KTDELQS1.12 OSRAM | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 22
Technical content
Version 1.1 KT DELQS1.12 The TOPLED E1608 expands OSRAM Opto Semiconductors’ low power portfolio by offering one of the smallest LED Industry standard footprints in a highly reliable and well prooved package concept. I ts outstanding performance is suitable for a huge vari ety of applications especially automotive interior wher e a small package design with excellent reliability is needed. The TOPLED E1608 is available in different colors and brightness levels. Die TOPLED E1608 erweitert die Low power Produktpalette von OSRAM Opto Semiconductors mit einem der kleinsten LED-Package Abmaße in einem hoch zuverlässigen und stabilem Package-Konzept. Die außergewöhnliche Performance eignet sich für eine Vielzahl von Anwendungen besonders im Automobil-Innenbereich, bei denen ein kleines Package Design mit hervorragender Zuverlässigkeit benötigt wird. Die TOPLED E1608 gibt es in einer Vielzahl an Farben und Helligkeitsniveaus. Features: Besondere Merkmale:
- Package: white SMT package, colorless clear resin
- Gehäusetyp: weißes SMT Gehäuse, farbloser klarer Verguss
- Technology: ThinGaN • Technologie: ThinGaN
- Viewing angle at 50 % I V: 120° • Abstrahlwinkel bei 50 % I V: 120°
- Color: true green • Farbe: true green Applications Anwendungen
- Automotive Interior Lighting • Automobilbeleuchtung innen
- Dashboard Backlighting • Instrumentenbeleuchtung
- Pushbuttons and Switches • Schalter und Taster
- Electronic Equipment • elektronische Geräte
- Signal and Symbol Luminary • Signal- und Symbolleuchten
Version 1.1 KT DELQS1.12
Ordering Information
Type: Luminous Intensity 1) page 21 Ordering Code Typ: Lichtstärke 1) Seite 21 Bestellnummer IF = 10 mA IV [mcd] KT DELQS1.12-THVH-36-W6A6 330 ... 970 Q65112A4000 Note: The above Type Numbers represent the order gr oups which include only a few brightness groups (se e page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. KT DELQS1.12-THVH-36-W6A6 means that only one group TH, TI, UG, UH, UI, VG, V H will be shippable for any packing unit. In a similar manner for colors where wavelength gro ups are measured and binned, single wavelength grou ps will be shipped on any DELQS1.12-THVH-36-W6A6 means that the device will b e shipped within the specified limits as stated on page 5. In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus we nigen Helligkeitsgruppen bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen TH, TI, UG, UH, UI, VG, VH enhalten ist. Gleiches gilt für die Farben, bei denen Wellenlängengruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Wellenlängengruppe geliefert. Z. B. KT DELQS1.12-TH VH-36-W6A6 bedeutet, dass in einer Verpackungseinhe it nur eine der Wellenlängengruppen 3,4,5,6 enthalten ist (siehe Seite 5). KT DELQS1.12-THVH-36-W6A6 bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Gleiches gilt für die LEDs, bei denen die Durchlass spannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z . B. KT DELQS1.12-THVH-36-W6A6 bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannu ngsgruppen 46,A6,W6 enthalten (siehe Seite 5).
