IES01_V01 XPPOWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
Features
- Unregulated single output
- ±10% input range
- Single outputs 3.3 to 24VDC
- SMD8 DIP package
- 1.5kVDC isolation, 3kVDC option
- UL62368-1 safety approvals(3)
- Continuous short circuit protection
- Operating temperature -40°C to +105°C
- Full load to 100°C
- 3 year warranty LaboratoryInstrumentationIndustry 4.0
DC-DC CONVERTERIES01 Series Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 3.3 24 VDC See models and ratings table Initial Set Accuracy See Load Regulation curves Minimum Load 10 % Line Regulation ±1.2 /±1.5 % Per ±1% change of input voltage Others / 3V3 output Load Regulation See Load Regulation curves Ripple and Noise 30/50 75/100 mV pk-pk For models ≤15V/24V output,
20 MHz bandwidth, measured using 10µF capacitor at +25°C
Short Circuit Protection Continuous, with auto recovery Maximum Capacitive Load See Models and Ratings table Temperature Coefficient ±0.02 %/°C Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 2.97 26.4 VDC See models and ratings table Input Reflected Ripple 15/30 63 mA pk-pk Through 4.7µH inductor and 220 µF capacitor, others / 3V3 input Input Surge VDC IES0103 for max 1s
9 IES0105 for max 1s
18 IES0112 for max 1s
21 IES0115 for max 1s
30 IES0124 for max 1s
Input Current See models and ratings table Input Filter Capacitor See Models and Ratings tabl General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency See Models and Ratings table Isolation: Input to Output 1500/3000 VDC IES/IES-H functional Switching Frequency 240 270 275 kHz Low input voltage 10% load to high input voltage at full load 195 220 245 3V3 input Isolation Resistance 109 Ω Input to output, tested at 500VDC Isolation Capacitance 20 pF Input to output Power Density 20.8 W/in3 Mean Time Between Failure 3500 khrs MIL-HDBK-217F , 25°C GB. Weight 0.003 (1.4) lb(g) Recommended Solder Profile IPC/JEDEC J-STD-020D.1, peak temp ≤245°C, max duration, ≤60s at 217°C MSL Level 1 Case Material Black plastic, flame retardant UL94V-0 Pin Material Phosphor bronze, solder coated Water Wash Non-soaking water wash with de-ionised water. Dry thoroughly.
DC-DC CONVERTERIES01 Series Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature -40 +105 °C Derate from 100% load at +100°C to 80% load at 105°C. For 3V3 input derate from +85°C. Storage Temperature -55 +125 °C Case Temperature +115 °C Ambient +85°C Case Temperature Rise 25/15 °C Ambient 25°C , 3V3 output/others Operating Humidity 95 %RH Non-condensing Cooling Natural convection Mechanical Details 1. All dimensions are in inches (mm). 2. Weight: 0.003lbs (1.4g) typical. 3. Pin pitch and length tolerance: ±0.01 (±0.25). 4. Case tolerance: ±0.02 (±0.5). 5. Pin 8 leave floating. Notes: Pin Connections Pin Function 1 -Vin 2 +Vin 4 -Vout 5 +Vout
8 No Connection(5)
A 0.037 (0.95) 0.016 (0.40) Recommended Footprint 0.100 (2.54) 0.100 (2.54) 0.010 (0.25) 0.480 (12.20) 0.039 (1.00) A 5. 00 º 0.016 (0.40) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm) 14 2 0.100 (2.54) 0.010 (0.25) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View Side View 12 4 0.10 A 0.037 (0.95) 0.016 (0.40) Recommended Footprint 0.100 (2.54) 0.100 (2.54) 0.010 (0.25) 0.480 (12.20) 0.039 (1.00) A 5. 00 º 0.016 (0.40) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm) 14 2 0.100 (2.54) 0.010 (0.25) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View Side View 12 4 0.10 A 0.037 (0.95) 0.016 (0.40) Recommended Footprint 0.100 (2.54) 0.100 (2.54) 0.010 (0.25) 0.480 (12.20) 0.039 (1.00) A 5. 00 º 0.016 (0.40) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm) 14 2 0.100 (2.54) 0.010 (0.25) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View Side View 12 4 0.10 A 0.037 (0.95) 0.016 (0.40) Recommended Footprint 0.100 (2.54) 0.100 (2.54) 0.010 (0.25) 0.480 (12.20) 0.039 (1.00) A 5. 00 º 0.016 (0.40) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View grid: 0.1 x 0.1 in (2.54 x 2.54 mm) 14 2 0.100 (2.54) 0.010 (0.25) 0.024 (0.60) 0.449±0.012 (11.40±0.30) 0.335 (8.50) 0.285 (7.25) 0.276 (7.00) 0.520±0.020 (13.20±0.5) 0.300 (7.62) Top View Side View 12 4 0.10
DC-DC CONVERTERIES01 Series EMC: Emissions Phenomenon Standard T est Level Notes & Conditions Conducted EN55032 Class B See Application Note for Class B filter Radiated EN55032 Class B EMC: Immunity Phenomenon Standard T est Level Criteria Notes & Conditions ESD Immunity EN61000-4-2 ±4kV contact / ±8kV air discharge B Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 5V input series Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 3V3 input series 3V3 & 5V input series
DC-DC CONVERTERIES01 Series Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 3V3/5V Input: Output Voltage C1, C2 C3 C4 L 3V3 4.7µF , 25V 10µF , 16V Not fitted 6.8µH 5V 10µF , 16V 9V 2.2µF , 25V 12V 2.2µF , 25V 1nF15V 1µF , 25V 24V 0.47µF , 50V Other Input Series: Output Voltage C1, C2 C3 C4 L 3V3/5V 4.7µF , 50V 10µF , 16V 270pF 6.8µH 9V 2.2µF , 16V 12V 2.2µF , 25V 15V 1µF , 25V 24V 1µF , 50V Other Input Series Application NotesApplication Notes EMI Filter for Class B Emissions IES01 +Vout C3 Load -Vout +Vin -Vin L C1 C2 C4: 2kV, ceramic. Upgrade C4 to 4kV for 3kV isolation option -H. C4: 2kV, ceramic. Upgrade C4 to 4kV for 3kV isolation option -H.
21 Apr 2023
T emperature Derating Curve Efficiency vs Input Voltage (IES0105S05) Efficiency vs Output Load (IES0105S05) Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 Efficiency Vs Input Voltage (Full Load) Efficiency Vs Input Voltage (Full Load ) 100 Efficiency (% ) Input Voltage (V) Full load Vin=5V Output Current Percentage (% ) 100 Efficiency (% ) Efficiency Vs Input Voltage (Full Load ) -4 00 40 80 100 105 Ambient Temperature (°C) 100 Output Power (% ) 10 20 Load (% ) For 3.3 V output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102 100 105 112 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Typical Load Curve 40 60 80 100 102.5 97.5 92.5 100 105 110 10 20 Load (% ) Other output models Output Voltage Accuracy (% ) Max. Typical Min. 40 60 80 100 102.5 97.5 92.5 103 108 Safety Approvals Safety Agency Standard Notes & Conditions UL UL62368-1 CE Meets all applicable directives UKCA Meets all applicable legislation