HRL5.5-12P-T2-RA BB-BATTERY | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Nominal Capacity 5.0Ah @ 10 hour rate F.V.(1.75V/cell) Terminals 27m 1.5 A oo o o Charge 0 C~40 C(32 F~104 F) oo o o Discharge -20 C~50 C(-4 F~122 F) oo o o Storage. -20 C~40 C(-4 F~104 F) Internal Resistance Length 90±1.5 Width 70±1.5 Container Height 102±1.5 Total Height OUTER DIMENSIONS TERMINAL TYPE 12 V Max. Charge Current Container Material DIMENSION(mm/inch) 1800g(3.97lbs.) VRLA Rechargeable Battery TechnologyMeasures InnovationValues 106±2.0 APPLICATION FEATURES SPECIFICATIONS Approx. Weight Max. Discharge Current 75 A (5 sec.) (Fully Charged ) Operating Temperature Range (3.54±0.06) (2.76±0.06) (4.02±0.06) (4.17±0.08) All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. HR5.5-12 UPS Power Packs Emergency Lights Fishing Lights T1 (Faston Tab 187) T2 is optional Toy-Cars Terminal T1 Terminal T2 4.75(0.19) 6.35(0.25) 6.35(0.25) 0.8(0.03) 102 1.5(4.02 0.06) 106 2(4.17 0.08) (V/cell) F.V. Discharge Time 5 Min 10 Min 15 Min 20 Min Unit: Wo o Constant power discharge characteristics at 25 C/77 F
30 Min 40 Min 50 Min 60 Min 120 Min
225.5 269.5 288.8 297.0 302.5 305.3 154.0 171.9 180.8 184.3 186.8 188.4 111.5 121.3 126.8 129.6 131.0 132.0 95.2 100.8 104.5 106.2 107.1 107.8 72.4 75.4 77.0 78.0 78.5 79.0 55.0 57.1 58.4 59.2 59.5 59.8 46.0 47.4 48.4 49.0 49.4 49.6 40.5 41.4 42.1 42.5 42.8 42.9 22.3 22.7 23.1 23.2 23.3 23.3 Unit: W (V/cell) F.V. Discharge Time 5 Min 10 Min 15 Min 20 Min Unit: Ao o Constant current discharge characteristics at 25 C/77 F 20.13 24.50 26.25 27.00 27.50 27.75 13.51 15.08 15.86 16.17 16.39 16.53 9.65 10.49 10.97 11.21 11.33 11.42 8.16 8.64 8.96 9.11 9.19 9.25 6.14 6.39 6.53 6.61 6.65 6.69 4.63 4.80 4.91 4.98 5.00 5.03 3.85 3.97 4.05 4.10 4.13 4.15 3.38 3.45 3.51 3.54 3.57 3.58 1.86 1.89 1.93 1.93 1.94 1.94 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V IEC 61056-1 JIS C 8702-1 GB/T 19639.1 Maintenance free(no water topping-up required). No free acid(Non-spillable battery). Low self-discharge rate, lower than 3% capacity loss per month. Can be used in any orientation(excluding used inverted). The battery is designed for high rate usage. Absorbent Glass Mat technology for efficient gas recombination. The power density at 5 min~15min discharging rate is 30% higher than BP series. Standard: ABS( UL 94-HB) HR5.5-12 HR5.5-12FROptional: Flame Retardant ABS(UL 94-V0)