125 Watts

  • Small Size - 3.0” x 5.0” x 1.25”
  • Triple and Quad Outputs
  • Active PFC - Meets EN61000-3-2, -3
  • Overvoltage & Overcurrent Protection
  • Power Good Signal
  • -25 °C to +50 °C Full Power
  • 3 Year Warranty IFC125 Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 0.8 A max at 240 VAC

1.8 A max at 100 VAC

Inrush Current • 33 A max at 115 VAC

66 A max at 230 VAC

Power Factor • 0.98 typical Earth Leakage Current• 0.5 mA max at 132 VAC/60Hz 0.825 mA max at 264 VAC/50Hz Input Protection • Internal 2.6 A fuse Output Output Voltage • See table Output Voltage Trim • Not user-adjustable Initial Set Accuracy • ±5% maximum Minimum Load • 5 W minimum load on V1 or V2 required to maintain regulation Start Up Delay • 1.5 s at 90 VAC Start Up Rise Time • 0.2-20 ms Hold Up Time • >28 ms min at full load Line Regulation • See table Load Regulation • See table Over/Undershoot • 10% maximum Transient Response • 5% max. deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise • ±1% pk-pk maximum or ≤5 Vout 50 mV maximum Overvoltage Protection• V1 & V2: 113-148%, auto recovery Overtemperature • Unit shuts down, recycle input to reset Protection Overload Protection • All outputs: 115-135%, auto recovery Short Circuit Protection• Trip and restart (Hiccup mode) Temperature • 0.04% / ˚C maximum Coefficient Remote Sense • V1 only compensates for 0.5 V drop (not available on IFC125-31) xppower.com General Efficiency • 83% typical Isolation • 3000 VAC Input to Output

1500 VAC Input to Ground

500 VAC Output to Ground

Power Density • 6.66 W/In3 Signals • Power Good - On = Logic High MTBF • >220 kHrs per Bellcore Environmental Operating Temperature• -25 ˚C to +70 ˚C, derate linearly from 100% at +50 ˚C to 50% at +70 ˚C Cooling • 5 CFM airflow required for 125 W Operating Humidity • 5-95% RH, non-condensing Storage Temperature • -40 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • 15 G pk operating Vibration • 2.4 G, 5 Hz to 500 Hz, 3 axis EMC & Safety Emissions • EN55022/CISPR22 and FCC, Class B conducted Harmonic Currents • EN61000-3-2 Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria B EFT/Burst • EN61000-4-4, level 3 Perf Criteria B Surge • EN61000-4-5, level 3 Perf Criteria B Conducted Immunity • EN61000-4-6 Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Criteria A, B, B Safety Approvals • EN60950, UL 60950, CSA950 per cUL, CE Mark LVD AC-DC

1 Neutral Neutral

3 Line Line

3 Not Used +3.3 VDC 4 Not Used +3.3 VDC 5 Not Used +3.3 VDC

6 DC GND DC GND

7 DC GND DC GND

8 DC GND DC GND

9 DC GND DC GND

10 DC GND DC GND

2 Not Used +3.3 V Sense

3 Power Good Power Good

Output 1 Output 2 Output 3 Output 4 Model NumberVnom Imax Reg (1) Vnom Imax Reg (1) Vnom Imax Reg (1) Vnom Imax Reg (1) Notes 1. Total regulation includes tolerance, line regulation and load regulation. 2. Maximum output power not to exceed 125W with 5 CFM forced air or 70W with convection cooling. 3. For IFC125-42-3, a maximum of 80W combined +3.3V and +5V outputs with 5CFM of forced air cooling or 40W with convection cooling. Mechanical Details Notes 1. All dimensions in inches (mm). 2. Weight 0.68 lb (310 g) approx (-14 models 0.6 lb, 270g). Molex Mating Connectors J1 Housing 09-50-8031 Pins 08-52-0113 J2 Housing 09-50-8141 Pins 08-52-0113 J3 Housing 22-01-3037 Pins 08-50-0123 Screws shown for reference only Lock washer 5.00 (127.0) 3.00 (76.2) 3.00 (76.2) 4.55 (115.6) 2.55 (64.8) Ø 0.16 (4.1) (4 places) Safety ground connection point Pin #1 Pin #1 Pin #1 Fastener clearance area (4 places) 1.00 (25.4)1.25 (31.8) 0.06 (1.5) 0.19 (4.8) J1 - Input connector J3 - Remote Sense/ PG connector PCB J2 - DC output connector for IFC125-31, -40-1, 42-3. (see pin-out table) 0.23 (5.7)