Great care is taken during the preparation of data, but Mclennan cannot guarantee accuracy so it should be used for reference only Power Supply HRP600A48 HRP600A48_19/09 1 of 2 ■ Universal AC input / Full range ■ Built-in active PFC function, PF > 0.94 ■ High efficiency - up to 89% ■ Withstand 300 VAC surge input for 5 seconds ■ Protections: short circuit / overload / over-voltage / over - temperature ■ Built-in constant current limiting circuit ■ Built-in cooling fan ON/OFF control ■ Built-in DC OK signal ■ Built-in remote sense function ■ All using 105°C long life electrolytic capacitors OUTPUT DC VOLTAGE 48V RATED CURRENT 13A RATED POWER 624W RIPPLE & NOISE (max.) Note.2 240mVp-p VOLTAGE ADJ. RANGE 40.8 ~ 55.2V VOLTAGE TOLERANCE Note.3 ± 1.0% LINE REGULATION ± 0.2% LOAD REGULATION ± 0.5% SETUP , RISE TIME 1800ms, 50ms / 230VAC 3600ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) 16ms / 230VAC 16ms/115VAC at full load INPUT VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.94/230VAC PF>0.99/115VAC at full load EFFICIENCY (Typ.) 89% AC CURRENT (Typ.) 7.6A / 115VAC 3.6A/230VAC INRUSH CURRENT (Typ.) 35A / 115VAC 70A/230VAC LEAKAGE CURRENT <1.2mA / 240VAC PROTECTION OVERLOAD 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down FUNCTION DC OK SIGNAL PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V FAN CONTROL (Typ.) Load 35± 15% or RTH2 ≥ 50°C Fan on ENVIRONMENT WORKING TEMP . -40 ~ +70°C (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP ., HUMIDITY -40 ~ +85°C, 10 ~ 95% RH non-condensing TEMP . COEFFICIENT ± 0.03%/ (0 ~ 50°C) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY & EMC (Note 4) SAFETY STANDARDS UL60950-1, TUV EN60950-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVA ISOLATION RESISTANCE I/P-O/P , I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020 HRP600A48 Specification
Great care is taken during the preparation of data, but Mclennan cannot guarantee accuracy so it should be used for reference only OTHERS MTBF 140.6K hrs min. MIL -HDBK-217F (25°C) DIMENSIONS 218*105*63.5mm (L *W*H) PACKING 1.5Kg;8pcs/13Kg/1.34CUFT NOTES 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. T olerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm·360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EM/ testing of component power supplies. " 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. The ambient temeprature derating of 3.5% / 1000m with fanless models and of 5% / 1000m with fan models for operating altitude higher than 2000m (6500ft). HRP600A48 Specification cont' HRP600A48 Mechanical specification Mechanical Specification Case No. 977A Unit:m m AC Input Terminal Pin No. Assi gnmen t DC Output Terminal Pin No. Assign ment Pin No. Pin No. 1 1~3 2 4~6 Assig nment Assignmen t AC/N +V AC/L -V Pin No. Assi gnment DC-OK GND Mating Housing Termina l or equivalent or equiv alent Connector Pin No. Assi gnment (CN1 00) : HRS DF11-4DP-2DS or equ ivalent HRS DF11-4DS HRS DF11-SC FG Derating Curve Output Derating VS Input Voltage INPUT VOLTAGE (V) 60Hz 85 100 125 135 155 264 100 )%(DAOL 501 18max . 2.9 O/P AMBIENT TEMPERATURE ( )°C )%( DAOL -40 0 10 20 30 40 50 60 70 100 125 (HORIZONTAL) DC OK PWM fosc : 70KHz EMI INRUS H ACTI VE FILTER CURR ENT LIMITING RECTI FIERS PFC I/P FG PWMPFC CIRCUI T DETECTI ON POWER SWI TCHI NG FILTER RECTI FIERS +V CONTRO LCONTROL O.V.P. O.T.P. Air flo w directio n 001NC DEL 1RVS ).JDAoV( 5.36 I/P 4-M4 L=6 12max. 2.8 5.36 57.02 218 32.8152.4 12 34 Block Diagram 8-M4 L=4 (Both Sides) 32.8 3.83 5.21 152.4 HRP600A48_19/09 2 of 3 HRP600A48 Derating curve Mechanical Specification Case No. 977A Unit:m m AC Input Terminal Pin No. Assi gnmen t DC Output Terminal Pin No. Assign ment Pin No. Pin No. 1 1~3 2 4~6 Assig nment Assignmen t AC/N +V AC/L -V Pin No. Assi gnment DC-OK GND Mating Housing Termina l or equivalent or equiv alent Connector Pin No. Assi gnment (CN1 00) : HRS DF11-4DP-2DS or equ ivalent HRS DF11-4DS HRS DF11-SC FG Derating Curve Output Derating VS Input Voltage INPUT VOLTAGE (V) 60Hz 85 100 125 135 155 264 100 )%(DAOL 501 18max . 2.9 O/P AMBIENT TEMPERATURE ( )°C )%( DAOL -40 0 10 20 30 40 50 60 70 100 125 (HORIZONTAL) DC OK PWM fosc : 70KHz EMI INRUS H ACTI VE FILTER CURR ENT LIMITING RECTI FIERS PFC I/P FG PWMPFC CIRCUI T DETECTI ON POWER SWI TCHI NG FILTER RECTI FIERS +V CONTRO LCONTROL O.V.P. O.T.P. Air flo w directio n 001NC DEL 1RVS ).JDAoV( 5.36 I/P 4-M4 L=6 12max. 2.8 5.36 57.02 218 32.8152.4 12 34 Block Diagram 8-M4 L=4 (Both Sides) 32.8 3.83 5.21 152.4 HRP600A48 Output derating vs. input voltage Mechanical Specification Case No. 977A Unit:m m AC Input Terminal Pin No. Assi gnmen t DC Output Terminal Pin No. Assign ment Pin No. Pin No. 1 1~3 2 4~6 Assig nment Assignmen t AC/N +V AC/L -V Pin No. Assi gnment DC-OK GND Mating Housing Termina l or equivalent or equiv alent Connector Pin No. Assi gnment (CN1 00) : HRS DF11-4DP-2DS or equ ivalent HRS DF11-4DS HRS DF11-**SC FG Derating Curve Output Derating VS Input Voltage INPUT VOLTAGE (V) 60Hz 85 100 125 135 155 264 100 )%(DAOL 501 18max . 2.9 O/P AMBIENT TEMPERATURE ( )°C )%( DAOL -40 0 10 20 30 40 50 60 70 100 125 (HORIZONTAL) DC OK PWM fosc : 70KHz EMI INRUS H ACTI VE FILTER CURR ENT LIMITING RECTI FIERS PFC I/P FG PWMPFC CIRCUI T DETECTI ON POWER SWI TCHI NG FILTER RECTI FIERS +V CONTRO LCONTROL O.V.P. O.T.P. Air flo w directio n 001NC DEL 1RVS ).JDAoV( 5.36 I/P 4-M4 L=6 12max. 2.8 5.36 57.02 218 32.8152.4 12 34 Block Diagram 8-M4 L=4 (Both Sides) 32.8 3.83 5.21 152.4