ILPA30JW SERIES 30W Water-Proof Constant Current LED Driver – Wide Input Voltage 90 to 264VAC, 47 to 63Hz – Constant Output Current Available From 0.35A To 2.5A – Over Voltage, Short Circuit, Lighting, and Over Temperature Protection – High Efficiency (up to 86%) – Active Power Factor Correction (PFC) (86% typical) – IP67 Waterproof Rating, Metal Housing – Comply with UL8750 & EN61347 Safety Regulation

2 Year Warranty Approvals:

Part Number Output Current Range (Min. / Typ. / Max.) Output Voltage Range (Min. / Max.) Efficiency (220VAC, Full Load) Over Voltage Protection (Min/Typ/Max) Max. Output Power ILPA30JW-S250SS 2375 / 2500 / 2625 mA 7 / 12 VDC 83% 14 / 16 / 18 VDC 30W ILPA30JW-S166SS 1580 / 1660 / 1740 mA 9 / 18 VDC 84% 22 / 24 / 27 VDC 30W ILPA30JW-S125SS 1190 / 1250 / 1310 mA 13 / 24 VDC 85% 29 / 32 / 36 VDC 30W ILPA30JW-S083SS 790 / 830 / 870 mA 18 / 36 VDC 86% 43 / 48 / 54 VDC 30W ILPA30JW-S070SS 665 / 700 / 735 mA 21 / 42 VDC 86% 50 / 57 / 63 VDC 30W ILPA30JW-S045SS 428 / 450 / 472 mA 33 / 66 VDC 86% 79 / 89 / 99 VDC 30W ILPA30JW-S035SS 333 / 350 / 367 mA 43 / 86 VDC 87% 103 / 116 / 129 VDC 30W Item -S250SS, -S166SS, -S125SS use Class 2 output (USR & CNR). Item -S083SS, -S070SS -S045SS, -S035SS use Non-Class 2 output (USR & CNR).

Electrical Characteristics

Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Operating Voltage 90 264 VAC Input Frequency 47 63 Hz Output Power Range Vin=90 to 264VAC 0 30 W Input Current (Low Line) Io=Full load, Vin=115VAC 0.43 A Input Current (High Line) Io=Full load, Vin=230VAC 0.25 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 65 A Power Factor Correction Vin=110VAC 86 % Efficiency Io=Full Load, Vin=230VAC 82.5 87 % No-Load Power Consumption No Load, VIn=230VAC 1 W Line Regulation Io=Full Load 1 % Load Regulation Vin=230VAC 3 % Over Voltage Protection Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) Over Temperature Protection 110 °C Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. Output Overshoot / Undershoot When power on or off 10 % Start Up Time Io=Full Load, Vin=100VAC 3 S Ripple & Noise (Peak to Peak) Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. 2 % Vo

Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature Humidity: 10% RH to 100% RH -35 60 °C Storage Temperature Humidity: 5% RH to 100% RH -40 85 °C Operation temperature at 25° C, calculated per MIL-HDBK-217F 0.3M Hours Life Time at 25° C ambient temperature 0.08M Hours No output power derating from -35° C to 60° C Approvals and Compliance Parameter Standards EMI EN55015 EMS EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 No.250.0, EN61347-1,EN61347-2-13 Waterproof IP67 Rating Mechanical Parameter Specification Net Weight 460g