Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com

FEATURES

  • 10 mbar to 5 bar, absolute, gage or differential pressure
  • Digital I2C-bus and analog output
  • Precision ASIC signal conditioning
  • Calibrated and temperature compensated
  • SMT and DIP housings
  • RoHS compliant ELECTRICAL CONNECTIONSPECIFICATIONS Maximum ratings Supply voltage VS max. 6.50 VDC Output current Sink 1 mA Source 1 mA Lead specifications Average preheating temperature gradient 2.5 K/s Soak time ca. 3 min Time above 217°C 50 s Time above 230°C 40 s Time above 250°C 15 s Peak temperature 260°C Cooling temperature gradient -3.5 K/s Temperature ranges5 Compensated 0 ... +85 °C Operating -20 ... +85 °C Storage -40 ... +125 °C MEDIA COMPATIBILITY To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like. +Vs Vout SDA SCL GND

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com Specification notes: 1. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters of the sensing element. 2. Burst pressure is the maximum pressure which may be applied without causing damage to the sensing element or leaks to the housing. 3. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. 4. Total accuracy is the combined error from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. 5. Extended temperature ranges on request. Please contact First Sensor. 6. Max. delay time between pressure change at the pressure die and signal change at the output. and reponse time are available on request. Please contact First Sensor for further information. 8. Sensors with lower current consumption are available on request. Please contact First Sensor for further information. Part no. Operating pressure Proof pressure1 Burst pressure2 Other pressure ranges are available on request. Please contact First Sensor. PRESSURE SENSOR CHARACTERISTICS (TA=25 °C, RH=50 %)

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com PERFORMANCE CHARACTERISTICS (VS=5.0 VDC, TA=25 °C, RH=50 %, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS) Characteristics Min. Typ. Max. Units ANALOG PERFORMANCE CHARACTERISTIC Zero pressure offset 0.48 0.50 0.52 VFull scale span (FSS)3 4.00 Full scale output 4.48 4.50 4.52 DIGITAL PERFORMANCE CHARACTERISTIC Zero pressure offset 3146 3277 3408 countsFull scale span (FSS)3 26214 Full scale output 29359 29490 29621 Characteristics Min. Typ. Max. Units ANALOG PERFORMANCE CHARACTERISTIC Zero pressure offset 2.48 2.50 2.52 VFull scale span (FSS)3 4.00 Output at max. specified pressure 4.48 4.50 4.52 at min. specified pressure 0.48 0.50 0.52 DIGITAL PERFORMANCE CHARACTERISTIC Zero pressure offset 16252 16384 16515 countsFull scale span (FSS)3 26214 Output at max. specified pressure 29359 29490 29621 at min. specified pressure 3146 3277 3408 Characteristics Min. Typ. Max. Units Total accuracy (0...85°C)4 all barometric devices ±1.0 %FSS all other devices ±0.5 Response delay6, 7 0.5 ms A/D resolution7 12 bitD/A resolution 11 Current consumption8 5 mA All HDI...P5 devices (VS = 5.0) Characteristics Min. Typ. Max. Units ANALOGUE PERFORMANCE CHARACTERISTIC Output at min. specified pressure 0.46 0.50 0.54 VFull scale span (FSS)3 4.00 Full scale output 4.46 4.50 4.54 DIGITAL PERFORMANCE CHARACTERISTIC Output at min. specified pressure 3015 3277 3539 countsFull scale span (FSS)3 26214 Full scale output 29228 29490 29752

