ILPA150VU-SERIES Vitec | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
ILPA150VU SERIES 150W Water-Proof Constant Voltage LED Driver – Wide Input Voltage 90 to 305VAC, 47 to 63Hz – Constant Output Voltage Available From 12VDC To 105VDC – Over Voltage, Over Current, Short Circuit, and Over Temperature Protection – High Efficiency (up to 94%) – Active Power Factor Correction (PFC) (99% typical) – IP67 Waterproof Rating, Metal Housing – Comply with UL8750 & EN61347 Safety Regulation (Pending)
3 Year Warranty Approvals:
Part Number Output Voltage Max. Output Current Efficiency (220VAC, Full Load) Over Voltage Protection Min / Typ / Max Max. Output Power ILPA150VU-S012ST 12 VDC 12.5 A 92% 14V / 15V / 16V 150W ILPA150VU-S024ST 24 VDC 6.25 A 93% 27V / 30V / 34V 150W ILPA150VU-S036ST 36 VDC 4.17 A 93% 40V / 43V / 48V 150W ILPA150VU-S042ST 42 VDC 3.75 A 94% 45V / 50V / 53V 150W ILPA150VU-S048ST 48 VDC 3.57 A 93% 47V / 51V / 55V 150W ILPA150VU-S050ST 50 VDC 3.13 A 93% 54V / 58V / 61V 150W ILPA150VU-S052ST 52VDC 3.00A 93% 56V / 60V / 63V 150W ILPA150VU-S054ST 54 VDC 2.88 A 93% 58V / 62V / 66V 150W ILPA150VU-S056ST 56 VDC 2.78 A 93% 60V / 65V / 69V 150W ILPA150VU-S081ST 81 VDC 1.85 A 94% 91V / 95V / 100V 150W ILPA150VU-S105ST 105 VDC 1.42 A 94% 118V / 128V / 135V 150W
Electrical Characteristics
Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Operating Voltage 90 305 VAC Input Frequency 47 63 Hz Output Power Range Vin=90 to 264VAC 0 150 W Input Current (Low Line) Io=Full load, Vin=115VAC 1.75 A Input Current (High Line) Io=Full load, Vin=230VAC 0.8 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 50 A Power Factor Correction Vin=110VAC 99 % Power Factor Correction Vin=220VAC 96 % Efficiency Io=Full Load, Vin=230VAC 93 94 % No-Load Power Consumption No Load, VIn=230VAC 1.5 W Line Regulation Io=Full Load 1 % Load Regulation Vin=230VAC 2 % Over Voltage Protection Latch mode. The power unit shall return to normal operation only after the power is turn-on again. Over Current Protection 110 135 180 % Io Over Temperature Protection 110 °C Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. Self-recovery. Output Overshoot / Undershoot When power on or off 10 % Start Up Time Io=Full Load, Vin=100VAC 3 S Ripple & Noise (Peak to Peak) Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. 2 % Vo
Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature Humidity: 10% RH to 100% RH -35 70 °C Storage Temperature Humidity: 5% RH to 100% RH -40 85 °C Operation temperature at 25° C, calculated per MIL-HDBK-217F 0.45M Hours Life Time at 25° C ambient temperature 0.1M Hours No output power derating from -35° C to 65° C Approvals and Compliance Parameter Standards EMI EN55015 EMS EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 No.250.0, EN61347-1,EN61347-2-13 Waterproof IP67 Rating Mechanical Parameter Specification Dimension 199x67.5x40 mm (7.83x2.66x1.57 inches) Net Weight 1000g approx.