HS1L Interlock Switches with Solenoid 3000N locking strength (strongest* in class)! Six contacts in a compact housing (same size as HS1E)! Suitable for large and heavy doors. Same actuators as HS1E (locking strength 3000N) can be used. Same dimensions and mounting hole layouts as HS1E. Size: 35 × 104 × 129mm Door open, closed, and locked status can be monitored for various applications. Energy efficient new solenoid unit. Manual unlock key and LED indicator are standard.• Manual unlock key allows for manual unlocking in the event of • power failure or maintenance. Indicator has an independent circuit, and can be used for vari-• ous applications. Two locking mechanisms to choose from—spring lock (un-• locked with energized solenoid) or solenoid lock (locked with energized solenoid). M3 terminal screws for wiring.• Wide operating temperature range (–20 to +55°C).• *As of October 2009, according to IDEC research of plastic interlock switches with solenoid. New energy saving design! Improved safety and usability! (Zinc Diecast) Manual Unlock Key L-shaped Actuator Angle Adjustable (vertical) Actuator Straight Actuator LED Indicator Solenoid Current Consumption HS1E Interlock Switch with Solenoid HS1L Interlock Switch with Solenoid 292 mA 200 mA Approx. 32% Less
HS1L Interlock Switches with Solenoid Actuator• Description Part Numbers Straight Actuator HS9Z-A1S L-shaped Actuator HS9Z-A2S Angle Adjustable (vertical) Actuator (for hinged door) HS9Z-A3S Package quantity: 1• Accessories• Description Part Numbers Key Wrench for TORX Screw (L-shaped) HS9Z-T1 Conduit Port Plug (Size: G1/2 only) HS9Z-P1 Package quantity: 1• Key Wrench for TORX Screw is supplied with the interlock switch. • Specifications Applicable Standard ISO14119 IEC60947-5-1 EN60947-5-1 (TÜV approval) GS-ET-19 (TÜV approval) UL508 (UL listed) CSA C22.2 No. 14 (c-UL listed) IEC60204-1/EN60204-1 (applicable standards for use) Operating Temperature −20 to +55°C (no freezing) Relative Humidity 45 to 85% (no condensation) Storage Temperature –40 to +80°C (no freezing) Pollution Degree 3 Overvoltage Category III Impulse Withstand Voltage 4.0kV (between LED, solenoid and ground: 1.5 kV) Contact Resistance 50mΩ maximum (initial value) Insulation Resistance Between live and dead metal parts: 100MΩ minimum (500V DC megger) Between terminals of different poles: 100MΩ minimum (500V DC megger) Electric Shock Protection Class II (IEC 61140) Degree of Protection IP67 (IEC 60529) Shock Resistance Damage limits: 1000m/s Vibration Resistance Operating extremes: 10 to 55Hz, amplitude 0.35mm Damage limits: 30Hz, amplitude 1.5mm Actuator Operating Speed 0.05 to 1.0 m/s Direct Opening Travel 11mm minimum Direct Opening Force 50N minimum Actuator Retention Force when Locked 3000N minimum (GS-ET-19) Operating Frequency 900 operations per hour Mechanical Durability 1,000,000 operations minimum (GS-ET-19) Electrical Durability 100,000 operations minimum (AC-15 3A/250V) 1,000,000 operations minimum (24V AC/DC, 100mA) (operating frequency 900 operations per hour) Conditional Short-circuit Current 100A (250V) (Use 250V/10A fast acting type fuse for short-circuit protection.) Weight (approx.) 450g (HS1L-DQ44) Ratings
- Contact Ratings Rated Insulation Voltage (Ui) 300V Rated Operating Current (Ith) 10A Rated Operating Voltage (Ue) 30V 125V 250V Rated Operating Current (Ie) AC Resistive Load (AC-12) 10A 10A 6A Inductive Load (AC-15) 10A 5A 3A DC Resistive Load (DC-12) 8A 2.2A 1.1A Inductive Load (DC-13) 4A 1.1A 0.6A Minimum applicable load (reference value): 3V AC/DC, 5mA • (Applicable range may vary with operating conditions and load types.) TÜV rating: AC-15 3A/250V, DC-13 4A/30V • UL, c-UL rating: A300 Pilot duty: AC 3A/250V Pilot duty: DC 4A/30V
