IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 1 of 32 1-888-824-4184

FEATURES

  • Form, Fit, and Function Compatible with the Intelâ 8X44
  • Packaging options available: 40 Pin Plastic Dual In-Line Package (PDIP), 44 Pin Plastic Leaded Chip Carrier (PLCC)
  • 8-Bit Control Unit
  • 8-Bit Arithmetic-Logic Unit with 16-Bit multiplication and division
  • 12 MHz clock
  • Four 8-Bit Input / Output ports
  • Two 16-Bit Timer/Counters
  • Serial Interface Unit with SDLC/HDLC compatibility
  • 2.4 Mbps maximum serial data rate
  • Two Level Priority Interrupt System
  • 5 Interrupt Sources
  • Internal Clock prescaler and Phase generator
  • 192 Bytes of Read/Write Data Memory Space
  • 64kB External Program Memory Space
  • 64kB External Data Memory Space
  • 4kB Internal ROM (IA8044 only) IA8044/IA8344 Variants IA8044 4kB internal ROM with R0117 version 2.1 firmware, 192 byte internal RAM (Expandable to 256 Bytes), 64kB external program and data space. IA8344 192 byte internal RAM, 64kB external program and data space. The IA8044/IA8344 is a "plug -and-play" drop-in replacement for the original IC. innov ASIC produces replacement ICs using its MILESTM, or Managed IC Lifetime Extension System, cloning technology. This technology produces replacement ICs far more complex than "emulation" while ensuring they are compatible with the original IC. MILES TM captures the design of a clone so it can be produced even as silicon technology advances. MILES TM also verifies the clone against the original IC so that even the "undocumented features" are duplicated. This data sheet documents all necessary engineering information about the IA8044/IA8 344 including functional and I/O descriptions, electrical characteristics, and applicable timing.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 2 of 32 1-888-824-4184 Package Pinout (6)P1.5 (1)P1.0 (2)P1.1 (3)P1.2 (4)P1.3 (5)P1.4 (7)(RTS) P1.6 (8) (9)RST (10) (11) (12)(INT0) P3.2 (13)(INT1) P3.3 (14)

40 Pin DIP

P0.7 (AD7) EA ALE PSEN (20)VSS (15)(SCLK/T1) P3.5 (16)(WR) P3.6 (17)(RD) P3.7 (18)XTAL2 (19)XTAL1 (21) (22) (23) (24) P2.1 (A9) P2.0 (A8) (40) (39) (38) (37) (36) (35) (34) (33) (32) (31) (30) (29) (28) (27) (26) (25) (T0) P3.4 P2.3 (A11) P2.2 (A10) P2.5 (A13) P2.4 (A12) P2.7 (A15) P2.6 (A14) P0.5 (AD5) P0.6 (AD6) P0.3 (AD3) P0.4 (AD4) P0.1 (AD1) P0.2 (AD2) VCC P0.0 (AD0) (CTS) P1.7 (RXD) P3.0 (TXD) P3.1 P1.3 P1.4P3.6 P2.6

44 Pin LCC

(12)N.C. (7)P1.5 (8)P1.6 (9)P1.7 (10)RST/VPD (11)P3.0 (13)P3.1 (14)P3.2 (15)P3.3 (16)P3.4 (17)P3.5 P0.4 ALE N.C. EA P0.6 P0.5 XTAL2 P3.7 (6) (5) (4) (3) (2) (1) (44) (43) (42) P0.1 (41) P0.2 (40) P0.3 (34) (39) (38) (37) (36) (35) (33) (32) (31) (30) (29) (18) (19) (20) (21) (22) (23) (24) (25) (26) (27) (28) VCC P0.0 P1.0 N.C. P1.2 P1.1 VSS XTAL1 P2.0 N.C. P2.2 P2.1 P2.4 P2.3 P2.5 P2.7 PSEN P0.7

DESCRIPTION

The IA8044/IA8344 is a form, fit and function compatible part to the Intel  8X44 SDLC communications controller. The IA8044/IA8344 is a Fast Single -Chip 8-Bit Microcontroller with an integrated SDLC/HDLC serial interface controller. The IA8044/IA8344 is a fully functional 8 - Bit Embedded Controller that executes all ASM51 instructions and has th e same instruction set as the Intel 80C51. The IA8044/IA8344 can access the instructions from two types of program memory, serves software and hardware interrupts, provides an interface for serial communications and a timer system. The IA8044/IA8344 is f ully compatible with the Intel  8X44 series . The functional block diagram is shown below.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 3 of 32 1-888-824-4184 Functional Block Diagram 192x8Dual Port RAM C8051 CPU Interrupts Timers Port 0 ADDR/DATA/IO Port 2 ADDR/DATA/IO Port 1 SPCL FUNC/IO Port 3 SPCL FUNC/IO SIU Control Address/Data Clock Gen. & Timing XTAL Reset Memory Control I/O for Memory, SIU, DMA, Interrupts, Timers

