GRAPHIC OPERATION TERMINAL User's Manual SeriesGOT SIMPLE
(Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. In this manual, the safety precautions are ranked as "WARNING" and "CAUTION". Note that the caution level may lead to a se rious accident according to the circumstances. Always follow the instructions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. [DESIGN PRECAUTIONS] WARNING
- Some failures of the GOT or cable may keep the outputs on or off. Some failures of a touch panel may cause malfunction of the input objects such as a touch switch. An external monitoring circuit should be provided to check for output signals which may lead to a serious accident. Not doing so can cause an accident due to false output or malfunction.
- Do not use the GOT as the warning device that may cause a serious accident. An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning. Not doing so can cause an accident due to false output or malfunction.
- When the GOT detects its backlight failure, the GOT disables the input operation on the touch switch(s). Thus, operators cannot operate the GOT with touches. The GOT backlight failure can be checked with a system signal of the GOT.
- Even when the display section has dimmed due to a failure of the liquid crystal section or the backlight on the GOT, the input operation of the touch switches may still be enabled. This may cause an incorrect operation of the touch switches. For example, if an operator assumes that the display section has dimmed because of the screen save function and touches the display section to cancel the screen save, a touch switch may be activated. WARNING Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
[DESIGN PRECAUTIONS] [MOUNTING PRECAUTIONS] WARNING
- The display section of the GOT is an analog-resistive type touch panel. Simultaneous pressing of two or more areas on the display section may activate the switch between those areas. Do not press two or more areas simultaneously on the display section. Doing so may cause an accident due to incorrect output or malfunction.
- When programs or parameters of the controller (such as a PLC) that is monitored by the GOT are changed, be sure to shut off the power of the GOT promptly and power on the GOT again. Not doing so can cause an accident due to false output or malfunction.
- If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative. A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur. Not doing so can cause an accident due to false output or malfunction. CAUTION
- Do not bundle the control and communication cables with main-circuit, power or other wiring. Run the above cables separately from such wiring and keep them a minimum of 100mm apart. Not doing so noise can cause a malfunction.
- Do not press the GOT display section with a pointed material as a pen or driver. Doing so can result in a damage or failure of the display section.
- When the GOT is connected to the Ethernet network, the available IP address is restricted according to the system configuration.
- When multiple GOTs are connected to the Ethernet network: Do not set the IP address (192.168.3.18) for the GOTs and the controllers in the network.
- When a single GOT is connected to the Ethernet network: Do not set the IP address (192.168.3.18) for the controllers except the GOT in the network. Doing so can cause the IP address duplication. The duplication can negatively affect the communication of the device with the IP address (192.168.3.18). The operation at the IP address duplication depends on the devices and the system.
- Turn on the controllers and the network devices to be ready for communication before they communicate with the GOT. Failure to do so can cause a communication error on the GOT.
- When the GOT is subject to shock or vibration, or some colors appear on the screen of the GOT, the screen of the GOT might flicker. WARNING
- Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT main unit to/from the panel. Not doing so can cause the unit to fail or malfunction.
[MOUNTING PRECAUTIONS] [WIRING PRECAUTIONS] CAUTION
- Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
- When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range (0.36N·m to 0.48N·m) with a Phillips-head screwdriver No.2. Undertightening can cause the GOT to drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT.
- Remove the protective film of the GOT. When the user continues using the GOT with the protective film, the film may not be removed.
- Operate and store the GOT in environments without direct sunlight, high temperature, dust, humidity, and vibrations.
- Do not use the GOT in an environment with oil or chemicals. Doing so may cause failure or malfunction due to the oil or chemical entering into the GOT. WARNING
- Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions. CAUTION
- Please make sure to ground FG terminal of the GOT power supply section by applying 100Ω or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
- Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.
- Tighten the terminal screws of the GOT power supply section in the specified torque range (0.5N to 0.6N·m). Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
- Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction.
- Plug the communication cable into the GOT interface or the connector of the connected unit, and tighten the mounting screws and the terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
[TEST OPERATION PRECAUTIONS] [STARTUP/MAINTENANCE PRECAUTIONS] WARNING
- Before performing the test operations of the user creation monitor screen (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method. During test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident. WARNING
- When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction.
- Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not doing so can cause the unit to fail or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit. CAUTION
- Do not disassemble or modify the unit. Doing so can cause a failure, malfunction, injury or fire.
