof case with: Q 4 NiMH batteries Q 1 battery charger Q 1 x 2 GB HD micro SD card Q 1 USB cable Q 1 Bluetooth earpiece Q 1 CD-ROM containing the CAmReport software Q 1 measurement report ADDITIONAL INFO Q Simultaneous recording of thermal image and real image. Image merging possible with the CAmReport software supplied Q Large number of measurement tools: manual cursor, automatic detection, temperature profile, etc. Q Built-in ambient light sensor C.A 1954 Detector 160 x 120 Type UFPA microbolometer, 8 ~14 μm Frequency 9 Hz Sensitivity (N.E.T.D) 80 mK @ 30 °C (0.08 °C @ 30 °C) Temperature measurement Temperature range -20 °C to +250 °C Accuracy ±2 °C or ±2 % of reading Imaging performance (thermal image) Field of view 38° x 28° IFOV (spatial resolution) 4.1 mrad Focus Fixed Minimum focal distance 30 cm Real image Yes (320 x 240 pixels) Display mode Thermal image, real image with automatic parallax compensation. Image merging available with PC software Analytical functions Measuring tools 1 manual cursor + 1 automatic detection + Min Max Avg on adjustable area + temperature profile + isotherm Parameter settings Emissivity, environmental temperature, distance, relative humidity Voice comments Oui par Bluetooth (oreillette fournie) Connectivity C.A 1821/22/23, C.A 1246, C.A 1227, F407, F607, MTX 3292, MTX 3293 Storage Sur carte micro SD 2 Go (environ 4000 images) amovible jusque 32 Go Image format .png (thermal and real images saved simultaneously) Laser pointer Yes Image display Settings Automatic or manual adjustment of the min max for the palette Freezing of image Animated or fixed image Display of the images Multi-palette Screen 2.8 inches Power supply Type NiMH rechargeable batteries with low self-discharge Recharging method External (charger supplied) Battery life 9 hrs (typical) / 50 % brightness and Bluetooth deactivated Environmental specifications Operating temperature -15 °C to +50 °C (-4 °F to +122 °F) Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) Humidity 10 % to 95 % Compliance EN 61326-1: 2006 / EN 61010-1 Ed. 2 Resistance to falls 2 metres on all surfaces Shock resistance 25 G Vibration resistance 2 G Physical specifications Weight 700 g with rechargeable batteries Dimensions 225 x 125 x 83 mm Ingress protection IP 54 Interfaces - USB link and Mass Storage function. - Bluetooth for connectivity with earpiece (C.A 1821/22/23, C.A 1246, C.A 1227, F407, F607, MTX 3292, MTX 3293) Mounting on tripod Yes, ¼’’ insert on the camera General specifications Report generation software Supplied as standard with automatic report generation (.pdf / .docx) Compatible with W7, W8, W10, 32 and
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 160 C.A 1886 Ref. : P01651260 STRENGTHS Q 160 x 120 matrix Q Sensitivity: 0.08 °C at 30 °C Q Temperature up to 600 °C as standard Q Large, multi-directional 3.5” screen for easier reading Q MixVision function which links a thermogram to a real image Q C.A 1886 delivered in a case with: Q 1 battery charger Q 2 batteries Q 1 x 2 GB mini SD card Q 1 SD card reader Q 1 video cable Q 1 CD-ROM containing the RayCAm Report software Q 1 measurement report ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1886 Detector 160 x 120 Type UFPA microbolometer, 8-14 microns Sensitivity (NETD) 0.08 °C @ 30 °C Temperature -20 °C to +600 °C as standard Up to 1,500 °C as an option Accuracy ±2 °C or ±2 % Optics Field of view: 20° x 15°, IFOV: 2.2 mrad Min. focal distance: 10 cm “MixVision” mode Merge function with adjustment of percentage of thermal image in real image from 0 to 100% Image size 640 x 480 pixels Adjustment Emissivity, environmental temperature, distance, humidity Measurement tools 3 manual cursors + 1 auto. Max/Min/Avg detection on area, isotherm, temperature differential, temperature profile Data storage 1,000 images (radiometric format) in 250 folders + 2 GB on mini-SD card Power supply Battery life: 3 hrs (continuous use) Recharging via external charger IP 160x 120 Attestation délivrée selon un essai unique Disponible sur www.cnpp.com N° 2010-0020 ADDITIONAL INFO Q Refresh rate: Q 50 Hz in the EU Q 9 Hz outside the EU
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 161 C.A 1888 Ref. : P01651270 STRENGTHS Q 384 x 288 matrix Q Sensitivity: 0.05 °C @ 30 °C Q Temperature up to 600 °C as standard Q Large multi-directional 3.5” screen for easier reading Q MixVision which links a thermogram to a real image ADDITIONAL INFO Q The C.A 1888 thermal camera is also available in other configurations: Q C.A 1888 with 1,000 °C high-temperature option ________ P01651271 Q C.A 1888 with 1,500 °C high-temperature option ________ P01651272 Q RayCAm Report software supplied for area analysis (polygons or polylines) and studying the temperature distribution on a histogram Q C.A 1888 delivered in a case with: Q 1 battery charger Q 2 batteries Q 1 x 2 GB mini SD card Q 1 SD card reader Q 1 video cable Q 1 CD-ROM containing the RayCAm Report software Q 1 measurement report ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1888 Detector* 384 x 288 Type UFPA microbolometer, 8-14 microns Sensitivity (NETD) 0.05 °C @ 30 °C Temperature -20 °C to +600 °C as standard Up to 1,500 °C as an option Accuracy ±2 °C or ±2 % Optics Field of view: 24° x 18°, IFOV: 101 mrad Min. focal distance: 10 cm “MixVision” mode Merge function with adjustment of percentage of thermal image in real image from 0 to 100% Image size 640 x 480 pixels Adjustment Emissivity, environmental temperature, distance, humidity Measurement tools 3 manual cursors + 1 auto. Max/Min/Avg detection on area, isotherm, temperature differential, temperature profile Mémoire Data storage 1,000 images (radiometric format) in 250 folders + 2 GB on mini-SD card Power supply Battery life: 3 hrs (continuous use) Recharging via external charger LENSES FOR C.A 1888 Lens IFOV spatial resolution 0.1 m 0.3 m 0.5 m 1 m 2 m 6 m 10 m 30 m 100 m 12°× 9° Telephoto lens 0.55 mrad 24°× 18° Standard lens 1.1 mrad 48°× 36° Wide-angle lens 2.2 mrad IP 384x 288 Attestation délivrée selon un essai unique Disponible sur www.cnpp.com N° 2010-0020 HFOV : (metres) Horizontal field of view VFOV : (metres) Vertical field of view IFOV : Spatial resolution HFOV VFOV IFOV *Refresh rate: 50 Hz in the EU / 9 Hz outside the EU
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 162 PDFC.A 1950 C.A 1954 CAmReport STRENGTHS Q Dedicated to the C.A 1950 and C.A 1954 thermal cameras Q Supplied as standard at no additional cost Q Complete, with all the functions needed for reliable analysis of the measurement results Q Automatic creation of analytical reports which can be exported in Word or pdf format. AVAILABLE LANGUAGES Q French, English, German, Spanish, Italian , Dutch, Polish, Romanian, Czech, simplified Chinese, Portuguese, Swedish, Finnish PRECISE ANALYSIS TOOLS Q Cursors (automatic display of the temperature at the selected point) Q Thermal profile (automatic display of the Min/Max/Avg temperatures of the line) Q A square or circle for area analysis Q Polygons and polylines for more precise analysis of certain areas in the thermogram Q Results tables quickly and automatically display all the information Q Recovery of the voice comments or related measurements Q Automatic merging of the thermal and real images recorded simultaneously Q Automatic report creation for export in .pdf or .docx format REQUIRED CONFIGURATION WINDOWS XP : Q SP3 minimum Q 850 MB RAM for 32 bit Q 2 GB for 64 bit Q NET Framework 4.0 minimum Q Monitor resolution: super VGA (800 x 600) or higher WINDOWS VISTA / 7 / 8 / 10 : Q SP1 minimum Q 850 MB RAM for 32 bit Q 2 GB for 64 bit Q NET Framework 4.0 minimum
THERMOGRAM ANALYSIS SOFTWARE PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 163 C.A 1886 C.A 1888 TXT CSV RayCAm Report STRENGTHS Q Specially developed for the C.A 1886 and C.A 1888 thermal cameras Q Supplied as standard at no additional cost Q Complete, with all the functions needed for reliable analysis of the measurement results Q Creation of analysis reports exportable in Word or PDF format Q Very simple user interface AVAILABLE LANGUAGES Q French, English, German, Spanish, Italian. PRECISE ANALYSIS TOOLS Q Cursors (automatic display of the temperature at the selected point) Q Thermal profile (automatic display of the Min/Max/Avg temperatures of the line) Q A square or circle for area analysis Q Polygons and polylines for more precise analysis of certain areas in the thermogram Q Results tables quickly and automatically display all the information Q The “Max” function automatically indicates the hot point in the whole thermogram or in a predefined area for analysis Q A histogram for studying the temperature distribution according to several intervals Q Display of a value label next to the measurement tool Q Assignment of a different emissivity from that of the rest of the thermogram Q Automatic merging of the thermal and real images recorded simultaneously Q Automatic customizable report generation for export in .pdf or .docx format REQUIRED CONFIGURATION WINDOWS XP : Q SP2 minimum Q 512 MB RAM minimum Q CPU 700 Hz minimum Q NET Framework 2.0 minimum Q Monitor resolution: 1,024 x 768 minimum WINDOWS VISTA / 7 / 8 / 10 : Q SP1 minimum Q 1 GB RAM minimum Q CPU 1 GHz minimum Q NET Framework 2.0 minimum Q Monitor resolution: 1,024 x 768 minimum
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 164 C.A 1871 C.A 871 C.A 879 C.A 1864 C.A 1866 C.A 876 C.A 1821 C.A 1822 C.A 1823 TK 2000 TK 2002 page 167 page 165 page 165 page 166 page 166 page 168 page 170 page 170 page 171 page 169 page 169 Measurement by infrared QQQQQQ Field of view 8/1 QQ 10/1 Q 12/1 Q 30/1 Q 50/1 Q Emissivity Fixed: 0.95 QQQ Variable: 0.1 to 1 QQQ Laser sighting QQQQQQ Contact measurement K sensor - 1 input Q J, K, T, N, E, R, S J, K, T, N, E, R, S KK K sensor - 2 inputs J, K, T, N, E, R, S K Pt100 sensor Pt100 Pt1000 General functions HOLD QQQQQQQQQQQ Max QQQQQQ Min QQQQQQ Avg QQ via Data Logger Transfer via Data Logger Transfer via Data Logger Transfer Alarm QQQQQQ Choice of units QQQQQQQQQ Backlighting QQQQQQQQQ
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 165 °C °F IR C.A 871 - C.A 879 Ref. : P01651302Z P01651805Z STRENGTHS Q Small and easy to handle Q Simple to use Q Ideal for everyone Q Ergonomics specially designed for comfortable handling Q Laser sighting for precise targeting of measuring area Q C.A 871 and C.A 879 delivered with: Q 1 bag Q 1 x 9 V LR14 battery ACCESSORIES / REPLACEMENT PARTS SPECIFICATIONS C.A 871 C.A 879 Field of view 8/1 12/1 Emissivity Fixed: 0.95 Measurement range - 40 °C to + 538 °C - 50 °C to + 550 °C Resolution 0.1 °C up to 100 °C 1 °C for > 100 °C Accuracy* ± 2.5 % ± 2 °C ±1.5 % ± 2 °C Functions Laser sighting Yes Continuous measurement Yes (continuous press on trigger) Hold Yes Measurement unit °C / °F Display 2,000 counts, backlighting Dimensions / weight 160 x 82 x 41.5 mm 180 g 230 x 100 x 56 mm 290 g *Depending on temperature measurement range. See User Manual for further details.