- Solenoid Unit and LED Indicator Lock Mechanism Spring Lock Solenoid Lock Solenoid Rated Operating Voltage 24V DC (100% duty cycle) Rated Current 200 mA (initial value) Coil Resistance 120Ω (at 20°C) Pickup Voltage Rated voltage × 85% max. (at 20°C) Dropout Voltage Rated voltage × 10% max. (at 20°C) Maximum Continuous Applicable Voltage Rated voltage × 110% Maximum Continuous Applicable Time Continuous Insulation Class Class F LED Rated Operating Voltage 24V DC Rated Current 10 mA Light Source LED Illumination Color Green (G), Red (R) Parts and Functions Circuit Code Main Circuit Monitor Circuit R: 1NC+1NC 1NC/1NO, 2NC DQ: 1NC+1NC/ 1NO, 1NO 1NC+1NC DT: 1NC+1NC/ 1NC, 1NC 1NC+1NC HS1L-DQ44KMSRP-R Part Number Guide LED Rated Voltage 4: 24V DC LED Color G: Green R: Red Conduit Port Size Blank: 1/2 P: PG13.5 M: M20 Housing Color R: Red and Black Locking Strength MS: 3000N Manual Unlocking Key K: With key Solenoid Unit Voltage/ Lock Mechanism 4: 24V DC/Spring Lock 7Y: 24V DC/Solenoid Lock Terminal Block (M3) Actuator Entry Slots (Two) Conduit Port Contact Mechanism (M3)
HS1L Interlock Switches with Solenoid Types Lock Mechanism Circuit Code Contact Configuration Manual Unlocking Key Conduit Port Size LED Indicator Part Number Spring Lock R Main: 1NC+1NC Door monitor: 1NO/1NC Lock monitor: 2NC Monitor circuit: Monitor circuit: Monitor circuit: Monitor circuit: 2221 41 421211 33 34 51 52 61 62 Main circuit: With G1/2 Red HS1L-R44KMSR-R Green HS1L-R44KMSR-G PG13.5 Red HS1L-R44KMSRP-R Green HS1L-R44KMSRP-G M20 Red HS1L-R44KMSRM-R Green HS1L-R44KMSRM-G DQ Main: 1NC+1NC Door monitor: 1NO 1NC+1NC Lock monitor: 1NO Main circuit: Main circuit: Monitor circuit: Monitor circuit: 2221 41 421211 33 34 51 52 63 64 G1/2 Red HS1L-DQ44KMSR-R Green HS1L-DQ44KMSR-G PG13.5 Red HS1L-DQ44KMSRP-R Green HS1L-DQ44KMSRP-G M20 Red HS1L-DQ44KMSRM-R Green HS1L-DQ44KMSRM-G DT Main: 1NC+1NC Door monitor: 1NC 1NC+1NC Lock monitor: 1NC 2221 41 421211 51 52 3231 61 62 Main circuit: Main circuit: Monitor circuit: Monitor circuit: G1/2 Red HS1L-DT44KMSR-R Green HS1L-DT44KMSR-G PG13.5 Red HS1L-DT44KMSRP-R Green HS1L-DT44KMSRP-G M20 Red HS1L-DT44KMSRM-R Green HS1L-DT44KMSRM-G Solenoid Lock R (ʴ) (ʵ) (ʴ) (ʵ) LED Door Monitor (Actuator Inserted) Lock Monitor (Solenoid ON) Main: 1NC+1NC Door monitor: 1NO/1NC Lock monitor: 2NC Monitor circuit: Monitor circuit: Monitor circuit: Monitor circuit: 2221 41 421211 33 34 51 52 61 62 Main circuit: With G1/2 Red HS1L-R7Y4KMSR-R Green HS1L-R7Y4KMSR-G PG13.5 Red HS1L-R7Y4KMSRP-R Green HS1L-R7Y4KMSRP-G M20 Red HS1L-R7Y4KMSRM-R Green HS1L-R7Y4KMSRM-G DQ Main: 1NC+1NC Door monitor: 1NO 1NC+1NC Lock monitor: 1NO Main circuit: Main circuit: Monitor circuit: Monitor circuit: 2221 41 421211 33 34 51 52 63 64 G1/2 Red HS1L-DQ7Y4KMSR-R Green HS1L-DQ7Y4KMSR-G PG13.5 Red HS1L-DQ7Y4KMSRP-R Green HS1L-DQ7Y4KMSRP-G M20 Red HS1L-DQ7Y4KMSRM-R Green HS1L-DQ7Y4KMSRM-G DT Main: 1NC+1NC Door monitor: 1NC 1NC+1NC Lock monitor: 1NC 2221 41 421211 51 52 3231 61 62 Main circuit: Main circuit: Monitor circuit: Monitor circuit: G1/2 Red HS1L-DT7Y4KMSR-R Green HS1L-DT7Y4KMSR-G PG13.5 Red HS1L-DT7Y4KMSRP-R Green HS1L-DT7Y4KMSRP-G M20 Red HS1L-DT7Y4KMSRM-R Green HS1L-DT7Y4KMSRM-G The contact configuration shows the status when the actuator is inserted and the switch is locked.• Actuators are not supplied with the interlock switch and must be ordered separately.• 11 12 21 22 41 42 51 52 A1A2X2 X1 31/33 32/34 Terminal Numbers 11-42: Main circuit 21: Main circuit or monitor circuit (door monitor) 22: Monitor circuit (door monitor) 31/33: Monitor circuit (door monitor) 32/34: Monitor circuit (door monitor) 51: Monitor circuit (lock monitor) 52: Main circuit or monitor circuit (lock monitor) 61/63: Monitor circuit (lock monitor) 62/64: Monitor circuit (lock monitor) A1: Solenoid (–) A2: Solenoid (+) X1: LED (–) X2: LED (+) * There is no wiring between 22-51 with circuit code R. (ʴ) (ʵ) (ʴ) (ʵ) LED Door Monitor (Actuator Inserted) Lock Monitor (Solenoid OFF)
