EVP44-12 BB-BATTERY | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

Nominal Capacity 44Ah @ 20 hour rate F.V.(1.75V/cell) Terminals 13.2 A oo o o Charge 0 C~40 C(32 F~104 F) oo o o Discharge -20 C~50 C(-4 F~122 F) oo o o Storage. -20 C~40 C(-4 F~104 F) ABS(UL94-HB, UL94-V0 is optional) Internal Resistance Length 197±1.5 Width 165±1.5 Container Height 171±1.5 Total Height OUTER DIMENSIONS TERMINAL TYPE 12 V Max. Charge Current Container Material DIMENSION(mm/inch) 15.5Kg(34.181lbs.) VRLA Rechargeable Battery (EVP44-12FR)EVP44-12 TechnologyMeasures InnovationValues 171±1.5 APPLICATION FEATURES SPECIFICATIONS Approx. Weight Max. Discharge Current 600 A (5 sec.) (Fully Charged ) Operating Temperature Range (7.76±0.06) (6.50±0.06) (6.73±0.06) (6.73±0.06) All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. Maintenance free(no water topping-up required) No free acid(Non-spillable battery) Low self-discharge rate,lower than 3% capacity loss per month Can be used in any orientation(excluding used inverted) The battery is designed for high power & high cyclic usage UPS Wheelchairs Lawn Mowers Electronic Medical Equipment Golf-Carts Equipment ISO 9001 ISO14001 UL CE IEC61056 JIS C 8702 GB/T 19639 Terminal Hardware Initial Torque: B2/I1 (4.0Nm±5%),I2(5.5Nm±5%) B2 (Fitting M5 bolt & nut) , I1 and I2 are optional 171 1.5(6.73 0.06) Terminal B2 [M5 BOLT & NUT] 7.5(0.30) 17.0(0.67) 5.5(0.22) Terminal I1 [M5 BOLT & NUT] M5x0.8 2.0(0.08) Terminal I2 [M6 BOLT] M6x1.0 2.0(0.08) (V/cell) F.V. Discharge Time 5 Min 10 Min 15 Min 30 Min 1 Hr 3 Hr 5 Hr 10 Hr 20 Hr Unit: Wo o Constant power discharge characteristics at 25 C/77 F 1890 2188 2325 2430 2510 1339 1451 1509 1542 1570 963 1018 1048 1076 1095 605 628 642 652 660 345 355 363 367 370 140.0 143.5 144.6 146.0 146.5 88.5 90.0 90.7 91.1 91.4 49.3 50.3 50.6 50.7 50.7 25.8 26.4 26.5 26.6 26.6 (V/cell) F.V. Discharge Time 5 Min 10 Min 15 Min 30 Min 1 Hr 3 Hr 5 Hr 10 Hr 20 Hr Unit: Ao o Constant current discharge characteristics at 25 C/77 F 175.00 206.42 219.34 229.25 236.79 121.73 133.12 138.44 141.47 144.04 91.26 96.73 99.55 101.82 103.64 53.54 55.58 56.81 57.70 58.41 28.99 29.83 30.50 30.84 31.09 11.67 11.96 12.05 12.17 12.21 7.38 7.50 7.56 7.59 7.17 4.11 4.19 4.22 4.23 4.23 2.15 2.20 2.21 2.22 2.22 1.80V 1.75V 1.70V 1.65V 1.60V 1.80V 1.75V 1.70V 1.65V 1.60V