HSG NOVARIS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 2

Technical content

Technical Information Sheet HSG N ovaris Pty Ltd 72 B rowns Road, Kingston, TAS. 7050 AUSTRALIA Tel: + 613 6229 7233 FAX: + 613 6229 9245 Email: sales@novaris.com.au URL: www.novaris.com.au HYBRID SURGE DI VERTER, SINGLE PHASE Product De scription No varis hybrid surge diverters are designed to protect electrical equipment against direct and induced transient overvoltages caused by lightning and temporary overvoltage on AC power supply circuits. Novaris surge diverters suit TN-C, TN-S, TN-C-S (MEN), TT and IT distribution systems. They provide all mode protection against transient overvoltages between phase and neutral, phase and earth and neutral and earth. Novaris surge diverters comply with all major lightning protection standards and are configured in accordance with IEC recommendations. Operation These s urge diverters feature all mode transient protection. Spark gap series with metal oxide varistor is connected between line and neutral.This component continuously monitored for integrity for both overcurrent and over temperature with status display via a built in LED indicator.The 8 /20µs rating for this component is 250kA. There is no follow on current. In accordance with IEC61643-11 recommendations (and IEC62305-4) all mode protection is achieved by the addition of fast acting gas discharge tube connected from neutral to earth. This GDT is rated at 100kA for an 8/20µs impulse (option). All Novaris power line surge arresters are housed in rugged and safe metal cases and are easily replaced should this be required. Plastic enclosures are not recommended. In addition to the LED alarm indicator on each module an external alarm is generated which allows for remote monitoring. This is provided by a clean contact either normally closed or normally open. An optional surge counter is available. This provides a count of surges diverted and has a sensitivity of 150A for an 8/20μs impulse. The HSGx-25-275 is designed for AC shunt diverter connection inside switchboards. Just like any other load it should be protected with an upstream over current protection device. A 63 A HRC fuse or 32A circuit breaker is recommended.

Technical Information Sheet HSG1-25-275 Novaris Pty Ltd

72 Browns

Road, Kingston, TAS. 7050 AUSTRALIA Tel: + 613 6229 7233 FAX: + 613 6229 9245 Email: sales@novaris.com.au URL: www.novaris.com.au Specifications Description: Po wer Line hybrid spark gap surge diverter Protection Mode: Line-Neutral Configuration: Voltage switching (Spark gap)series voltage limiting (MOV) Model: HSG1-25-275 Max.discharge current: Imax 250kA, 8/20 µs Nominal Voltage: Uo 22 0-240VAC / 50Hz Max.continuous voltage: Uc 480VAC / 50Hz Response tim e: tA <100ns Lightning impulse voltage sparkover : Up <1.1kV at 1.2/50 Charge: Q 12.5As Indicator: Internal LED External alarm: Clean SPDT contact Alarm isolation: 4kV Backup fuse: 63A HRC fuse Operating Temperature: -40 to +85 degC, 0 - 95% RH Terminal capacity-power: 16 mm2 Screw torque – p ower: 1.0 Nm Terminal capacity – alarm: 2.5 mm2 Screw torque – alarm: 0.5 Nm Dimensions: 200H x 60W x 70D Weight: 1.2kg Environmental Rating: IP20 Enclosure/Colour: Metal / Black Mounting: Panal mount / TS35 DIN rail Standards Compliance: IEC61643-1 Class I ,IEC61643-11 IEC1000-4-5 AS/NZS1768-2007 IEEE C62.41 category C UL1449 fourth edition IEC62305 <1.1kV at 1.2/50µs (480V variations upon requested) µs as IEC61643-1 Specific energy: W/R 625kJ/ /uni03A9 Let through voltage: <1.0kV at 3kA,8/20µs & 6kV,1.2/50µs as IEEE C62.41