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 166 °C °F IR C.A 1864 - C.A 1866 Ref. : P01651813 P01651814 STRENGTHS Q Extended temperature range: measure up to 1,000 °C Q Use the variable emissivity to perform your inspections in accordance with reality Q High distance/spot ratio for better accuracy at long distances Q Set your alarm thresholds so that you are alerted every time there is an abnormal temperature! Q C.A 1864 and C.A 1866 delivered with: Q 1 bag Q 1 x 9 V LR14 battery ACCESSORIES / REPLACEMENT PARTS SPECIFICATIONS C.A 1864 C.A 1866 Distance/spot ratio 30/1 50/1 Emissivity 0.1 to 1 Measurement range - 50 °C to +1,000 °C Resolution 0.1 °C Accuracy - 50 °C to - 20 °C: ± 5 °C Functions Max., Min., Avg., DIFF, HOLD Alarms High and Low Measurement unit °C, °F Laser sighting Yes, Class II laser Display 20,000 counts, backlighting Dimensions / weight 230 x 100 x 56 mm / 290 g Distance / Spot ratio: explanatory diagram
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 167 C.A 1871 Ref. : P01651610Z STRENGTHS Q Infrared probe suitable for use with all multimeters Q Point the probe at the surface of the object. The sensor supplies a voltage proportional to the temperature measured (1 mV / °C) Q C.A 1871 delivered with: Q 1 x 9V LR14 battery SPECIFICATIONS C.A 1871 Distance/Spot ratio 8/1 Emissivity Fixed 0.95 Measurement range - 30 °C to + 550 °C Accuracy ± 2 % of reading Dimensions / weight 164 x 50 x 40 mm / 182 g °C IR
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 168 STRENGTHS Q Rugged thanks to their shockproof protective sheath Q Temperature measurement up to 1,350 °C Q Measurement accuracy Q Stability of the sensor over time Q Infrared measurement possible with the C.A 876 Q 1 flexible K-thermocouple sensor SPECIFICATIONS C.A 876 IR measurement Contact measurement Distance/Spot ratio 10/1 - Emissivity 0.1 to 1 - Measurement range - 20 °C to + 550 °C - 40 °C to + 1350 °C Accuracy ± 2 % R or ± 3 °C ± 0.1 % R +1 °C Functions Max., Min., Avg., HOLD, Alarms Dimensions / weight 173 x 60.5 x 38 mm / 255 g ACCESSORIES / REPLACEMENT PARTS °C °F IR C.A 876 Ref. : P01651403Z
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 169 IP 65 °C TK 2000 - TK 2002 Ref. : P01653100 P01653110 STRENGTHS Q Compact, accurate and simple to use: connect the sensor and start measuring! Q Usable in all environments thanks to their IP 65 protection Q Measures the temperature difference by means of the 2 thermocouple inputs on the TK 2002 Q TK 2000 delivered with: Q 1 flexible K-thermocouple sensor Q 1 x 9 V 6LR61 battery Q TK 2002 delivered with: Q 2 flexible K-thermocouple sensors Q 1 x 9 V 6LR61 battery SPECIFICATIONS TK 2000 TK 2002 No. of inputs 12 Range - 50 °C to +1,000 °C Accuracy ± 1.5 % + 0.5 °C Functions HOLD, °C Dimensions 163 x 63 x 37.5 mm Weight 200 g ACCESSORIES / REPLACEMENT PARTS
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 170 C.A 1821 - C.A 1822 Ref. : P01654821 P01654822 STRENGTHS Q J, K, T, N, E, R, S thermocouples Q Recording of up to 1 million points Q Magnetized product compatible with MultiFix Q USB and Bluetooth communication Q Backlit digital display C.A 1821 and C.A 1822 delivered with: Q 1 bag Q 3 x 1.5 V LR6 batteries Q 1 USB cable Q 1 measurement report ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 °C °F ADDITIONAL INFO Q Shockproof sheath available as an accessory Q Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report SPECIFICATIONS C.A 1821 C.A 1822 Sensor Thermocouple J, K, T, N, E, R, S No. of inputs 1 2 Measurement range J: 210 to + 1,200 °C / 346 to + 2,192 °F K: 200 to + 1,372 °C / 328 to + 2,501 °F T: 250 to + 400 °C / 418 to + 752 °F N: 200 to + 1,300 °C / 328 to + 2,372 °F E: 150 to + 950 °C / 238 to + 1,742 °F R 0 to + 1,767 °C / 32 to + 3,212 °F S 0 to + 1,767 °C / 32 to + 3,212 °F Resolution Display in °C: ø < 1,000 °C: 0.1 °C and ø ≥ 1,000°C: 1 °C Display in °F: ø < 1,000 °F: 0.1 °F and ø ≥ 1,000°F: 1 °F Accuracy (J. K. T. N. E) ø ≤ - 100°C ± (0.2% Reading + 0.6°C) (R. S) Functions Min., Max., HOLD, alarms, temperature differential (C.A 1822) Recording Manual Start / Stop on the product Programmed recording Alarms Visual alert on threshold overrun set via Data Logger Transfer Recording can be triggered on alarm threshold Data storage More than one million points Power supply 3 x 1.5V LR6 alkaline batteries or NiMH rechargeable battery Mains connection possible with the mains / micro USB adapter (option) Battery life 1,000 hrs (portable mode) 3 years for recording (15-minute measurement interval) Dimensions/ weight 150 x 72 x 32 mm / 260 g with batteries Ingress protection IP54 casing Operating temperature/ humidity -10 to +60 ° C / 10 to 90 % RH Standards IEC61010-1 / IEC 61326-1
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 171 C.A 1823 Ref. : P01654823 STRENGTHS Q Pt100 or Pt1000 resistance probe Q Recording of up to 1 million points Q MultiFix-compatible magnetized product Q USB and Bluetooth communication Q Backlit digital display C.A 1823 delivered with: Q 1 bag Q 3 x 1.5 V LR6 batteries Q 1 USB cable Q 1 measurement report ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 °C °F ADDITIONAL INFO Q Shockproof sheath available as an accessory Q Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report SPECIFICATIONS C.A 1823 Sensor Pt100 or Pt1000 probe No. of inputs 1 Measurement range - 100 to + 400°C -148 to + 752°F Resolution Display in °C: 0.1 °C Display in °F: 0.1 °F Accuracy ± (0.4% R + 0.3°C) Functions Min., Max., HOLD, alarms Recording Manual Start / Stop on the product Programmed recording Alarms Visual alert on threshold overrun set via Data Logger Transfer Recording can be triggered on alarm threshold Data storage More than one million points Power supply 3 x 1.5V LR6 alkaline batteries or NiMH rechargeable battery Mains connection possible with the mains / micro USB adapter (option) Battery life 800 hrs (portable mode) 3 years for recording (15-minute measurement interval) Dimensions / weight 150 x 72 x 32 mm / 260 g with batteries Ingress protection IP54 casing Operating temperature/ humidity -10 to +60 ° C / 10 to 90 % RH Standards IEC61010-1 for 50 V voltages in category II / IEC 61326-1
CHOOSE YOUR INSTRUMENT FOR PHYSICAL MEASUREMENTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 172 C.A 847 C.A 1246 C.A 1227 C.A 850 C.A 852 C.A 895 C.A 1510 C.A 1052 page 175 page 174 page 176 page 178 page 178 page 185 page 184 page 177 Temperature measurement CMOS QQ Pt 100 sensor Q CTN Q 2-input K sensor Q Relative humidity measurement RH air QQ Q Dew point measurement QQ RH material Q Air-speed measurement Rotating-vane sensor QQ Hot-wire sensor Q Flow-rate measurement QQ Air-pressure measurement Differential pressure QQ Q High pressure (=> 10 bars) Q Low pressure (=> 100 mbar) QQ Gas measurement CO gas measurement Q CO2 gas measurement Q General functions HOLD QQQQQQQ Max QQQQQQQ Min QQQQ QQ Avg Via Data Logger Transfer QQ Choice of units QQQQ QQ Backlighting QQQQQQQ Alarm QQ Q Recording QQ QQ Software QQ QQ
CHOOSE YOUR INSTRUMENT FOR PHYSICAL MEASUREMENTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 173 C.A 1110 C.A 832 C.A 834 C.A 1725 C.A 1727 page 179 page 180 page 181 page 182 page 182 Lighting measurement < 200,000 lux Q Spectral correction Q Incidence correction Q Noise measurement A and C frequency weighting QQ Slow/fast time weighting QQ Analogue output QQ Speed measurement With and without contact QQ Rotation speed QQ Linear speed QQ Frequency, period QQ Duty cycle QQ Metering Q General functions HOLD Q QQQ Max Q QQQQ Min Q QQQ Avg Q Choice of units Q QQ Backlighting Q QQ Alarm Q Recording Q QQ Software Q QQ
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 175 STRENGTHS Q Measure the humidity of your materials very simply: prick the material and note the value corresponding to the LED which lights up. Q The C.A 847 is delivered with one 9 V 6LR61 battery SPECIFICATIONS C.A 847 RH range 6 to 100 % RH Accuracy RH ± 1 LED Dimensions 173 x 60.5 x 38 mm Weight 160 g C.A 847 Ref. : P01156302Z
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 177 C.A 1052 Ref. : P01175020 STRENGTHS Q Can be used for comprehensive surveys of air-conditioning, heating and ventilation systems Q Accurate, 5-in-1 instrument: measurement of air speed, relative humidity, flow-rate, pressure and temperature Q Complete: the instrument is delivered as standard with its probes in a case Q Particularly easy to use: connect the probe (recognized automatically) and measure! Q Data backup Q C.A 1052 delivered with: Q 1 case with all its probes Q 4 x 1.5 V LR06 batteries Q PhysicsLog software ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1052 Measurement range Accuracy Hot-wire speed 0.15 to 3 m/s ± 3 % R + 0.03 m/s 3.1 to 35 m/s ± 3 % R + 0.1 m/s Ø 100 mm rotating- vane speed 0.25 to 3 m/s ± 3 % R + 0.1 m/s 3.1 to 35 m/s ± 1 % R + 0.3 m/s Environmental temperature −20 °C to +80 °C ± 0.4 % R + 0.3 °C Flow-rate 0 to 99,999 m3/h 3 % R Relative humidity 3 to 98 % RH ± 1 % R + 1.5 % RH Dew point −50 °C to +70 °C ± 0.8 % R + 0.6 °C Pressure 0 to 1,000 mm H2O ± 0.2 % R + 1 Temperature (2 K-thermocouple inputs) −100 °C to +750 °C ±0.4 % R or 0.8 °C −200 °C to +400 °C ±0.4 % R or 0.5 °C Function HOLD, Min., Max., Avg. Recording 8,000 counts Dimensions 161.9 x 80.8 x 57.4 mm Weight 380 g Physics-Log software Choice of campaigns to be downloaded Linking of operator and customer to the campaigns C.A 1052 memory dump Display of the curves corresponding to the downloaded data Customization of the graphs Backup in pdf format for distribution to customer
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 178 C.A 850 - C.A 852 Ref. : P01184101 P01184102 STRENGTHS Q Accurate and simple to use Q Time/date-stamped monitoring Q Differential measurements Q C.A 850 delivered with: Q 1 hard case Q 2 connection tubes Q 1 x 9 V 6LR61 battery Q C.A 852 delivered with: Q 1 hard case Q 2 connection tubes Q 1 x 9 V 6LR61 battery SPECIFICATIONS C.A 850 C.A 852 Measurement range −6.89 to +6.89 bar −138 to +138 mbar Accuracy 0.3 % full scale Unit psi, bar, mbar, mmH2O, inH2O kbar, cmH2O, FtH2O, mmHg, OZin2, kg/cm2 - Functions Differential meas., Min., Max., HOLD Dimensions 182 x 72 x 30 mm Weight 220 g
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 179 C.A 1110 Ref. : P01654110 STRENGTHS Q Totally compliant lighting measurement in all directions Q Measures up to 200,000 lux Q Mapping of lighting measured for an area or room (MAP mode) Q Metrological compensation on Fluo LEDs. Q Min., Max., Avg. and HOLD Q Recording up to 1 million points Q C.A 1110 delivered with: Q 1 bag Q 3 x 1.5 V LR6 batteries Q 1 USB cable Q 1 measurement report SPECIFICATIONS C.A 1110 Measurement range 0.1 lx to 200,000 lx (lux) 0.01 fc to 18,580 fc Accuracy in standard mode Incandescent lamp ± 3% of reading LED ± 6% of reading (3,000 K to 6,000 K) Fluorescent lamp ± 9% of reading Accuracy in compensation mode LED mode ± 4% of reading (at 4,000 K) Fluo mode ± 4% of reading (type F11, 4,000 K) Functions Min., Max., HOLD, Average Recording Manual Start / Stop on the product Programmed recording MAP mode The MAP function can be used to map the lighting on a surface or in a room. In this way, the lighting measurements are saved in the same file. Data storage More than 1 million points Power supply 3 x 1.5V AA / LR6 alkaline batteries or NiMH rechargeable battery Mains connection possible with the mains / micro USB adapter (option) Battery life 500 hrs (portable mode) / 3 years of recording (15-minute measurement interval) Dimensions Casing: 150 x 72 x 32 mm Sensor: 67 x 64 x 35 mm (with protective cover) Spiral cable: 24 to 120 cm Weight 345 g with batteries Ingress protection IP50 casing Operating temperature / humidity -10 to +60 ° C / 10 to 90 % RH Standards Class C as per the French NF C 42-710 standard based on the CIE guidelines ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 LUX FC CLASS C NF C 42-710 LED FLUO ADDITIONAL INFO Q Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 180 dBA dBC C.A 832 Ref. : P01185501Z STRENGTHS Q Sound-level testing Q Simple to use Q C.A 832 delivered with: Q 1 shockproof sheath Q 1 jack socket for analogue output Q 1 universal adapter for tripod mounting Q 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Q 94 dB or 114 dB sound-level meter calibrator, C.A 833 ____ P01185301 Q See all the accessories on page 188 SPECIFICATIONS C.A 832 Measurement range 37 to 130 dB Calibres 3 calibres: 37 to 80 dB 50 to 100 dB 80 to 130 dB Accuracy ± 2 dB Frequency range 31.5 Hz to 8,000 Hz Functions A and C frequency weighting curves Fast and slow time weighting Analogue output 10 mV/dB or 1 VRMS Data storage - Software - Dimensions 237 x 60.5 x 38 mm Weight 230 g
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 181 dBA dBC C.A 834 Ref. : P01185502 STRENGTHS Q Monitoring of noise-exposure levels: recording of up to 32,000 values! Q Process the data on PC with the software supplied as standard Q C.A 834 delivered with: Q 1 hard case with data processing software Q 1 jack/USB cable Q 1 jack socket for analogue output Q 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Q 94 dB or 114 dB sound-level meter calibrator, C.A 833 ____ P01185301 Q See all the accessories on page 188 SPECIFICATIONS C.A 834 Measurement range 30 to 130 dB Calibres 4 calibres: 30 to 80 dB 50 to 100 dB 80 to 130 dB Auto 30 to 130 dB Accuracy ± 1.5 dB Frequency range 31.5 Hz to 8,000 Hz Functions A and C frequency weighting curves Fast and slow time weighting Min., Max, HOLD Analogue output 10 mV/dB or 1 VRMS Data storage 32,000 values Software Yes Dimensions 275 x 64 x 30 mm Weight 285 g
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 182 C.A 1725 - C.A 1727 Ref. : P01174810 P01174830 STRENGTHS Q Measurements up to 100,000 RPM Q Measurement with and without contact Q Multiple functions available: rotation speed, linear speed, counting, frequency, period Q Possibility of programming and storage capacity Q C.A 1727 Q USB connection to process the recordings on PC Q C.A 1725 delivered with: Q 1 hard case Q 1 FRB F connector Q 1 x 9 V LR14 battery Q 1 set of 15 strips of reflective tape (0.1 m long) Q 1 CD-ROM containing the user manual Q C.A 1727 delivered with: Q 1 hard case Q 1 FRB F connector Q 1 x 9 V LR14 battery Q 1 set of 15 strips of reflective tape (0.1 m long) Q 1 CD-ROM containing the TACHOGRAPH software ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1725 C.A 1727 RPM functions Range 60 to 100,000 RPM Accuracy 10 -4 R ± 6 cts m/min function Range 60 to 10,000 m/min. Accuracy 10 -4 R ± 1 increment Hz function Range 1 to 10,000 Hz Accuracy 4 x 10 -5 R ± 4 cts ms function Range 0.1 to 1,000 ms Accuracy 10 -4 R ±5 cts Report function Range 0.1 to 100 % Accuracy 0.1 % to 1 % Counting function Range - 0 to 100,000 events Accuracy - ± 1 events Functions Min., Max., HOLD, Smooth - High and low alarms Data storage - 4,000 counts Dimensions 21 x 72 x 47 mm Weight 250 g
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2016 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 183 STROBOSCOPE PHYSICAL & ENVIRONMENTAL MEASUREMENTS STRENGTHS Q Frequency or speed measurement without contact with rotating parts Q Digital frequency display Q Quartz time base Q White flash lamp, 40 joules ADDITIONAL INFO Q When the flashes from the stroboscope are directed at an object moving periodically and have the same frequency as the phenomenon observed, the object appears immobile. All you then need to do is read the frequency expressed in flashes/minute on the CDA 9452. To obtain the frequency in Hz, simply divide the reading by 60. Q CDA 9452 delivered with mains power cable CDA 9452 Ref. : P03197704 SPECIFICATIONS CDA 9452 LED display 10,000 points Measurement range 100… 1,000 flashes/min 1000… 10,000 flashes/min Resolution 1 flash/min Accuracy 0.05 % Power supply 220 V – 50/60 Hz Climatic conditions 0… + 50 °C / RH < 80 % Dimensions 210 x 120 x 120 mm Weight 1 kg Flashes /min
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2016 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 184 WWW.CHAUVIN-ARNOUX.COM 184 PPm CO2 °F°C RH C.A 1510 Ref. : P01651011 STRENGTHS Q CO2, temperature and humidity logger (up to 1 million points) Q Compact: for fixed or portable use Q User-friendly: thanks to the comfort-level indicators based on the level of CO2 and hygrothermal criteria Q Accurate: complies with the latest regulations on air-quality monitoring Q Low gas consumption thanks to its in-situ calibration kit Q Delivered in cardboard box with: Q 2 x 1.5 V LR06 batteries Q 1 USB mains adapter Q 1 USB-micro USB cable Q 1 desk stand Q Software Q 1 user manual (5 languages) on CD-ROM Q 1 verification certificate ADDITIONAL INFO Q Delivered in a metal case ACCESSORIES / REPLACEMENT PARTS Q See all the accessories on page 188 SPECIFICATIONS C.A 1510 Specifications for CO2 Measurement range 0 to 5,000 ppm Accuracy ± 50 ppm ± 3% of measured value Resolution 1 ppm Temperature measurement Measurement range -10 °C to +60 °C Accuracy ± 0.5 °C Resolution 0.1 °C Humidity measurement Measurement range 5 to 95 % RH Accuracy ± 2% RH Resolution 0.1% RH Product capabilities Portable measurement Quick measurement and display of the CO2, temperature and relative humidity values Indicator Mode 1D : CO2 confinement indication Visual indication (two-colour backlighting and pictograms) and/or audible indication of high confinement when the CO2 concentration is between 1,000 ppm and a 1,700 ppm threshold. 3D mode: indication of optimum comfort zone on the basis of hygrothermal criteria and the CO2 concentration Energy saving (ECO) For fixed use on battery power, the product performs measurements every 10 minutes over a programmable time range for a battery life of up to one year Logger Activation of programmed recording (P_REC) The start date, recording rate and end date can be customized with the PC software or the Android application. Possibility of locking the display in this mode (no values displayed). Manual activation (M_REC) Manual start and stop controls on the product. Recording is performed at the rate of the mode currently selected. Specifications Recording rate Customizable from 1 minute to 2 hours Data storage More than 1 million points Buzzer and units Yes / °C or °F Backlighting / Hold / Min Max Yes Dimensions / weight 125 x 65.5 x 32 mm / 190 g with batteries Power supply Batteries: 2 x 1.5 V AA / LR6 or rechargeable battery Connection to mains possible with mains / micro USB adapter supplied as standard Interfaces 2 communication modes possible: Bluetooth wireless communication and USB link; the product is then recognized as a USB key for easy file transfer Mounting C.A 1510 casing equipped with a magnet, a wall-suspension system and a slit for hanging the product. A wall support for use with a padlock (padlock not supplied) is available as an accessory, as is a desktop stand (supplied as standard with the C.A 1510W). Processing software delivered as standard Graphic representation or as table of values - Data export - Real-time mode- Report generation CO2, TEMPERATURE & HUMIDITY LOGGER PHYSICAL & ENVIRONMENTAL MEASUREMENTS
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2016 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 185 WWW.CHAUVIN-ARNOUX.COM 185 PPm CO C.A 895 Ref. : P01651001Z STRENGTHS Q Measures the level of carbon monoxide present in a room Q Checks the operation of combustion equipment Q Warning buzzer to indicate when there is a risk Q C.A 895 delivered with: Q 1 shockproof protective sheath Q 1 x 9 V LR14 battery ACCESSORIES / REPLACEMENT PARTS SPECIFICATIONS C.A 895 Measurement range 0 to 1,000 ppm Accuracy ± 5 % + 5 ppm Measurement mode Normal or Avg. Functions Alarm, Max., HOLD Dimensions 237 x 60.5 x 38 mm Weight 190 g CO DETECTOR PHYSICAL & ENVIRONMENTAL MEASUREMENTS
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2016 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 186 WWW.CHAUVIN-ARNOUX.COM 186 DATA PROCESSING SOFTWARE PHYSICAL & ENVIRONMENTAL MEASUREMENTS DATAVIEW® Ref. : P01102095 FUNCTIONS Q Configuration of all the functions of instruments connected to a PC or via Bluetooth Q Display of the data in table and graph form Q Export to an Excel spreadsheet or jpeg image Q Programming of recordings (date and rate) Q Automatic export of reports in Word format Q Windows Vista & Windows 7/8/10 (32/64 bit) Q 1 GB RAM for Windows Vista & Windows 7/8 (32 bit) Q 2 GB RAM for Windows Vista & Windows 7/8 (64 bit) Q 80 MB available space on hard disk (200 MB recommended) REQUIRED CONFIGURATIONADDITIONAL INFO Q Totally configurable alarms and recordings on alarms Q The Dataview® software automatically recognizes the instrument connected when it is hooked up to the PC and launches the corresponding menu. Users then have direct access to its configuration and to the stored data. Data Logger Transfer DataView® modules Data Logger Transfer Related products C.A 1821 C.A 1822 C.A 1823 C.A 1246 C.A 1227 C.A 1110 C.A 1510
PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2016 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 187 WWW.CHAUVIN-ARNOUX.COM 187 DATA PROCESSING SOFTWARE PHYSICAL & ENVIRONMENTAL MEASUREMENTS
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 188 Model Model Description SK20 Sheathed sensor as per the NF EN 61615 standard. Hot junction isolated from chassis-earth. Inconel 600 protective sheath SK6 “General-purpose” sensor recommended for measurements where access is difficult. Do not use in liquids (tip is not leakproof) SK2 Sensor with stainless-steel sheath which can be bent as required Radius of curvature > 4 mm SK3 Slightly bendable sensor with stainless-steel sheath SK13 Sensor with stainless-steel sheath SK7 In “calm” conditions without air movement, shake the sensor to encourage heat exchange SK17 In “calm” conditions without air movement, shake the sensor to encourage heat exchange SK1 Sensor with stainless-steel sheath for penetration (20 mm min.) in pasty, viscous or liquid specimens SK11 Sensor with stainless-steel sheath for penetration (20 mm min.) in pasty, viscous or liquid specimens SK4 Sheathed sensor with stainless-steel sensing element and Teflon base. For small flat surfaces. Contact can be improved by using silicone grease. SK14 For surface temperatures when access is difficult SK5 For flat surfaces. The spring ensures optimum contact even if the sensor is not positioned perpendicularly. Contact can be improved by using silicone grease. SK15 For flat surfaces. The spring ensures optimum contact even if the sensor is not positioned perpendicularly. Contact can be improved by using silicone grease. SK8 For measurements on pipes. The copper sheet is applied to the clean, dry pipe. The two-sided Velcro strip ensures contact by winding. SK19 Sensor with magnet for flat metal surfaces THERMOMETERS K-THERMOCOUPLE SENSORS Class I accuracy / -40 °C to +375 °C: ± 1.5°C / +375 °C to +1,000°C: ± 0.004 x T °C. Class II accuracy / -40 °C to +333 °C: ± 2.5°C / +333 °C to +1,200°C : ± 0.0075 x T °C.
