GT5Y Miniature Electronic Timers 1086 Four Selectable Time Ranges Delayed Output 4PDT/3A or DPDT/5A Three operation modes: ON Delay, Interval ON, and Cycle Repeat error: ±0.2% maximum Miniature size LED indicators for output and power Complies with safety standards. UL/c-UL listed. EN compliant. Time Ranges Code Scale Time Range Indication Time Range 1S 0 to 10 × 0.1 S 0.1 sec to 1 sec 10S 0 to 10 × 1 S 0.2 sec to 10 sec 1M 0 to 10 × 0.1 M 1.2 sec to 1 min 10M 0 to 10 × 1 M 12 sec to 10 min 3S 0 to 3 × 1 S 0.1 sec to 3 sec 30S 0 to 3 × 10 S 0.5 sec to 30 sec 3M 0 to 3 × 1 M 3 sec to 3 min 30M 0 to 3 × 10 M 30 sec to 30 min 6S 0 to 6 × 1 S 0.1 sec to 6 sec 60S 0 to 6 × 10 S 1 sec to 60 sec 6M 0 to 6 × 1 M 6 sec to 6 min 60M 0 to 6 × 10 M 1 min to 60 min Contact Ratings Type No. GT5Y-4 GT5Y-2 Contact Configuration 4PDT DPDT Rated Load Resistive Load 220V AC, 3A 30V DC, 3A 220V AC, 5A 30V DC, 5A Inductive Load cosø=0.3 L/R=7ms 220V AC, 0.8A 30V DC, 1.5A 220V AC, 2A 30V DC, 2.5A Maximum Switching Voltage 250V AC/125V DC 250V AC/125V DC Maximum Switching Current 3A 5A (Note) Maximum Switching Frequency 1800 operations/hour 1800 operations/hour Allowable Contact Power Resistive Load AC: 660VA DC: 90W AC: 1100VA DC: 150W Inductive Load cosø= 0.3 L/R=7ms AC: 176VA DC: 45W AC: 440VA DC: 75W Minimum Applicable Load 5V DC, 10mA (reference value) 5V DC, 20mA (reference value) 24V DC, 5mA (reference value) 24V DC, 10mA (reference value) External Protection Element Fuse 250V 3A Fuse 250V 5A Life Electrical 200,000 operations minimum (220V AC, 3A) 500,000 operations minimum (220V AC, 5A) Mechanical 50 million operations minimum 50 million operations minimum Note: See Operating Temperature - Maximum Switching Current Characteristics. Operating Temperature - Maximum Switching Current Characteristics Check the derating curve described below when mounting more than two GT5Y-2 timers and SM2S- 05∗ sockets. Mounting Direction 40ºC 50ºC 2.5A Operating Temperature Switching Current Derating Curve SM2S-05D, DF Sockets SM2S-05A, C Sockets Type List Package Quantity: 1 Operation Mode Contact Output Time Ranges (4 ranges selectable) Operating Voltage Type No. ON Delay DPDT 220V AC/ 30V DC, 5A 1S/10S/1M/10M 100 to 120V AC GT5Y-2SN1A100 3S/30S/3M/30M GT5Y-2SN3A100 6S/60S/6M/60M GT5Y-2SN6A100 1S/10S/1M/10M 200 to 240V AC GT5Y-2SN1A200 3S/30S/3M/30M GT5Y-2SN3A200 6S/60S/6M/60M GT5Y-2SN6A200 1S/10S/1M/10M 12V DC GT5Y-2SN1D12 3S/30S/3M/30M GT5Y-2SN3D12 6S/60S/6M/60M GT5Y-2SN6D12 1S/10S/1M/10M 24V DC