HS1L Interlock Switches with Solenoid Dimensions and Mounting Hole Layouts (mm) Actuator Mounting Reference Position• As shown in the figure on the right, the mounting reference position of the actuator, when inserted in the interlock switch, is where the actuator stop placed on the actuator lightly touches the interlock switch. Note: After mounting the actuator, remove the actuator cover and stop film. Interlock switch when using • L-shaped actuator (HS9Z-A2S) Note: Plug the unused actuator entry slot with the slot plug supplied with the interlock switch. * Install the interlock switch using four mounting screws when using the actuator entry slot vertical to the mounting panel, and three mounting screws when using the actuator entry slot horizontal to the mounting panel. Note: The actuator cover and the actuator stop film are supplied with the actuator and used when adjusting the actuator position. Remove them after the actuator position has been determined. ∗ When using the actuator entry slot vertical to the mounting panel. ∗33.5 23.5 26 4-M5 Screws Interlock Switch Mounting Hole Layout 44.7 3.7 35 1.5 104 12.3 19.2 45.4 7.5 49.5 129 121 1025.5 4 23.5 26 55.8 70.3 Actuator Entry Slot (Vertical to mounting panel) Actuator Entry Slot (Horizontal to mounting panel) HS9Z-A1S Actuator Slot Plug (supplied with the switch) (Note) Actuator mounting reference position ʢ3.5±0.5ʣ Actuator Cover Rubber Bushing ʢ8ʣ (7.0±0.5) Actuator mounting reference position Straight Actuator (HS9Z-A1S)• L-shaped Actuator (HS9Z-A2S)• 18.5 0.8 ø5.1 ø15.0 5.1 When mounted (8) 17.6 49.39 Actuator Cover (gray) (Note) Actuator Mounting Hole Layout 2-M5 Screws 11.5 11.5 5.1 0.8 42.6 (45.1) 20.5 ø5.1 ø15 17.6 When mounted (8) Actuator Cover (gray) (Note) Actuator Mounting Hole Layout 2-M5 Screws (65.8) 17.5 ±0.5 11.5 (51.3) 21 ±0.5 HS9Z-A2S Actuator Actuator Cover Rubber Bushing Actuator mounting reference position Actuator mounting reference position Interlock switch when using • straight actuator (HS9Z-A1S) 17.6 R3.2 33 max. (21) 20° 2-M6 Screws Door HingeAngle Adjustment Screw (M3 hexagon sockethead bolt) Actuator Stop Film (supplied with the actuator) 11.5 11.5 5.1 0.8 42.6 (45.1) 20.5 ø5.1 ø15 17.6 When mounted (8) Actuator Cover (gray) (Note) Actuator Mounting Hole Layout 2-M5 Screws Angle Adjustable (vertical) Actuator • (HS9Z-A3S) HS9Z-A1S Actuator Acuator Cover Interlock Switch Door Stop Door Stop Acuator Cover Interlock Switch Interlock Switch HS9Z-A2S Actuator HS9Z-A3S Actuator Actuator Stop Film
HS1L Interlock Switches with Solenoid Circuit Diagrams and Operating Characteristics Spring Lock Type• Interlock Switch Status Status 1 Status 2 Status 3 Status 4 Manual Unlock Door Closed• Machine ready to • operate Solenoid de-energized• Door Closed• Machine cannot be • operated Solenoid energized• Door Open• Machine cannot be • operated Solenoid energized• Door Open• Machine cannot be • operated Solenoid de-energized• Door Closed• Machine cannot be • operated Solenoid de-energized• Door Status UNLOCK Unlock position Circuit Diagram (HS1L-DQ4) (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked) Contact Configuration HS1L-DQ4 63 64 3433 2221 11 12 4241 (+) (–) Door Monitor (Actuator inserted) Lock Monitor (Solenoid OFF) Monitor Circuit: Monitor Circuit: Main Circuit: Main Circuit: 5251 (+) (–) LED Main Circuit 11–42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Main Circuit 21–52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Door