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 4 of 32 1-888-824-4184 I/O Characteristics The table below describes the I/O characteristics for each signal on the IC. The s ignal names correspond to the signal names on the pinout diagrams provided . The table below provides the I/O description of the IA8044 and the IA8344. Name Type Description RST I Reset. This pin when held high for two machine cycles while the oscillat or is running will cause the chip to reset. ALE O Address Latch Enable. Used to latch the address on the falling edge for external memory accesses. PSEN O Program Store Enable. When low acts as an output enable for external program memory. EA I External Access. When held low EA will cause the IA8044/IA8344 to fetch instructions from external memory. P0.7 – P0.0 I/O Port 0. 8 bit I/O port and low order multiplexed address/data byte for external accesses. (RTS) and P1.7 (CTS). P2.7 – P2.0 I/O Port 2. 8 bit I/O port. It also functions as the high order address byte during external accesses. P3.7 – P3.0 I/O Port 3. 8 bit I/O port. Port 3 bits also have alternate functions as described below. P3.0 – RXD. Receive data input for SIU or direction control for P3.1 dependent upon datalink configuration. P3.1 – TXD. Transmit data output for SIU or data input/output dependent upon datalink configuration. Also enables diagnostic mode when cleared. P3.2 – INT0. Interrupt 0 input or gate control input for counter 0. P3.3 – INT1. Interrupt 1 input or gate control input for counter 1. P3.4 – T0. Input to counter 0. P3.5 – SCLK/T1. SCLK input to SIU or input to counter 1. P3.6 – WR. External memory write signal. P3.7 – RD. External memory read signal. XTAL1 I Crystal Input 1. Connect to VSS when external clock is used on XTAL2. May be connected to a crystal (with XTAL2), or may be driven directly with a clock source (XTAL2 not connected). XTAL2 O Crystal Input 2. May be connected to a crystal (with XTAL1), or may be driven directly with an inverted clock source (XTAL1 tied to ground). VSS P Ground. VCC P +5V power.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 5 of 32 1-888-824-4184 Memory Organization Program Memory Program Memory includes interrupt and Reset vectors. The interrupt vectors are spaced at 8 - byte intervals, starting from 0003H for External Interrupt 0. Reset Vectors These locations may be used for program code, if the corresponding interrupts are not used (disabled). The Program Memory space is 64K, from 0000H to FFFFH. The lowest 4K of program code (0000H to 0FFFH) ca n be fetched from external or internal Program Memory. This selection is made by strapping pin ‘EA’ (External Address) to GND or VCC. If during reset, ‘EA’ is held low, all the program code is fetched from external memory. If, during reset, ‘EA’ is held high, the lowest 4K of program code (0000H to 0FFFH) is fetched from internal memory (ROM). Data Memory External Data Memory The IA8044/IA8344 Microcontroller core incorporates the Harvard architecture, with separate code and data spaces. The code from ex ternal memory is fetched by ‘psen’ strobe, while data is read from RAM by bit 7 of P3 (read strobe) and written to RAM by bit 6 of P3 (write strobe). The External Data Memory space is active only by addressing through use of the 16 bit Data Pointer Register (DPTR). A smaller subset of external data memory (8 bit addressing) may be accessed by using the MOVX instruction with register indexed addressing. Location Service 0003H External Interrupt 0 000BH Timer 0 overflow 0013H External Interrupt 1 001BH Timer 1 overflow 0023H SIU Interrupt

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 6 of 32 1-888-824-4184 Internal Data Memory The Internal Data Memory address is always 1 byte wide. The memory space is 192 byt es large (00H to BFH), and can be accessed by either direct or indirect addressing. The Special Function Registers occupy the upper 128 bytes. This SFR area is available only by direct addressing. Internal memory which overlaps the SFR address space is on ly accessible by indirect addressing. Internal Memory

8044 Internal Data Memory Addresses

(128 BITS)

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 7 of 32 1-888-824-4184 Bit Addressable Memory Both the internal RAM and the Special Function Registers have locations that are bit addressable in addition to the byte addressable locations. SFR Bit Addressable Locations Byte Address bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 Register F0h F7h F6h F5h F4h F3h F2h F1h F0h B E0h E7h E6h E5h E4h E3h E2h E1h E0h ACC D8h DFh DEh DDh DCh DBh DAh D9h D8h NSNR D0h D7h D6h D5h D4h D3h D2h D1h D0h PSW C8h CFh CEh CDh CCh CBh CAh C9h C8h STS B8h BFh BEh BDh BCh BBh BAh B9h B8h IP B0h B7h B6h B5h B4h B3h B2h B1h B0h P3 A8h AFh AEh ADh ACh ABh AAh A9h A8h IE A0h A7h A6h A5h A4h A3h A2h A1h A0h P2 90h 97h 96h 95h 94h 93h 92h 91h 90h P1 88h 8Fh 8Eh 8Dh 8Ch 8Bh 8Ah 89h 88h TCON 80h 87h 86h 85h 84h 83h 82h 81h 80h P0 Internal RAM Bit Addressable Locations Byte Address bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 30h-BFh Upper Internal Ram locations 2Fh 7Fh 7Eh 7Dh 7Ch 7Bh 7Ah 79h 78h 2Eh 77h 76h 75h 74h 73h 72h 71h 70h 2Dh 6Fh 6Eh 6Dh 6Ch 6Bh 6Ah 69h 68h 2Ch 67h 66h 65h 64h 63h 62h 61h 60h 2Bh 5Fh 5Eh 5Dh 5Ch 5Bh 5Ah 59h 58h 2Ah 57h 56h 55h 54h 53h 52h 51h 50h 29h 4Fh 4Eh 4Dh 4Ch 4Bh 4Ah 49h 48h 28h 47h 46h 45h 44h 43h 42h 41h 40h 27h 3Fh 3Eh 3Dh 3Ch 3Bh 3Ah 39h 38h 26h 37h 36h 35h 34h 33h 32h 31h 30h 25h 2Fh 2Eh 2Dh 2Ch 2Bh 2Ah 29h 28h 24h 27h 26h 25h 24h 23h 22h 21h 20h 23h 1Fh 1Eh 1Dh 1Ch 1Bh 1Ah 19h 18h 22h 17h 16h 15h 14h 13h 12h 11h 10h 21h 0Fh 0Eh 0Dh 0Ch 0Bh 0Ah 09h 08h 20h 07h 06h 05h 04h 03h 02h 01h 00h 18h-1Fh Register Bank 3 10h-17h Register Bank 2 08h-0Fh Register Bank 1 00h-07h Register Bank 0

