ILPA100VU-SERIES Vitec | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

ILPA100VU SERIES 100W Water-Proof Constant Voltage LED Driver – Wide Input Voltage 90 to 305VAC, 47 to 63Hz – Constant Output Voltage Available From 12VDC Thru 105VDC – Over Voltage, Over Current, Short Circuit, Lighting, and Over Temperature Protection – High Efficiency (up to 93%) – Active Power Factor Correction (PFC) (99% typical) – IP67 Waterproof Rating, Metal Housing – Comply with UL8750 & EN61347 Safety Regulation (Pending)

3 Year Warranty Approvals:

Part Number Output Voltage Max. Output Current Efficiency (220VAC, Full Load) Over Voltage Protection Min / Typ / Max Max. Output Power ILPA100VU-S012ST 12 VDC 8.33 A 91% 14V / 15V / 16V 100W ILPA100VU-S024ST 24 VDC 4.05A 93% 27V / 30V / 34V 100W ILPA100VU-S036ST 36 VDC 2.75 A 93% 40V / 47V / 50V 100W ILPA100VU-S042ST 42 VDC 2.25 A 93% 47V / 52V / 57V 100W ILPA100VU-S048ST 48 VDC 1.95 A 92% 54V / 59V / 63V 100W ILPA100VU-S054ST 54 VDC 1.75 A 93% 60V / 68V / 75V 100W ILPA100VU-S081ST 81 VDC 1.23 A 93% 91V / 95V / 100V 100W ILPA100VU-S105ST 105 VDC 0.95 A 93% 120V / 125V / 140V 100W

Electrical Characteristics

Parameter Test Conditions Min. Typ. Max. Unit Input Voltage Operating Voltage 90 305 VAC Input Frequency 47 63 Hz Output Power Range Vin=90 to 264VAC 0 100 W Input Current (Low Line) Io=Full load, Vin=115VAC 1.20 A Input Current (High Line) Io=Full load, Vin=230VAC 0.60 A High Line Inrush Current Io=Full load, 25° C, Cool start, Vin=230VAC 65 A Power Factor Correction Vin=110VAC 99 % Power Factor Correction Vin=220VAC 96 % Efficiency Io=Full Load, Vin=230VAC 93 % No-Load Power Consumption No Load, VIn=230VAC 1.5 W Line Regulation Io=Full Load 1 % Load Regulation Vin=230VAC 2 % Over Voltage Protection Latch mode. The power unit shall return to normal operation only after the power is turn-on again. (Please refer to output table.) Over Current Protection 110 135 180 % Io Over Temperature Protection 110 °C Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. Output Overshoot / Undershoot When power on or off 10 % Start Up Time Io=Full Load, Vin=100VAC 3 S Ripple & Noise (Peak to Peak) Measured by 20 MHz bandwidth oscilloscope and the output paralleled a 0.1 uF ceramic capacitor and a 10 uF electrolytic capacitor. 2 % Vo

Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature -35 70 °C Storage Temperature -40 85 °C Relative Humidity 5 95 % Operation temperature at 25° C, calculated per MIL-HDBK-217F 0.439M Hours Life Time at 25° C ambient temperature 0.193M Hours No output power derating from -35° C to 60° C Approvals and Compliance Parameter Standards EMI EN55015 EMS EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4.3, , EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-1-1, EN61547 No.250.0, EN61347-1,EN61347-2-13 Waterproof IP67 Rating Mechanical Parameter Specification Input Electric Wire 650mm, Black(ACL), White(ACN), Green(GND) Output Electric Wire 220mm, Red(V+), Black(V-)