Monitor Circuit (Door Open) 33–34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) Lock Monitor Circuit (unlocked) 63-64 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed) Solenoid Power A1-A2 OFF (de-energized) ON (energized) ON (energized) OFF (de-energized) OFF (de-energized) Solenoid Lock Type• Interlock Switch Status Status 1 Status 2 Status 3 Status 4 Manual Unlock Door Closed• Machine ready to • operate Solenoid energized• Door Closed• Machine cannot be • operated Solenoid de-energized• Door Open• Machine cannot be • operated Solenoid de-energized• Door Open• Machine cannot be • operated Solenoid energized• Door Closed• Machine cannot be • operated Solenoid de-energized • to energized Door Status UNLOCK Unlock position Circuit Diagram (HS1L-DQ4) (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 (–)(+) A2 A1 34 63 64 5251 2221 11 12 4241 Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked) Contact Configuration HS1L-DQ7Y 63 64 3433 2221 11 12 4241 5251 (+) (–) Lock Monitor (Solenoid ON) Monitor Circuit: Monitor Circuit: Main Circuit: Main Circuit: (+) (–) Door Monitor (Actuator inserted)LED Main Circuit 11–42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Main Circuit 21–52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open) Door Monitor Circuit (Door Open) 33–34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open) Lock Monitor Circuit (unlocked) 63-64 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed) Solenoid Power A1-A2 ON (energized) OFF (de-energized) OFF (de-energized) ON (energized) (Note 2) OFF to ON (Note 1) (Note 2) Note 1: Do not attempt manual unlocking while the solenoid is energized. Note 2: Do not energize the solenoid for a long period of time while the door is open or manually unlocked. Operation Characteristics (reference)• The operation characteristics show the contact status when the • actuator enters into the center of the entry slot. The circuit No. 12-41 and 22-51 are interconnected. Use circuits • 11-42 and 21-52 for safety circuits (In HS1L-R type, circuit 12-41 is interconnected.) 30.010.0 4.2 (Locked position) 0 (Actuator insertion position) 7.0 Door Monitor Circuit (Door closed,NC) Lock Monitor Circuit (Locked, NC) Door Monitor Circuit (Door open, NO) Main Circuit Lock Monitor Circuit (Unlocked, NO) Contacts ON (closed) Contacts OFF (open) (Approx. travel in mm)
HS1L Interlock Switches with Solenoid Safety Precautions! In order to avoid electric shock or fire, turn power off before • installation, removal, wiring, maintenance, or inspection of the interlock switch. If relays are used in the circuit between the interlock switch • and the load, consider the danger, and use safety relays, since welded or sticking contacts of standard relays may in- validate the functions of the interlock switch. Perform a risk assessment and establish a safety circuit which satisfies the requirement of the safety category. Do not place a PLC in the circuit between the interlock switch • and the load. Safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the interlock switch, otherwise • the switch may fail or an accident may occur. Do not install the actuator in a location where someone may • come in contact with it as injury may occur. Install the actuator where it does not touch anyone when the • door is opened/closed as injury may occur. The solenoid lock type is locked when energized, and un-• locked when de-energized. When energization is interrupted due to wire disconnection or other failures, the interlock switch may be unlocked causing possible danger to the operators. Solenoid lock type must not be used in applications where locking is required for safety. Perform a risk assessment and