I500ERW MPD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Key Features: 5W Output Power 2:1 Input Range Miniature Case Single & Dual Outputs 1,500 VDC Isolation >1 MHour MTBF 32 Standard Models LOWEST COST!! I500ERW Ultra-Miniature 5W Single & Dual Output DC/DC Con vert ers Series Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range 12 VDC Input 9.0 12.0 18.0 VDC15 VDC Input 12.0 15.0 24.0 24 VDC Input 18.0 24.0 36.0 48 VDC input 36.0 48.0 72.0 Input Filter LC Filter Reverse Polarity Input Current 1.0 A Output Parameter Conditions Min. Typ. Max. Units Output Voltage Accuracy Positive ±1.0 ±3.0 %Negative ±3.0 ±5.0 Output Voltage Balance Dual Output , Balanced Loads ±1.0 % Line Regulation Vin = Min to Max ±0.2 ±0.5 % Load Regulation Iout = 10% to 100% ±0.5 ±2.0 Ripple (20 MHz) (Note 1) 30 50 mV P - P Noise (20 MHz) (Note 1) 100 150 mV P - P Output Power Protection 120 % Temperature Coeffi cient ±0.02 ±0.03 %/ºC Output Short Circuit Continuous (Autorecovery) General Parameter Conditions Min. Typ. Max. Units Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 MΩ Isolation Capacitance 100 kHz, 1V 150 pF Switching Frequency 300 kHz Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient -40 +25 +85 ºC Storage Temperature Range -55 +125 ºC Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Material Metal With Non-Conductive Base (UL94-V0) Weight 0.52 Oz (15g) Reliability Specifi cations Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 25ºC, Gnd Benign 1.0 MHours Absolute Maximum Ratings Parameter Conditions Min. Typ. Max. Units Input Voltage Surge (1 Sec) 12 VDC Input -0.7 20.0 VDC15 VDC Input -0.7 30.0 24 VDC Input -0.7 40.0 48 VDC Input -0.7 80.0 Lead Temperature 1.5 mm From Case For 10 Sec 300 ºC Internal Power Dissipation All Models 450 mW Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. MicroPower Direct
292 Page Street
Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com RoHS Compliant Electrical Specifi cations Specifi cations typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice.
Notes: All dimensions are typical in inches (mm) Tolerance x.xx = ±0.01 (±0.25) Pin 1 is marked by a “dot” on the top of the unit Model Number Input Output Effi ciency (%, Typ) Fuse Rating Slow-Blow (mA) Voltage (VDC) Current (mA) Voltage (VDC) Current (mA, Max) Current (mA, Min)Nominal Range Full-Load No-Load I501ERW 12 9.0 - 18.0 556 25 5.0 1,000 100 75 1,500 I502ERW 12 9.0 - 18.0 541 25 9.0 556 56 77 1,500 I503ERW 12 9.0 - 18.0 527 25 12.0 420 42 79 1,500 I504ERW 12 9.0 - 18.0 514 25 15.0 333 34 81 1,500 I505ERW 12 9.0 - 18.0 556 25 ±5.0 ±500 ±50 75 1,500 I506ERW 12 9.0 - 18.0 541 25 ±9.0 ±278 ±28 77 1,500 I507ERW 12 9.0 - 18.0 527 25 ±12.0 ±210 ±21 79 1,500 I508ERW 12 9.0 - 18.0 514 25 ±15.0 ±166 ±17 81 1,500 I511ERW 15 12.0 - 24.0 450 20 5.0 1,000 100 74 700 I512ERW 15 12.0 - 24.0 427 20 9.0 556 56 78 700 I513ERW 15 12.0 - 24.0 417 20 12.0 420 42 80 700 I514ERW 15 12.0 - 24.0 412 20 15.0 333 34 81 700 I515ERW 15 12.0 - 24.0 444 20 ±5.0 ±500 ±50 75 700 I516ERW 15 12.0 - 24.0 427 20 ±9.0 ±278 ±28 78 700 I517ERW 15 12.0 - 24.0 416 20 ±12.0 ±210 ±21 82 700 I518ERW 15 12.0 - 24.0 406 20 ±15.0 ±166 ±17 85 700 I521ERW 24 18.0 - 36.0 278 12.5 5.0 1,000 100 75 700 I522ERW 24 18.0 - 36.0 267 12.5 9.0 556 56 78 700 I523ERW 24 18.0 - 36.0 254 12.5 12.0 420 42 80 700 I524ERW 24 18.0 - 36.0 245 12.5 15.0 333 34 81 700 I525ERW 24 18.0 - 36.0 278 12.5 ±5.0 ±500 ±50 75 700 I526ERW 24 18.0 - 36.0 267 12.5 ±9.0 ±278 ±28 78 700 I527ERW 24 18.0 - 36.0 254 12.5 ±12.0 ±210 ±21 82 700 I528ERW 24 18.0 - 36.0 245 12.5 ±15.0 ±166 ±17 85 700 I531ERW 48 36.0 - 72.0 134 6.25 5.0 1,000 100 78 350 I532ERW 48 36.0 - 72.0 129 6.25 9.0 556 56 81 350 I533ERW 48 36.0 - 72.0 124 6.25 12.0 420 42 84 350 I534ERW 48 36.0 - 72.0 123 6.25 15.0 333 34 85 350 I535ERW 48 36.0 - 72.0 133 6.25 ±5.0 ±500 ±50 78 350 I536ERW 48 36.0 - 72.0 128 6.25 ±9.0 ±278 ±28 81 350 I537ERW 48 36.0 - 72.0 124 6.25 ±12.0 ±210 ±21 84 350 I538ERW 48 36.0 - 72.0 122 6.25 ±15.0 ±166 ±17 85 350 Pin Single Dual Pin Single Dual 1 +Vin +Vin 4 No Pin Common 2 -Vin -Vin 5 -Vout -Vout 3 +Vout +Vout Derating Curve Notes: 1. When measuring output ripple, it is recommended that an external ceramic capacitor (approx approx 1 µF to 10 µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. 2. These units should not be operated with a load under 10% of full load. Operation at no-load may cause damage to the unit. 3. These converters are specifi ed for operation without external components. However, in some applications the addition of input/ouput capacitors will enhance stability and reduce output ripple. Recommended capacitor values are: Vin Input Capacitor Vout Output Capacitor
12 VDC 100 µF 5 VDC 100 µF
15 VDC 100 µF 9 VDC 100 µF
24 VDC 10 µF 12 VDC 100 µF
48 VDC 10 µF 15 VDC 100 µF
For applications requiring very low output noise levels, a simple LC fi lter should be effective. 4. Dual output units may be connected to provide a 10V, 18V, 24V or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) out- puts and fl oat the output common. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Other input/output combinations are available (i.e. 24 VDC). Contact the factory for details at: sales@micropowerdirect.com Model Selection Guide Mechanical Dimensions Pin Connections MicroPower Direct www.micropowerdirect.com 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com