IPT1-FP PF | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

< With integrated control interface unit < Serial interfaces and field-bus interfaces selectable through lower part < Read distance of up to 100 mm < Write distance of up to 50 mm < 3 LEDs for function indication < Degree of protection IP67 < Optimized reading speed for fixed codes < Suited for writing of IPC11 LF R/W system, fully assembled as configuration and test station Function The IPT1-FP read/write station is used in combination with a base which contains the interface for connecting to a computer. Through the choice of base, either serial interfaces or field-bus interfaces may be selected. The analysis system is integrated in the device and simplifies the system construction. Protection class IP67 allows the device to be installed directly in the field. Dimensions 2 3 2 9 8 0 6 5 8 0 6 5 6 0 1 5 Technical Data General specifications Operating frequency 125 kHz Transfer rate 2 kBit/s Operating distance maximum: 100 mm UL File Number E87056 Release date: 2021-06--

18 Date of

Release date: 2021-06-18 Date of issue: 2021-06-18 Filename: 183956_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091

Indicators/operating means LED green Power on LED yellow IPC detected LED red bus fault (when using fieldbus interfaces) Electrical specifications Rated operating voltage Ue 20 ... 30 V DC , ripple 10 %SS , PELV Power consumption P0 max. 5 W , in connection with the base Galvanic isolation Operating voltage/interface functional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff Mag. Field strength < 27.3 dBµA/m at 10 m Interface Physical Interface type depends on base used Approvals and certificates EAC conformity TR CU 020/2011 Ambient conditions Mechanical specifications Degree of protection IP67 according to EN 60529, with base Material Housing PBT Matching System Components U-P3-RX Base with serial interfaces RS 232 and RS 485 U-P3-R4 Base with addressable serial Interface RS 485 U-P3-R4-V15 Base with addressable serial Interface RS 485 U-P6-B5 Base for INTERBUS U-P6-B5-V Base for INTERBUS, plug-in connection U-P6-B6 Base for PROFIBUS DP U-P6-B6-V15B Base for PROFIBUS DP, plug-in connection U-P6V4A-B6 Base for PROFIBUS DP, stainless steel version U-P3V4A-RX Base with serial interfaces RS 232 and RS 485, stainless steel version V4A Read/write station IPT1-FP Release date: 2021-06-18 Date of issue: 2021-06-18 Filename: 183956_eng.pdf Germany: +49 621 776 1111 Pepperl+Fuchs Group Refer to "General Notes Relating to Pepperl+Fuchs Product Information". USA: +1 330 486 0001 Singapore: +65 6779 9091