- Do not touch the conductive and electronic parts of the unit directly. Doing so can cause a unit malfunction or failure.
- The cables connected to the unit must be run in ducts or clamped. Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
- When unplugging the cable connected to the unit, do not hold and pull from the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
- Do not drop the module or subject it to strong shock. A module damage may result.
- Before touching the unit, always touch grounded metals, etc. to discharge static electricity from human body, etc. Not doing so can cause the unit to fail or malfunction.
[TOUCH PANEL PRECAUTIONS] [PRECAUTIONS WHEN THE DATA STORAGE IS IN USE] [PRECAUTIONS WHEN THE DATA STORAGE IS IN USE] [DISPOSAL PRECAUTIONS] CAUTION
- For the analog-resistive film type touch panels, normally the adjustment is not required. However, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, execute the touch panel calibration.
- When any difference between a touched position and the object position occurs, other object may be activated. This may cause an unexpected operation due to incorrect output or malfunction. WARNING
- If the SD card mounted on drive A of the GOT is removed while the GOT is accessed, processing for the GOT might be interrupted about for 20 seconds. The GOT cannot be operated during this period. The functions that run in the background including a screen updating, alarm, logging, scripts, and others are also interrupted. Since this interruption makes an impact to the system operation, it might cause failure. After inhibiting access to the SD card on the GOT utility screen, check that the SD card access LED is off and remove the SD card. CAUTION
- If the data storage mounted on the GOT is removed while the GOT is accessed, the data storage and files are damaged. To remove the data storage from the GOT, check that the access to the data storage in SD card access LED, the system signal, and others is not performed.
- When removing the SD card from the GOT, make sure to support the SD card by hand as it may pop out. Failure to do so may cause the SD card to drop from the GOT, resulting in a failure or break.
- Before removing the USB device from the GOT, follow the procedure for removal on the utility screen of the GOT. After the successful completion dialog is displayed, remove the USB device by hand carefully. Failure to do so may cause the USB device to drop from the GOT, resulting in a failure or break. CAUTION
- When disposing of this product, treat it as industrial waste.
[TRANSPORTATION PRECAUTIONS] CAUTION
- Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of this manual, as they are precision devices. Failure to do so may cause the unit to fail. Check if the unit operates correctly after transportation.
- When fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine are used for disinfecting and protecting wooden packaging from insects, they cause malfunction when entering our products. Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products, or treat packaging with methods other than fumigation (heat method). Additionally, disinfect and protect wood from insects before packing products.
- OVERVIEW 2. SYSTEM CONFIGURATION 3. SPECIFICATIONS 4. PART NAME 5. EMC DIRECTIVE INTRODUCTION Thank you for choosing Mitsubishi Graphic Operation Terminal (Mitsubishi GOT). Read this manual and make sure you understand the functions and performance of the GOT thoroughly in advance to ensure correct use.
CONTENTS
- INSTALLATION 7. WIRING 8. OPTION 9. UTILITY FUNCTION 10. LANGUAGE SETTING (LANGUAGE) 11. COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
- DISPLAY AND OPERATION SETTINGS (GOT SET UP) 13. SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) 14. CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING AND DISPLAY)
- CONTROL OF VARIOUS DATA (DATA CONTROL) 16. GOT SELF CHECK (DEBUG)
- MAINTENANCE 18. INSTALLING PACKAGE DATA BY USING AN SD CARD 19. INSTALLATION OF BOOTOS AND BASIC SYSTEM APPLICATION 20. MAINTENANCE AND INSPECTION 21. TROUBLESHOOTING 22. CONNECTION
- APPENDIX REVISIONS WARRANTY
The following manuals related to this product are available. Refer to each manual in accordance with the intended use. Screen creation software manuals Connection manuals GOT SIMPLE series manuals Manual name Manual number (Model code) GT Works3 Installation Instructions - GT Designer3 (GOT2000) Help - GT Converter2 Version3 Operating Manual for GT Works3 SH-080862ENG (1D7MB2) Manual name Manual number (Model code) GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 SH-081197ENG (1D7MJ8) GOT2000 Series Connection Manual (Non Mitsubishi Product 1) For GT Works3 Version1 SH-081198ENG (1D7MJ9) GOT2000 Series Connection Manual (Non Mitsubishi Product 2) For GT Works3 Version1 SH-081199ENG (1D7MK1) GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT Works3 Version1 SH-081200ENG (1D7MK2) Manual name Manual number (Model code) GOT SIMPLE Series User's Manual JY997D52901
