ILPA35JU-SERIES Vitec | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
ILPA35JU SERIES 35W Water-Proof Constant Current LED Driver – Wide Input Voltage 90 to 305VAC, 47 to 63Hz – Constant Current Output – High Efficiency (up to 88%) – Active Power Factor Correction (PFC) – Over Voltage, Short Circuit, Lighting, and Over Temperature Protection – IP67 Waterproof Rating, Metal Housing – Comply with UL8750 & EN61347 Safety Regulation
3 Year Warranty Approvals:
Part Number Output Current Range (Min. / Typ. / Max.) Output Voltage Range (Min. / Max.) Efficiency (220VAC, Full Load) Over Voltage Protection (Min/Typ/Max) Max. Output Power ILPA35JU-S290ST 2755 / 2900 / 3045 mA 4 / 12 VDC 82% 13 / 15 / 17 VDC 35W ILPA35JU-S245ST 2328 / 2450 / 2573 mA 5 / 15 VDC 83% 16 / 18 / 20 VDC 35W ILPA35JU-S210ST 1995 / 2100 / 2205 mA 6 / 18 VDC 84% 19 / 21 / 23 VDC 35W ILPA35JU-S175ST 1663 / 1750 / 1838 mA 7 / 20 VDC 84% 23 / 25 / 27 VDC 35W ILPA35JU-S140ST 1330 / 1400 / 1470 mA 8 / 24 VDC 85% 30 / 32 / 34 VDC 35W ILPA35JU-S105ST 998 / 1050 / 1103 mA 11 / 33 VDC 86% 39 / 41 / 43 VDC 35W ILPA35JU-S070ST 665 / 700 / 735 mA 17 / 50 VDC 86% 57 / 58 / 59 VDC 35W ILPA35JU-S045ST 428 / 450 / 473 mA 26 / 78 VDC 87% 95 / 97 / 99 VDC 35W ILPA35JU-S035ST 333 / 350 / 368 mA 33 / 100 VDC 88% 118 / 120 / 122 VDC 35W Item -S290ST, -S245ST, -S210ST, -S175ST, -S140ST, -S105ST are Class 2 output (USR & CNR). Item -S070ST is Class 2 output (USR), Non-Class 2 output (CNR) Item -S045ST, -S035ST is Non-Class 2 output (USR & CNR)
Electrical Characteristics
Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Operating Voltage 90 305 VAC Input Frequency 47 63 Hz Output Power Range Vin=90 to 264VAC 0 35 W Input Current (Low Line) Io=Full load, Vin=115VAC 0.49 A Input Current (High Line) Io=Full load, Vin=230VAC 0.25 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 20 A Power Factor Correction Vin=110VAC 92 % Efficiency Io=Full Load, Vin=230VAC 82 88 % No-Load Power Consumption No Load, VIn=230VAC 6 W Line Regulation Io=Full Load 2 % Load Regulation Vin=230VAC 5 % Over Voltage Protection (Latch mode. The power unit shall return to normal operation only after the power is turn-on again.) Over Temperature Protection 110 °C Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. Output Overshoot / Undershoot When power on or off 10 % Start Up Time Io=Full Load, Vin=110VAC 1.7 2 S Ripple & Noise (Peak to Peak) Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. 10 % Vo
Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature Humidity: 10% RH to 100% RH -35 55 °C Storage Temperature Humidity: 5% RH to 100% RH -40 85 °C MTBF (Operation temperature at 25° C, calculated per MIL -HDBK-217F ) 0.541M Hours Life Time (measured at 110VAC, 45° C ambient temperature, 80% load for 2900mA output model) 0.087M Hours No output power derating from -35° C to 55° C Approvals and Compliance Parameter Standards EMI EN55015 EMS EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3 , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 CSA-C22.2 No.250.0, EN61347-1,EN61347-2-13 Waterproof IP67 Rating Mechanical & Technical Parameter Specification Net Weight 480g approx. Notes: 1. For the driver to operate properly, the load voltage must be maintained above the minimum voltage threshold (approx. 33% of the max. output voltage for any given model). 2. If the input voltage is within 90-175Vac, the output current can be varied from 100% down to 10%. (Refer to right figure A) 3. If the input voltage is within 175-305Vac, the output current can be varied from 100% down to 20%. (Refer to right figure B)