GT5Y-2SN1D24 3S/30S/3M/30M GT5Y-2SN3D24 6S/60S/6M/60M GT5Y-2SN6D24 4PDT 220V AC/ 30V DC, 3A 1S/10S/1M/10M 100 to 120V AC GT5Y-4SN1A100 3S/30S/3M/30M GT5Y-4SN3A100 6S/60S/6M/60M GT5Y-4SN6A100 1S/10S/1M/10M 200 to 240V AC GT5Y-4SN1A200 3S/30S/3M/30M GT5Y-4SN3A200 6S/60S/6M/60M GT5Y-4SN6A200 3S/30S/3M/30M 12V DC GT5Y-4SN3D12 1S/10S/1M/10M 24V DC GT5Y-4SN1D24 3S/30S/3M/30M GT5Y-4SN3D24 6S/60S/6M/60M GT5Y-4SN6D24 Interval ON DPDT 220V AC/ 30V DC, 5A 1S/10S/1M/10M 100 to 120V AC GT5Y-2SV1A100 12V DC GT5Y-2SV1D12 24V DC GT5Y-2SV1D24 4PDT 220V AC/ 30V DC, 3A 100 to 120V AC GT5Y-4SV1A100 24V DC GT5Y-4SV1D24 Cycle DPDT 220V AC/ 30V DC, 5A 1S/10S/1M/10M 100 to 120V AC GT5Y-2SF1A100 4PDT 220V AC/ 30V DC, 3A 200 to 240V AC GT5Y-4SF1A200 24V DC GT5Y-4SF1D24 Note: S and M of the time range indicate second, and minute respectively. Accessories Both SY4S-05C and SM2S-05C are UL recognized, CSA certified, and TÜV approved. Others are UL recognized and CSA certified, except for SY4S-05A and SM2S-05A. When ordering, specify the ordering Type No. Item Type No. Ordering Type No. Package Quantity Remarks DIN Rail Mount Socket Socket SY4S-05A SY4S-05A 1 For 4PDT contact SY4S-05C SY4S-05C 1 For 4PDT contact SY4S-05D SY4S-05D 1 For 4PDT contact SY4S-05DF SY4S-05DF 1 For 4PDT contact SM2S-05A SM2S-05A 1 For DPDT contact SM2S-05C SM2S-05C 1 For DPDT contact SM2S-05D SM2S-05D 1 For DPDT contact SM2S-05DF SM2S-05DF 1 For DPDT contact Hold-Down Spring SFA-202 SFA- 202PN20 10 sets (20 pcs) For SY4S-05A, SM2S-05A (2 pcs/set) SFA-511 SFA- 511PN20

20 For SY4S-05D, SY4S-05DF,

SM2S-05D, SM2S-05DF Panel/ PC Board Mount Socket Socket SY4S-51 SY4S-51 1 For 4DPT contact, Solder Terminal SY4S-61 SY4S-61 1 For 4DPT contact, PC Board Terminal SM2S-51 SM2S-51 1 For DPDT contact, Solder Terminal SM2S-61 SM2S-61 1 For DPDT contact, PC Board Terminal Hold-Down Spring SFA-302 SFA- 302PN20 10 sets (20 pcs) For SY4S-51, SY4S-61, SM2S-51, SM2S-61 (2 pcs/set)

GT5Y Miniature Electronic Timers Control Units Display Lights Display Units Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References Flush Silhouette 1087 General Specifications Type GT5Y- oSN GT5Y- oSV GT5Y- oSF Operation Type ON Delay Interval Cycle Pollution Degree 2 (IEC60664-1) Overvoltage Category III (IEC60664-1) Rated Operational Voltage A200 200 to 240V AC (50/60Hz) A100 100 to 120V AC (50/60Hz) D24 24V DC D12 12V DC Voltage Range A200 170 to 264V AC (50/60Hz) A100 85 to 132V AC (50/60Hz) D24 21.6 to 26.4V DC D12 10.8 to 13.2V DC Reset Voltage Rated Voltage × 20% minimum Operating Temperature -10 to +50°C (no freezing and condensation) Storage/Transporta- tion Temperature -30 to +80°C (no freezing and condensation) Operating Humidity 35 to 85% RH (no condensation) Altitude 0 to 2000m (operation) 0 to 3000m (transportation) Reset Time 100 ms maximum Repeat Error ±0.2%, ±20 ms maximum Voltage Error ±0.5%, ±20 ms maximum Temperature Error ±3% maximum Setting Error ±10% maximum Insulation Resistance 100 MΩ minimum (500V DC megger) Dielectric Strength Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole: 1000V AC, 1 minute Vibration Resistance 10 to 55 Hz, amplitude 0.75 mm, 2 hours each in 3 direc- tions Shock Resistance Operating extremes: 98 m/s Damage limits: 490 m/s 2, 3 shocks each in 6 directions Degree of Protection IP40 (timer), IP20 (socket) (IEC60529) Power Consumption (approx.) A200 1.6 VA (200V AC/60Hz) A100 1.4 VA (100V AC/60Hz) D24 1.0W D12 0.9W Dimensions 27.5H × 21.0W × 58.6D mm Weight (approx.) 50g Note: See Operating Temperature – Maximum Switching Current Charac- teristics. Electrical Life Curves 5000 1000 500 100 0 12345 Load Current (A) Life (× 10,000 operations) GT5Y-2 GT5Y-4 AC Load 110V AC Resis. Load 220V AC Resis. Load 110V AC Induc. Load 220V AC Induc. Load 5000 1000 500 100 0 12345 GT5Y-2 GT5Y-4 DC Load 30V DC Resis. Load 30V DC Induc. Load 100V DC Resis. Load 100V DC Induc. Load Load Current (A) Life (× 10,000 operations) Dimensions (When using DIN Rail Mount Socket) GT5Y-4 See page 1113 for SY4S-05A, SY4S-05C, SY4S-05D, SY4S-05DF. (When using DIN rail) BAA, BAP: 87.6 max. (Note 2) DINHold- Down Spring Rail 27.5 21 6 52.6 6.4 58.6 18.5 83.6 max. (Note 1) max., SY4S-05DF: 88.6 max. max., SY4S-05DF: 92.8 max. Operation Charts and Internal Connections Operation Mode Item Operation ON Delay Set TimeTerminal No. 13-14 (POWER) POWER Indicator OUT Indicator Interval ON Set TimeTerminal No. 13-14 (POWER) POWER Indicator OUT Indicator Cycle TT Set Time Terminal No. 13-14 (POWER) POWER Indicator OUT Indicator (Internal Connections) GT5Y-4 /K34/K33/K32/K37/K36 /K31/K31/K31/K30 /K35 /K39/K31 /K32 /K38/K31 /K31/K33 /K31/K34 /K28/K7E/K2F/KD0/K29 /K28/K7E/K2F/K2B/K29

  • GT5Y-4 /K34/K35 /K39/K31 /K32 /K38/K31 /K31/K33 /K31/K34 /K28/K7E/K2F/KD0/K29 /K28/K7E/K2F/K2B/K29 GT5Y-2 See page 1112 for SM2S-05A, SM2S-05C, SM2S-05D, SM2S-05DF. (When using DIN rail) BAA, BAP: 87.6 max. (Note 4) 27.5 21 6 52.6 6.4 58.6 318.5 83.6 max. (Note 3) Hold- Down Spring DIN Rail max., SM2S-05DF: 88.6 max. max., SY4S-05DF: 92.8 max.