Creating projects Connecting a controller to the GOT Transferring data to the GOT Others Obtaining the specifications and operation methods of GT Designer3 GT Designer3 (GOT2000) Help Setting available functions on GT Designer3 Creating a screen displayed on the GOT Obtaining useful functions to increase efficiency of drawing Setting details for figures and objects Setting functions for the data collection or trigger action Setting functions to use peripheral devices Simulating a created project on a personal computer Obtaining information of Mitsubishi products applicable to the GOT GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 Connecting Mitsubishi products to the GOT Connecting multiple controllers to one GOT (Multi-channel function) Establishing communication between a personal computer and a controller via the GOT (FA transparent function) Obtaining information of Non-Mitsubishi products applicable to the GOT
- GOT2000 Series Connection Manual (Non Mitsubishi Product 1) For GT Works3 Version1
- GOT2000 Series Connection Manual (Non Mitsubishi Product 2) For GT Works3 Version1Connecting Non-Mitsubishi products to the GOT Obtaining information of peripheral devices applicable to the GOT GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT Works3 Version1 Connecting peripheral devices including a bar code reader to the GOT Writing data to the GOT GT Designer3 (GOT2000) HelpReading data from the GOT Verifying an editing project to a GOT project Obtaining the specifications and operation methods of GT Designer3 GOT SIMPLE Series User's Manual Setting available functions on GT Designer3 Creating a screen displayed on the GOT GOT SIMPLE Series User's Manual Obtaining useful functions to increase efficiency of drawing GT Designer3 (GOT2000) Help
Abbreviations and Generic Terms GOT Option Software (1) Software related to GOT Abbreviations and generic terms Description GOT SIMPLE Series GS21 GS2110-W GS2110-WTBD GS2107-W GS2107-WTBD GOT2000 Series GT27 GT2712-S GT2712-STBA, GT2712-STWA, GT2712-STBD, GT2712-STWD GT2710-S GT2710-STBA, GT2710-STBD GT2710-V GT2710-VTBA, GT2710-VTWA, GT2710-VTBD, GT2710-VTWD GT2708-S GT2708-STBA, GT2708-STBD GT2708-V GT2708-VTBA, GT2708-VTBD GT23 GT2310-V GT2310-VTBA, GT2310-VTBD GT2308-V GT2308-VTBA, GT2308-VTBD GT SoftGOT2000 GT SoftGOT2000 Version1 Abbreviations and generic terms Description SD card L1MEM-2GBSD, L1MEM-4GBSD Abbreviations and generic terms Description GT Works3 SW1DNC-GTW3-J, SW1DND-GTW3-J, SW 1DNC-GTW3-E, SW1DND-GTW3-E, SW1DND-GTW3-C GT Designer3 Version1 Screen drawing softwa re GT Designer3 for GOT2000/GOT1000 series GT Designer3 Screen drawing software for GOT2000 series included in GT Works3 GT Designer3 (GOT2000) GT Designer3 (GOT1000) Screen drawing software for GOT1000 series included in GT Works3 GT Simulator3 Screen simulator GT Simulator3 for GOT2000/GOT1000/GOT900 series
(2) Other software Others Abbreviations and generic terms Description GX Works2 SW DNC-GXW2-J (-JA, -JAZ) type programmable controller engineering software ( indicates a version.) GX Simulator2 GX Works2 with the simulation function GX Simulator SW D5C-LLT-J (-JV) type ladder logic test tool function software package (SW5D5C-LLT (-V) or later versions) ( indicates a version.) GX Developer SW D5C-GPPW-J (-JV)/SW D5F-GPPW (-V) type software package ( indicates a version.) GX LogViewer SW DNN-VIEWER-J type software package ( indicates a version.) PX Developer SW D5C-FBDQ-J type FBD software package for process control ( indicates a version.) MT Works2 Motion controller engineering environment MELSOFT MT Works2 (SW DNC-MTW2-J) ( indicates a version.) MT Developer SW RNC-GSV type integrated start-up support software for motion controller Q series ( indicates a version.) MR Configurator2 SW DNC-MRC2-J type servo configuration software ( indicates a version.) MR Configurator MRZJW -SETUP type servo configuration software ( indicates a version.) FR Configurator Inverter setup software (FR-SW -SETUP-WJ) ( indicates a version.) NC Configurator CNC parameter setting support tool NC Configurator FX Configurator-FP Parameter setting, monitoring, and testing software packages for FX3U-20SSC-H (SW D5CFXSSCJ) ( indicates a version.) FX3U-ENET-L Configuration tool FX3U-ENET-L type Ethernet module setting software (SW1D5-FXENETL-J) RT ToolBox2 Robot program creation software (3D-11C-WINJ) MX Component MX Component Version (SW D5C-ACT-J, SW D5C-ACT-JA) ( indicates a version.) MX Sheet MX Sheet Version (SW D5C-SHEET-J, SW D5C-SHEET-JA) ( indicates a version.) QnUDVCPU LCPU Logging Configuration Tool QnUDVCPU LCPU Logging Configuration Tool (SW1DNN-LLUTL-J) Abbreviations and generic terms Description SIEMENS Siemens AG PLC Programmable controller manufactured by each corporation