determine whether a solenoid lock type is appropriate. In order to prevent the interlock switch and actuator from be-• ing removed without authorization, it is recommended to in- stall an one-way screw or a screw that needs a special tool for removal. Welding or rivets are also recommended. Instructions Regardless of door types, do not use the interlock switch as • a door stop. Install a mechanical door stop at the end of the door to protect the interlock switch from excessive force. Make sure that no force is applied on the actuator, otherwise • the actuator may not unlock properly. Do not apply excessive shock to the interlock switch when • opening or closing the door. A shock to the interlock switch ex- ceeding 1,000m/s2 may cause damage to the interlock switch. If the operating atmosphere is contaminated, use a protective • cover to prevent the entry of foreign objects into the interlock switch through the actuator entry slots. Entry of foreign ob- jects into the interlock switch may affect the mechanism of the interlock switch and cause it to fail. Plug the unused actuator entry slot using the slot plug sup-• plied with the interlock switch. Do not store the interlock switches in a dusty, humid, or or-• ganic-gas atmosphere, or where the switches are exposed to direct sunlight. Use proprietary actuators only. The interlock switch may be • damaged if other actuators are used, . The actuator retention force is 3000N. Do not apply a load • higher than the rated value. When a higher load is expected, provide an additional system consisting of another interlock switch without lock (such as the HS5D interlock switch) or a sensor to detect door opening and stop the machine. Regardless of the door, do not use the interlock switch as a • door lock. Install a separate lock using a latch or other device. While the solenoid is energized, the interlock switch tempera-• ture rises approximately 40°C above the ambient tempera- ture (to approximately 95°C while the ambient temperature is 55°C). To prevent burns, do not touch. If cables might come into contact with the interlock switch, use heat-resistant ca- bles. The interlock switch solenoid has polarity. Be sure of the cor-• rect polarity when wiring. Minimum Radius of Hinged Door When using the interlock switch for a hinged door, refer to the minimum radius of doors as shown below. For doors with a small minimum radius, use actuators with adjustable angle (HS9Z-A3S). Note: The following values apply when the actuator does not interfere with the interlock switch when opening and closing the door. Because de- viation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. When using HS9Z-A2S Actuator When the door hinge is on the extension line of the interlock • switch surface: 270 mm 450 mm Door Hinge Minimu m Radiu s Minimu m Radius Door Hinge When the door hinge is on the extension line of the actuator • mounting surface: 510 mm Door Hinge Minimu m RadiusMinimumRadius 840 mm Door Hinge When using HS9Z-A3S Actuator When the door hinge is on the extension line of the interlock • switch surface: 50mm When the door hinge is on the extension line of the actuator • mounting surface: 80mm 80 mm50 mm Door Hinge MinimumRadius MinimumRadius Door Hinge Actuator Angle Adjustment Using the angle adjustment screw, the actuator angle can • be adjusted (refer to the dimensional drawing on page 4). Adjustable angle: 0 to 20° The larger the adjusted angle of the actuator, the smaller the • applicable radius of the door opening. After installing the actu- ator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the in- terlock switch. After adjusting the actuator angle, apply Loctite to the adjust-• ment screw so that the screw will not move.
