The HHP650 AC-DC power supply provides upto 780 W (1000 W peak) of output power in a robust mechanical fan-cooled package for industrial applications. The unit comprises of a main output with voltages from 12-48 VDC and a 5 VDC standby supply which can be utilitsed with the signals and control features of the unit to provide detection of loss of output and remote on/off control.
- 85 V - 305 VAC Input
- MIL-STD-810F Shock & Vibration
- -40 °C to +70 °C Operation
- SEMI F47 Compliant
- 6 kV Surge Rating - IEEEStdC62.41
- UL508, ANSI/ISA 12.12.01 Class I, Div II
- Conformal Coating
- 3 Year Warranty Dimensions: HHP650: www.xppower.com1 Models & Ratings Output Voltage Output Current V1 Standby Supply Output Power V1 Model NumberNom Peak(1) Nom Peak(1) <180 V >180 V <180 V >180 V <180 V >180 V <180 V >180 V 12 V 50.0 A -- 5 V / 0.2 A 607 W -- HHP650PS12 15 V 40.0 A - - 5 V / 0.2 A 607 W - - HHP650PS15 VO+ Logic Connector J3 A A AA A A CL VO- 1.95 (49.50) 6.31 (160.30) 2.50 (63.54) 9.99 (253.80) Standard Terminal Block M4 Screw 6 Pins 9.5mm Center N L 0.92 (23.30) 4.20 (106.77) 3.04 (77.30) 0.47 (11.90) 2.50 63.500 VR B LED A Mounting hole 8 places M3 X 0.5 0.15(3.8) Max. Penetration DETAIL B PIN 1 PIN 2 PIN 11 PIN 12 Standard Terminal Block M3.5 Screw 3 Pins 9.5mm Center Mechanical Details Notes 1. Peak Power available for 10 seconds maximum with a 35% duty cycle. The average power in a period should be equal or less than the nominal power. HHP650 Series AC-DC Power Supplies 600/780 Watts
Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table Initial Set Accuracy ±1 (V1) , ±5 (V Standby) % 50% load, 115/230 VAC Output Voltage Adjustment ±10 % V1 only. See mechanical details. Minimum Load 0A Start Up Delay 500 ms Hold Up Time 20 ms 90 VAC Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % Load Regulation ±1 (V1) , ±5 (V Standby) % 0-100% load. Transient Response - V1 4% Recovery within 1% in less than 500 µs for a 50-75%-50% load change Ripple & Noise 1 % pk-pk V1: 20 MHz bandwidth Overvoltage Protection 115 145 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 110 175 % Output 1 only, auto reset. See fig 1. Short Circuit Protection Trip & restart (hiccup mode) Overtemperature Protection 100 °C Auto reset. Input & output stage protection Temperature Coefficient 0.05 %/˚C Overtemperature Protection °C Protects unit from overtemperature. Auto reset. Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage - Operating 85 305 VAC Derate output power 10% < 90 VAC. Input Frequency 47 50/60 63 Hz Agency approval, 47-63 Hz Power Factor >0.9 EN61000-3-2 class A compliant EN61000-3-2 class C for loads ≥10% Input Current - Full Load 6.5/3.2 A 115/230 VAC Inrush Current 60 A 305 VAC cold start, 25 ºC Earth Leakage Current 1.5 mA 305 VAC/60 Hz Input Protection T16 A / 250 V internal in-line fuse HHP Series www.xppower.com 2 AC-DC Power Supplies Output Overload Characteristics Figure 1 Output Power (W) Output Voltage (%) T rip & Restart 100 200 400 600 800 1000 1200 1400
www.xppower.com AC-DC Power Supplies General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 85 % See fig. 2 & 3 Isolation: Input to Output Input to Ground Output to Ground
3000 VAC
2000 VAC
500 VAC
Power Density 7.4 W/in3 >180 VAC Mean Time Between Failure 177 kHrs MIL-HDBK-217F, +25 °C GB Weight 2.8 (1.7) lb (kg) Efficiency Vs Load Figure 2 HHP650PS12 Figure 3 HHP650PS48
HHP Series AC-DC Power Supplies www.xppower.com 4 Signals & Controls Characteristic Notes & Conditions Remote Sense Compensates for 0.5 V total voltage drop DC OK Volt free relay contacts NO/NC (see fig.4) Remote On/Off (Inhibit/Enable) Uncommited isolated optocoupler diode, powered diode inhibits both V1 & V2 (fan supply) (see fig.5) Current Share When 2 to 5 units (with the same output voltage) are used in parallel to increase output current, the current share pins 7/8 of one unit should be connected to pins 7/8 of the other unit(s). This will force the current to share between the outputs. Similarly pins 9/11 of each unit should also be connected as a ground reference. Units share current within 10% of each other at full load. Standby Supply Isolated 5 V/0.2 A supply, always present when AC supplied. DC OK Figure 4 Figure 5 <0.8 V): >4.5 V): INHIBIT HI INHIBIT LOW Inhibit Hi Pin 6 POWER SUPPLY 100 R 800 R 2-5 mA Chassis J3 Logic Connector Signal High: Power Supply OFF Low or Floating: Power Supply ON Signal High: Power Supply ON Low or Floating: Power Supply OFF Inhibit Lo Pin 5
5 V Standby
Chassis J3 Logic Connector Inhibit Lo Pin 5 Remote On/Off (Inhibit) Chassis J3 Logic Connector POWER SUPPLY Pin 4 Pin 10 Pin 2 NC COM NO
HHP Series AC-DC Power Supplies www.xppower.com 24-Feb-14 Mechanical Details VO+ Logic Connector J3 A A AA A A CL VO- 1.95 (49.50) 6.31 (160.30) 2.50 (63.54) 9.99 (253.80) Standard Terminal Block M4 Screw 6 Pins 9.5mm Center N L 0.92 (23.30) 4.20 (106.77) 3.04 (77.30) 0.47 (11.90) 2.50 63.500 VR B LED A Mounting hole 8 places M3 X 0.5 0.15(3.8) Max. Penetration DETAIL B PIN 1 PIN 2 PIN 11 PIN 12 Standard Terminal Block M3.5 Screw 3 Pins 9.5mm Center 1. Dimensions shown in inches (mm). 2. Weight: 2.8 lb (1.27 kg). 3. J1 Mating Plug: JST part no. PHR-2, contact: JST part no. SPH-002T-P0.5S; J2 Mating Plug: JST part no. PHDR-10VS, contact: 26-22AWG JST part no. SPHD-001T-P0.5 Notes J3 Logic Connector (JST S12B-PHDSS) Pin Function 1 5 V Standby Return
2 NO (Relay)
4 N.C (Relay) 5 - Inhibit 6 +Inhibit
7 Current Share
8 Current Share
10 COM (Relay)
Safety Agency Safety Standard Notes & Conditions CB Report IEC60950-1:2005 + A1:2009 Information Technology UL UL60950-1 (2011), CSA 22.2 No.60950-1 Information Technology UL508, CSA 22.2 No. 107.1-01 Industrial Control Equipment ANSI/ISA 12.12.01-2000 Hazardous Locations TUV EN60950-1 A12:2011 Information Technology CE LVD & RoHS Equipment Protection Class Class I See safety agency conditions of acceptibility for details