Date:2014/10/20 http://www.nhel.com.cn Page: 1 of 3Rev.:AA Production Data Sheet Niu Hang Electronic Co. Ltd K090 THRU K260 70 to 220 Volts HIGH VOLTAGE BIDIRECTIONAL TRIGGER DIODE The plastic package carries Underwriters Laboratory Flammability Classification 94V-0 Bidirectional crowbar protection Fast response High forward surge current capability High temperature soldering guaranteed
250 C/10 seconds on terminals
High surge current capability Thermal Considerations Symbol Parameter Value Unit T J Operating Junction Temperature Range -40 to +125 °C T S Storage Temperature Range -65 to +150 °C R /g113JA Thermal Resistance: Junction to Ambient 90 °C/W Average On-state Current (AV) 1.0 A Maximum Surge Current (50H ) 4.0 A T TSM I T Case : JEDEC DO-214AA molded plastic body Terminals: Plated leads, solderable per MIL-STD-750, Method 2026 Mounting Position : Any Weight: 0.0048 ounce, 0.136grams MECHANICAL DATA Electrical Parameters Part Number V DRM Volts V Volts I DRM µAmps I H mAmps I mAmps V TM K090 70 1 80 100 0.5 10 50 2.0 K110 95 1 100 120 0.5 10 50 2.0 K120 100 1 110 130 0.5 10 50 2.0 K130 110 1 120 140 0.5 10 50 2.0 K140 120 1 130 150 0.5 10 50 2.0 K160 140 1 150 170 0.5 10 50 2.0 K180 160 1 170 190 0.5 10 50 2.0 K200 180 1 190 210 0.5 10 50 2.0 K220 190 1 210 230 0.5 10 50 2.0 K240 200 1 230 250 0.5 10 50 2.0 K260 220 1 250 270 0.5 10 50 2.0 Min Max BO Min Max BO Volts Max Min Max Max K105 90 1 95 115 0.5 10 50 2.0 K150 130 1 140 160 0.5 10 50 2.0
Electronic Co. Ltd Page: 2 of 3Date:2014/10/20 Rev.:AA K090 THRU K260 70 to 220 Volts HIGH VOLTAGE BIDIRECTIONAL TRIGGER DIODE RATINGS AND CHARACTERISTIC CURVES K090 THRU K260 V-I Characteristics V DRM V S I S I H R S I DRM I BO V BO V T I T S - I BO BO - V S S = Peak Surge Current versus Surge Current Duration Normalized DC Holding Current versus Case/Lead Temperature 1.0 10 100 1000 1.0 2.0 4.0 6.0 8.0 SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS ON-STATE CURRENT: I T RMS Maximum Rated Value at Specified Junction Temperature Notes: 1) Blocking capability may be lost during and immediately following surge current interval. 2) Overload may not be repeated until junction temperature has returned to steady-state rated value. Surge Current Duration – Full Cycles Peak Surge (Non-repetitive) On-state Current [I TSM ] – Amps 100 0.5 1.0 2.0 1.5 -15-40 +25 +65 +105 +125 Case Temperature (T C ) – C IH I H C = 25 Ratio of 100 t r t d Peak Value Half Value t – Time (µs) I PP – Peak Pulse Current – %I PP t r = rise time to peak value t d = decay time to half value Waveform = t r x t d t r x t d Pulse Wave-form Repetitive Peak On-state Current (I TRM ) versus Pulse Width at Various Frequencies Normalized Repetitive Peak Breakover Current versus Junction Temperature di/dt Limit Line 0.6 0.8 100 200 400 600 2 x 10-3 1 x 10-2 24 6 8 1 x 10-1 24 6 8 1 Pulse base width (t o ) – ms Repetitive Peak On-state Current (I TRM ) – Amps V BO Firing Current Waveform Non-Repeated Repetition Frequency f=5 Hz f = 10 Hz f = 100 Hz f = 1 kHz f = 5 kHz f = 10 kHz f = 20 kHz T J = 125 ºC Max to ITRM l/f Non-Repeated 20 30 40 50 60 70 80 90 100 110 120 130 Junction Temperature (T J ) – C Repetitive Peak Breakover Current (I BO ) Multiplier V = V BO http://www.nhel.com.cn
Page: 3 of 3Date:2014/10/20 Rev.:AA Production Data Sheet Niu Hang Electronic Co. Ltd K090 THRU K260 70 to 220 Volts HIGH VOLTAGE BIDIRECTIONAL TRIGGER DIODE Maximum Allowable Ambient Temperature versus On-state Current Normalized V BO Change versus Junction Temperature On-state Current versus On-state Voltage (Typical) Power Dissipation (Typical) versus On-state Current [Refer to Figure E9.14 for Basic Sidac Circuit] 100 120 140 RMS On-state Current [I T(RMS) ] – Amps Maximum Allowable Ambient Temperature (T A ) – ˚C CURRENT WAVEFORM: Sinusoidal - 60 Hz LOAD: Resistive or Inductive FREE AIR RATING -12 -20 0 +20 +40 +60 +80 +100 +120 -10 -40 +25 Junction Temperature (T J ) – ˚C Percentage of V BO Change – % +140 Positive or Negative Instantaneous On-state Voltage (v T ) – Volts Positive or Negative Instantaneous On-state Current (i T ) – Amps TL = 25 ˚C 0.4 0.8 1.2 1.6 0.2 0.6 1.0 1.4 1.8 2.0 2.2 RMS On-state Current [I T(RMS) ] – Amps Average On-state Power Dissipation [P D(AV) ] – Watts CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: See Basic Sidac Cirucit RATINGS AND CHARACTERISTIC CURVES K090 THRU K260 http://www.nhel.com.cn