Flexible use thanks to its focus-free capability with 38° x 28° fi eld of view Unprecedented! 9 hours’ continuous use! Recovery of data from other measuring instruments (current, humidity, dew point, etc.) Practical: voice recordings, enhanceable integrated emissivity table, organization of folders by site Concentrated advantages!

Integration of your voice comments (details, measuring conditions, etc.) directly on the image. HIGH-PERFORMANCE HIGH-PERFORMANCE & USER-FRIENDLY& USER-FRIENDLY Slide-down protective cover: comfortable to use, no losses, no scratches. Laser pointer & focus- free with 28° x 38° field of view The image is automatically clear whatever the distance to the target. This comprehensive software off ers all the functions you need for reliable analysis of your measurement results

  • Cursors (automatic display of the temperature at the point selected)
  • Thermal profi le (automatic display of the Min/Max/Avg temperatures of the line)
  • A square or circle for analysing areas
  • Result tables quickly and automatically display all the information/tools for analysing the thermogram
  • Polygons and polylines to analyse certain areas of the thermogram in greater detail
  • Standard emissivity table which can be enhanced by the user THE C.A 1954 CAMERA: FAST & EFFECTIVE CAm Report®, the software for analysing the thermograms Perfect balance With the tripod insert under the camera or simply placed on a table, the camera does not move. Even simpler and more user-friendly thanks to: n its exceptional 9-hour battery life n an emissivity table which can be enhanced as required n the possibility of renaming the images and thermograms by site n recording and storage in memory of the configurations for each application (building, electrical cabinet, etc.)

& handling

APPLICATIONS

For electrical maintenance, before a fault occurs, thus avoiding the substantial cost of halting production or carrying out extra repairs, the C.A 1954 detects electrical equipment malfunctions, and particularly abnormal overheating:

  • faulty electrical contacts
  • unbalances
  • undersized components For mechanical maintenance, the C.A 1954 is ideal, off ering quick diagnostics through:
  • detection of anomalies or malfunctions on internal compo- nents to prevent engine overheating
  • verifi cation and inspection of mechanical parts and assem- blies to check for wear points, incorrect shaft alignment, lubrication problems, adjustment errors, etc. The PLUS: by linking the thermograms and currents, you can fi nd out the load level at the time of measurement, thus making it easier to identify the fault and assess how critical it is. Buildings & thermal inspections The Diacam2 C.A 1954 is a powerful tool for analysing buildings, whether new or old. This thermal camera can be used to detect faults and irregularities such as:
  • thermal bridges
  • insulation faults on the building envelope
  • draught-proofi ng (seepage)
  • presence of excessive humidity The C.A 1954 can also be used to search for water leaks and locate embedded or blocked pipes. The PLUS: when the isotherm is coupled with the dew-point value, you can detect areas at risk from mould. Energy effi ciency Infrared thermography can be used to detect thermal losses and thus deduce any pointlessly high energy consumption. These losses represent potential savings. The PLUS: recording of the ambient indoor or outdoor temperature via Bluetooth Wide 2.8-inch screen with automatic or manual brightness control For greater comfort and a longer battery life, the brightness of the display adapts to the ambient lighting conditions. Quick start-up The camera is operational after just a few seconds. Contextual help For simple, error-free use. Simultaneous recovery via Bluetooth of measurements performed using: n multimeters or clamp meters (current, etc.) n thermometers, thermo-hygrometers (ambient temperature, humidity, dew point, etc.) THE C.A 1954 CAMERA: FAST & EFFECTIVE Reports are generated automatically on the basis of several available templates. They can be exported in Word or PDF format. This makes them simpler to print and archive.

906211559 - Ed. 1 - 04/2018 - Non-contractual document. Specifications subject to modification due to technological developments. DETECTOR Dimensions 160 x 120 Type UFPA microbolometer, 8 ~14 μm Frequency 9 Hz Sensitivity (N.E.T.D) 80 mK @ 30 °C (0.08 °C @ 30 °C) TEMPERATURE MEASUREMENT Temperature range -20 °C to +250 °C Accuracy ±2 °C or ±2 % of reading IMAGING PERFORMANCE Thermal image -20 °C to +250 °C Field of view 38° x 28° IFOV (spatial resolution) 4.1 mrad Focus Fixed Minimum focal distance 30 cm Real image Yes (320 x 240 pixels) Display mode Thermal image, real image with automatic parallax compensation. Image merging available with PC software. ANALYTICAL FUNCTIONS Measuring tools 1 manual cursor + 1 automatic detection + Min Max Avg on adjustable area + temperature profile + isotherm Parameter settings Emissivity, environmental temperature, distance, relative humidity Voice comments Yes, by Bluetooth (earpiece supplied) Connectivity Environmental measurements: Clamp meters: F407, F607 Multimeters: MTX 3292, MTX 3293 Storage On 2 GB micro SD card (approx. 4,000 images) Exchangeable up to 32 GB Image format .png (thermal and real images saved simultaneously) Laser pointer yes IMAGE DISPLAY Settings Automatic or manual adjustment of the min max for the palette Freezing of image Animated or fixed image Display of the images Multi-palette Screen 2.8 inches POWER SUPPLY Type NiMH rechargeable batteries with low self-discharge Recharging method External (charger supplied) Battery life 9 hrs (typical) / 50 % brightness and Bluetooth deactivated ENVIRONMENTAL SPECIFICATIONS Operating temperature -15 °C to +50 °C (-4 °F to +122 °F) Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) Humidity 10 % to 95 % Compliance EN 61326-1: 2006 / EN 61010-1 Ed. 2 Resistance to falls 2 metres on all surfaces Shock resistance 25 G Vibration resistance 2 G PHYSICAL SPECIFICATIONS Weight / Dimensions 700 g with rechargeable batteries / 225 x 125 x 83 mm Ingress protection IP 54 Interfaces - USB link and Mass Storage function. The product is then recognized as a USB key to simplify image transfers - Bluetooth for connectivity with earpiece (voice comments) and Chauvin Arnoux ® measuring instruments (C.A 1821, C.A 1822, C.A 1823, C.A 1246, C.A 1227, F407, F607) and Metrix ® products (MTX 3292, MTX 3293) Mounting on tripod Yes, ¼’’ insert on the camera GENERAL INFORMATION Report generation software Supplied as standard with automatic report generation in .pdf or .docx (Word) format / Compatible with W7, W8, W10, 32 & 64 Bits Warranty 2 years TECHNICAL SPECIFICATIONS UNITED KINGDOM Chauvin Arnoux Ltd Unit 1 Nelson Ct, Flagship Sq, Shaw Cross Business Pk Dewsbury, West Y orkshire - WF12 7TH Tel: +44 1924 460 494 Fax: +44 1924 455 328 info@chauvin-arnoux.co.uk www.chauvin-arnoux.com Middle East Chauvin Arnoux Middle East P .O. BOX 60-154 1241 2020 JAL EL DIB - LEBANON Tel: +961 1 890 425 Fax: +961 1 890 424 camie@chauvin-arnoux.com www.chauvin-arnoux.com FRANCE Chauvin Arnoux 190, rue Championnet

75876 PARIS Cedex 18

Tel: +33 1 44 85 44 38 Fax: +33 1 46 27 95 59 export@chauvin-arnoux.fr www.chauvin-arnoux.com Standard state at delivery To order C.A 1954 thermal camera delivered in a site-proof case with 4 NiMH batteries and battery charger, 1 micro SD HC card, 1 USB cable, 1 Bluetooth earpiece, 1 specimen measurement report, CAm Report ® software on CD-Rom and user’s manual