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 8 of 32 1-888-824-4184 Instruction Set The 8X44 architecture and instruction set are identical to the 8051’s. The following tables give a survey of the instruction set of the IA8044/IA8344 Microcontroller core. Arithmetic Operations Mnemonic ADD A,Rn Add register to accumulator 1 1 ADD A, direct Add direct byte to accumulator 2 1 ADD A,@Ri Add indirect RAM to accumulator 1 1 ADD A,#data Add immediate data to accumulator 2 1 ADDC A,Rn Add register to accumulator with carry flag 1 1 ADDC A,direct Add direct byte to A with carry flag 2 1 ADDC A,@Ri Add indirect RAM to A with carry flag 1 1 ADDC A,#data Add immediate data to A with carry flag 2 1 SUBB A,Rn Subtract register from A with borrow 1 1 SUBB A,direct Subtract direct byte from A with borrow 2 1 SUBB A,@Ri Subtract indirect RAM from A with borrow 1 1 SUBB A,#data Subtract immediate data from A with borrow 2 1 INC A Increment accumulator 1 1 INC Rn Increment register 1 1 INC direct Increment direct byte 2 1 INC @ Ri Increment indirect RAM 1 1 DEC A Decrement accumulator 1 1 DEC Rn Decrement register 1 1 DEC direct Decrement direct byte 2 1 DEC @Ri Decrement indirect RAM 1 1 INC DPTR Increment data pointer 1 2 MUL A,B Multiply A and B 1 4 DIV A,B Divide A by B 1 4 DA A Decimal adjust accumulator 1 1

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 9 of 32 1-888-824-4184 Logic Operations Mnemonic ANL A,Rn AND register to accumulator 1 1 ANL A,direct AND direct byte to accumulator 2 1 ANL A,@Ri AND indirect RAM to accumulator 1 1 ANL A,#data AND immediate data to accumulator 2 1 ANL direct,A AND accumulator to direct byte 2 1 ANL direct,#data AND immediate data to direct byte 3 2 ORL A,Rn OR register to accumulator 1 1 ORL A,direct OR direct byte to accumulator 2 1 ORL A,@Ri OR indirect RAM to accumulator 1 1 ORL A,#data OR immediate data to accumulator 2 1 ORL direct,A OR accumulator to direct byte 2 1 ORL direct,#data OR immediate data to direct byte 3 2 XRL A,Rn Exclusive OR register to accumulator 1 1 XRL A,direct Exclusive OR dire ct byte to accumulator 2 1 XRL A,@Ri Exclusive OR indirect RAM to accumulator 1 1 XRL A,#data Exclusive OR immediate data to accumulator 2 1 XRL direct,A Exclusive OR accumulator to direct byte 2 1 XRL direct,#data Exclusive OR immediate data to direct byte 3 2 CLR A Clear accumulator 1 1 CPL A Complement accumulator 1 1 RL A Rotate accumulator left 1 1 RLC A Rotate accumulator left through carry 1 1 RR A Rotate accumulator right 1 1 RRC A Rotate accumulator r ight through carry 1 1 SWAP A Swap nibbles within the accumulator 1 1

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 10 of 32 1-888-824-4184 Data Transfer Mnemonic MOV A,Rn Move register to accumulator 1 1 MOV A,direct Move direct byte to accumulator 2 1 MOV A,@Ri Move indirect RAM to accumulator 1 1 MOV A,#data Move immediate data to accumulator 2 1 MOV Rn,A Move accumulator to register 1 1 MOV Rn,direct Move direct byte to register 2 2 MOV Rn,#data Move immediate data to register 2 1 MOV direct,A Move accumulator to direct byte 2 1 MOV direct,Rn Move register to direct byte 2 2 MOV direct,direct Move direct byte to direct byte 3 2 MOV direct,@Ri Move indirect RAM to direct byte 2 2 MOV direct,#data Move immediate data to direct by te 3 2 MOV @Ri,A Move accumulator to indirect RAM 1 1 MOV @Ri,direct Move direct byte to indirect RAM 2 2 MOV @ Ri, #data Move immediate data to indirect RAM 2 1 MOV DPTR, #data16 Load data pointer with a 16 -bit constant 3 2 MOVC A,@A + DPTR Move code byte relative to DPTR to accumulator 1 2 MOVC A,@A + PC Move code byte relative to PC to accumulator 1 2 MOVX A,@Ri Move external RAM (8 -bit addr.) to A 1 2 MOVX A,@DPTR Move external RAM (16 -bit addr.) to A 1 2 MOVX @Ri,A Move A to external RAM (8 -bit addr.) 1 2 MOVX @DPTR,A Move A to external RAM (16 -bit addr.) 1 2 PUSH direct Push direct byte onto stack 2 2 POP direct Pop direct byte from stack 2 2 XCH A,Rn Exchange register with accumulator 1 1 XCH A,direct Exchange direct byte with accumulator 2 1 XCH A,@Ri Exchange indirect RAM with accumulator 1 1 XCHD X,@ Ri Exchange low-order nibble indir. RAM with A 1 1