GT5P Miniature Electronic Timers 1088 Type No. Package Quantity: 1 Operation Mode Con- tact Output Time Range Operating Voltage Type No. (Order No.) ON Delay SPDT 24V DC/ 120V AC, 5A 240V AC, 3A 100 to 120V AC GT5P-N3SA100 10S GT5P-N10SA100 30S GT5P-N30SA100 60S GT5P-N60SA100 3M GT5P-N3MA100 6M GT5P-N6MA100 10M GT5P-N10MA100 200 to 240V AC GT5P-N1SA200 6S GT5P-N6SA200 10S GT5P-N10SA200 30S GT5P-N30SA200 60S GT5P-N60SA200 3M GT5P-N3MA200 6M GT5P-N6MA200 10M GT5P-N10MA200 24V AC/DC GT5P-N1SAD24 6S GT5P-N6SAD24 10S GT5P-N10SAD24 60S GT5P-N60SAD24 6M GT5P-N6MAD24 10M GT5P-N10MAD24 10S 12V DC GT5P-N10SD12 30S GT5P-N30SD12 60S GT5P-N60SD12 10M GT5P-N10MD12 Cycle SPDT 24V DC/ 120V AC, 5A 240V AC, 3A 3S 100 to 120V AC GT5P-F3SA100 10S GT5P-F10SA100 3S 200 to 240V AC GT5P-F3SA200 10S GT5P-F10SA200 3S 24V AC/DC GT5P-F3SAD24 10S GT5P-F10SAD24 3S 12V DC GT5P-F3SD12 10S GT5P-F10SD12 One Shot SPDT 24V DC/ 120V AC, 5A 240V AC, 3A 3S 100 to 120V AC GT5P-P3SA100 3S 200 to 240V AC GT5P-P3SA200 10S GT5P-P10SA200 3S 24V AC/DC GT5P-P3SAD24 10S GT5P-P10SAD24 Note: S and M of time range indicate second and minute respectively. Accessories Item Type No. Ordering Type No. Package Quantity Remarks DIN Rail Mount Socket Socket SR2P-06A SR2P-06A 1 SR2P-05A SR2P-05A 1 SR2P-05C SR2P-05C 1 UL/CSA/TÜV Hold-Down Spring SFA-202 SFA-202PN20 10 sets (20 pcs) For SR2P-06A (2 pcs/set) SFA-203 SFA-203PN20 10 sets (20 pcs) For SR2P-05A (2 pcs/set) Panel Mount Socket w/Solder Terminals SR2P-511 SR2P-511 1 UL/CSA w/Wire Wrap Terminals SR2P-70 SR2P-70 1 Economic Efficiency Focused Delayed Output SPDT/5A Three operation modes: ON Delay, Cycle, and One Shot Repeat error: ±0.2% maximum Complies with safety standards UL recognized, CSA certified, TÜV approved, EN compliant Time Ranges Code Time Range 1S 0.1 sec to 1 sec 3S 0.1 sec to 3 sec 6S 0.1 sec to 6 sec 10S 0.2 sec to 10 sec 30S 0.5 sec to 30 sec 60S 1 sec to 60 sec 3M 3 sec to 3 min 6M 6 sec to 6 min 10M 10 sec to 10 min Contact Ratings Contact Configuration SPDT Maximum Switching Voltage 250V AC, 150V DC Maximum Switching Current 5A Maximum Switching Power AC: 960VA DC: 120W Rated Load Resistive Load 120V AC / 24V DC, 5A 240V AC, 3A Inductive Load cosø = 0.3 - 0.4 L/R = 15 ms 240V AC, 0.8A 120V AC, 1.4A 24V DC, 1.7A Life Electrical 100,000 operations minimum (rated resistive load) Mechanical 20,000,000 operations minimum Minimum Applicable Load: 5V DC 10 mA (reference value)