Version 1.1 KT DELQS1.12 2017-06-06 3 Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 110 °C Storage temperature range Lagertemperatur Tstg -40 ... 110 °C Junction temperature Sperrschichttemperatur Tj 125 °C Forward current Durchlassstrom (TS = 25 °C) IF 2 ... 30 mA Surge current Stoßstrom IFM 70 mA ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class 2) VESD 2 kV
Version 1.1 KT DELQS1.12 Characteristics (TS = 25 °C; I F = 10 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Dominant Wavelength 2) page 21 Dominantwellenlänge 2) Seite 21 (min.) (max.) λdom λdom 519 543 nm nm Viewing angle at 50 % I V Abstrahlwinkel bei 50 % I V (typ.) 2ϕ 120 ° Forward voltage 3) page 21 Durchlassspannung 3) Seite 21 (min.) (typ.) (max.) VF VF VF 2.60 3.10 3.50 V V V Real thermal resistance junction / solder point 4) page 21 Realer Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 (typ.) (max.) Rth JS real Rth JS real 100 120 K/W K/W Note: Individual forward voltage groups see next pa ge Anm.: Durchlassspannungsgruppen siehe nächste Seite
Version 1.1 KT DELQS1.12 2017-06-06 5 Brightness Groups Helligkeitsgruppen Forward Voltage Groups 3) page 21 Durchlassspannungsgruppen 3) Seite 21 Dominant Wavelength Groups 2) page 21 Dominant Wellenlängengruppen 2) Seite 21 Group Luminous Intensity 1) page 21 Luminous Intensity 1) page 21 Luminous Flux 5) page 21 Gruppe Lichtstärke 1) Seite 21 Lichtstärke 1) Seite 21 Lichtstrom 5) Seite 21 (min.) Iv [mcd] (max.) Iv [mcd] (typ.) ΦV [mlm] TH 330 390 1130 TI 390 450 1320 UG 450 520 1530 UH 520 610 1780 UI 610 710 2080 VG 710 820 2410 VH 820 970 2820 Group Gruppe (min.) VF [V] (max.) VF [V] W6 2.60 2.90 46 2.90 3.20 A6 3.20 3.50 Group true green Gruppe (min.) λdom [nm] (max.) λdom [nm] 3 519 525 4 525 531 5 531 537 6 537 543 Note: No packing unit / tape ever contains more tha n one color group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Farbe enthalten.
Version 1.1 KT DELQS1.12 Group Name on Label Gruppenbezeichnung auf Etikett Example: TH-3-46 Beispiel: TH-3-46 Brightness Helligkeit Wavelength Wellenlänge Forward Voltage Durchlassspannung TH 3 46 Note: No packing unit / tape ever contains more tha n one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten.
Version 1.1 KT DELQS1.12 2017-06-06 7 Relative Spectral Emission - V(λ) = Standard eye re sponse curve 5) page 21 Relative spektrale Emission - V(λ) = spektrale Auge nempfindlichkeit 5) Seite 21 Irel = f (λ); T S = 25 °C; I F = 10 mA Radiation Characteristics 5) page 21 Abstrahlcharakteristik 5) Seite 21 Irel = f (ϕ); T S = 25 °C KT DELQS1.12 350 400 450 500 550 600 650 700 750 800 λ [nm] 0,0 0,2 0,4 0,6 0,8 1,0 I rel : Vλ : true green KT DELQS1.12 -100° -90° -80° -70° -60° -50° -40° -30° -20° ϕ [°] 0,0 0,2 0,4 0,6 0,8 1,0 Irel : 0° : 90°
Version 1.1 KT DELQS1.12 Forward Current 5) page 21 , 6) page 21 Durchlassstrom 5) Seite 21 , 6) Seite 21 IF = f (V F); T S = 25 °C Relative Luminous Intensity 5) page 21 , 6) page 21 Relative Lichtstärke 5) Seite 21 , 6) Seite 21 IV/I V(10 mA) = f(I F); T S = 25 °C Dominant Wavelength 5) page 21 Dominante Wellenlänge 5) Seite 21 λdom = f(I F); T S = 25 °C KT DELQS1.12 VF [V] IF [mA] KT DELQS1.12 2 70 2 3 4 5 10 20 30 40 50 IF [mA] 0,3 0,4 0,5 IV I V(10 mA ) KT DELQS1.12 2 10 20 30 40 50 60 70 IF [mA] 460 480 500 520 540 560 580 λ dom [nm]
Version 1.1 KT DELQS1.12 2017-06-06 9 Relative Forward Voltage 5) page 21 Relative Vorwärtsspannung 5) Seite 21 ΔV F = V F - V F(25 °C) = f(T j); I F = 10 mA Relative Luminous Intensity 5) page 21 Relative Lichtstärke 5) Seite 21 IV/I V(25)°C = f(T j); I F = 10 mA Dominant Wavelength 5) page 21 Dominante Wellenlänge 5) Seite 21 λdom = f(T j); I F = 10 mA KT DELQS1.12 -40 -20 0 20 40 60 80 100 120 Tj [°C] -0,4 -0,2 0,0 0,2 0,4 ΔVF [V] KT DELQS1.12 -40 -20 0 20 40 60 80 100 120 Tj [°C] 0,0 0,2 0,4 0,6 0,8 1,0 1,2 Iv I v(25 °C ) KT DELQS1.12 -40 -20 0 20 40 60 80 100 120 Tj [°C] Δλ dom [nm]
Version 1.1 KT DELQS1.12 Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T) Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit I F = f(t p) D: Duty cycle KT DELQS1.12 0 20 40 60 80 100 T [°C] IF [mA] : Ts 10 -6 10 -5 10 -4 10 -3 0,01 0,1 1 10 Pulse time [s] IF [mA] TS = 0°C ... 110°C KT DELQS1.12 : D = 1.0 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005
Version 1.1 KT DELQS1.12 2017-06-06 11 Package Outline 7) page 21 Maßzeichnung 7) Seite 21 Approximate Weight: 2 mg Gewicht: 2 mg Mark: Anode Markierung: Anode
Version 1.1 KT DELQS1.12 Electrical Internal Circuit Internes Elektrisches Schaltbild
Version 1.1 KT DELQS1.12 2017-06-06 13 Recommended Solder Pad 7) page 21 Reflow soldering Empfohlenes Lötpaddesign 7) Seite 21 Reflow-Löten Note: For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Anm.: Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter Standard- Stickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet.