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 11 of 32 1-888-824-4184 Boolean Manipulation Mnemonic CLR C Clear carry flag 1 1 CLR bit Clear direct bit 2 1 SETB C Set carry flag 1 1 SETB bit Set direct bit 2 1 CPL C Complement carry flag 1 1 CPL bit Complement direct bit 2 1 ANL C,bit AND direct bit to carry flag 2 2 ANL C,bit AND complement of direct bit to carry 2 2 ORL C,bit OR direct bit to carry flag 2 2 ORL C,bit OR complement of direct bit to carry 2 2 MOV C,bit Move direct bit to carry flag 2 1 MOV bit,C Move carry flag to direct bit 2 2 Program Branches Mnemonic ACALL addr11 Absolute subroutine call 2 2 LCALL addr16 Long subroutine call 3 2 RET Return from subroutine 1 2 RETI Return from interrupt 1 2 AJMP addr11 Absolute jump 2 2 LJMP addr16 Long jump 3 2 SJMP rel Short jump (relative addr.) 2 2 JMP @A + DPTR Jump indirect relative to the DPTR 1 2 JZ rel Jump if accumulator is zero 2 2 JNZ rel Jump if accumulator is not zero 2 2 JC rel Jump if carry flag is set 2 2 JNC rel Jump if carry flag is not set 2 2 JB bit,rel Jump if direct bit is set 3 2 JNB bit,rel Jump if direct bit is not set 3 2 JBC bit,rel Jump if direct bit is set and clear bit 3 2 CJNE A,direct,rel Compare direct byte to A and jump if not equal 3 2 CJNE A,#data,rel Compare immediate to A and jump if not equal 3 2 CJNE Rn,#data rel Compare immed. to reg. and jump if not equal 3 2 CJNE @Ri,#data,rel Compare immed. to ind. and jump if not equal 3 2 DJNZ Rn,rel Decrement register and jump if not zero 2 2 DJNZ direct,rel Decrement direct byte and jump if not zero 3 2 NOP No operation 1 1

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 12 of 32 1-888-824-4184 Special Function Registers The IA8044/IA8344 contains the following special function registers: ACC Accumulator B B register * PSW program Status Word * SP Stack Pointer DPTR Data Pointer (DPH and DPL) P0 Port 0 * P1 Port 1 * P2 Port 2 * P3 Port 3 * IP Interrupt Priority * IE Interrupt Enable * TMOD Timer/Counter Mode TCON Timer/Counter Control * TH0 Timer/Counter 0 high byte TL0 Timer/Counter 0 low byte TH1 Timer/Counter 1 high byte TL1 Timer/Counter 1 low byte SMD Serial Mode STS SIU Status and Command * NSNR SIU Send/Receive Count * STAD SIU Station Address TBS Transmit Buffer Start Address TBL Transmit Buffer Length TCB Transmit Control Byte RBS Receive Buffer Start Address RBL Receive Buffer Length RFL Receive Field Length RCB Receive Control Byte DMA CNT DMA Count FIFO FIFO contents (3 bytes) SIUST SIU State Counter * - These registers are bit addressable. Ports Ports P0, P1, P2 and P3 are Special Function Registers. The contents of the SFR can be observed on corresponding pins on the chip. Writing a ‘1’ to any of the ports causes the corresponding pin to be at high level (VCC), and writing a ‘0’ causes the corresponding pin to be held at low level (GND). All four ports on the chip are bi-directional. Each of them consists of a Latch (SFR P0 to P3), an output driver, and an input buffer, so the CPU can outpu t or read data through any

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 13 of 32 1-888-824-4184 of these ports if they are not used for alternate purposes. Ports P0, P1, P2 and P3 can perform some alternate functions. Ports P0 and P2 are used to access external memory. In this case, port ‘p0’ outputs the multiplexed lower 8 bits of address with ‘ale’ strobe high and then reads/writes 8 bits of data. Port P2 outputs the higher 8 bits of address. Keeping ‘ea’ pin low (tied to GND) activates this alternate function for ports P0 and P2. Port P3 and P1 can perform some alternat e functions. The pins of Port P3 are multifunctional. They can perform additional functions as shown below. Pin Symbol Function P3.0 RxD Serial input pin. Setting the appropriate bits in the Special Function Register SCON activates this function. Se rial input data at pin P3.0 is strobed to the serial input register and can then be read by the CPU from the Special Function Register SBUF. P3.1 TxD Serial output pin. Setting the appropriate bits in the Special Function Register SCON and writing data to be transmitted to the Special Function Register SBUF activates this function. Note that SBUF is used to read and transmit data. The function it performs is determined by the CPU operation (read or write). P3.2 INT0 External interrupt 0 is activated o n the falling edge by setting the appropriate bits in Special Function Register IE (Interrupt Enable) P3.3 INT1 External interrupt 1 is activated on the falling edge by setting the appropriate bits in the Special Function Register IE (Interrupt Enable) P3.4 T0 Timer/Counter 0 external input. Setting the appropriate bits in the Special Function Registers TCON and TMOD activates this function. P3.5 T1 Timer/Counter 1 external input. Setting the appropriate bits in the Special Function Registers TCON and TMOD activates this function. P3.6 WR External Data Memory write strobe, active LOW. This function is activated by a CPU write access to External Data Memory (MOV @DPTR, A). P3.7 RD External Data Memory read strobe, active LOW. This function is activated by a CPU read access to External Data Memory (MOV A, @DPTR). P1.6 RTS Request To Send output. P1.7 CTS Clear To Send input.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 14 of 32 1-888-824-4184 Timers/Counters Timers 0 and 1 The C8051 has two 16 -bit timer/counter registers: Timer 0 and Timer 1. Both can be configured for counter or timer operations. In timer mode, the register is incremented every machine cycle, which means that it counts up after every 12 oscillator periods. In counter mode, the register is incremented when the falling edge is observed a t the corresponding input pin T0 or T1. Since it takes 2 machine cycles to recognize a 1 -to-0 event, the maximum input count rate is 1/24 of the oscillator frequency. There are no restrictions on the duty cycle, however to ensure proper recognition of 0 or 1 state, an input should be stable for at least 1 machine cycle (12 clock periods). Four operating modes can be selected for Timer 0 and Timer 1. Two Special Function Registers (TMOD and TCON) are used to select the appropriate mode.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 15 of 32 1-888-824-4184 Reset A reset is ac complished by holding the RST pin high for at least two machine cycles (24 oscillator periods) while the oscillator is running. The CPU responds by generating an internal reset, which is executed during the second cycle in which RST is high. The internal reset sequence writes ‘0’s to all SFRs except the port -latches, the Stack Pointer, SIUST and unused bits of registers. Reset Values Register Reset value PC 0000H ACC 00000000B B 00000000B PSW 00000000B SP 00000111B DPTR 0000H P0 – P3 1111111 1B IP XXX00000B IE 0XX00000B TMOD 00000000B TCON 00000000B TH0 00000000B TL0 00000000B TH1 00000000B TL1 00000000B SMD 00000000B STS 00000000B NSNR 00000000B STAD 00000000B TBS 00000000B TBL 00000000B TCB 00000000B RBS 00000000B RBL 00000000B RFL 00000000B RCB 00000000B DMA CNT 00000000B FIFO1 00000000B FIFO2 00000000B FIFO3 00000000B SIUST 00000001B