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 189 Type / Application Measurement range Tolerance class 63% response time Plunger diameter Plunger length Ref. Model Flexible general-purpose sensor -40°C to 450°C Cl. 1 1 s 1.5 mm 1 m P01655010 SK20 Flexible sensor -50°C to 285°C Cl. 2 1 s contact 1 mm 1 m P03652906 SK6 Bendable general-purpose sensor -50°C to 1,000°C Cl. 2 3 s ambient 2 mm 1 m P03652902 SK2 Semi-rigid general-purpose sensor -50°C to 1,000°C Cl. 2 2 s 4 mm 50 cm P03652903 SK3 General-purpose sensor -50°C to 1,100°C Cl. 2 6 s 3 mm 30 cm P03652918 SK13 Air sensor for ambient measurements -50°C to 250°C Cl. 2 12 s 5 mm 15 cm P03652907 SK7 Air sensor for ambient measurements -50°C to 600°C Cl. 2 5 s 6 mm 13 cm P03652921 SK17 Needle sensor for penetration -50°C to 800°C Cl. 2 1 s 3 mm 15 cm P03652901 SK1 Needle sensor for penetration 50°C to 600°C Cl. 2 12 s 3 mm 13 cm P03652917 SK11 Surface sensor 0°C to 250°C Cl. 2 1 s 5 mm 15 cm P03652904 SK4 Elbowed surface sensor -50°C to 450°C Cl. 2 8 s 6 mm 13 cm P03652919 SK14 Surface sensor with spring -50°C to 500°C Cl. 2 1 s 5 mm Ø in contact 8.5 mm 15 cm P03652905 SK5 Surface sensor with spring -50°C to 900°C Cl. 2 2 s 8 mm 13 cm P03652920 SK15 Pipe sensor -50°C to 140°C Cl. 2 10 seconds on stainless-steel pipe with 12 mm diameter Ø 10-90 mm 32 cm P03652908 SK8 Magnetic sensor -50°C to 200°C Cl. 2 7 s 4 mm 1 m P03652922 SK19 Standard compensated miniature male 2-pole connector Spiral cable: 45 cm to 1m
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 190 WWW.CHAUVIN-ARNOUX.COM 190 REFERENCES TO ORDER Q Compensated miniature male 2-pole connector _________ P03652925 ACCESSORIES / REPLACEMENT PARTS CK 3 CK 2 CK 1 CK 4 EXTENSIONS FOR THERMOCOUPLES Q Pt 100 Ω temperature sensors Models Type Type / Application Description Measurement range Classe de tolérance Response time Ø Length Ref. SP 10 Surface sensor with spring For flat surfaces The spring ensures optimum contact, even if the sensor is not set up perpendicularly. - 50 °C to + 200 °C Cl. B 6 s 5 mm 13 cm P03652712 SP 11 Needle sensor For penetration (20 mm minimum) in pasty, viscous or liquid media. -100 °C to + 600 °C Cl. B 7 s 3 mm 13 cm P03652713 SP 12 Air sensor Suitable for all ambient air measurements (moving air). If the air is stationary, agitate the sensor to favour heat exchange. -100 °C to + 600 °C Cl. B 5 s 5 mm 13 cm P03652714 SP 13 Immersion sensor Sensor with stainless-steel sheath specially designed for liquids -100 °C to + 600 °C Cl. B 7 s 3 mm 13 cm P03652715 SP 14 General- purpose sensor 316L stainless-steel sensor for general use -100 °C to 450 °C Cl. A 7 s 3 mm 20 cm P01655020 CAPTEURS DE TEMPÉRATURE PT 100 Ω Accuracy class A / 0.15 °C + 0.002 x T °C Accuracy class B / 0.3 °C + 0.005 x T °C Miniature 3-pole flat-pin connector Spiral cable from 45 cm to 1m CK 1 CK 2 CK 3 CK 4 Models Description Ø Length CK 1 Terminated by male plug / female plug 4 mm 1 m CK 2 Terminated by male plug / 2 bare wires 4 mm 1 m CK 3 Terminated by 5-pin DIN plug / female socket 4 mm 1 m CK 4 Terminated by 2 banana plugs / female socket 4 mm 1 m Temperature withstand of extensions: -40 °C to +100 °C
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 191 C.A 1621, C.A 1623 and C.A 1631 CALIBRATORS C.A 1821, C.A 1822 and C.A 1823 Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ___ HX0053 THERMOMETERS C.A 1246 Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ____ HX0053 THERMO-HYGROMETER C.A 1227 Q Cones kit for vane flow-rate measurement (circular cross-section Ø 210mm and rectangular cross-section 346x346mm) Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ___ HX0053 THERMO-ANEMOMETER C.A 1110 Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ___ HX0053 LUXMETER C.A 1052 Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ___ HX0053 MULTI-FUNCTION INSTRUMENT C.A 1886 and C.A 1888 THERMAL CAMERAS
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 192 WWW.CHAUVIN-ARNOUX.COM 192 C.A 832 and C.A 834 Q C.A 833, 94 dB or 114 dB sound-level meter calibrator ___ P01185301 Q Microphone extension for C.A 834 (5 metres) _________ P01102085 SOUND-LEVEL METERS C.A 1725 and C.A 1727 TACHOMETERS C.A 1510 Q Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger ___ HX0053 CO2, TEMPERATURE & HUMIDITY LOGGER C.A 895 CO DETECTOR FIND ALL OUR ACCESSORIES ON PAGE 232
ACCESSORIES / REPLACEMENT PARTS PHYSICAL & ENVIRONMENTAL MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 193 For the C.A 834 For the C.A 1227 - C.A1110 - C.A1821/22/23 - C.A1246 For the C.A 1227 For the C.A 832 - C.A834 For the C.A 1225 - C.A1727 For the C.A1510 For the C.A1510 For the C.A1510
& MICROWAVE MEASUREMENTS Info and advice 196 LAN tester 199 Fieldmeters 200 Wattmeters / reflectometers 202 Accessories 203
RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 196 COMPUTER NETWORK AND TELECOM TESTING The wiring of a physical infrastructure may be defined as a set of specific elements through which it is possible to transfer information. Usually linked to computer networks, the performance requirements of wiring systems are evolving rapidly and they must now be capable of conveying other types of information, such as voice or video. COPPER NETWORK WIRING A category-5 or higher network cable comprises an external sheath, 8 copper wires organized in 4 pairs and an earth wire. There are different levels of cable shielding, with shielding per pair, global shielding or both. THE RJ45 CONNECTOR This connector with 8 positions and 8 electrical contacts is very widely used to terminate cables with twisted pairs: THE DIFFERENT TYPES OF CABLES The ISO/IEC 11801 standard defines official naming conventions for copper cables. The names describe the global protection of the cable, on the one hand, and the protection of the pairs of copper conductors, on the other. Copper cables are named as follows: X / Y TP X: Global protection of the cable Y: Protection of the pairs TP: Twisted Pairs The following values are possible for X and Y: U = Unshielded, no protection S = Shielded with a tin-plated braid F = Foiled, shielded with aluminium foil Shielding efficiency U/UTP Global shielding: None (U) Shielding per pair: None (U) F/UTP Global shielding: Aluminium foil (F) Shielding per pair: None (U) SF/UTP Global shielding: Tin-plated braid and aluminium foil Shielding per pair: None (U) U/FTP Global shielding: None (U) Shielding per pair: Aluminium foil (F) F/FTP Global shielding: Aluminium foil (U) Shielding per pair: Aluminium foil (U) S/FTP Global shielding: global tin-plated braid Shielding per pair: Aluminium foil per pair MODULAR MALE RJ45 JACK SOCKET T568A (clip below) T568B (clip below) EIA/TIA 568A standard Name No. Colour TD+ 1 White/Green TD- 2 Green RD+ 3 White/ Orange Not used 4 Blue Not used 5 White/Blue RD- 6 Orange Not used 7 White/Brown Not used 8 Brown EIA/TIA 568B standard Name No. Colour RD+ 1 White/ Orange RD- 2 Orange TD+ 3 White/Green Not used 4 Blue Not used 5 White/Blue TD- 6 Green Not used 7 White/Brown Not used 8 Brown 12345678 12345678
RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 197 MEASUREMENT OF ELECTROMAGNETIC FIELDS Any system using electricity as an energy source generates electromagnetic radiation when it is in operation. Depending on the design of the system, the electromagnetic fields which it produces may be propagated in the space around it, extending significantly further than the external limits defined by its enclosure (casing) or the site where it is installed. This is the case for electrical machinery, motors, welding units, induction furnaces, high-voltage power lines, transformer stations, household electrical appliances and electronic instruments used for data processing, transmission, monitoring or measurement. These electromagnetic fields interact with matter, both inanimate (interference with nearby electrical devices) and animate (plants, animals, etc.). It is therefore important to be able to measure the values of the radiated magnetic and electric fields propagated around any electrical or electronic device:
- to overcome the purely technical problems linked to the electromagnetic compatibility of instruments and machines,
- but also to make sure that the people living and working near these electrical systems are not exposed to fields liable to cause lasting or even temporary negative effects on them. THE ELECTROMAGNETIC WAVE The electromagnetic wave is the radiated energy produced by the oscillation of an electrical load . It is characterized by oscillation of the electrical and magnetic fie l d s . Ea c h syst e m g e n e r a t i n g or a b sorb i n g e l ect ri c a l energy is the source of electromagnetic waves in the form of variable electric fields and magnetic fields which are propagated in the air at the speed of light. Roughly speaking, an electromagnetic wave comprises: The electric field (E): generated by the difference in potential between two conductors subjected to an electrical voltage, this field depends on the voltage V. The m a gnetic field (H) : a s th i s field i s generated by a current in a conductor, it depends on the current i. In the case of a sinusoidal alternating wave, the electric field E and the magnetic field H are sinusoidal and in phase. Their directions are perpendicular to one another and perpendicular to the direction of propagation. This wave is characterized by its frequency F in Hertz (Hz) or its wavelength in metres; these two quantities are linked by the following relation: λ = C o / F where Co = the speed of light in m/s, i.e. 300,000 km/s = 3 x 108 m/s F = frequency in Hz λ = wavelength in m Example: for a wave at 300 MHz, the wavelength is 1 metre. Representation of the three components of an electromagnetic wave
RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 198 MEASUREMENT OF ELECTROMAGNETIC FIELDS THE ELECTROMAGNETIC SPECTRUM The electromagnetic spectrum is the decomposition of the electromagnetic radiation into its different components in terms of wavelength. Some waves can be detected with the human eye, while others have much lower frequencies detectable using radio devices. INTERACTIONS WITH MATTER The effects of electric and magnetic fields on matter and tissues vary according to their frequency and their intensity. Low-frequency fields are liable to induce electric currents in matter and biological tissues. Effects described as “thermal” may follow. These thermal effects are the basis for the action of higher-frequency fields used in certain applications (cooking and drying with microwaves). OBLIGATIONS The International Commission on Non-Ionizing Radiation Protection (ICNIRP) has defined exposure limits adopted in many countries. The exposure limits adopted by the European Community are based on a recommendation issued by the ICNIRP , including those in Directive 1999 / 519 / CE (public) and the recent directive 2013/35/UE of 26th June 2013 concerning workers’ exposure to electromagnetic fields, which must be transposed into law in the member states by 1st July 2016. For the latter directive, the employer’s role will be to assess the hazards and determine the exposure which can be measured in order to find out objectively whether the standard recommended thresholds have been exceeded or not. WIRE WIRELESS OPTICAL FIBRE Wavelength (m) House Radio waves AM radio FM radio Radar Microwave oven Mobile phone Human body Electric light bulb Synchrotron Radiography Infrared Ultraviolet “Hard” X-rays Rayons X “mous”Microwaves Football This dot Cell Virus Water molecule Size of the wave Sources Frequency (Hz) 11 0 -10 -11 -12
RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 199 RJ C.A 7028 Ref. : P01129501 STRENGTHS QGraphical screen QDetects, identifies and locates faults from up to 150 m away Q Designed for use on UTP , STP , FTP , & SSTP cables equipped with RJ45 connectors and wired in compliance with the TIA 568A/B, USOC or ISDN specifications Q C.A 7028 delivered with: Q2 RJ45 leads Q1 identifier no. 1 Q1 soft case Q4 x 1.5 V LR06 batteries ACCESSORIES / REPLACEMENT PARTS QSee all the accessories on page 203 SPECIFICATIONS C.A 7028 Connector RJ 45 Types of cables UTP, STP, FTP & SSTP Faults indicated Short-circuited pair, Wire in open circuit, Short-circuit between pairs, Crossed pairs, Reversed pairs, Shielding continuity Remote modules Identifiers nos. 1 to 9 Dimensions 165 x 90 x 37 mm Weight 350 g
RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 200 C.A 40 Ref. : P01167501 STRENGTHS QMeasurement of low-frequency magnetic fields QQuick assessment of the radiation from equipment and installations QEasy-to-handle unidirectional probe ACCESSORIES / REPLACEMENT PARTS SPECIFICATIONS C.A 40 Magnetic field measurement 20 μT 200 μT 2,000 μT Accuracy ±(4 %+3 cts) ±(5 %+3 cts) ±(10 %+5 cts) Frequency range 30 to 300 Hz Power density - Output - Probe Unidirectional Alarm - Data storage - Dimensions 163 x 68 x 24 mm Weight 285 g
HIGH-FREQUENCY FIELDMETERS RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 201 STRENGTHS Q Measurement of electric fields and detection of radiation sources over a wide frequency band QIsotropic probe: measures the field in all directions QStorage of measurement points with the C.A 43 Q C.A 41 delivered with: Q1 hard case Q1 EF2A probe Q1 x 9 V 6LR61 battery Q C.A 43 delivered with: Q1 hard case Q1 EF2A probe QOptical fibre Q1 PC adapter Q1 CD-ROM containing data processing software Q1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS QSee all the accessories on page 203 C.A 41 - C.A 43 Ref. : P01167001B P01167002A SPECIFICATIONS C.A 41 C.A 43 Electric field measurement 0.1 to
1 V/m 1 to 10 V/m 10
Accuracy 0.7 V/m 0.5 V/m 1 dB 2 dB Frequency range 100 kHz to 2.5 GHz Power density - 0.1 to 2 mW/cm 2 Output Analogue Digital on optical fibre Probe Isotropic Alarm Configurable high and low thresholds Data storage - 1,920 points Dimensions 216 x 72 x 37 mm Weight 350 g
WATTMETERS / REFLECTOMETERS RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 202 RW 511 - RW 5012 - RW 501 Ref. : P01255102 P01255104 P01255101 RW 521 Ref. : P01255103 STRENGTHS Wattmeters developed for military and civilian applications: QSimple installation testing QTesting of the assembly comprising the transmitter, cable and antenna Q 1 product for each market:
- Single side-band transmission (RW 511)
- VHF networks, police, emergency services (RW 5012)
- Radio, FM and TV networks (RW 501)
- Rural VHF – HF networks (RW 521)
Q RW 511 delivered with: Q1 x 9V 6LR61 battery Q RW 5012, RW 501 and RW 521 delivered with: Q2 x 1.5 V LR06 batteries ACCESSORIES / REPLACEMENT PARTS QSee all the accessories on page 203 SPECIFICATIONS RW 521 RW 511 RW 5012 RW 501 Frequencies 1.3 …
2.7 GHz
2 …
30 MHz
25 …
500 MHz
25 … 1,300 MHz Incident power +10 … +40 dBm 30 … 1,000 W 1 … 300 W 1 … 300 W Reflected power +5 … +35 dBm 10 … 300 W 0.3 … 100 W 0.3 … 100 W
ACCESSORIES / REPLACEMENT PARTS RADIOFREQUENCY & MICROWAVE MEASUREMENTS 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 203 C.A 7028 RW 511, RW 5012, RW 501 and RW 521 C.A 40 C.A 41 and C.A 43 LAN TESTER WATTMETERS/REFLECTOMETERS FIELDMETERS FIND ALL OUR ACCESSORIES ON PAGE 230
LABORATORY & EDUCATIONAL INSTRUMENTATION Info and advice 206 Training benches 207 Training cases 210 Other instruments 213
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 206 Electricity, electronics, physics, industrial maintenance & the environment: these are disciplines where measurement is crucial for identifying and understanding theoretical phenomena through practical experience. We offer simple, educational equipment to help students to learn about subjects ranging from the study of electrical signals to the maintenance of electrical systems. STUDYING SIMPLE ELECTRICAL PHENOMENA COMPLIANCE WITH THE IEC 61010-1 STANDARD PRACTICAL APPLICATIONS ENCOURAGE SUCCESSFUL LEARNING In Electronics training, students discover the techniques using electrical signals to capture, transmit, process, store and view data. To help them, the electrical quantities may be generated by decade boxes or simulation cases. These quantities are measured by traditional measuring instruments such as voltmeters, ammeters, wattmeters and multimeters. These resistance, capacitance or inductance decade boxes are passive elements for insertion into test or development circuits in order to obtain the required resistance, capacitance or inductance values by combination. These decade boxes comply with the IEC 61010-1 safety standard which establishes the safety rules for electrical measuring, control and laboratory instruments. This standard defines the normal environmental conditions of use:
- Indoor use
- Altitude up to 2,000 m
- Temperature from 5 °C to 40 °C
- Maximum relative humidity of 80 % at temperatures up to 31 °C, with a linear decrease down to 50 % relative humidity at 40 °C
- Fluctuations of the network supply voltage from the network not exceeding ±10 % of the rated voltage
- Norm a l presence of tra nsient overvoltages on the network power supply Electrical installation cases, power and harmonics cases, microwave test benches and an infrared thermography bench: Chauvin Arnoux provides students with ready-to- use educational units which are ideal for a large number of experiments. Their overall design aims to ensure simple use and measurements. Delivered with a guide containing practical exercises accompanied by the corresponding theoretical elements, these training cases enable students to boost their knowledge with practical skills likely to prove useful during their careers. Quantity Unité Resistance R Ω (ohm) Current I A (ampere) Voltage V V (volt) Power P W (watt) Capacitance C F (farad) Inductance L H (henry) Resistance box
THERMOGRAPHY TRAINING BENCH LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 207 PRACTICAL EXERCISES C.A 1875 Ref. : P01651620 STRENGTHS Q Highlighting of the various possible errors in thermography: problems linked to emissivity, spatial resolution, angle of measurement, transmission or reflection Q Simple use and simple measurements Q Delivered with a booklet of practical exercises accompanied by the corresponding theoretical principles Q C.A 1875 delivered in a bag with: Q1 mains power cable QTest sheets Q1 booklet presenting the theoretical principles and practical exercises SPECIFICATIONS C.A 1875 Emissivity of materials The influence of emissivity on temperature measurement is demonstrated using sheets of different materials Positioning Visual demonstration of the influence on temperature measurement of camera positioning in relation to the target Reflection and transmission Visual demonstration of reflection and transmission phenomena and their influence Spatial resolution Detection of minimum areas for temperature measurement according to the distance from the target Power supply 230 V – 50 / 60 Hz
MICROWAVE TRAINING BENCHES LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 208 PRACTICAL EXERCISES BDH R100 Ref. : P01275101 STRENGTHS Q Dedicated to teaching about 8.5 to 9.6 GHz microwaves with guided propagation Q WR90/R100 waveguide equipped with a quick mounting system Q Supplied with detailed course, teaching and lab work material Q Various accessories for setting up a wide range of experiments SPECIFICATIONS BDH R100 Main possible experiments Study GUNN oscillator Measurements Impedance Wavelength Frequency Standing wave ratio Readings Quadratic law of a detector ELEMENTS FOR FREE-SPACE PROPAGATION Reference 1 20 dB ANC 100/20 horn antenna P01275326 2 15 dB ANC 100/15 dB horn antenna P01275304 3 10 dB ANC 100/10 horn antenna P01275325
4 RRL100 passive radar responder P01275333
5 DR100 reflector disk P01275334
6 AND100 dielectric antenna P01275329
7 ASP100 patch antenna P01275328
8 ANF100 adjustable slot antenna P01275332
ANF100F fixed slot antenna P01275331 IANF100 iris for adjustable slot antenna P01275330 ANP100 adjustable parabolic reflector P01275327
9 ANP100F fixed parabolic reflector P01275335
ORITEL CF 204 GUNN power supply ORITEL BDH R100 training bench Q BDH R100 delivered in a case with: Q1 ORITEL OSG 100 GUNN diode oscillator Q1 ORITEL ISO 100 ferrite isolator Q1 ORITEL MOD 100 PIN diode modulator Q1 ORITEL ATM 100 variable attenuator Q1 ORITEL OND 100 cavity wavemeter with curve Q1 ORITEL LAF 100 measuring line Q1 ORITEL ADZ 100/3 impedance adapter Q1 ORITEL TGN 100 waveguide-to-coaxial transition element Q1 ORITEL DEN 100 coaxial detector Q1 ORITEL CHG 100 adapted load Q1 ORITEL CC 100 short-circuit plate Q3 ORITEL SUP 100 guide supports
MICROWAVE TRAINING BENCHES LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 209 ADDITIONAL COMPONENTS Reference
1 ORITEL RD 100 displacement copy
(for ORITEL LAF 100 measuring line) P01275302
2 DPH100 micrometer phase shifter P01275340
3 JTG100 rotating joint P01275338
4 CIR100 ferrite circulator P01275344
5 DEG100 parallel detector on guide P01275345
6 PEH100 E-H positioner P01275358
7 GD100/180 180 mm straight waveguide P01275350
8 COE100/H high plane E bend P01275346
COE100/B low plane E bend P01275347 COH100 plane H bend P01275348
9 CCM100 micrometer short-circuit P01275351
10 Calibrated attenuator P01275339
11 LAZ100 movable impedance adapter P01275352
12 KED100 dielectric kit P01275353
13 CDT100 multi-hole directional coupler P01275341
ICDT100/30: 30 dB iris for multi-hole coupler P01275343
14 CAB100: 1 m coaxial cable P01275357
ACCESSORIES / REPLACEMENT PARTS Reference
1 Manual rotating platform – PTM100 P01275359
2 Set of 2 absorbent panels – ABS100 P01275362
3 Antenna support – SAN100 P01275360
4 Antenna support rod P01275349
5 Waveguide support– SUP100 P01275318
Experiment frame P01275361 ACCESSORIES / REPLACEMENT PARTS Reference ORITEL OSG 100 GUNN diode oscillator Voltage: 10 VDC - Power: +17 dBm P01275307 ORITEL MOD 100 PIN diode modulator Modulation depth > 50% for I = +10 mA P01275309 ORITEL OND 100 cavity wavemeter with curve Reading accuracy: 5 MHz P01275311 ORITEL LAF 100 measuring line Residual SWR: < 1.05 P01275312 ORITEL DEN 100 coaxial detector SWR: < 1.3 - Max. power: +19 dBm P01275315 ORITEL ISO 100 ferrite isolator Isolation: > 20 dB P01275308 ORITEL ATM 100 micrometer attenuator Attenuation: > 20 dB - Max. power: 1 W average P01275310 ORITEL ADZ 100/3 impedance adapter Number of transverse plates: 3 P01275313 ORITEL TGN 100 waveguide-to-coaxial transition element SWR: < 1.25 P01275314 ORITEL CHG 100 adapted load SWR: < 1.05 P01275316 ORITEL CGX 100/20 dB cross coupler Coupling: 20 dB - Directivity: 15 dB typ. P01275305 IRIS 100 coupling iris (for CGX100) 20 and 30 dB coupling P01275306 ORITEL ANC 100/15 dB horn antenna Gain: 15 dB Flange: UBR 100/UG 39 P01275304 ORITEL AFR 100 Compatible with UBR 100 / UG 39 flanges P01275301 ORITEL RD 100 displacement copy For ORITEL LAF 100 measuring line P01275302 1112 * You are advised to use the GUNN CF204 power supply to power GUNN diode oscillators safely
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 210 C.A 6710 case Power & Harmonics Case page 211 page 212 Electrical installation testing and safety Earth/ground Q Soil resistivity Q Loop Q Insulation Q RCD Q Leakage current Q Power and Harmonics Single & three-phase currents Q Single & three-phase voltages Q Active, reactive and apparent power, cos φ, PF… single and three-phase Q Voltage variation Q Current variation Q Current phase-shift variation Q THD variation on voltage and current Q
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 211 C.A 6710 Ref. : P01145901 STRENGTHS QIdeal for learning about electrical safety measurements QSimulation of measurements on electrical installations QDepressurization valve for air transport Q C.A 6710 delivered with: Q1 x Schuko-type FR-DE mains power cable Q6 black safety leads 25 cm long with rear connection Q1 universal adapter for mains power sockets Q1 FR/DE adapter for mains power sockets ACCESSORIES / REPLACEMENT PARTS Q Set of 6 black Ø 4 male safety leads 25 cm long Q1 universal adapter for mains power sockets __________ P01101980 Q1 FR/DE adapter for mains power sockets ____________ P01101981 SPECIFICATIONS C.A 6710 Standards illustrated NF C 15-100, VDE 0100, IEE 16th, IEC 64-8, ÖVE EN-1, RBT MIE, NIN/NIV… Simulation of earthing systems TT, TN and IT Measurement simulations Earth, resistivity, loops (earth and internal), insulation, RCD tests (30 mA / 300 mA), current / leakage current Fault simulations Phase / neutral or earth interruptions, neutral / earth reversal, leakage current Electrical safety Cat. II 230 V Dimensions 490 x 395 x 195 mm Weight 10 kg ELECTRICAL INSTALLATIONS
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 212 POWER & HARMONICS Ref. : P01NC5003 STRENGTHS QHazard-free simulation of a network and a three-phase load QVariable currents, voltages, phase shift and THD QCase delivered with: Q1 mains power cable ACCESSORIES / REPLACEMENT PARTS ADDITIONAL INFO QThe current sensors are not delivered with the training case. SPECIFICATIONS Power & harmonics Network simulations SINGLE or THREE--phase (230 V mains power supply) Measurement simulations U, I, W, W/h, var, φ, THD, etc. Voltage Mains ± 15 % Current 1, 2, 5, 10, 20 A ± 10 % Voltage variation* + 8 % ; −10 % Current phase shift* 30°, 45°, 60° ± 5° inductive or capacitive Harmonic distortion on current and voltage* Network level, 15 %, 25 % and variable Phase outage Yes Power supply 230 V mains - 2 P + E socket Electrical safety IEC 61010 300 V Cat II pollution 2 Dimensions 490 x 395 x 195 mm Weight 10 kg *on phase 1 POWER AND HARMONICS