HS1L Interlock Switches with Solenoid Instructions Mounting Examples Install the interlock switch and actuator referring to the figures below. Application on Slinding Doors Door Interlock Switch HS9Z-A1S Latch Door Stop Application on Hinged Doors Door Interlock Switch HS9Z-A2S HS9Z-A1S Latch For Manual Unlocking Spring lock type The HS1L allows manual unlocking of the actuator to pre-check proper door movement before wiring or turning power on, as well as for emergency use such as in the case of a power fail- ure. Solenoid lock type The solenoid lock type interlock switch normally does not need to be manually unlocked. However, only when the interlock switch would not release the actuator even though the solenoid is de-energized, the interlock switch can be unlocked manually. Unlock the interlock switch manually only when the solenoid is de-energized. Do not unlock the interlock switch manually when the solenoid is energized. Using manual unlock key When locking or unlocking the interlock switch manually, turn • the key fully using the manual unlock key supplied with the interlock switch. Using the interlock switch with the key not fully turned (less • than 90°) may cause damage to the interlock switch or op- eration failure. When manually unlocked, the interlock switch will keep the main circuit disconnected and the door unlocked. Main circuit and lock monitor circuit remain open. Do not leave the manual unlock key attached to the interlock • switch during operation. This is dangerous and does not satis- fy safety standard requirements, because the interlock switch can always be unlocked while the machine is in operation. Manual Unlocking PositionNormal Position UNLOCK UNLOCK Manual unlocking key (supplied with the switch) Unlocking from the back of interlock switch• Insert the tip of a small screwdriver into the oblong hole on the back of the interlock switch, and tilt toward the center of the switch until the actuator is unlocked. Note: Provide a hole on the mounting panel for unlocking from the back. When making a hole in the panel, take water- proof characteristics into consideration. 2.6 Safety Precautions Before manually unlocking the interlock switch, make sure that the machine has come to a complete stop. Manual unlocking during operation may unlock the interlock switch before the ma- chine stops, and the function of interlock switch with solenoid is lost. On the solenoid lock type, manual unlocking is provided for the situation where the switch cannot be unlocked even though the solenoid has turned off. Do not attempt manual unlocking while the solenoid is energized. Cover Opening and Closing Precautions When opening the cover before wiring, make sure to open • only the cover shown the following figure. Removing unneces- sary screws may cause a failure of the interlock switch. Use HS9Z-T1 key wrench for TORX screw when removing • and installing the cover. Make sure that no foreign objects such as dust, water, or oil • enter the interlock switch when wiring. HS9Z-T1 L-shaped wrench (supplied with the switch) Lid T20 Applicable Crimping Terminal 4.2 min. ø3.2 min. 6.4 max. Insulation Tube Wire Approx. 4 mm Applicable Crimping Terminal Use an insulation tube on the crimping terminal.• When using stranded wires, make sure that loose wires do • not cause a short circuit. Also, do not solder the terminal to prevent loose wires. Applicable Crimping Terminal Applicable Wire N0.5-3 / FN0.5 (JST) 0.2 to 0.5mm2 N1.25-MS3 (JST) 0.25 to 1.65mm2 V1.25-YS3A (JST) 0.25 to 1.65mm2 Applicable Wire Size 0.5 to 1.5mm• 2 Applicable Cable Glands Use IP67 cable glands.