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com PERFORMANCE CHARACTERISTICS (VS=3.0 VDC, TA=25 °C, RH=50 %, analog output signal is ratiometric to VS, digital output signal is not ratiometric to VS) Characteristics Min. Typ. Max. Units ANALOG PERFORMANCE CHARACTERISTIC Zero pressure offset 0.24 0.25 0.26 VFull scale span (FSS)3 2.00 Full scale output 2.24 2.25 2.26 DIGITAL PERFORMANCE CHARACTERISTIC Zero pressure offset 2621 2731 2840 countsFull scale span (FSS)3 21845 Full scale output 24466 24575 24684 Characteristics Min. Typ. Max. Units ANALOG PERFORMANCE CHARACTERISTIC Zero pressure offset 1.24 1.25 1.26 VFull scale span (FSS)3 2.00 Output at max. specified pressure 2.24 2.25 2.26 at min. specified pressure 0.24 0.25 0.26 DIGITAL PERFORMANCE CHARACTERISTIC Zero pressure offset 13545 13653 13762 countsFull scale span (FSS)3 21845 Output at max. specified pressure 24466 24575 24684 at min. specified pressure 2621 2731 2840 All HDI...P3 devices (VS = 3.0) Characteristics Min. Typ. Max. Units Total accuracy (0...85°C)4 all barometric devices ±1.0 %FSS all other devices ±0.5 Response delay6, 7 0.5 ms A/D resolution7 12 bitD/A resolution 11 Current consumption8 3 mA Characteristics Min. Typ. Max. Units ANALOGUE PERFORMANCE CHARACTERISTIC Output at min. specified pressure 0.23 0.25 0.27 VFull scale span (FSS)3 2.00 Full scale output 2.23 2.25 2.27 DIGITAL PERFORMANCE CHARACTERISTIC Output at min. specified pressure 2512 2731 2949 countsFull scale span (FSS)3 21845 Full scale output 24357 24575 24794

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com I²C BUS Introduction The HDI is capable to generate a digital output signal. The device runs a cyclic program, which will store a corrected pressure value with 12 bit resolution about every 250 µs within the output registers of the internal ASIC. In order to use the sensor for digital signal readout, it should be connected to a bidirectional I²C-bus. According to the I²C-bus specification, the bus is controlled by a master device, which generates the clock signal, controls the bus access and generates START and STOP conditions. The HDI is designed to work as a slave, hence it will only respond to requests from a master device. Digital I²C interface The HDI complies with the following protocol (Fig. 1): Bus not busy: During idle periods both data line (SDA) and clock line (SCL) remain HIGH. START condition (S): HIGH to LOW transition of SDA line while clock (SCL) is HIGH is interpreted as START condition. START conditions are always generated by the master. Each initial request for a pressure value has to begin with a START condition. STOP condition (P): LOW to HIGH transition of SDA line while clock (SCL) is HIGH determines STOP condition. STOP conditions are always generated by the master. More than one request for the current pressure value can be transmitted without generation of intermediate STOP condition. DATA valid (D): State of data line represents valid data when, after START condition, data line is stable for duration of HIGH period of clock signal. Data on line must be changed during LOW period of clock signal. There is one clock pulse per bit of data. Acknowledge (A): Data is transferred in pieces of 8 bits (1 byte) on serial bus, MSB first. After each byte receiving device – whether master or slave – is obliged to pull data line LOW as acknowledge for reception of data. Master must generate an extra clock pulse for this purpose. When acknowledge is missed, slave transmitter becomes inactive. It is on master either to send last command again or to generate STOP condition in that case. Slave address: The I²C-bus master-slave concept requires a unique address for each device. The HDI has a preconfigured slave address (1111000xb). By factory programming it is possible to define a secondary slave address additional to the general one. According to I²C specification 127 different addresses are available. The sensor will then listen to both slave addresses. After generating a START condition the master sends the address byte containing a 7 bit address followed by a data direction bit (R/W). A "0" indicates a transmission from master to slave (WRITE), a "1" indicates a data request (READ). DATA operation: The sensor starts to send 2 data bytes containing the current pressure value as a 15 bit information placed in the output registers. Fig. 1: I²C bus protocol SDA SCL START condition Data valid Data allowed to change STOP conditionR/W Read out of first pressure value Read out of n pressure values (optional) S Data Byte 1 A Data Byte 2Slave Address A A PData Byte 1 generated by master generated by slave S = START condition A = Acknowledge P = STOP condition Data Byte 1 = High Byte (MSB first) Data Byte 2 = Low Byte (LSB last)