CHOOSE YOUR INSTRUMENT FOR SIMULATING THE ELECTRICAL QUANTITIES LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 213 C.A 401 C.A 402 C.A 403 C.A 404 C.A 405 DECADE BOXES SHUNT WHEATSTONE page 214 page 214 page 214 page 214 page 214 page 215 page 215 page 215 page 215 page 215 page 217 page 215 Specifications AC / DC ammeter Q AC / DC voltmeter Q Null galvanometer Q Single/three-phase wattmeter QQ 1-decade resistance box Q 1-decade capacitance box Q Multi-decade resistance boxes Q Multi-decade capacitance boxes Q Multi-decade inductance boxes Q Shunts Q Wheatstone bridge (sub-assembly for) Q
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 214 600 V CAT III C.A 401 - C.A 402 - C.A 403 Ref. : P01170301 P01170302 P01170303 C.A 404 - C.A 405 Ref. : P01170304 P01170305 STRENGTHS QEconomical and rugged QResistant casing with removable stand QSingle switch QSafety sockets QDouble insulation Q1 x 1.5 V LR06 battery SPECIFICATIONS Function AC/DC ammeter AC/DC voltmeter Null galvanometer 2 black scales (0 to 30 and 0 to 100) Single-phase AC/DC wattmeter Single and three-phase AC/ DC wattmeter Switchgear Magneto-electric rectifying Magneto-electric Ferrodynamic Calibres Voltage 100 mV DC cal. for shunts 8 DC cal.:100 mV to 1,000 6 AC cal.: 3 V to 1,000 V* 1 DC cal.: 100 mV for shunts 4 cal.: 60 V to 480 V 6 single-phase cal.:60 V to 480 V 4 balanced three-phase cal.: 60 V√3 to 240 V√3 Current 11 DC cal.: 100 μA to 10 A 7 AC cal.: 10 mA to 10 A 2 DC cal.: 30 μA, 3 mA 2 cal.: 0,5 A; 1 A 1 cal. 5 A Resistance Basic accuracy 2 % DC 2,5 % AC 1,5 % DC 1 % AC 2.5 % DC. 1 % AC mono. et 2 % AC tri. Operating frequency 45 to 400 Hz 20 to 400 Hz 0 to 500 Hz 15 to 500 Hz Fuses 1 A HPC and
10 A HPC
Internal resistance: 20 kΩ/VDC ; 6.32 kΩ/VAC 315 mA HPC 1,25 A HPC 6,3 A HPC Electrical safety 600 V CAT III as per IEC/EN 61010-1 Edition 2 Dimensions 165 x 105 x 50 mm Weight 450 g *Use limited to 600 V maximum ACCESSORIES / REPLACEMENT PARTS
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 215 References 1 decade 0,1 to 1 Ω P03197521A 1 to 10 Ω P03197522A 10 to 100 Ω P03197523A 100 to 1,000 Ω P03197524A 1 to 10 kΩ P03197525A 10 to 100 kΩ P03197526A 100 to 1,000 kΩ P03197527A 1 to 10 MΩ P03197528A BR 04 : 4 decades 1 Ω to 10 kΩ P01197401 BR 05 : 5 decades 1 Ω to 100 kΩ P01197402 BR 06 : 6 decades 1 Ω to 1 MΩ P01197403 BR 07 : 7 decades 1 Ω to 10 MΩ P01197404 References 7-ratio K box P03197531A Null galvanometer P03197611A Dual switch box P03197529A Simple changeover-switch box P03197530A BK Bat X G G = null galvanometer BK = K ratio box - with K = R2 R3 = resistance boxes X = resistance to be measured - with X = K x R3 B1 = simple changeover-switch box B2 = dual switch box Bat = battery RESISTANCE BOXES ASSEMBLY FOR WHEATSTONE BRIDGE ACCESSORIES / REPLACEMENT PARTS Q 1 black safety lead 25 cm long, Q 1-decade box delivered with 1 black safety lead 25 cm long, Ø 4 mm male with rear connection QBR 04/05/06/07 boxes are delivered with a user manual only. IEC/EN6110-1 - 150 V CAT II - Pol 2
50 V CAT III
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 216 References 1 decade 0.01 to 0.1 μF P03199613A 0.1 to 1 μF P03199612A 1 to 10 μF P03199611A BC 05 : 5 decades 0.1 nF to 10 μF P01197421 STRENGTHS Elements for mechanical and electrical assemblies QSelection by rotary switch with contacts QTypical accuracy: 2% 1-decade boxes Q3 boxes with 11-position switch (including position 0) Q2 safety terminals Ø 4mm and one earth terminal QDimensions: 72x72x90 mm 5-decade box Q Polystyrene and polypropylene high-accuracy capacitors with a temperature coefficient of 125 ppm/°C and a very high insulation resistance Q Output: Ø 4mm safety sockets Q Metal front panel and casing connected to a safety earth socket with foolproofing CAPACITANCE BOXES ACCESSORIES / REPLACEMENT PARTS Q 1 black safety lead 25 cm long, Q 1-decade box delivered with: Q1 black safety lead 25 cm long, Ø 4 mm male with rear connection QBC05 box delivered with a user manual only. IEC/EN6110-1 - 150 V CAT II - Pol 2
LABORATORY & EDUCATIONAL INSTRUMENTATION 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 217 References
1 A P01165221
5 A P01165222
10 A P01165223
20 A P01165224
30 A P01165225
BL 07 : 7 decades from 1 μH to 10 H P01197451 STRENGTHS Q4-wire measurement QRed “current” terminals QBlack “voltage” terminals INDUCTANCE BOXES
100 MV SAFETY SHUNTS
IN DOUBLE-INSULATED CASING Q BL07 box delivered with a user manual only Q Shunt delivered with a user manual only IEC/EN6110-1 - 150 V CAT II - Pol 2
Flexible sensors and probes 224 Accessories / replacement parts 229
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 220 MINI 0X MINI 10X MN YN C1XX page 222 page 222 page 222 page 222 page 223 For current Clamping Ø mm) 10 16 20 30 52 AC QQQQQ DC Min 5 mA 5 mA 10 mA 1 A 1 mA MAX 150 A 200 A 240 A 600 A 1200 A Output in mAAC QQQQQ in mVAC QQQQQ in mVDC QQ Q in mVAC+DC Connections Insulated Ø 4 mm sockets QQ Lead with insulated elbowed Ø 4 mm male plugs QQQQQ Insulated Ø 4 mm plug box with standard 19 mm spacing Coaxial cable with insulated male BNC QQQ Single-calibre QQQQQ Multi-calibre QQQ For multimeters Q QQQ For oscilloscopes QQQ For detecting leaks and insulation faults QQ For measuring power values, harmonics, etc. QQQ Q For the process and the 4-20/0-20 mA measurement loop Power supply Self-contained QQQQQ
9 V battery
There is a wide range of criteria for choosing a current clamp. The approach below is designed to help define your requirements and guide you naturally towards the model which best suits your application. The criteria selected are classified from 1 to 6. To choose your clamp, we advise you to follow this logic: QMeasurement of direct or alternating current? ´ AC/DC clamps table or AC clamps table QHigh or low currents? ´ see the “Input” column to define the appropriate families of clamps QOn small wires or large cables? ´ see the diagrams at the bottom of the next page and only choose families with the shapes and dimensions required QWhat instrument will it be connected to? ´ see “Output / Connection” column to choose a clamp with compatible signal and connection possibilities QWhat are your other criteria? ´ see “Specific features” column to check that the clamp chosen fulfils your requirements perfectly Our innovation, technical expertise and determination to manufacture top-quality products that comply with standards have made Chauvin Arnoux the worldwide specialist in current clamps. On the next pages, you will find a table presenting the clamps for measuring AC/DC current, followed by a diagram giving the clamp form with dimensions and then another table grouping a large number of models for AC current. As a result of their specifications, certain clamps are specialized for specific applications: Q Clamps for oscilloscopes (BNC output): E3N, PAC12, PAC22, MN60, Y7N, C160, D38N and MA200 QClamps for leakage currents: MN73, C173 and B102 QProcess current clamps: K1 and K2 QClamp for measurement on the secondary windings of current transformers: MN71 As well as these standard specialized and unspecialized models, “specific” versions can also be produced on request: please ask for details. CHOOSING YOUR CURRENT CLAMP THE WIDEST RANGE OF IEC 61010-2-032 CLAMPS
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 221 DN BXX MiniFlex® Série MA110 MiniFlex® Série MA130 MiniFlex Série MA200 AmpFlex Série A110 AmpFlex Série A130 K EN MH60 PAC 1X PAC 2X page 222 page 222 page 224 page 224 page 224 page 226 page 226 page 223 page 223 page 223 page 223 page 223 For current 64 115 100 100 140 250 380 250 3,9 8 26 30 42 Clamping Ø mm) QQQQQQQQQQQQ AC QQQQQ DC 100 mA 500 μA 80 mA 500 mA 500 mA 80 mA 500 mA 100 μA 5 mA 1 mA 200 mA 200 mA Min
3600 A 400 A 3000 A 3000 A 3000 A 30000 A 3000 A 4,5 A 150 A 140 A 600 A 1000 A MAX
Q Insulated Ø 4 mm sockets QQQ Q Q QQ Lead with insulated elbowed Ø 4 mm male plugs Q Insulated Ø 4 mm plug box with standard 19 mm spacing Q QQ Q QQQQ Coaxial cable with insulated male BNC QQ Q Q Q Single-calibre QQQQQQQQQQQQ Multi-calibre QQQQ QQQQ QQ For multimeters Q Q QQQQ For oscilloscopes Q For detecting leaks and insulation faults QQ QQ QQQ Q For measuring power values, harmonics, etc. Q For the process and the 4-20/0-20 mA measurement loop Power supply QQ Q Self-contained QQQQQQQ QQ 9 V battery QQQQQQQQQQ Mains adapter
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 222 Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference MINI 01 2 to 150 A 0.15 AAC 1,000/1 48 Hz…500 Hz ≤ 2.5 % P01105101Z MINI 02 50 mA to 100 A 0.15 AAC 1,000/1 48 Hz…10 kHz ≤ 1 % P01105102Z MINI 03 1 to 100 A 0.1 VAC 1 A / 1 mV
48 Hz…500 Hz
≤ 2 % P01105103Z MINI 05 5 mA to 10 A 1 to 100 A
10 VAC
0.1 VAC
1 A / 1 mV
≤ 3 % ≤ 2 % P01105105Z MINI 09 1 to 150 A 15 VDC(2) 1 A / 100 mV ≤ 4 % P01105109Z MINI102 0.05 A - 200 A 0.2 AAC 1000/1 48 Hz .. 10 kHz ≤ 1% P01106102 MN08 0.5 to 240 A 0.2 AAC 1,000/1
40 Hz…10 kHz
≤ 1 % P01120401 MN09 0.5 to 240 A 0.2 AAC 1,000/1 ≤ 1 % P01120402 MN10 0.5 to 240 A 0.2 AAC 1,000/1 ≤ 2 % P01120403 MN11 0.5 to 240 A 0.2 AAC 1,000/1 ≤ 2 % P01120404 MN12 0.5 to 240 A 2 VAC 1 A / 10 mV ≤ 1 % P01120405 MN13 0.5 A to 240 A 2 VAC 1 A / 10 mV ≤ 1 % P01120406 MN14 0.5 A to 240 A 0.2 VAC 1 A / 1 mV ≤ 1 % P01120416 MN15 0.5 A to 240 A 0.2 VAC 1 A / 1 mV ≤ 1 % P01120417 MN21 0.1 A to 240 A 0.2 AAC 1,000/1 ≤ 2 % P01120418 MN23 0.1 A to 240 A 2 VAC 1 A / 10 mV ≤ 1.5 % P01120419 MN38 0.1 A to 24 A
0.5 A to 240 A
2 VAC
1 A / 100 mV
1 A / 10 mV ≤ 1 % P01120407
MN39 0.1 A to 24 A
1 A / 10 mV ≤ 1 % P01120408
MN60 0.1 A to 60 Apeak
0.5 A to 600 Apeak
6 Vpeak
1 A / 10 mV 40 Hz…40 kHz ≤ 2 %
≤ 1.5 % P01120409 MN71 10 mA to 12 A 1 VAC 1 A / 100 mV ≤ 1 % P01120420 MN73 10 mA to 2.4 A 100 mA to 240 A
1 A / 10 mV
≤ 1 % ≤ 2 % P01120421 MN88 0.5 A to 240 A 20 VDC(2) 1 A / 100 mV ≤ 2 % P01120410 MN89 0.5 A to 240 A 20 VDC(2) 1 A / 100 mV ≤ 2 % P01120415 Y1N 4 A to 500 A 0.5 AAC 1,000/1
48 Hz…1 kHz
≤ 3 % P01120001A Y2N 4 A to 500 A 0.5 AAC 1,000/1 ≤ 1 % P01120028A Y3N 4 A to 500 A 5 AAC 100/1 ≤ 3 % P01120029A Y4N 4 A to 500 A 0.5 VDC(2) 500 A / 0.5 V ≤ 1 % P01120005A Y7N 1 A to 1,200 Apeak 1.2 Vpeak 1 A / 1 mV 5 Hz…10 kHz ≤ 2 % P01120075 (1) The upper value corresponds to 120 % of the max. rated value. (2) Reshaping of AC signal by diodes. 35 mm 130,4 mm 46 mm 34 mm 35 mm Ø 10 mm Ø 16 mm 115 mm 18.5 mm 51 mm 135 mm Ø 20 mm 34 mm 66 mm 213 mm 30 x 63 mm
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 223 Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference C100 0.1 A to 1,200 A 1 AAC 1,000/1
30 Hz…10 kHz
≤ 0.5 % P01120301 C102 0.1 A to 1,200 A 1 AAC 1,000/1 ≤ 0.5 % P01120302 C103 0.1 A to 1,200 A 1 AAC 1,000/1 ≤ 0.5 % P01120303 C106 0.1 A to 1,200 A 1 VAC 1 A / 1 mV ≤ 0.5 % P01120304 C107 0.1 A to 1,200 A 1 VAC 1 A / 1 mV ≤ 0.5 % P01120305 C112 1 mA to 1,200 A 1 AAC 1,000/1 ≤ 0.3 % P01120314 C113 1 mA to 1,200 A 1 AAC 1,000/1 ≤ 0.3 % P01120315 C116 1 mA to 1,200 A 1 VAC 1 A / 1 mV ≤ 0.3 % P01120316 C117 1 mA to 1,200 A 1 VAC 1 A / 1 mV ≤ 0.3 % P01120317 C122 1 A to 1,200 A 5 AAC 1,000/5 ≤ 1 % P01120306 C148
1 A to 300 A
1 A to 600 A
1 A to 1,200 A
5 AAC
1,000/5 ≤ 2 % ≤ 1 % ≤ 1 % P01120307 C160
0.1 A to 30 Apeak
0.1 A to 300 Apeak
1 A to 2,000 Apeak
3 Vcrête
2 Vcrête
10 A / 1 V
100 A / 1 V
1,000 A / 1 V
10 Hz …100 kHz
≤ 3 % ≤ 2 % ≤ 1 % P01120308 C173 1 mA to 1.2 A
0.01 A to 12 A
0.1 A to 120 A
1 VAC
1 A / 1 V
1,000 A / 1 V
10 Hz…3 kHz
≤ 0.7 % ≤ 0.5 % ≤ 0.3 % ≤ 0.2 % P01120309 B102 500 μA to 4 A
0.5 A to 400 A
4 VAC
0,4 VAC 1 mA / 1 mV
1 A / 1 mV 10 Hz…1 kHz
≤ 0.5 % 0.35 % P01120083 D30N 1 A to 3,600 A 1 AAC 3,000/1
30 Hz…5 kHz
≤ 0.5 % P01120049A D30CN 1 A to 3,600 A 1 AAC 3,000/1 ≤ 0.5 % P01120064 D31N
1 A to 1,800 A
1 AAC
1,000/1 1,500/1
30 Hz…1,5 kHz
≤ 3 % ≤ 1 % ≤ 0.5 % P01120050A D32N
1 A to 2,400 A
1 A to 3,600 A
1,000/1 2,000/1 3,000/1
30 Hz…1 kHz
≤ 1 % ≤ 0,5 % ≤ 0,5 % P01120051A D33N 1 A to 3,600 A 5 A AC 3,000/5 30 Hz…5 kHz ≤ 1 % P01120052A D34N 1,000/5 1,500/5 ≤ 3 % ≤ 1 % ≤ 0.5 % P01120053A D35N 1,000/5 2,000/5 3,000/5 ≤ 1 % ≤ 0.5 % ≤ 0.5 % P01120054A D36N 1 A to 3,600 A 3 AAC 3,000/3 ≤ 0.5 % P01120055A D37N
0.1 A to 36 A
1 A to 360 A
3 VAC
30 A/3 V
300 A/3 V
3,000 A/3 V ≤ 2 % P01120056A D38N
1 A to 90 Apeak
1 A to 900 Apeak
1 A to 9,000 Apeak
0,9 V crête 1 A / 0.1 mV
30 Hz…50 kHz ≤ 2 % P01120057A
(1) The upper value corresponds to 120 % of the max. rated value. (2) Reshaping of AC signal by diodes. 31 mm 111 mm 216 mm Ø 52 mm 310 mm 310 mm 48 mm 64 x 150 mm 43 mm 151 mm 312 mm Ø 115 mm max.
