KTEM8250G4CXSEV SENSORTECHNICS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
KTE8000/KTU8000...CS Series Submersible pressure transducers www.sensortechnics.com
FEATURES
- For corrosive media
- 4...20 mA output
- Field interchangeable SPECIFICATIONS 9,10 Maximum ratings Supply voltage2 (reverse polarity protection) 9...32 V Temperature limits Storage -40 to 70°C Operating -25 to 70°C Compensated 0 to 70°C Vibration (5 to 500 Hz) 10 g RMS Mechanical shock 50 g Proof pressure 3 2 x rated pressure ELECTRICAL CONNECTION MEDIA COMPATIBILITY Wetted materials: PPS, ceramic Al2O 3, NBR (Viton), PUR (PE)11 Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P 9 to 32 V red +Vs L GNDblack -Vs R V sensor
KTE8000/KTU8000...CS Series Submersible pressure transducers www.sensortechnics.com INDIVIDUAL PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 15 V, RL = 100 Ω, tamb = 25°C) Specification notes: 1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 5. Non-linearity refers to the B est S traight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Tests are in accordance with EN61000-6-2, April 1999. 9. CE-labelling is in accordance with 89/336/EEC. 10. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 11. Other sealing materials are available on request. scitsiretcarahC. niM. pyT. xaMt inU erusserpgnitarepO. ..0528METK ...0048METK ...0068METK ...0K18METK ...6K18METK ...0K28METK 052 004 006 0001 0061 0002 rabm ...5008UTK ...0108UTK ...5108UTK ...0208UTK ...0308UTK isp tesffoerusserporeZ9 .30 .41 .4 AmnapselacslluF 7 9.510 .611 .61 stceffelamrehT 4 )C°07ot0(t esffOH m5.2/isp5/rab52.0 2O4 0.0±8 0.0± C°/OSF% Hm01/isp51/rab1< 2O3 0.0±6 0.0± srehtolla2 0.0±4 0.0± napS2 0.0±4 0.0± )C°0ot52-(stceffelamrehTt esffOH m01/isp51/rab1< 2O6 0.0± srehtolla3 0.0± napS3 0.0± siseretsyh,ytiraenil-noN) LSB(y tilibataeperdna 5 1.0±3 .0± OSF%)zHk1<f<0(esiontuptuO 2.0± ytilibatsmretgnoL 6 2.0± )%09ot01(emitesnopseR 15 s m noitcejerylppusrewoPt esffO5 0.0± V/OSF%napS5 0.0±
KTE8000/KTU8000...CS Series Submersible pressure transducers www.sensortechnics.com LOAD LIMITATION ELECTROMAGNETIC CAPABILITY 8 snoitidnoctseTn oiretirCe cnerefretnI ycneuqerfoidar,detaidaR dleifcitengamortcele )IFR(ytinummi :3-4-00016NE3 edarG zHM0001otzHM08,m/V01 )zHk1(CMA%08 AO SF%1< /tneisnarttsaflacirtcelE )TFE(ytinummitsrub :4-4-00016NE3 edarG Vk2± BO SF%1< egrahcsidcitatsortcelE )DSE(tsetytinummi :2-4-00016NE4 edarG egrahcsidtcatnoc,Vk4± egrahcsidria,Vk8± BO SF%1< detcudnocotytinummI ybdecudnisecnabrutsid sdleifycneuqerf-oidar :6-4-00016NE3 edarG zHM08ot51,0 )zHk1(CMA%08,V01 AO SF%1< ytinummiegruS: 5-4-00016NE1 edarG cirtemmysa/cirtemmys,Vk5.0± 2edarG cirtemmysa,Vk1± BO SF%1< 600 0 95 200 400 800 1000 Ohm 1200 1400 3020 25 supply voltage 32 V operating range
KTE8000/KTU8000...CS Series Submersible pressure transducers www.sensortechnics.com OUTLINE DRAWING NOITCENNOCERIW roloCn oitcennoclacirtcelE ders V+ kcalbs V- tnerapsnarte buttnev 1 dimensions in mm (inches)
ORDERING INFORMATION
Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. KTx M 8xxx G 4 C x S x x sealing material V: Viton N: NBR cable material E: PE U: PUR submersible cable length in m cable version output signal 4: 4...20 mA calibration E: calibration in mbar U: calibration in psi mbar-ranges (only) pressure range 250: 0 to 250 mbar 400: 0 to 400 mbar 600: 0 to 600 mbar 1K0: 0 to 1000 mbar 1K6: 0 to 1600 mbar 2K0: 0 to 2000 mbar pressure mode G: gage pressure 005: 0 to 5 psi 010: 0 to 10 psi 015: 0 to 15 psi 020: 0 to 20 psi 030: 0 to 30 psi Note: Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative. Ø8.0 (0.31) 4 x 90° 6.0 (0.24) NOM 122.5 (4.82) NOM 100 (3.94) NOM 70 (2.76) NOM 2000 (78.74) other cable lengths on request Ø 24.0 (0.94) Hydrophobic filter (incl. in delivery)