Version 1.1 KT DELQS1.12 Reflow Soldering Profile Reflow-Lötprofil Product complies to MSL Level 3 acc. to JEDEC J-STD -020E 00 s OHA04525 100 150 200 250 300 50 100 150 200 250 300 t T St t Pt Tp240 ˚C 217 ˚C 245 ˚C 25 ˚C L OHA04612 Profile Feature Profil-Charakteristik Ramp-up rate to preheat*) 25 °C to 150 °C 2 3 K/s Time tS TSmin to TSmax tS tL tP TL TP 100 12060 10 20 30 80 100 217 2 3 245 260 3 6 Time 25 °C to T P Time within 5 °C of the specified peak temperature TP - 5 K Ramp-down rate* TP to 100 °C All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/ Dt: Dt max. 5 s; fulfillment for the whole T-range Ramp-up rate to peak*) TSmax to T P Liquidus temperature Peak temperature Time above liquidus temperature Symbol Symbol Unit Einheit Pb-Free (SnAgCu) Assembly Minimum MaximumRecommendation K/s K/s s s s s 480
Version 1.1 KT DELQS1.12 2017-06-06 15 Taping 7) page 21 Gurtung 7) Seite 21
Version 1.1 KT DELQS1.12 Tape dimensions [mm] Gurtmaße [mm] Tape dimensions in mm Reel dimensions [mm] Rollenmaße [mm] Reel dimensions in mm Tape and Reel Gurtverpackung 8 mm tape with 5000 pcs. on ∅ 180 mm reel W P0 P1 P2 D0 E F or 4 ± 0.1 A W Nmin W1 W2max 180 8 60 8.4 + 2 14.4 W F E Direction of unreeling N A OHAY0324 Label Leader: Trailer: 13.0 Direction of unreeling ±0.25 min. 160 mm * min. 400 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D
Version 1.1 KT DELQS1.12 2017-06-06 17 Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) Dry Packing Process and Materials Trockenverpackung und Materialien Note: Moisture-sensitive product is packed in a dry bag c ontaining desiccant and a humidity card. Regarding dry pack you will find further informatio n in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative refere nces like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinw eise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Norm enbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. OHA00539 OSRAM Moisture-sensitive label or print Barcode label Desiccant Humidity indicator Barcode label OSRAM Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. WET Do not eat. Comparatorcheck dot parts still adequately dry. examine units, if necessary examine units, if necessary 15% 10%bake units bake units If wet, change desiccant If wet, Humidity Indicator MIL-I-8835 If wet, Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label
Version 1.1 KT DELQS1.12 Transportation Packing and Materials Kartonverpackung und Materialien Dimensions of transportation box in mm Width Length Height Breite Länge Höhe 200 ± 5 195 ± 5 30 ± 5 OHA02044 PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP:
260 C RT240 C R
220 C RML
Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY PACKVAR:R077Additional TEXT P-1+Q-1Multi TOPLED Muster OSRAM OptoSemiconductors (6P) BATCH NO: (X) PROD NO: (9D) D/C: 1 1(1T) LOT NO: 210021998 123GH1234 0 2 4 5 (Q)QTY: 2000 0144 (G) GROUP: Bin3:Bin2: Q-1-20Bin1: P-1-20 LSY T676 2 2a Temp ST R18 DEMY OSRAM Packing Sealing label Barcode label Moisture Level 3 Floor time 168 Hours Moisture Level 6 Floor time 6 Hours a) Humidity Indicator Card is > 10% when read at 23 ˚C ± 5 ˚C, or reflow, vapor-phase reflow, or equivalent processing (peak package2. After this bag is opened, devices that will be subjected to infrared 1. Shelf life in sealed bag: 24 months at < 40 ˚C and < 90% relative humidity (RH). Moisture Level 5a at factory conditions of (if blank, seal date is identical with date code). a) Mounted within b) Stored at body temp. 3. Devices require baking, before mounting, if: Bag seal date Moisture Level 1 Moisture Level 2 Moisture Level 2a 4. If baking is required, b) 2a or 2b is not met. Date and time opened: reference IPC/JEDEC J-STD-033 for bake procedure. Floor time see below If blank, see bar code label Floor time > 1 Year Floor time 1 Year Floor time 4 Weeks 10% RH._< Moisture Level 4 Moisture Level 5 ˚C). OPTO SEMICONDUCTORS MOISTURE SENSITIVE This bag containsCAUTION Floor time 72 Hours Floor time 48 Hours Floor time 24 Hours 30 ˚C/60% RH._< LEVEL If blank, seebar code label Barcode label