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 224 Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference 1 mA to 4.5 ADC 1 mA to 3 A RMS 1 mA to 4.5 APEAK
4.5 VAC
3 VRMS
4.5 Vpeak
(2) 1 mA / 1 mV DC…2 kHz ≤ 1 % P01120067A 100 μA to 450 mADC 100 μA to 300 mARMS 100 μA to 450 mAPEAK (2) 1 mA / 10 mV DC…1,5 kHz ≤ 1 % P01120074A E1N
0.05 A to 2 ADC
0.05 A to 1.5 AAC
0.5 A to 150 AAC/DC
2 VDC
1.5 VAC
DC… 2 kHz DC… 8 kHz ≤ 2 % ≤ 1,5 % P01120030A E3N
0.05 A to 10
0.05 A to 10 ADC
1 A to 100 Apeak
1 A to 100 ADC
1 Vpeak
1 A / 10 mV DC…100 kHz ≤ 3 %
≤ 4 % P01120043A E6N 5 mA to 2 ADC 5 mA to 1.5 AAC 20 mA to 80 AAC/DC
0.8 VAC/DC
DC… 2 kHz DC… 8 kHz ≤ 2 % ≤ 4 % P01120040A (1) The upper value corresponds to 120 % of the max. rated value. (2) Cable + electronic unit with Ø 4 mm safety plugs and 19 mm spacing for the K Series 15 mm 111 mm 25 mm Ø 3,9 mm 20 mm 67 mm 231 mm Ø 11,8 mm 49 mm 138 mm Ø 26 mm
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 225 Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference PAC10 0.5 A to 400 AAC
0.5 A to 600 ADC 600 mVAC/DC 1 A / 1 mV DC…5 kHz ≤ 2 % P01120070
0.2 A to 40 AAC
0.4 A to 60 ADC
0.5 A to 400 AAC
0.5 A to 600 ADC
1 A / 1 mV DC…10 kHz ≤ 1.5 % ≤ 2 % P01120068 PAC12
0.2 A to 60 Apeak
1 A / 1 mV DC…10 kHz ≤ 1.5 % ≤ 2 % P01120072 PAC20 0.5 A to 1,000 AAC
0.5 A to 1,400 ADC
1.4 V AC/DC 1 A / 1 mV DC…5 kHz ≤ 2 % P01120071
0.2 A to 100 AAC
0.4 A to 150 ADC
0.5 A to 1,000 AAC
1.4 VAC/DC 1 A / 10 mV
1 A / 1 mV DC…10 kHz ≤ 1.5 % ≤ 2.5 % P01120069 PAC22
0.2 A to 150 Apeak
0.5 A to 1,400 Apeak
1.5 Vpeak
1.4 Vpeak
1 A / 1 mV DC…10 kHz ≤ 1.5 % ≤ 2.5 % P01120073 (1) The upper value corresponds to 120 % of the max. rated value. (2) Cable + electronic unit with Ø 4 mm safety plugs and 19 mm spacing for the K Series 97 mm 224 mm Ø 30 mm ou 2 x Ø 24 mm 97 mm 236,5 mm Ø 42 mm ou 2 x Ø 25 mm ou 2 x (50 x 5) mm
MiniFlex® FLEXIBLE PROBES FOR AC CURRENT CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 226 600 V CAT IV 3 kAAC1000 V CAT III 4 calibres80 mA IP MA110 - MA130 - MA200 STRENGTHS Q Flexible sensor comprising an active part (Rogowski coil) and a unit containing electronics Q For multimeters, loggers, oscilloscopes, etc. Q No magnetic saturation constraints: excellent linearity, low phase shift, wide dynamic range for measurement Q Flexibility of the sensors for easier clamping of the conductor to be measured Q Compact instruments which are easy to position in residential or industrial electrical cabinets Q Click system for opening and closing the core even when handling with safety gloves Q MA110 delivered with 2 x 1.5V LR6 alkaline batteries, 1 safety datasheet, 1 verification certificate Q MA130 with 2 x 1.5V LR6 alkaline batteries, 1 safety datasheet, 1 verification certificate, 1 set of cloured rings for cable foolproofing/ identification, 3 female BNC /Ø 4 mm male plug adapters Q MA200 delivered with one 9 V battery, 1 verification certificate ADDITIONAL INFO MA110 model Q Measurement from 80 mA Q Can be connected to the AC voltage input (mVAC / VAC) of any multimeter or measuring instrument equipped with Ø 4 mm female banana plugs Q Can be powered by batteries or via a standard external power supply Q Equipped with an automatic power-off system which can be deactivated at start-up to perform long-duration measurement campaigns Q Possesses 3 LEDs (green, yellow and orange) indicating, respectively, the power-supply status, status of the automatic power-off function and measurement capacity overruns Three-phase MA130 model Q Can be connected to the AC voltage inputs (mVAC / VAC) of any power analyser, logger or measuring instrument equipped with BNC plugs Three-phase MA200 model Q Equipped with a BNC output and can be connected to all types of oscilloscopes Q Offers high bandwidth Q Particularly suitable for viewing transient signals, command signals, tripping currents of thyristors or the output signal from an electronic power supply
MiniFlex® FLEXIBLE PROBES FOR AC CURRENT CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 227 (1) The upper value corresponds to 120 % of the max. rated value. (2) Cable + electronic unit with Ø 4 mm safety plugs and 19 mm spacing. Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference OFF 3 A 30 A 300 A 3000 A
3 A : 1000 mV / A
30 A : 100 mV / A
300 A : 10 mV / A
3000 A : 1 mV / A
P MA110 3-30-300-3000/3 (17 cm / Ø 4.5 cm)
0.08 A - 3 A
0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A
3 VAC (2)
1 V/A
10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120660 MA110 3-30-300-3000/3 (25 cm / Ø 7 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120661 MA110 3-30-300-3000/3 (35 cm / Ø 10 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120662 OFF 30 A 300 A 3000 A P MA130 30-300-3000/3 (25 cm / Ø 7 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120663 MA200 30-300/3 (17 cm / Ø 4.5 cm)
0.5 A…45 APEAK
0.5 A…450 APEAK 4.5 VPEAK 100 mV/A 10 mV/A
5 Hz…1 MHz
≤ 1 % + 0.3 A P01120570 MA200 30-300/3 (25 cm / Ø 7 cm) 0.5 A…450 APEAK 4.5 VPEAK 100 mV/A 10 mV/A ≤ 1 % + 0.3 A P01120571 MA200 3000 /3 (35 cm / Ø 10 cm) 0.5 A…4,500 APEAK 4.5 VPEAK 1 mV/A ≤ 1 % + 0.3 A P01120572
AmpFlex® FLEXIBLE PROBES FOR AC CURRENT CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 228 30 kAAC1000 V CAT IV IP 6780 mA 4 calibres STRENGTHS Q Flexible sensor comprising an active part (Rogowski coil) and a unit containing electronics Q For multimeters, loggers, oscilloscopes, etc. Q No magnetic saturation constraints: excellent linearity, low phase shift, wide dynamic range for measurement Q Flexibility of the sensors for easier clamping of the conductor to be measured Q Compact instruments which are easy to position in residential or industrial electrical cabinets Q Click system for opening and closing the core even when handling with safety gloves Q A110 delivered with 2 x 1.5V LR6 alkaline batteries, 1 safety datasheet, 1 verification certificate Q A130 delivered with 2 x 1.5V LR6 batteries, 1 datasheet, 1 verification certificate, 1 set of coloured rings for cable foolproofing/ identification, 3 female BNC/Ø 4 mm male plug adapters ADDITIONAL INFO A110 model QMeasures from 80 mA Q Can be connected to the AC voltage input (mVAC / VAC) of any multimeter or measuring instrument equipped with Ø 4 mm female banana plugs Q Can be powered by batteries or via a standard external power supply Q Equipped with an automatic power-off system which can be deactivated at start-up to perform long-duration measurement campaigns Q Possesses 3 LEDs (green, yellow and orange) indicating, respectively, the power-supply status, status of the automatic power-off function and measurement capacity overruns Three-phase A130 model Q Can be connected to the AC voltage inputs (mVAC / VAC) of any power analyser, logger or measuring instrument equipped with BNC plugs Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference OFF 3 A 30 A 300 A 3000 A P A110 3-30-300-3,000/3 (45 cm / Ø 14 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120630 A110 3-30-300-3,000/3 (80 cm / Ø 25 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 10 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120631 A110 30-300-3000-30,000/3 (120 cm / Ø 38 cm)
0.5 A - 30 A
0.5 A .. 300 A 0.5 A .. 3,000 A 0.5 A .. 30,000 A 3 V AC (2) 100 mV/A 10 mV/A 1 mV/A 0.1 mV/A 10 Hz .. 5 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120632 OFF 30 A 300 A 3000 A P A130 30-300-3,000/3 (80 cm / Ø 25 cm) 0.5 A .. 30 A 0.5 A .. 300 A 0.5 A .. 3,000 A 10 Hz .. 20 kHz 10 Hz .. 20 kHz 10 Hz .. 20 kHz ≤ 1% P01120633 A110 - A130 (1) The upper value corresponds to 120 % of the max. rated value. (2) Cable + electronic unit with Ø 4 mm safety plugs and 19 mm spacing.
SPECIFIC SENSORS FOR DEDICATED APPLICATIONS CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 229 (1) The upper value corresponds to 120 % of the max. rated value. (2) Cable + electronic unit with Ø 4 mm safety plugs and 19 mm spacing. Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm Female sockets ø 4 mm Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference LEAKAGE CURRENT MEASUREMENT MN73 10mA to 2.4 A 100 mA to 240 A
1 A / 1,000 mV
1 A / 10 mV 40 Hz to 10 kHz ≤ 1 %
≤ 2 % P01120421 C173 1 mA to 1.2 A 1,000 A / 1 V
10 Hz to 3 kHz
≤ 0.7 % ≤ 0.3 % ≤ 0.5 % ≤ 0.2 % P01120309 B102 500 μA to 4 A
0.4 VAC
1 A / 1 mV 10 Hz to 1 kHz ≤ 0.5 % ≤ 0.35 % P01120083 PROCESS CURRENT MEASUREMENT 1 mA to 4.5 ADC 1 mA to 3 ARMS 1 mA to 4.5 APEAK (2)
4.5 VDC
1 mA / 1 mV DC to 2 kHz ≤ 1 % P01120067A 100 μA to 450 mADC 100 μA to 300 mARMS 100 μA to 450 mAPEAK (2) 1 mA / 10 mV DC to 1.5 kHz ≤ 1 % P01120074A MEASUREMENT ON CURRENT TRANSFORMER SECONDARY MN71 10 mA to 12 A 1 VAC 1 A / 100 mV 40 Hz to 10 kHz ≤ 1 % P01120420 Please contact us for models with specific sensitivities (mV/A) and/or lengths. We can also supply bare sensors for integration into assemblies including the signal-processing electronics.
CURRENT PROBES FOR OSCILLOSCOPES CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 230 *Reference for E3N + power supply > P01120047(1) The upper value corresponds to 120 % of the max. rated value. QView the currents in total safety without opening the circuit! QCapture the signal simply by clamping the conductor 600 V CAT III IEC 61010-2-32 ADDITIONAL INFO Input Output - Connections Specific features Measurement range(1) Current Voltage Lead + safety plugs ø 4 mm Female sockets ø 4 mm BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Very low current Low current Medium current High current Alternating current Direct currentSeries Model Reference MEASUREMENT ON OSCILLOSCOPE MN60 0.1 A to 60 APEAK
0.5 A to 600 APEAK 6 VPEAK 1 A / 100 mV
1 A / 10 mV 40 Hz to 40 kHz ≤ 2 %
≤ 1.5 % P01120409 Y7N 1 A to 1,200 APEAK 1.2 VPEAK 1 mA / 1 mV 5 Hz to 10 kHz ≤ 2 % P01120075 C160
1 A to 300 APEAK
3 VPEAK
2 VPEAK
1,000 A / 1 V
10 Hz to 100 kHz
≤ 3 % ≤ 2 % ≤ 1 % P01120308 D38N
0.9 VPEAK
1 A / 10 V
1 A / 0.1 mV
30 Hz to 50 kHz ≤ 2 % P01120057A
(17 cm) 0.5 A…450 APEAK 4.5 VPEAK 100 mV/A 10 mVA ≤ 1 % + 0.3 A P01120570 MA200 30-300/3 (25 cm) 0.5 A…45 APEAK 4.5 VPEAK 100 mV/A 10 mVA ≤ 1 % + 0.3 A P01120571 MA200 3000/3 (35 cm) 5 A…4,500 APEAK 4.5 VPEAK 1 mV/A ≤ 1 % + 0.3 A P01120572 E3N 0.05 A to 10 APEAK
1 A to 100 APEAK 1 VPEAK 1 A / 10 mV
1 A / 1 mV DC to 10 kHz ≤ 3 %
≤ 4 % P01120043A P01120047* PAC12 1 A / 1 mV DC to 100 kHz ≤ 1.5 % ≤ 2 % P01120072 PAC22 1 A / 1 mV DC to 10 kHz ≤ 1.5 % ≤ 2.5 % P01120073
ACCESSORIES / REPLACEMENT PARTS CURRENT MEASUREMENT 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 231 MiniFlex® MA110/MA130 and AmpFlex® A110/A130 - 110 V-240 V 50/60 Hz - Female USB type A 5 V 1A - Charging and connection cable - Male USB type A - male USB type Micro-B - 1.80 m MH60 MN73 / C173 / B102 OTHER CURRENT SENSORS FOR CURRENT SENSORS FIND ALL OUR ACCESSORIES ON PAGE 230 AN1 artificial neutral box
Protection, storage and transport 232 Connections 238 Adapters and probes 242 Fuses 243
PROTECTION, STORAGE & TRANSPORT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 234 SOFT CASES BAGS SHOULDER BAGS HARD CASES WATERPROOF SITE CASESMOUNTING SUPPORT E01 E05 E02 E06 E03 E07 E04 E08 M01-M02-M03 S20 S01 S06 S02 S07 S03 S08 S04 S09 S05 S10 S21 S22 S23 M04-M05-M06 M07 B01F01 B02
PROTECTION, STORAGE AND TRANSPORT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 235 Photo L x H x W Reference Additional information SOFT CASE E01 110 x 220 x 45 mm P01298065Z E02 125 x 210 x120 mm P01298049 Specific to one instrument or product range. See pages 234 E03 125 x 265 x 60 mm P01298043Z E04 180 x 75 x 45 mm P01298012 E05 185 x 135 x 85 mm P01298046 Specific to one instrument or product range. See pages 234 E06 190 x 250 x 60 mm P01298055 E07 250 x 190 x 80 mm P01298051 E08 70 x 185 x 30 mm P01298007 BAG S01 120 x 200 x 60 mm P01298074 Compatible with MultiFix S02 120 x 245 x 60 mm P01298075 Compatible with MultiFix S03 120 x 320 x 60 mm P01298076 Compatible with MultiFix S04 150 x 230 x (40+40) mm P01298032 S05 165 x 250 x 60 mm P06239502 S06 180 x 220 x 75 mm P01298036 S07 225 x 270 x 70 mm P01298033 S08 240 x 140 x 130 mm P01298006 S09 355 x 255 x 235 mm P01298056 S10 360 x 200 x 140 + 360 x 160 x 35 mm P01298061A SHOULDER BAG S20 330 x 240 x 240 mm P01298078 S21 380 x 280 x 200 mm P01298066 All-terrain waterproof bottom. 2 compartments and space for documents. Supplied with shoulder strap S22 575 x 320 x (200 + x +x) mm P01298067 S23 P01298031 HARD CASE M01 270 x 195 x 65 mm P01298071 Equipped with foam inserts. Delivered with strap and keys M02 285 x 210 x 80 mm P01298037 Specific to one instrument or product range. See pages 234 M03 285 x 210 x 80 mm P01298037A Specific to one instrument or product range. See pages 234 M04 320 x 255 x 75 mm P01298004 Equipped with foam inserts. Delivered with strap and keys M05 320 x 255 x 75 mm P01298011 Specific to one instrument or product range. See pages 234 M06 320 x 255 x 75 mm P01298040 Specific to one instrument or product range. See pages 234 M07 440 x 310 x 135 mm P01298072 Equipped with foam inserts. Delivered with strap and keys WATERPROOF CASE B01 272 x 248 x 130 mm P01298068 Equipped with foam inserts B02 272 x 248 x 182 mm P01298069 Equipped with foam inserts MULTIFIX MOUNTING ACCESSORY P01102100Z REELING BOX P01102149 When used with the compatible soft cases and bags, this helps you to transport and mount the measuring instruments for greater user comfort. To make sure that your cables are never tangled. Can be used to store up to 3 m of cable (1 x 3 m / 2 x 1.5 m). Built-in magnet for easy mounting on any metal surface.