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com I²C Interface Parameters Parameter Symbol Min. Typ. Max. Unit Input high level 90 100 % of VsInput low level 0 10 Output low level 10 Pull-up resistor 500 W Load capacitance @ SDA CSDA 400 pFInput capacitance @ SDA/SCL CI2C_IN 10 SCL clock frequency FSCL 100* 400 kHz Bus free time between STOP and START condition tBUF 1.3 µs Hold time (repeated) START condition, to first clock pulse tHD.STA 0.8 LOW period of SCL tLOW 1.3 HIGH period of SCL tHIGH 0.6 Setup time repeated START condition tSU.STA 1 Data hold time tHD.DAT 0 Data setup time tSU.DAT 0.2 Rise time of both SDA and SCL tR 0.3 Fall time of both SDA and SCL tF 0.3 Setup time for STOP condition tSU.STO 0.6 Note: First Sensor recommends communication speeds of at least 100 kHz (max. 400 kHz). Please contact us for further information. * recommended Fig. 2: Timing characteristics tHD;STA tSU;DAT tHD;DAT tSU;STA tR tF SCL SDA tHIGH tLOW tSU;STO tBUF tHD;STA SDA SCL

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com dimensions in mm dimensions in mm PHYSICAL DIMENSIONS first angle projection first angle projection 2,30 2,68 4,10 11,90 3,41 2,54 5,08 15,70 0,25 3,40 6,23 9,28 1,90 0,63 0,46 10,939,64 3,35 5,73 19,50 18,75R0,40 8,83 7,60 2,30 2,68 4,10 11,90 3,41 2,54 5,08 15,70 14,32 0,25 3,40 6,23 0,86 0,63 0,46 9,898,60 2,31 4,69 19,50 18,75R0,40 7,79 7,60

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com dimensions in mm dimensions in mm PHYSICAL DIMENSIONS (cont.) first angle projection first angle projection 11,90 3,41 2,54 5,08 13,01 2,69 3,03 15,70 0,25 5,73 0,63 R0,40 8,83 0,46 15,70 ±0,50 6,83 ±0,50 R0,80 2,69 3,03 2,12 ±0,50 7,79 ±0,50 A high pressure port 11,90 3,41 2,54 5,08 15,70 14,32 0,25 7,79 2,69 3,03 0,63 4,69 15,79 0,46 R0,40 0,96

Amplified pressure sensors E / 11650 / G www.first-sensor.com www.sensortechnics.com Pin Connection 1 +Vs 2 +Vout

3 GND

4 SDA

5 I / C*

6 SCL

  • Internal connection. Do not connect for any reason ELECTRICAL CONNECTION (cont.) (absolute) (gage) (differential) First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. Pin marking 3 2 1 4 5 6 Pin marking 1 2 3 6 5 4 4 5 6 3 2 1 High pressure port Pin marking

ORDERING INFORMATION

Series Pressure range Pressure mode Calibration Housing Porting Grade Voltage Options HDI 0611 600...1100 mbar A* Absolute B* Bidirectional F* DIP, 2 ports same side

8 Straight P Prime 5 5 V

0811 800...1100 mbar D Differential U Unidirectional 3 3 V M010 10 mbar G Gage R** Barometric E* SMD, 2 ports same side M020 20 mbar M050 50 mbar Z DIP, 1 port axial M100 100 mbar M200 200 mbar Y SMD, 1 port axial M500 500 mbar B001 1 bar (B001A) 1 bara B002 2 bar B005 5 bar * only from 1 bar * only up to 1 bar ** for pressure ranges 0611, 0811 * standard for differential devices, "D" ** standard for absolute and gage devices, "A" and "G" Example: HDI M050 G U Z 8 P 5 Note: Devices highlighted in grey are preferred stock items