Version 1.1 KT DELQS1.12 2017-06-06 19 Notes Hinweise The evaluation of eye safety occurs according to th e standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights ), temporary reduction in visual acuity and afterimage s can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. Subcomponents of this LED are silverplated. Silver is discoloring when being exposed to environments containing high concentrations of aggressive substances. Corroded silver may lead to a worsening of the optical performance of the LED and can in th e worst case lead to a failure of the LED. Do not expose this LED to aggressive atmospheres. Note, that corrosive gases may as well be emitted from materials close to the LED in the final product. Einzelkomponenten dieser LED sind silberbeschichtet. Silberoberflächen werden durch korrosive Substanzen verändert. Korrodiertes Silber kann zu einer Verschlechterung der optischen Eigenschaften und im schlimmsten Fall zum Ausfall der LED führen. Diese LED darf aggressiven Bedingungen nicht ausgesetzt werden. Es ist zu beachten, dass korrosive Gase auch von Materialien emittiert werden können, die sich im Endprodukt in unmittelbarer Umgebung der LED befinden. For further application related informations please visit www.osram-os.com/appnotes Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes
Version 1.1 KT DELQS1.12 Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two languag e wordings. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please con tact our Sales Organization. If printed or downloaded, please find the latest ve rsion in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invo ice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-suppo rt devices** or systems with the express written appro val of OSRAM OS. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its saf ety or the effectiveness of that device or system. **) Life support devices or systems are intended (a ) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fai l, it is reasonable to assume that the health and the life o f the user may be endangered. Bei abweichenden Angaben im zweisprachigen Wortlaut haben die Angaben in englischer Sprache Vorrang. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für wei tere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollte n, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Materia l sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich z u einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper od er (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr is t.
Version 1.1 KT DELQS1.12 2017-06-06 21 Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an interna l reproducibility of ± 8 % and an expanded uncertaint y of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Wavelength: The wavelength is measured at a current pulse of typically 25 ms, with an internal reproducibility of ± 0.5 nm and an expanded uncertainty of ± 1 nm (acc. to GUM with a coverage factor of k = 3). 2) Wellenlänge: Die Wellenläge wird während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,5 nm und einer erweiterten Messunsicherheit von ± 1 nm gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 3) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expande d uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 3) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Thermal Resistance: Rth max is based on statistic values (6σ). 4) Wärmewiderstand: Rth max basiert auf statistischen Werten (6σ). 5) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typ ical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 5) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 6) Characteristic curve: In the range where the line of the graph is broken, you must expect higher differences between single LEDs within one packing unit. 6) Kennlinien: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Abweichungen zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 7) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 7) Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben.
Version 1.1 KT DELQS1.12 Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.