CHOOSE THE RIGHT PROTECTION FOR YOUR INSTRUMENT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 236 Mounting acc. Soft case Bag Bag Photo no. F01 E01 E02 E03 E04 E05 E06 E07 E08 S01 S02 S03 S04 S05 S06 S07 S08 S09 Code P01102100Z P01298065Z P01298049 P01298043Z P01298012 P01298012Z P01298046 P01298055 P01298051 P01298007 P01298074 P01298075 P01298076 P01298032 P06239502 P01298036 P01298033 P01298006 P01298056 AL834 AN1 artificial neutral box C.A 1052 C.A 1621, C.A 1623, C.A 1631 C.A 1725, C.A 1727 C.A 1864, C.A 1866 C.A 1877, C.A 1878, C.A 1882 C.A 40 C.A 406, C.A 406 KIT C.A 41, C.A 43 C.A 5001, C.A 5003, C.A 5005 C.A 5005 C.A 5011 C.A 5030 C.A 5110, C.A 5120 C.A 5205G/10G/20G/30G/40G/60G C.A 5231, C.A 5233 C.A 5271, C.A 5273, C.A 5275, C.A 5277 C.A 5287, C.A 5289 C.A 6030 C.A 61, C.A 65 C.A 6113, C.A 6116, C.A 6116N, C.A 6117 C.A 6115N C.A 6121 C.A 6160 C.A 6240, C.A 6250, C.A 6255 C.A 6416, C.A 6417 C.A 6421, C.A 6423 C.A 6425 C.A 6454, C.A 6456 C.A 6460, C.A 6462 C.A 6501, C.A 6503 C.A 6505 C.A 6511, C.A 6513 C.A 6521, C.A 6523, C.A 6525 C.A 6522/24/26, C.A 6532/34/36 C.A 6531, C.A 6533 C.A 6541, C.A 6543 C.A 6545, C.A 6547
CHOOSE THE RIGHT PROTECTION FOR YOUR INSTRUMENT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 237 Sheath Shockproof sheath Hard case Bag Strap M02 M03 M04 M05 M06 M02 M07 S20 S21 S22 S23 Photo no. P01298015 P01298009B P01298016 P03298504 P01298037 P01298037A P01298004 P01298011 P01298040 P01298080 P01298072 P01298078 P01298066 P01298067 P01298031 P01298057 P01298005 Code AL834 AN1 artificial neutral box C.A 1052 C.A 1621, C.A 1623, C.A 1631 C.A 1725, C.A 1727 C.A 1864, C.A 1866 C.A 1877, C.A 1878, C.A 1882 C.A 40 C.A 406, C.A 406 KIT C.A 41, C.A 43 C.A 5001, C.A 5003, C.A 5005 C.A 5005 C.A 5011 C.A 5030 C.A 5110, C.A 5120 C.A 5205G/10G/20G/30G/40G/60G C.A 5231, C.A 5233 C.A 5271, C.A 5273, C.A 5275, C.A 5277 C.A 5287, C.A 5289 C.A 6030 C.A 61, C.A 65 C.A 6113, C.A 6116, C.A 6116N, C.A 6117 C.A 6115N C.A 6121 C.A 6160 C.A 6240, C.A 6250, C.A 6255 C.A 6416, C.A 6417 C.A 6421, C.A 6423 C.A 6425 C.A 6454, C.A 6456 C.A 6460, C.A 6462 C.A 6501, C.A 6503 C.A 6505 C.A 6511, C.A 6513 C.A 6521, C.A 6523, C.A 6525 C.A 6522/24/26, C.A 6532/34/36 C.A 6531, C.A 6533 C.A 6541, C.A 6543 C.A 6545, C.A 6547
CHOOSE THE RIGHT PROTECTION FOR YOUR INSTRUMENT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 238 Mounting acc. Soft case Bag Bag Photo no. F01 E01 E02 E03 E04 E05 E06 E07 E08 S01 S02 S03 S04 S05 S06 S07 S08 S09 Code P01102100Z P01298065Z P01298049 P01298043Z P01298012 P01298012Z P01298046 P01298055 P01298051 P01298007 P01298074 P01298075 P01298076 P01298032 P06239502 P01298036 P01298033 P01298006 P01298056 C.A 6550, C.A 6555 C.A 702, C.A 703 C.A 704 C.A 730, C.A 735 C.A 745 C.A 740, C.A 760, C.A 740N, C.A 740N IP2X, C.A 760N, C.A 760N IP2X C.A 742, C.A 742 IP2X, C.A 762, C.A 762 IP2X C.A 745N, C.A 755, C.A 757 C.A 771, C.A 771 IP2X, C.A 773, C.A 773 IP2X C.A 8220, C.A 8230 C.A 8336 C.A 8352 C.A 8435 C.A 871, C.A 879 CADI 2 CDA 104 DTR 8510 F01, F03, F05, F07, F09 F11N, F13N, F15 F201, F203, F205 F21 F3N F401, F403, F405, F407 F601, F603, F605, F607 F62, F65 FTV200 L101, L102, L111, L261, L322, L481, L562, L642, ML912 L452 MA400D, MA4000D MAN'X 015, MAN'X 02S MAN'X TOP, MAN'X TOP PLUS MAX 2000, MAX 3000 PAC10, PAC11, PAC12 PAC20, PAC21, PAC22 PEL102, PEL103 PEL105 RW501, RW511, RW521, RW5012 SIMPLE LOGGER ML914, AL834 TK 1000 TP 850
CHOOSE THE RIGHT PROTECTION FOR YOUR INSTRUMENT ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 239 Sheath Shockproof sheath Hard case Bag Strap M02 M03 M04 M05 M06 M02 M07 S20 S21 S22 S23 Photo no. P01298015 P01298009B P01298016 P03298504 P01298037 P01298037A P01298004 P01298011 P01298040 P01298080 P01298072 P01298078 P01298066 P01298067 P01298031 P01298057 P01298005 Code C.A 6550, C.A 6555 C.A 702, C.A 703 C.A 704 C.A 730, C.A 735 C.A 745 C . A 7 6 0 N I P 2 X C.A 742, C.A 742 IP2X, C.A 762, C.A 762 IP2X C.A 745N, C.A 755, C.A 757 C.A 771, C.A 771 IP2X, C.A 773, C.A 773 IP2X C.A 8220, C.A 8230 C.A 8336 C.A 8352 C.A 8435 C.A 871, C.A 879 CADI 2 CDA 104 DTR 8510 F01, F03, F05, F07, F09 F11N, F13N, F15 F201, F203, F205 F21 F3N F401, F403, F405, F407 F601, F603, F605, F607 F62, F65 FTV200 L101, L102, L111, L261, L322, L481, L562, L642, ML912 L452 MA400D, MA4000D MAN'X 015, MAN'X 02S MAN'X TOP, MAN'X TOP PLUS MAX 2000, MAX 3000 PAC10, PAC11, PAC12 PAC20, PAC21, PAC22 PEL102, PEL103 PEL105 RW501, RW511, RW521, RW5012 SIMPLE LOGGER ML914, AL834 TK 1000 TP 850
Ø 4 MM BANANA CONNECTION TECHNOLOGY ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 240 Model Description Model Description Set of 2 red/black moulded PVC leads P01295450Z Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm
- 15 A
- 1.5 m
- 1000 V CAT IV Set of 2 red/black moulded PVC leads P01295451Z Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm
- 15 A
- 1.5 m
- 1000 V CAT IV Set of 2 red/black moulded silicone leads P01295452Z Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm
- 15 A
- 1.5 m
- 1000 V CAT IV Set of 2 red/black moulded PVC leads P01295453Z Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm
- 15 A
- 1.5 m
- 1000 V CAT IV Model Description Model Description Set of 2 red/black PVC test-probe leads P01295455Z Insulated straight male plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV / 1000 V CAT III Set of 2 red/black PVC test-probe leads P01295456Z Insulated elbowed male plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV / 1000 V CAT III Set of 2 IP2X PVC leads for multimeters P01295461Z Complies with NF C 18-510 and IEC 61010-031+A1:2008
- IP2X test probe
- Insulated elbowed male plug Ø 4 mm
- 15 A
- 1,5 m
- 600 V CAT IV Model Description Model Description Set of 2 red/black PVC leads P01295288Z Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV / 1000 V CAT III Set of 2 red/black PVC leads P01295289Z Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV / 1000 V CAT III Set of 2 red/black PVC leads P01295290Z Insulated straight male plug Ø 4 mm with rear connection. Insulated straight male plug Ø 4 mm with rear connection
- 20 A
- 2 m
- 600 V CAT III Moulded For CAT IV & CAT III installations Standards MEASUREMENT LEADS LEADS WITH TEST PROBES
Ø 4 MM BANANA CONNECTION TECHNOLOGY ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 241 Model Description Model Description Set of 2 moulded test probes Ø 4 mm P01295458Z
- Female plug Ø 4 mm
- 15 A
- CAT II 300 V Set of 2 moulded test probes Ø 2 mm P01295460Z
- Female plug Ø 4 mm
- 15 A
- CAT II 300 V For CAT IV & CAT III installations For CAT II & lower installations Model Description Model Description Measurement leads + test probes kit P01295475Z comprising: Set of 2 red/black PVC leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm
- 15 A
- 1,5 m
- 600 V CAT IV / 1000 V CAT III + Set of 2 moulded test probes Ø 4 mm
- Female plug Ø 4 mm
- CAT II 300 V Measurement leads + test probes kit P01295474Z comprising: Set of 2 red/black PVC leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV / 1000 V CAT III + Set of 2 moulded test probes Ø 2 mm
- Female plug Ø 4 mm
- CAT II 300 V For CAT II & lower installations LEADS WITH TEST PROBES REMOVABLE TEST PROBES Model Description Model Description Set of 2 red/black moulded test probes P01295454Z
- Female plug Ø 4 mm
- 15 A
- CAT IV / CAT III 1000 V Set of 2 red / black moulded Ø 2 test probes P01295491Z
- Ø 4 mm female plug
- 10 A
- CAT IV 1000 V
PRODUCT-SPECIFIC ACCESSORIES ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 242 Model Description Red test probe Ø 4 mm P01103060Z removable for tester or DMM Use as "hands-free" test probe
- Male plug Ø 4 mm
- 600 V CAT IV Model Description Red test probe Ø 4 mm P01103061Z removable with locking pin For tester or remote-control probe
- Male plug Ø 4 mm
- 600 V CAT IV FOR MULTIMETERS OR TESTERS WITH + TERMINAL ON TOPFOR C.A 745 TESTER OR REMOTE-CONTROL PROBE Model Description Removable red test probe P01103059Z
- Female plug Ø 4 mm
- 600 V CAT IV Black test-probe lead P01295464Z Insulated elbowed female plug Ø 4 mm Length 0.85 m
- 600 V CAT IV FOR C.A 704, C.A 740 & C.A 760 VOLTAGE ABSENCE TESTERS Model Description Set of red/black test probes P01102152Z
- CAT III/IV Set of red/black test probes P01102153Z
- Ø 2 mm
- CAT II Set of red/black test probes P01102154Z
- Ø 4 mm
- CAT II FOR C.A 745N, C.A 755 AND C.A 757 FOR C.A 771 & C.A 773 VOLTAGE ABSENCE TESTERS Model Description Model Description Set of 2 red/black IP2X test probes Ø 4 mm P01102128Z Female plug Ø 4 mm IEC 61423-3 1000 V Set of 2 red/black test probes Ø 2 mm with crystal cap P01102124Z Female plug Ø 4 mm IEC 61423-3 1000 V Set of 2 red/black IP2X test probes P01102127Z Female plug Ø 4 mm
Set of 2 red/black test probes Ø 4 mm P01102125Z Female plug Ø 4 mm IEC 61423-3 1000 V Set of 2 red/black test probes P01102123Z Female plug Ø 4 mm FOR ALL VOLTAGE ABSENCE TESTERS, C.A 74X/XN SERIES / C.A 76X/XN SERIES Model Description Model Description Set of 2 PVC IP2X leads P01295463Z for C.A 760 and C.A 704 VATs Complies with NF C 18-510 and IEC 61010-031+A1:2008
- IP2X test probe Ø 2 mm
- Elbowed female plug Ø 4 mm
- 15 A
- 1.5 m
- 600 V CAT IV Set of 2 IP2X leads for C.A 740N and C.A 760N VATs P01295462Z
- IP2X test probe Ø 4 mm
- Elbowed female plug Ø 4 mm
- 15 A
- NF C 18-510 / IEC 61243-3 1000 V
- 1.5 m P01295285Z Red removable test probe P01102008Z
- Female plug Ø 4 mm
- IEC 61243-3 Black test-probe lead P01102009Z Insulated elbowed female plug Ø 4 mm
- Length 0.85 m
- IEC 61243-3 Set of IP2X accessories for VAT P01102121Z
- 2 x IP2X Ø 4 mm test probes
- 1 point-point cable, L = 1.10 m C.A 751 measurement adapter P01101997Z
- For 2P+E sockets
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 243 FOR CAT IV & CAT III INSTALLATIONS FOR CAT II & LOWER INSTALLATIONS Model Description Model Description Set of 2 red/black crocodile clips P01295457Z
- 15 A
- 1000 V CAT IV Set of 2 red/black crocodile wire grips P01102053Z
- 20 A
- 1000 V CAT III Set of leads and measuring accessories for electricians P01295459Z
- 2 x 1000 V CAT IV moulded test probes
- 2 x 1.5 m 1000 V CAT IV red/black moulded leads with straight male plug – elbowed male plug
- 2 x red/black 1000 V CAT IV crocodile clips
- 2 x 300 V CAT II moulded test probes Ø 4 mm Set of 2 adapters P01102101Z Insulated female BNC plug–Red/black insulated male plugs Ø 4 mm with 19 mm spacing
- 600 V CAT III Kit of 2 PVC leads + 2 test probes Ø4 mm P01295475Z
- Straight male plug Ø4 mm - Elbowed male plug Ø4 mm
- Probe Ø4 mm - Female plug Ø 4mm
- 300 V CAT II Kit of 2 PVC leads + 2 test probes Ø2 mm P01295474Z
- Straight male plug Ø4 mm - Elbowed male plug Ø4 mm
- Probe Ø2 mm - Female plug Ø 4mm
- 300 V CAT II Set of 2 red/black magnetized test probes P01103058Z For voltage measurement only Ø test probe: 6.6 mm – Elbowed female plug Ø 4 mm
- 1000 V CAT III / 600 V CAT IV PVC lead AG-1066Z Insulated male BNC plug –Insulated straight male banana plugs Ø 4 mm (red/black) with rear connection
- 1 m
- 500 V CAT III Model Description Model Description Set of 3 measurement adapters for housing P01102114Z 2 red/black insulated straight male plugs Ø4 mm
- E27 screw socket
- B22 bayonet socket
- 2-pole mains socket (P/N)
- 250 V CAT II C.A 753: Measurement adapter for 2P+E socket P01191748Z
- Suitable for European and Schuko sockets
- Can be used for measurements on the P (Phase), N (Neutral) and PE (Earth) conductors in total safety
- Guarantees mechanical and electrical contact with all test probes (Ø2, Ø4, IP2x, etc.)
