Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2021.06 H2F Rev7 info@zemic.nl Page 1/4 www.zemiceurope.com Short Description
- Nickel plated alloy steel IP67 spoke type load cell
- High accuracy
- Suitable for hanging, hopper and other electronic weighing devices Available Models Capacity Accuracy Full Article Description 1t C1/C2/C3 H2F-C1/C2/C3-1t-3T6 2t C1/C2/C3 H2F-C1/C2/C3-2t-3T6 3t C1/C2/C3 H2F-C1/C2/C3-3t-3T6 5t C1/C2 H2F-C1/C2-5t-4T6 10t C1 H2F-C1-10t-4T6 10t C2 H2F-C2-10t-5T6 15t C1 H2F-C1-15t-5T6 20t C1 H2F-C1-20t-5T6 30t C1 H2F-C1-30t-5T6 50t C1 H2F-C1-50t-5T6
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2021.06 H2F Rev7 info@zemic.nl Page 2/4 www.zemiceurope.com Technical Specifications H2F Accuracy Class C1 C2 C3 Output Sensitivity ( = FS ) mV/V 2.0 ± 0.01 Maximum Capacity ( Emax ) t 1, 2, 3, 5, 10, 15, 20, 30, 50 1, 2, 3, 5, 10 1, 2, 3 Max. Number of Load Cell Intervals nLC 1000 2000 3000 Ratio of min. LC Verification Interval Y = Emax / vmin 3000 5000 7500 Combined Error %FS ≤± 0.050 ≤± 0.030 ≤± 0.020 Creep Error (30 minutes) %FS ≤± 0.038 ≤± 0.023 ≤± 0.016 Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.047 ≤± 0.029 ≤± 0.011 Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.028 ≤± 0.017 ≤± 0.019 Zero Balance %FS ≤± 1.0 Safe Overload %FS 150 Ultimate Overload %FS 300 Excitation, Recommended Voltage V 5 ~ 12 Excitation, Maximum Voltage V 18 Input Resistance Ω 770 ± 30 Output Resistance Ω 700 ± 7 Insulation Resistance (50V) MΩ ≥5000 Compensated Temperature °C -10 ~ + 40 Operating Temperature °C -35 ~ + 65 Storage Temperature °C -40 ~ + 70 Load Cell Weight kg 1t - 5t: ~2.2 10t: 6.2 15t: 7.5 20t: 11.2 30t: 16.5 50t: 21.5 Element Material Alloy Steel Ingress Protection (acc. to EN 60529) IP67 Recommended Torque on Fixation Bolts Nm M8: 25 M10: 50 M12: 75 Wiring Features: Cable type: Shielded, 6 conductor cable , conductor AWG 24 Cable diameter: Ø 5.0mm Cable length: 1t – 3t: 3m, 5t – 10t: 4m, 15t – 50t: 5m Cable jacket: PVC Shield not connected to element 6-Wire Connection Diagram Input(+) Sense (+) Output(-) Sense (-) Input (-) Output(+) Red Brown White Black Yellow Blue
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2021.06 H2F Rev7 info@zemic.nl Page 3/4 www.zemiceurope.com Dimensions in mm Front View Top View Dimension Capacity D D1 D2 H H1 H2 H3 L R 1t 115 22 86 43 12 8.4 5 8 4.2 2t 120 26 90 45 12 8.4 5 8 4.2 3t 128 20 100 46 8 10.4 5 7 5.2 5t 128 20 100 46 8 10.4 5 7 5.2 10t 160 40 120 63 15 10.4 10 10 5.2 15t 194 42 154 68 20 12.4 10 12 6.2 20t 220 44 170 73 22 12.4 10 12 6.2 30t 230 48 188 78 25 12.4 10 12 6.2 50t 264 52 214 90 30 12.4 10 12 6.2
Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever. Zemic Europe B.V. T: +31 76 50 39480 Nr. 2021.06 H2F Rev7 info@zemic.nl Page 4/4 www.zemiceurope.com Available Accessories HM-2-401-1t-50t
- Nickel Plated Alloy steel
- Easy Installation
- Lift-off Protection
- Built-in Horizontal Movement Control