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 16 of 32 1-888-824-4184 Interrupts The IA8044/IA8344 provides 5 interrupt sources. There are 2 external interrupts accessible through pins INT0 and INT1, edge or level sensitive (falling edge or low level). There are, also, internal interrupts associated with Timer 0 and Timer 1, and an internal interrupt from the SIU. External Interrupts The choice between external interrupt level or transition a ctivity is made by setting IT1 and IT0 bits in the Special Function Register TCON. When the interrupt event happens, a corresponding Interrupt Control Bit is set (IT0 or IT1). This control bit triggers an interrupt if the appropriate interrupt bit is enabl ed. When the interrupt service routine is vectored, the corresponding control bit (IT0 or IT1) is cleared provided that the edge triggered mode was selected. If level mode is active, the external requesting source controls flags IT0 or IT1 by the logic lev el on pins INT0 or INT1 (0 or 1). Timer0 and Timer 1 Interrupts Timer 0 and 1 interrupts are generated by TF0 and TF1 flags, which are set by the rollover of Timer 0 and 1, respectively. When an interrupt is generated, the flag that caused this interrupt is cleared by the hardware, if the CPU accessed the corresponding interrupt service vector. This can be done only if this interrupt is enabled in the IE register. Serial Interface Unit Interrupt The SIU generates an interrupt when a frame is received or transmitted. No interrupts are generated for a received frame with errors. Interrupt Priority Level Structure There are two priority levels in the IA8044/IA8344, and any interrupt can be individually programmed to a high or low priority level. Modifying the appropriate bits in the Special Function Register IP can accomplish this. A low priority interrupt service routine will be interrupted by a high priority interrupt. However, the high priority interrupt can not be interrupted. If two interrupts of the same priority level occur, an internal polling sequence determines which of them will be processed first. This polling sequence is a second priority structure defined as follows: IE0 1 – highest TF0 2 IE1 3 TF1 4 SIU – lowest

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 17 of 32 1-888-824-4184 Interrupt Handling The interrupt flags are sampled during each machine cycle. The samples are polled during the next machine cycle. If an interrupt flag is captured, the interrupt system will generate an LCALL instruction to the appropriate service routine, provided that this is n ot disabled by the following conditions: 1. An interrupt of the same or higher priority is processed 2. The current machine cycle is not the last cycle of the instruction (the instruction can not be interrupted). 3. The instruction in progress is RETI or a ny write to IE or IP registers. Note that if an interrupt is disabled and the interrupt flag is cleared before the blocking condition is removed, no interrupt will be generated, since the polling cycle will not sample any active interrupt condition. In oth er words, the interrupt condition is not remembered. Every polling cycle is new. SIU – Serial Interface Unit The SIU is a serial interface customized to support SDLC/HDLC protocol. As such it supports Zero Bit insertion/deletion, Flags automatic access r ecognition and a 16 bit CRC. The SIU has two modes of operation AUTO and FLEXIBLE. The AUTO mode uses a subset of the SDLC protocol implemented in hardware. This frees the CPU from having to respond to every frame but limits the frame types. In the FLE XIBLE mode every frame is under CPU control and therefore more options are available. The SIU is controlled by and communicates to the CPU by using several special function registers (SFRs). Data transmitted to or received by the SIU is stored in the 192 byte internal RAM in blocks referred to as the transmit and receive buffers. The SIU can support operation in one of three serial data link configurations: 1) half -duplex, point-to-point, 2) half-duplex, multipoint, 3) loop. SIU Special Function Regi sters The CPU controls the SIU and receives status from the SIU via eleven special function registers. The Serial Interface Unit Control Registers are detailed below:

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 18 of 32 1-888-824-4184 Serial Mode Register (SMD): The serial mode register sets the operational mode of th e SIU. The CPU can read and write SMD. The SIU can read SMD. To prevent conflicts between CPU and SIU accesses to SMD the CPU should write SMD only when RTS and RBE bits in the STS register are both zero. SMD is normally only accessed during initializa tion. This register is byte addressable. SMD (C9H) Bit: 7 6 5 4 3 2 1 0 SCM2 SCM1 SCM0 NRZ I LOO P PFS NB NFCS SMD.0 NFCS When set selects No FCS field contained in the SDLC frame. SMD.1 NB Non-buffered mode. No control field contained in SDLC frame . SMD.2 PFS Pre-frame sync mode. When set causes two bytes to be transmitted before the first flag of the frame for DPLL synchronization. If NRZI is set 00H is transmitted otherwise 55H. This ensures that 16 transitions are sent. SMD.3 LOOP When set selects loop configuration. SMD.4 NRZI When set selects NRZI encoding otherwise NRZ. SMD.5 SCM0 Select clock mode - bit 0. SMD.6 SCM1 Select clock mode - bit 1. SMD.7 SCM2 Select clock mode - bit 2. SMD Select Clock Mode Bits SCM 2 1 0 Clock Mode Data Rate (Bits/sec)* 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Externally clocked Undefined Self clocked, timer overflow Undefined Self clocked, external 16X Self clocked, external 32X Self clocked, internal fixed Self clocked, internal fix ed 0 – 2.4M** 244 – 62.5K 0 – 375K 0 – 187.5K 375K 187.5K * based on a12 MHz crystal frequency ** 0 – 1M bps in loop configuration

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 19 of 32 1-888-824-4184 Status/Command Register (STS): The Status/Command register provides SIU control from and status to the CPU. T he SIU can read the STS and can write certain bits in the STS. The CPU can read and write the STS. Accessing the STS by the CPU via 2 cycle instructions (JBC bit,rel and MOV bit,C) should not be used. STS is bit addressable. STS (C8H) Bit: 7 6 5 4 3 2 1 0 TBF RBE RTS SI BOV OPB AM RBP STS.0 RBP Receive buffer protect. When set prevents writing of data into the receive buffer. Causes RNR response instead of RR in AUTO mode. STS.1 AM Auto mode. If NB is cleared AM selects the AUTO mode when set. If NB is set AM selects the addressed mode when set. The SIU can clear AM. STS.2 OPB Optional poll bit. When set the SIU will AUTO respond to an optional poll (UP with P=0). The SIU can set or clear the OPB. STS.3 BOV Receive buffer overrun. Th e SIU can set or clear BOV. STS.4 SI SIU interrupt. This bit is set by the SIU and should be cleared by the CPU before returning from the interrupt routine. STS.5 RTS Request to send. This bit is set when the SIU is ready to transmit or is transmitti ng. May be written by the SIU in AUTO mode. STS.6 RBE Receive buffer empty. RBE is set by the CPU when it is ready to receive a frame or has just read the buffer. It is cleared by the SIU when a frame has been received. STS.7 TBF Transmit buffer full. TBF is set by the CPU to indicate that the transmit buffer is ready and cleared by the SIU.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 20 of 32 1-888-824-4184 Send/Receive count register (NSNR): The NSNR contains both the transmit and receive sequence numbers in addition to the tally error indications. The CPU can read and write the STS. Accessing the STS by the CPU via 2 cycle instructions (JBC bit,rel and MOV bit,C) should not be used. The SIU can read and write the NSNR. NSNR is bit addressable. NSNR (D8H) Bit: 7 6 5 4 3 2 1 0 NS2 NS1 NS0 SES NR2 NR1 NR0 SER NSNR.0 SER Sequence error receive. NS (P) ? NR (S). NSNR.1 NR0 Receive sequence counter, Bit 0. NSNR.2 NR1 Receive sequence counter, Bit 1. NSNR.3 NR2 Receive sequence counter, Bit 2. NSNR.4 SES Sequence error send. NR (P) ? NS ( S) and NR (P) ? NS (S) + 1. NSNR.5 NS0 Send sequence counter, Bit 0. NSNR.6 NS1 Send sequence counter, Bit 1. NSNR.7 NS2 Send sequence counter, Bit 2. Data Clocking Options The SIU may be clocked in one of two ways, with an external clock or in a se lf-clocked mode. In the external clocked mode a serial clock must be provided on SCLK. This clock must be synchronized to the serial data. Incoming data is sampled at the rising edge of SCLK. Outgoing data is shifted out at the falling edge of SCLK. In the self-clocked mode the SIU uses a reference clock and the serial data to reproduce the serial data clock. The reference clock can be an external source applied to SCLK, the IA8044/IA8344’s internal clock or the timer 1 overflow. The reference cloc k must be 16x or 32x the data rate. A DPLL uses the reference clock and the serial data to adjust the sample time to the center of the serial bit. It does this by adjusting from a serial data transition in increments of 1/16 of a bit time. The maximum data rate in the externally clocked mode is 2.4Mbps in half -duplex configuration and 1.0Mbps in a loop configuration. The maximum data rate in the self -clocked mode with an external clock is 375Kbps. The maximum data rate in the self -clocked mode with a n internal clock will depend on the frequency of the IA8044/IA8344’s input clock. An IA8044/IA8344 using a 12MHz input clock can operate at a maximum data rate of 375Kbps.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 21 of 32 1-888-824-4184 Operational Modes The SIU operates in one of two modes, AUTO or FLEXIBLE. Th e mode selected determines how much intervention is required by the CPU when receiving frames. In both modes short frames, aborted frames, and frames with CRC errors will be ignored. AUTO mode allows the SIU to recognize and respond to specific SDLC fram es without the CPUs intervention. This provides for a faster turnaround time but restricts the operation of the SIU. When in AUTO mode the SIU can only act as a normal response secondary station and responses will adhere to IBM’s SDLC definitions. When receiving in the AUTO mode the SIU receives the frame and examines the control byte. It will then take the appropriate action for that frame. If the frame is an information frame the SIU will load the receive buffer, interrupt the CPU and make the requir ed response to the primary station. The SIU in AUTO mode can also respond to the following commands from the primary station. RR (Receive ready), RNR (Receive Not Ready), REJ (Reject), UP (Unnumbered Poll) also called NSP (Non -Sequenced Poll) or ORP (Op tional Response Poll). In AUTO mode when the transmit buffer is full the SIU can transmit an information frame when polled for information. After transmission the SIU waits for acknowledgement from the receiving station. If the response is positive the SIU interrupts the CPU. If the response is negative the SIU retransmits the frame. The SIU can send the following responses to the primary station. RR (Receive Ready), RNR (Receive Not Ready). The FLEXIBLE mode requires the CPU to control the SIU for both transmitting and receiving. This slows response time but allows full SDLC and HDLC compatibility as well as variations. In FLEXIBLE mode the SIU can act as a primary station. The SIU will interrupt the CPU after completion of a transmission without waiting for a positive acknowledgement from the receiving station.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 22 of 32 1-888-824-4184 Frame Format Options The various frame formats available with the IA8044/IA8344 are the standard SDLC format, the no control field format, the no control field and no address fi eld format and the no FCS field format. The standard SDLC format consists of an opening flag, an 8 -bit address field, an 8 -bit control field, and n-byte information field, a 16 -bit frame check sequence field and a closing flag. The FCS is generated by the CCIT-CRC polynomial (X16 +X12 + X5 + 1). The address and control fields may not be extended. The address is contained in STAD and the control filed is contained in either RCB or TCB. This format is supported by both AUTO and FLEXIBLE modes. The no control field format is only supported by the FLEXIBLE mode. In this format TCB and RCB are not used and the information field starts immediately after the address field. The no control field and no address field format is only supported by the FLEXIBLE mode. In this format STAD, TCB and RCB are not used and the information field starts immediately after the opening flag. This option can only be used with the no control field option. The no FCS field format prevents an FCS from being generated during t ransmission or being checked during reception. This option may be used in conjunction with the other frame format options. This option will work with both FLEXIBLE and AUTO modes. In AUTO mode it could cause protocol violations. HDLC Restrictions The IA8044/IA8344 supports a subset of the HDLC protocol. The differences include the restriction by the IA8044/IA8344 of the serial data to be in 8 -bit increments. In contrast HDLC allows for any number of bits in the information field. HDLC provides an unl imited address field and an extended frame number sequencing. HDLC does not support loop configuration. SIU Details The SIU is composed of two functional blocks with each having several sub blocks. The two blocks are called the bit processor (BIP) and t he byte processor (BYP).