- Shows the presence of a P-N voltage (> 200 V) and indicates the phase position
- IEC 61010 230 V CAT II Current lead equipped with a French 2P+E mains socket P03295509
- For inserting an ammeter in series in total safety
- For measuring the current with a current clamp without having to remove the outer sheath of the power supply cable Measurement lead for French and German 2P+E mains sockets P06239307 For direct measurement on a mains socket Quick implementation and reliable connections Set of 2 red/black insulation-piercing clips P01102055Z
- 30 V AC, 60 V DC CMS clamp HX0064 Copper-gold-plated beryllium contacts Output via male plugs Ø 4 mm
- 1.2 m
- SELV Set of 2 adapters P01101846 Red/black insulated male BNC – female sockets Ø 4 mm with 19 mm spacing
- 500 V CAT I, 150 V CAT III Set of 2 adapters P01101847 Red/black insulated BNC male – male sockets Ø 4 mm with 19 mm spacing
- 500 V CAT I, 150 V CAT III
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 244 TEMPERATURE AND ROTATION SPEED MEASUREMENT PROBES Model Description Model Description C.A 1711 P01102082 Tachometer probe - Pulse output 1,1 V 0 / rev. - 2 insulated banana plugs Ø 4 mm - Measurement range: 6 to 120,000 RPM - IP 53 C.A 1871 P01651610Z Infrared sensor Compatible with any multimeter equipped with an mV range - Measurement range: -30 °C to +550 °C - Output: 1 mV/1 °C - Distance/spot ratio: 8/1 - Accuracy: ± 2 % C.A 801 P01652401Z Temperature adapter for multimeters - 1 mVDC / °C (or /°F) Delivered with 1 K sensor and 1 battery C.A 803 P01652411Z Temperature adapter for multimeters - 2 measurement channels - 1 mVdc / °C (or /°F) - θ1 - θ2 differential measurement Delivered with 2 K sensors and 1 battery ADAPTERS FOR TEMPERATURE MEASUREMENT SENSORS Modèle Description Modèle Description Set of 2 safety thermocouple adapters for multimeters P01102106Z Female thermocouple plug – insulated red/black male plugs Ø 4 mm with 19 mm spacing Pt100/Pt1000 sensor adapter for multimeters HX0091 Female Pt100/Pt1000 plug – Red/black insulated male plugs Ø 4 mm Safety adapter and K-sensor temperature probe P01102107Z For multimeters and multimeter clamps equipped with a temperature measurement calibre with 19 mm-spaced banana inputs - Measurement range from -50 °C to +350 °C - Sensor length: approx. 100 cm FOR CAT II & LOWER INSTALLATIONS Modèle Description SHT40KV high-voltage probe for multimeters P01102097 Maximum rated voltage: 40 kV DC, 28 kVRMS or 40 kVPEAK (50/60 Hz) Division ratio (input/output : 1 kV / 1 V For multimeters with 10 MΩ input impedance EXTERNAL POWER SUPPLY & MAINS POWER PACK Model Description Model Description Set of 4 x 1.5 V LR06 rechargeable batteries with low self-discharge plus charger HX0053
230 V / μUSB mains adapter – B
- 110 – 240 V 50/60 Hz
- Female USB type A, 5 V 1 A Charging and connection cable
- Male USB type A – Male USB type μ-B
- 1.8 m Set of 4 x 1.5 V LR06 rechargeable batteries with low self-discharge HX0051B
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 245 Produit Dimensions standardisées (mm) Ampérage Référence Produit Dimensions standardisées (mm) Ampérage RéférenceProduct Standardized dimensions (mm) Amperage Reference Product Standardized dimensions (mm) Amperage Reference C.A 10 6 x 32 8 A P01297013 C.A 6115N 5 x 20 2 A P01297026 C.A 1621 5 x 20 125 mA P01297099 C.A 6115N 6 x 32 3.15 A P01297080 C.A 1631 5 x 20 125 mA P01297099 C.A 6121 5 x 20 1 A P01297031 C.A 401 6 x 32 1 A P03297507 C.A 6121 5 x 20 4 A P01297032 C.A 401 6 x 32 10 A P03297510 C.A 6121 6 x 32 0.2 A P01297033 C.A 4010 6 x 32 0.315 A P03297509 C.A 6121 10 x 38 20 A P01297030 C.A 4010 6 x 32 16 A P03297505 C.A 6160 6 x 32 16 A P01297086 C.A 4020 6 x 32 0.315 A P03297509 C.A 6160 5 x 20 2.5 A P01297085 C.A 4020 6 x 32 16 A P03297505 C.A 6240 6 x 32 12.5 A P01297091 C.A 403 6 x 32 0.315 A P03297509 C.A 6250 5 x 20 2 A P01297090 C.A 404 6 x 32 1.25 A P01297015 C.A 6250 6 x 32 16 A P01297089 C.A 405 6 x 32 6.3 A P01297016 C.A 6255 5 x 20 2 A P01297090 C.A 406 5 x 20 0.16 A P03297508 C.A 6255 6 x 32 16 A P01297089 C.A 406 6 x 32 3.15 A P01100726 C.A 6421 6 x 32 0.1 A P01297012 C.A 4300 6 x 32 1 A P03297507 C.A 6423 6 x 32 0.1 A P01297012 C.A 4300 6 x 32 10 A P03297510 C.A 6425 6 x 32 0.1 A P01297012 C.A 47 5 x 20 1 A P01297075 C.A 6460 6 x 32 0.1 A P01297012 C.A 47 5 x 20 4 A P01297076 C.A 6462 6 x 32 0.1 A P01297012 C.A 47 5 x 20 0.315 A P01297074 C.A 6470 5 x 20 0.63 A AT0094 C.A 5000 6 x 32 5 A P01297035 C.A 6472 5 x 20 0.63 A AT0094 C.A 5000 6 x 32 0.5 A P01297028 C.A 6501 6 x 32 0.2 A P01297095 C.A 5003 6 x 32 1.6 A P01297036 C.A 6503 6 x 32 0.2 A P01297095 C.A 5003 10 x 38 16 A P01297037 C.A 6511 6 x 32 1.6 A P01297022 C.A 5005 6 x 32 1 A P01297039 C.A 6513 6 x 32 1.6 A P01297022 C.A 5005 6 x 32 10 A P01297038 C.A 6521 6 x 32 0.63 A P01297078 C.A 5011 6 x 32 1 A P01297039 C.A 6523 6 x 32 0.63 A P01297078 C.A 5011 6 x 32 10 A P01297038 C.A 6525 6 x 32 0.63 A P01297078 C.A 5110 6 x 32 1 A P03297507 C.A 6531 6 x 32 0.63 A P01297078 C.A 5120 6 x 32 1 A P03297507 C.A 6541 6 x 32 0.1 A P01297072 C.A 5120 6 x 32 10 A P03297510 C.A 6541 8 x 50 2.5 A P01297071 C.A 5210 10 x 38 12 A P01297021 C.A 6543 6 x 32 0.1 A P01297072 C.A 5210 6 x 32 0.4 A P01297020 C.A 6543 8 x 50 2.5 A P01297071 C.A 5210G 10 x 38 12 A P01297021 C.A 6545 5 x 20 0.1 A P03297514 C.A 5210G 6 x 32 0.4 A P01297020 C.A 6547 5 x 20 0.1 A P03297514 C.A 5220 10 x 38 12 A P01297021 C.A 6549 5 x 20 0.1 A P03297514 C.A 5220 6 x 32 0.4 A P01297020 CADI 2 5 x 20 12.5 A P01297004 C.A 5220G 10 x 38 12 A P01297021 CADI 2 5 x 20 3.15 A P01297002 C.A 5220G 6 x 32 0.4 A P01297020 CAMPUS 5 x 20 0.16 A P03297508 C.A 5230G 10 x 38 12 A P01297021 CAMPUS 6 x 32 3.15 A P01100726 C.A 5230G 6 x 32 0.5 A P01297028 CdA 651 6 x 32 3.15 A P01100726 C.A 5240G 10 x 38 12 A P01297021 CdA 651M 6 x 32 3.15 A P01100726 C.A 5233 6 x 32 10 A AT0070 CdA 778N 6 x 32 2 A P03297513 C.A 5240G 6 x 32 0.5 A P01297028 CdA 778N 6 x 32 10 A P03297502 C.A 5260G 6 x 32 0.1 A P01297012 CdA 791 8 x 32 6 A P03100801 C.A 5271 10 x 38 10 A P01297096 CdA 800 5 x 20 0.1 A P03100201 C.A 5273 10 x 38 10 A P01297096 CdA LAB'X 9000 5 x 20 1.6 A P03297501 C.A 5275 6 x 32 0.63 A P01297098 CdA100-A 6 x 32 0.4 A P01297020 C.A 5275 10 x 38 10 A P01297096 CONPAMATIC 2 10 x 38 10 A P01100731 C.A 5277 6 x 32 0.63 A P01297098 CONPAMATIC 2 6 x 32 3.15 A P01100726 C.A 5277 10 x 38 10 A P01297096 DETEC 220 5 x 20 0.315 A P01297014 C.A 5287 10 x 38 11 A P01297092 DTR 8500 5 x 20 1 A P01297031 C.A 5287 10 x 38 0.44 A P01297094 DTR 8500 5 x 20 4 A P01297041 C.A 5289 10 x 38 11 A P01297092 DTR 8500 5 x 20 0.5 A P01297042 C.A 5289 10 x 38 0.44 A P01297094 IMEG 500 5 x 20 0.2 A P02297302 C.A 6114 / 15N 6 x 32 3.15 A P01297080 IMEG 500N 5 x 20 0.2 A P02297302
standardisées (mm) Ampérage Référence Produit Dimensions standardisées (mm) Ampérage Référence FUSES ACCESSORIES 2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 246 Product Standardized dimensions (mm) Amperage Reference ISOL 1000N G4 6 x 32 0.315 A P01101724 ISOL 5000N G4 6 x 32 0.315 A P01101724 LOCAT 110 5 x 20 0.1 A P03297514 LOCAT 220 5 x 20 0.1 A P03297514 MANIP W1 6 x 32 1.25 A P01297015 MANIP Z10 5 x 20 0.16 A P03297508 MAN'X 015 6 x 32 1.6 A P01297017 MAN'X 02S 6 x 32 2 A P03297513 MAN'X 02S 10 x 38 10 A P01100731 MAN'X 04B 8 x 32 10 A P03100830 MAN'X 04B 5 x 20 1.6 A P03297501 MAN'X 102 5 x 20 0.160 A P03297508 MAN'X 102 6 x 32 3.15 A P01100726 MAN'X 500 6 x 32 2 A P03297513 MAN'X 500 6 x 32 16 A P03297505 MAN'X 520A 6 x 32 0.315 A P03297509 MAN'X 520A 6 x 32 16 A P03297505 MAN'X TOP 6 x 32 0.315 A P03297509 MAN'X TOP 6 x 32 16 A P03297505 MAN'X TOP PLUS 6 x 32 0.315 A P03297509 MAN'X TOP PLUS 6 x 32 16 A P03297505 MAX 2000 6 x 32 1 A P03297510 MAX 2000 6 x 32 10 A P03297510 MAX 3000 6 x 32 1 A P03297510 MAX 3000 6 x 32 10 A P03297510 MH600 5 x 20 0.16 A P01297043 MH600 5 x 20 0.310 A P01297045 MH600 5 x 20 0.315 A P01297074 RO600 5 x 20 2 A P01297069 RO600 5 x 20 0.25 A P01297070 Tellurohm C.A 2 6 x 32 0.1 A P01297012 C.A 5001 6 x 32 0.5 A P01297028 C.A 5001 6 x 32 5 A P01297035 C.A 6522 6 x 32 0.63 A P01297078 C.A 6524 6 x 32 0.63 A P01297078 C.A 6526 6 x 32 0.63 A P01297078 C.A 6532 6 x 32 0.63 A P01297078 C.A 6534 6 x 32 0.63 A P01297078 C.A 6536 6 x 32 0.63 A P01297078 C.A 6471 5 x 20 0.63 A AT0094
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 247
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 248 A B C Continuity test ________ 24, 62, 66, 78, 87, 91, 92 Current measurement clamp ________ 42, 118, 221 Current transformer D E Educational measuring instruments _________ 205 Electromagnetic disturbance analyser ________195 Energy management and analysis _______ 118, 128 F Fault detector (breaks, short-circuits) ________ 98 G H Hygrometry measurement _________ 174, 175, 184 I Insulation resistance measurement __ 62, 66, 78, 87 K L M Megohmmeter N O P Phase (detection, sequence testers) _______ 24, 97 Process current measurement clamp _________226 Protection (soft case, hard case, bag) _______ 234 Protection and transport accessories ________ 234 R S T THD (Total Harmonic Distortion) ______ 44, 45, 118 Transport (soft cases, hard cases, bags) _____ 234 U V W
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 249 A B C D E F G I J K L M P Q R S T U Y
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 250 P01102100Z ______41, 46 à 48, 191, 233, 234, 236
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 251
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 252 P01295451Z ______47, 48, 120, 121, 146, 191, 238 P01295456Z ______32, 37à 39, 41, 48, 77, 108, 238 P01295457Z ______ 47, 48, 77, 107 à 109,120, 121 P01298076 _30, 46, 48, 132, 133, 138, 146, 147, 233
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 253
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 254
2018 TEST & MEASUREMENT CATALOGUE WWW.CHAUVIN-ARNOUX.COM 255
906131116 - Ed. 3 - 04/2018 - Non-contractual document - Spécifications are to be confirmed at time of ordering CHAUVIN ARNOUX METRIX 190, rue Championnet
75876 PARIS Cedex 18
Tel.: +33 1 44 85 44 85 Fax: +33 1 46 27 07 48 info@chauvin-arnoux.fr www.chauvin-arnoux.fr PYROCONTROLE 6 bis, av du Docteur Schweitzer
69881 MEYZIEU Cedex
Tel.: +33 4 72 14 15 40 Fax: +33 4 72 14 15 41 info@pyrocontrole.com www.pyrocontrole.com CATALOGUE CAPTEURS LA MESURE DE TEMPÉRATURE EN MILIEU INDUSTRIEL CHAUVIN ARNOUX ENERGY 16, rue Georges Besse
92182 ANTONY Cedex
Tel.: +33 1 75 60 10 30 Fax: +33 1 46 66 62 54 info@enerdis.fr - www.enerdis.fr Catalogue général 2018 0000054,6 MANUMESURE 9, allée Jean Prouvé
92110 Clichy
Tél. : +33 1 75 61 01 80 Fax : +33 1 47 33 28 02 info@manumesure.fr www.manumesure.fr
10 SUBSIDIARIES WORLDWIDE
CHAUVIN ARNOUX GES.M.B.H Slamastrasse 29/2/4
1230 WIEN
Tel.: +43 1 61 61 9 61 Fax: +43 1 61 61 9 61-61 vie-office@chauvin-arnoux.at www.chauvin-arnoux.at CHINA SHANGHAI PU-JIANG ENERDIS INSTRUMENTS CO. LTD
3 Floor, Building 1
N° 381 Xiang De Road
200081 SHANGHAI
Tel.: +86 21 65 21 51 96 Fax: +86 21 65 21 61 07 info@chauvin-arnoux.com.cn GERMANY CHAUVIN ARNOUX GMBH Ohmstraße 1
77694 KEHL / RHEIN
Tel.: +49 7851 99 26-0 Fax: +49 7851 99 26-60 info@chauvin-arnoux.de www.chauvin-arnoux.de ITALY AMRA SPA Via Sant’Ambrogio, 23
20846 MACHERIO (MB)
Tel.: +39 039 245 75 45 Fax: +39 039 481 561 info@amra-chauvin-arnoux.it www.chauvin-arnoux.it MIDDLE EAST CHAUVIN ARNOUX MIDDLE EAST PO Box 60-154 1241 2020 JAL EL DIB (Beirut) - LEBANON Tel.: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com SPAIN CHAUVIN ARNOUX IBERICA SA C/ Roger de Flor N°293, 1a Planta
08025 BARCELONA
Tel.: +34 902 20 22 26 Fax: +34 934 59 14 43 info@chauvin-arnoux.es www.chauvin-arnoux.es SCANDINAVIA CA MÄTSYSTEM AB Sjöflygvägen 35 SE-183 62 TABY Tel.: +46 8 50 52 68 00 Fax: +46 8 50 52 68 10 info@camatsystem.com www.camatsystem.com SWITZERLAND CHAUVIN ARNOUX AG Moosacherstrasse 15
8804 AU / ZH
Tel.: +41 44 727 75 55 Fax: +41 44 727 75 56 info@chauvin-arnoux.ch www.chauvin-arnoux.ch UNITED KINGDOM CHAUVIN ARNOUX LTD Unit 1 Nelson Ct, Flagship Sq Shaw Cross Business Pk, Dewsbury West Yorkshire - WF12 7TH Tel: +44 1924 460 494 Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com USA CHAUVIN ARNOUX INC d.b.a AEMC Instruments
15 Faraday Drive
Tél. : +1 (800) 945-2362 Fax : +1 (603) 742-2346 sales@aemc.com www.aemc.com A CENTRALIZED CONTACT CHAUVIN ARNOUX 190, rue Championnet
75876 PARIS Cedex 18 FRANCE
Tel.: +33 1 44 85 44 85 Fax: +33 1 46 27 73 89 info@chauvin-arnoux.fr www.chauvin-arnoux.com INTERNATIONAL Tel: +33 1 44 85 44 38 Fax: +33 1 46 27 95 59 export@chauvin-arnoux.fr www.chauvin-arnoux.com UNITED KINGDOM CHAUVIN ARNOUX LTD Unit 1 Nelson Ct, Flagship Sq Shaw Cross Business Pk, Dewsbury West Yorkshire - WF12 7TH Tel: 01924 460 494 Fax: 01924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com MIDDLE EAST CHAUVIN ARNOUX MIDDLE EAST PO Box 60-154 1241 2020 JAL EL DIB (Beirut) LEBANON Tel.: (01) 89 04 25 Fax: (01) 89 04 24 camie@chauvin-arnoux.com www.chauvin-arnoux.com USA CHAUVIN ARNOUX INC d.b.a AEMC Instruments Tél. : +1 (800) 945-2362 Fax : +1 (603) 742-2346 sales@aemc.com www.aemc.com