HS1L Interlock Switches with Solenoid Instructions 9 mm max. G1/2, PG13.5, M20 30 mm max. When Using Flexible Conduit (Example) Flexible conduit example: VF-03 (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G1/2 – RLC-103 (Nihon Flex) PG13.5 – RBC-103PG13.5 (Nihon Flex) M20 – RLC-103EC20 (Nihon Flex) When Using Multi-core Cables (Example) Flexible conduit example: VF-03 (Nihon Flex) Conduit Port Size Plastic Cable Gland Metal Cable Gland G1/2 SCS-10 (Seiwa Electric) ALS-16 (Nihon Flex) PG13.5 ST13.5 (K-MECS) ABS-PG13.5 (Nihon Flex) M20 ST-M20X1.5 (K-MECS) (Note) ALS-EC20 (Nihon Flex) Different cable glands are used depending on the cable sheath exter-• nal diameter. When purchasing a cable gland, confirm that the cable gland is applicable to the external diameter of the cable sheath. Note: When using the ST-M20X1.5 cable gland, use with a gasket (GPM20, K-MECS). Conduit Port Opening Make an opening for wiring by breaking one of the conduit-• port knockouts on the interlock switch housing using a screwdriver. Before opening the conduit port, remove the cable gland • locking ring inside the interlock switch. When breaking the conduit port, take care not to damage the • contact block or other parts inside the interlock switch. Cracks or burrs on the conduit entry may affect the water • resistance of the interlock switch. If a different conduit port is used, cover the unused opening • with an optional plug (part number: HS9Z-P1). Recommended Tightening Torque HS1L interlock switch: 3.2 to 3.8 N·m (four M5 screws) (Note)• Lid: 0.9 to 1.1 N·m (M4 screws)• Terminal: 0.6 to 0.8 N·m (M3 screws)• Cable gland: 2.7 to 3.3 N·m• Actuators• HS9Z-A1S/A2S: 2.7 to 3.3 N·m (two M5 screws) (Note) HS9Z-A3S: 4.5 to 5.5 N·m (two M6 screws) (Note) Note: The above recommended tightening torque of the mounting screws are the values when using hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not become loose after mounting. Wire Length Inside the Interlock Switch• Screw Terminal No. Through Conduit Port ➀ ➁ Wire Length L1 (mm) 11 95 ± 2 45 ± 2 21 85 ± 2 35 ± 2 22 60 ± 2 70 ± 2 31/33 75 ± 2 35 ± 2 32/34 50 ± 2 60 ± 2 42 65 ± 2 95 ± 2 51 45 ± 2 70 ± 2 52 55 ± 2 85 ± 2 61/63 35 ± 2 60 ± 2 62/64 45 ± 2 75 ± 2 A1 50 ± 2 45 ± 2 A2 60 ± 2 40 ± 2 X1 70 ± 2 35 ± 2 X2 80 ± 2 35 ± 2 Wire Stripping Length: L2 (mm) 7 ± 1 11 12 21 22 41 42 51 52 A1A2X2 X1 31/33 32/34 Interlock Switch Connector L1L2 Note: HS1L-R Do not remove the wire between terminals 12-41, because these terminals are interconnected for safety circuit input. Use terminals 11-42 for safety circuit inputs. (GS-ET-19) HS1L-DQ and HS1L-DT Do not remove the wires between terminals 12-41 and 22-51, be- cause these terminals are interconnected for safety circuit inputs. Use terminals 11-42 and 21-52 for safety circuit inputs. (GS-ET-19) Plug (HS9Z-P1)1.27 ø26 G1/2 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan E-mail: marketing@idec.co.jp Specifications and other descriptions in this catalog are subject to change without notice. Cat. No. EP1286-0-1 Updated October 2010 PDF only IDEC ELECTRONICS LIMITED Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: sales@uk.idec.com IDEC ELEKTROTECHNIK GmbH Tel: +49-40-25 30 54 - 0, Fax: +49-40-25 30 54 - 24 E-mail: service@idec.de IDEC (SHANGHAI) CORPORATION Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 E-mail: idec@cn.idec.com IDEC (BEIJING) CORPORATION Tel: +86-10-6581-6131, Fax: +86-10-6581-5119 IDEC (SHENZHEN) CORPORATION Tel: +86-755-8356-2977, Fax: +86-755-8356-2944 IDEC IZUMI (H.K.) CO., LTD. Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: info@hk.idec.com IDEC TAIWAN CORPORATION Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@tw.idec.com IDEC IZUMI ASIA PTE. LTD. Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com www.IDEC.com IDEC CORPORATION (USA) Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com IDEC CANADA LIMITED Tel: +1-905-890-8561, Toll Free: (888) 317-4332 Fax: +1-905-890-8562 E-mail: sales@ca.idec.com IDEC AUSTRALIA PTY. LTD. Tel: +61-3-9763-3244, Toll Free: 1800-68-4332 Fax: +61-3-9763-3255 E-mail: sales@au.idec.com