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 23 of 32 1-888-824-4184 Bit and Byte Processors BIP The BIP consists of the DPLL, NRZI encoder/decoder, serial/parallel shifter, zero insertion/deletion, shutoff logic and FCS generation/checking. The NRZI logic compares the current bit to the previo us bit to determine if the bit should be inverted. The serial shifter converts the outgoing byte data to bit data and incoming bit data to byte data. The zero insert/delete circuitry inserts and deletes zeros and also detects flags, go -aheads (GA) and ab orts. The pattern 1111110 is detected as an early go -ahead that can be turned into a flag in loop configurations. The shutoff detector is a three bit counter that is used to detect a sequence of eight zeros, which is the shutoff command in loop mode tran smissions. It is cleared whenever a one is detected. The FCS logic performs the generation and checking of the FCS value according to the polynomial described above. The FCS register is set to all 1’s prior to each calculation. If a CRC error is generated on a receive frame the SIU will not interrupt the CPU and the error will be cleared upon receiving an opening flag. BYP The BYP contains registers and controllers used to perform the manipulations required for SDLC communications. The BYP registers m ay be accessed by the CPU (see SFR section above). The BYP contains the SIU state machine which controls transmission and reception of frames.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 24 of 32 1-888-824-4184 Diagnostics A diagnostic mode is included with the IA8044/IA8344 to allow testing of the SIU. Diagnostics cleared writing data to P3.0 has the effect of writing a serial data stream to the SIU. P3.0 is the serial data and any write to port 3 will clock SCLK. The trans mit data may be monitored on P3.1 with any write to port 3 again clocking SCLK. In the test mode P3.0 and P3.1 pins are placed in the high impedance state. Diagnostic Signal Routing

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 25 of 32 1-888-824-4184 AC/DC Parameters Absolute Maximum Ratings: DC Characteristics Symbol Parameter Min Typ Max Unit VIL Input Low Voltage - - 0.8 V VIH Input High Voltage 2.0 - - V VOL Output Low Voltage (IOL= 4mA) - - 0.4 V VOH Output High Voltage (IOH= 4mA) 3.5 - - V RPU Pull-Up Resistance (Ports 1,2,3) - 50 - ΚΩ RPD Pull-Down Resistance (RST) - 50 - ΚΩ IIL Input Low Current (Ports 1, 2, 3) -100 1 µA IIL1 Input Low Current (all other inputs) -1 1 mA IIH Input High Current (RST) -1 - 100 µA IIH1 Input High Current (all other inputs) -1 1 µA IOZ Tri-state Leakage Current (Port 0,1,2,3) -10 10 µA ICC Power Supply Current: See Note 1 mA CIO Pin Capacitance - 4 - pF Notes: 1. Power dissipation character ization is in progress. Values will be provided upon completion of this process.

