Nominal Capacity 73Ah @ 10 hour rate F.V.(1.75V/cell) Terminals 21.9 A oo o o Charge 0 C~40 C(32 F~104 F) oo o o Discharge -20 C~50 C(-4 F~122 F) oo o o Storage. -20 C~40 C(-4 F~104 F) Internal Resistance Length 350±2.0 Width 166±2.0 Container Height 174±2.0 Total Height OUTER DIMENSIONS TERMINAL TYPE 12 V Max. Charge Current Container Material DIMENSION(mm/inch) 24.75Kg(54.57lbs.) VRLA Rechargeable Battery HR75-12 TechnologyMeasures InnovationValues 174±2.0 APPLICATION FEATURES SPECIFICATIONS Approx. Weight Max. Discharge Current 650 A (5 sec.) (Fully Charged ) Operating Temperature Range (13.78±0.08) (6.54±0.08) (6.85±0.08) (6.85±0.08) All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. UPS Golf-Carts Wheelchairs B5 (Fitting M6 bolt & nut) I2 is optional Terminal Hardware Initial Torque: B5/ I2(5.5Nm±5%) 174 2.0(6.86 0.08) Terminal B5 [M6 BOLT & NUT] 7.0(0.28) 7.0(0.28) 19.0(0.75) Terminal I2 [M6 BOLT] M6x1.0 2.0(0.08) (V/cell) F.V. Discharge Time 15 Min 20 Min Unit: Wo o Constant power discharge characteristics at 25 C/77 F

30 Min 40 Min 50 Min 60 Min 120 Min

1520.7 1647.3 1728.8 1766.3 1786.0 1799.9 1297.8 1373.0 1425.1 1447.5 1460.4 1470.0 986.3 1027.5 1049.6 1063.2 1070.9 1076.3 750.0 778.5 796.5 806.3 811.5 815.7 625.6 646.9 660.0 667.5 672.2 676.7 551.3 563.4 573.7 579.4 585.0 585.0 303.8 310.1 315.0 316.8 317.7 318.6 Unit: W (V/cell) F.V. Discharge Time 15 Min 20 Min Unit: Ao o Constant current discharge characteristics at 25 C/77 F 131.55 142.50 149.55 152.79 154.50 155.70 111.30 117.75 122.22 124.14 125.25 126.07 83.59 87.08 88.95 90.10 90.75 91.21 63.08 65.48 66.99 67.81 68.25 68.60 52.35 54.14 55.23 55.86 56.25 56.63 45.94 46.95 47.81 48.29 48.75 48.75 25.31 25.84 26.25 26.40 26.48 26.55 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V IEC 61056-1 JIS C 8702-1 GB/T 19639.1 Maintenance free(no water topping-up required). No free acid(Non-spillable battery). Low self-discharge rate, lower than 3% capacity loss per month. Can be used in any orientation(excluding used inverted). The battery is designed for high rate usage. Absorbent Glass Mat technology for efficient gas recombination. The power density at 5 min~15min discharging rate is 30% higher than BP series.

10 Min

184.20 205.65 216.30 220.40 223.50 225.00 2099.9 2344.4 2465.8 2512.6 2547.9 2565.0

5 Min

3019.5 3674.6 3936.9 4050.0 4125.0 4162.4 274.50 334.05 357.90 368.18 375.00 378.40 Standard: ABS( UL 94-HB) HR75-12 HR75-12FROptional: Flame Retardant ABS(UL 94-V0)