GT5P Miniature Electronic Timers Control Units Display Lights Display Units Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References Flush Silhouette 1089 General Specifications Type GT5P-N GT5P-F GT5P-P Operation Type ON Delay Cycle One Shot Pollution Degree 2 (IEC60664-1) Rated Operational Voltage A200 200 to 240V AC (50/60Hz) A100 100 to 120V AC (50/60Hz) AD24 24V AC (50Hz/60Hz)/24V DC D12 12V DC Voltage Range A200 170 to 264V AC (50/60Hz) A100 85 to 132V AC (50/60Hz) AD24 20.4 to 26.4V AC (50/60Hz)/21.6 to 26.4V DC D12 10.8 to 13.2V DC Operating Temperature –10 to +50°C (no freezing) Storage/Transporta- tion Temperature –30 to +70°C (no freezing) Operating Humidity 35 to 85% RH (no condensation) Altitude 0 to 2000m (operation) 0 to 3000m (transportation) Reset Time 100 ms maximum Repeat Error ±0.2%, ±10 ms maximum Voltage Error ±0.5%, ±20 ms maximum Temperature Error ±3% maximum Setting Error ±10% maximum Insulation Resistance 100 M Ω minimum (500V DC megger) Dielectric Strength Between power and output terminals: 2000V AC, 1 minute Between contacts of different poles: 2000V AC, 1 minute Between contacts of the same pole: 750V AC, 1 minute Vibration Resistance 10 to 55Hz, amplitude 0.75 mm, 2 hours each in 3 directions Shock Resistance Operating extremes: 98 m/s Damage limits: 490 m/s 2 Power Consumption (approx.) A200 3.9 VA (60Hz) 5.6 VA (60Hz) A100 2.3 VA (60Hz) 2.9 VA (60Hz) AD24 1.3 VA (60Hz)/0.5W 1.2 VA (60Hz)/0.5W D12 0.6W 0.6W Dimensions 36H × 29W × 81.5D mm Weight (approx.) 49g Electrical Life Curves 100 012345 Life ( ×10,000 operations) Load Current (A) 24V DC Resis. load120V AC Resis. load 240V AC Resis. load 24V DC τ = 15 ms 120V AC cos ø = 0.4 240V AC cos ø = 0.4 Dimensions (When using DIN Rail Mount Socket) SR2P-05A For SR2P-05C, see page 1109. Note 1: SR2P-05C: 99.5 max. Note 2: SR2P-05C: 103.5 max. Operation Charts and Internal Connections Operation Mode Item Operation On Delay Set TimeTerminal No. 2-7 (POWER) POWER Indicator OUT Indicator 5-8 (NC) 6-8 (NO) Cycle TT Set Time Terminal No. 2-7 (POWER) POWER Indicator OUT Indicator 5-8 (NC) 6-8 (NO) One Shot 50ms minimum 3-4 (Start Input) Terminal No. 13-14 (POWER) POWER Indicator OUT Indicator 5-8 (NC) 6-8 (NO) (Internal Connections) ON Delay/Cycle 7(~)/( )+ 2(~)/(-) One Shot 2(~)/(-) 7(~)/( )+ SR2P-06B•

GT5Y/GT5P Miniature Electronic Timers [Common] Dimensions / Mounting Hole Layout (for Panel/PC Board Mount Socket) 1. GT5Y-4 Panel Mount Socket (SY4S-51) PC Board Mount Socket (SY4S-61) 2. GT5Y-2 Panel Mount Socket (SM2S-51) PC Board Mount Socket (SM2S-61) 3. GT5P Solder Terminal (SR2P-511)• Wire Wrap Terminal (SR2P-70)• Installation of Hold-Down Springs DIN Rail Mount Socket Note: Once installed into sockets, the hold-down springs cannot be removed.

  • Panel/PC Board Mount Socket The SFA-302 Hold-Down Springs can be installed to the SY4S-51, SY4S-61, SM2S-51, and SM2S-61 sockets. Hold-down springs cannot be installed to SR2P-511 and SR2P-70 panel mount sockets.

Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References Flush Silhouette 1091 GT5Y/GT5P Miniature Electronic Timers [Common] ! Safety Precautions Be sure to turn off power before mounting, removal, wiring, main- tenance and inspection. Otherwise, electric shock or fire could occur. Be sure to use timers within rated specification values. Otherwise, electric shock or fire may occur. Be sure to use wires to meet voltage and current requirements and tighten M3.5 terminal screws to a tightening torque of 1.0 to 1 .3 N•m. Be sure to solder the terminals correctly . Loose termi- nal screws or incomplete soldering may cause abnormal heat and fire. Instructions Time Range Setting The time range is calibrated at its maximum time scale, therefore it is desirable to use the timer at a setting as close to its maximum time scale as possible for accurate time delay. For a more accurate time delay, adjust the control knob by measuring the operating time with a watch before application. On the GT5Y timers, a desired time range can be selected using the time range selectors on the side surface. Turn the multiplier and time unit selectors using a flat screwdriver until they click. Time range selector Time range indication window Control knob Timing Accuracy Timing accuracies are calculated from the following formulas: Repeat Error Max. measured value - Min. measured value Maximum scale value 2= ± × × 100 (%) Voltage Error Tv - Tr Tr= ± × 100 (%) Tv: Average of measured values at voltage V Tr: Average of measured values at the raged voltage Temperature Error Tt - T20 T20 = ± × 100 (%) Tt: Average of measured values at t°C T20: Average of measured values at 20°C Setting Error Average of measured values - Set value Maximum scale value= × 100 (%) Use of External Input (GT5P-P Only) 1. Do not apply voltage to external input terminals 3 and 4. Be sure not to connect external inputs to other terminals because the internal circuit may be damaged. 2. Use reliable mechanical contacts capable of switching approxi- mately 22V DC, 1 mA to close input terminals 3 and 4. (Closed: 1 kΩ maximum, Open: 100 kΩ minimum) The input terminals should not be connected to a ground wire of other de- vices. 3. Do not install input lines in parallel with high-voltage or motor lines. Use shielded wires or separate conduit for input lines, and make the input lines as short as possible. Load Current The rated current of the contact (or control output) should not be ex- ceeded. Especially for inductive, capacitive, and incandescent lamp loads, the inrush current as large as a few to several tens times the rated current may cause welded contacts and other troubles. The amount of inrush current as well as steady-state current must be taken into consideration. Contact Protection Switching an inductive load generates a counter-electromotive force in the coil. The counter emf will cause arcing, which may shorten the contact life. Application of a protection circuit is recommended for contact protection. Rest Time When turning power off after time-out, allow a rest time of 0.1 sec, and during operation, 1 sec at least. Power Since DC types are designed to operate on DC power containing 10% or less ripple, insert a smoothing circuit when using a rectified AC power to operate DC type timers. Continuous Energizing Continuous energizing for a long period of time may damage the electrical characteristics of the timer because of internal heating. Use an additional relay to the output circuit and refrain from continu- ous energizing of the timer. Dielectric Strength Test When performing an insulation resistance or dielectric strength test on control panels containing timers, make sure that the dielectric strength of the timer is not exceeded. In case the dielectric strength is exceeded, remove the timers from the panels. Operating Environment Temperature and Humidity Use the timer within the operating temperature and operating hu- midity ranges and prevent freezing and condensation. After stor- ing below the operation temperature, leave the timer at room tem- perature for a sufficient period of time before use. Environment Prevent a corrosive gas such as sulfurous or ammonia gas, or- g a n i c s o l v e n t s ( a l c o h o l , b e n z i n e , t h i n n e r , e t c . ) , s t r o n g a l k a l i n e substances or strong acids from touching to the timer, and do not use the timer in such an environment. Keep the timer from water splashes or steam. Vibration and Shock Since excessive vibrations or shocks cause the output contacts to open, the timer should be used within the operating extremes of vibration and shock resistance. Use of hold-down springs is recommended for secure mounting on sockets. Others Use a mechanical-contact switch or relay to supply power to the time. When driving the timer using a solid-state output device such as two-wire proximity switch, photoelectric switch or solid-state relay directly, malfunction may be caused by a leakage current from the solid-state device. Be sure to check thoroughly before using. Since AC types (such as A100 and A200) comprise a capacitive load, the SSR dielectric strength should be two or more times as large as the power voltage when switching the timer power using an SSR. To make a sequence circuit by connecting timer and relay, check the timer operation sufficiently in consideration of the reset time of the timer.

GT5Y/GT5P Miniature Electronic Timers [Common] Installation/Removal of Hold-Down Springs Installation/Removal of Hold-Down Springs