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 26 of 32 1-888-824-4184 A.C. Characteristics1 External Program Memory Characteristics Min Max Min Max TLHLL ALE Pulse Width ns TAVLL Address Valid to ALE Low ns TLLAX2 Address Hold After ALE Low ns TLLIV ALE Low to Valid Instr. In. ns TLLPL ALE Low to PSENn Low ns TPLPH PSENn Pulse Width TPLIV PSENn Low to Valid Instr. In TPXIX Input Instr. Hold After PSENn ns TPXIZ3 Input Instr. Float After PSENn ns TPXAV3 PSENn to Address Valid ns TAVIV Address to Valid Instr. In TAZPL Address Float to PSENn ns Unit Variable Clock 1/TCLCL = 3.5 MHz TO 12 MHzSymbol Parameter 12 MHz Osc Notes: 1. Actual values will provided for the External Program Memory Characteristi cs, External Data Memory Characteristics, and Serial Interface Characteristics tables (pp. 26 – 27) upon completion of device testing. Values from the original device data sheet may be used to characterize parameters in the interim. 2.TLLAX for access to program memory is different from TLLAX for data memory. 3. Interfacing RUPI-44 devices with float times up to 75ns is permissible. This limited bus contention will not cause any damage to Port 0 drivers

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 27 of 32 1-888-824-4184 External Data Memory Characteristics Min Max Min Max TRLRH RDn Pulse Width ns TWLWH WRn Pulse Width ns TLLAX Address Hold After ALE ns TRLDV RDn Low to Valid Data In. ns TRHDX Data Hold After RDn ns TRHDZ Data Float After RDn ns TLLDV ALE Low to Valid Data In ns TAVDV Address to Valid Data In. ns TLLWL ALE Low to RDn or WRn Low ns TAVWL Address to RDn or WRn Low ns TQVWX Data Valid to WRn Transistion TQVWH Data Setup Before WRn High ns TWHQX Data Held After WRn ns TRLAZ RDn Low to Address Float ns TWHLH RDn or WRn High to ALE High UnitSymbol Parameter 12 MHz Osc Variable Clock 1/TCLCL =

3.5 MHz TO 12 MHz

Serial Interface Characteristics Symbol Parameter Min Max Unit TDCY Data Clock ns TDCL Data Clock Low ns TDCH Data Clock High ns tTD Transmit Data Delay ns tDSS Data Setup Time ns tDHS Data Hold Time ns

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 28 of 32 1-888-824-4184 Waveforms Memory Access Program Memory Read Cycle ALE PSENn PORT_0 PORT_2 INSTR. IN A7-A0 INSTR. IN A7-A0 INSTR. ININSTR. IN ADDRESS OR SFR-P2 ADDRESS A15-A8 ADDRESS A15-A8ADDRESS A15-A8 TCY TLHLL TLLIV TLLPL TPLPH TAVLL TPLIV TAZPL TAVIV TLLAX TPXAV TPXIZ TPXIX Data Memory Read Cycle ALE PSENn RDn PORT_0 PORT_2 A7-A0 DATA IN ADDRESS A15-A8 OR SFR-P2ADDRESS A15-A8 OR SFR-P2 TWHLH TRLRHTLLWL TAVWL TLLDV TLLAX TRLDV TRLAZ TRHDZ TRHDX TAVDV

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 29 of 32 1-888-824-4184 Data Memory Write Cycle ALE PSENn WRn PORT_0 PORT_2 A7-A0 DATA OUTDATA OUT ADDRESS A15-A8 or SFR-P2ADDRESS A15-A8 or SFR-P2 TAVWL TLLAX TWLWH TWHLH TWHQX TLLWL TQVWX TQVWH Serial I/O Waveforms Synchronous Data Transmission SCLK DATA TDCL TTD TDCH TDCY Synchronous Data Reception SCLK DATA TDHSTDSS TDCHTDCL TDCY

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 30 of 32 1-888-824-4184 D E BOTTOM VIEW Packaging Information Package Dimensions for

44 Lead PLCC

(in Inches) A 0.180 A1 0.110 D1 0.653 D2 0.610 D3 0.500 E1 0.653 E2 0.610 E3 0.500 e 0.050 D 0.690 E 0.690 PIN 1 IDENTIFIER & ZONE 0.045*45o TOP VIEW .004 .02 MIN. R 0.035 SEATING PLANE e 0.026-0.032 A 0.013-0.021 D2 / E2 SIDE VIEW

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 31 of 32 1-888-824-4184 D L A B e SIDE VIEW (LENGTH) LEAD 1 IDENTIFIER LEAD COUNT DIRECTION E1 E TOP Package Dimensions for 40 Lead PDIP (600 mil.) Symbol Typical (in Inches) A 0.155 A1 0.010 B 0.018 B1 0.050 C 0.010 D 2.055 E 0.600 E1 0.545 e 0.100 eB 0.650 L 0.130 eB C SIDE VIEW (WIDTH)

IA8044/IA8344 Preliminary Data Sheet SDLC COMMUNICATIONS CONTROLLER As of Production Version 00 Copyright ã 2001 ENG210010112-00 www.innovasic.com innovASIC Customer Support: The End of Obsolescence ä Page 32 of 32 1-888-824-4184

  • Ordering Information Part Number Temperature Grade IA8044-PDW40I-00 Industrial IA8044-PLC44I-00 Industrial IA8344-PDW40I-00 Industrial IA8344-PLC44I-00 Industrial
  • Cross Reference to Original Part Numbers innovASIC Part Number IntelÒ Part Number IA8044-PLC44I q N8044AH q N8044AH-R0117 IA8044-PDW40I q P8044 q P8044AH q P8044AH-R0117 q TP8044AH q TP8044AH-R0117 IA8344-PLC44I q N8344AH q TN8344AH IA8344-PDW40I q P8344 q P8344AH q TP8344AH
  • Errata There is no errata for this device.