- OVERVIEW ■1. About GOT A GOT is installed on the panel surface of a control panel or operating panel and connects to the PLC within the control panel. The GOT carries out switch operation, lamp display, data display, message display, etc. For the display screen, two kinds of screens are available: user screen and utility screen. (1) User screen The user screen is a screen drawn by drawing software. The objects "Touch switch", "Lamp display", "Comment display", and "Numeric display" can be arbitrarily arranged on the display. Moreover, multiple screens created within drawing software can be individually selected or overlapped for the display. For details, refer to the following. ➠ GT Designer3 (GOT2000) Help (2) Utility Screen The utility screen is a factory drawn horizontal screen that cannot be edited. The utility screen can be displayed on the GOT by installing the standard monitor OS from drawing software or an SD card to the GOT. Such as [Brightness] and [Time setting] can be set from the utility screen. For details, refer to the following. ➠ 9. to 21. PLC Connector for program GOT
1 - 2 1.1 Features
1.1 Features
Monitoring for turning on or off bit devices of a PLC, forcibly turning on or off the bit devices of a PLC, monitoring the word device set value/current value and changing that numeric values are easily made. (1) The display unit is used for engineers' stag e replacement, setting change and troubleshooting or for operation guidance to an operator.
- Monitor
- Forcibly turning on or off
- Set value change
- Trouble check (2) Improved monitoring performance and connectivity to FA devices
- Multiple languages are displayed using the Unicode2.1-compatible fonts and beautiful characters are drawn using the TrueType and high quality fonts
- Two types of display modes are available: 65536-color display and monochrome A fine and beautiful full-color display which shows even small characters clearly, is enabled in the 65536-color display by adopting the high intensity, wide viewing angle and high definition TFT color liquid crystal display. (Also compatible with digital screen displays with 65536 colors, BMP, etc.) High speed monitoring through high speed communication at maximum of 115.2kbps
- High speed display and high speed touch switch response
- The operation performance is improved by the analog touch panel. (3) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works
- The 9MB built-in flash memory is included as standard.
- SD card interface is included as standard.
- RS-232 interface is included as standard.
- RS-422 interface is included as standard.
- USB interface (device) is included as standard.
- Ethernet interface is included as standard.
- System font types are increased by the adoption of the font installation system.
- Four types of alarms (system alarm, user alarm, alarm history and alarm popup display) are integrated, and realizing an efficient alarm notification. (4) Enhanced support of FA setup tools
- Transferring or monitoring the sequence programs using the personal computer connected to GOT, during connection to L, Q, QnA, or FX series PLC CPU (FA transparent function)
1.1 Features 1 - 3
1.1.1 Rough procedure
The following shows the procedures before operating a GOT and the descriptions of each item. Install GT Designer3 in a personal computer. ➠ Refer to the setting method of GT Works3. ➠ Refer to GS21 GOT General Description. Create project data. ➠ Refer to GT Designer3 (GOT2000) Help. Wire for the GOT power supply and the controller. ➠ 7. WIRING ➠ Refer to GOT2000 Series Connection Manual for GT Works3 Version1. Wire for the controller power supply and I/O. ➠ Controller manuals Turn on the power of the GOT and controller. Install the OS to the GOT. ➠ Refer to GT Designer3 (GOT2000) Help. Check that the OS is installed to the GOT. Download project data. ➠ Refer to GT Designer3 (GOT2000) Help. Turn on the controller power and check that the GOT recognizes the controller. Check that the monitoring is normal.
1 - 4 1.1 Features
2.1 Overall Configuration 2 - 1
- SYSTEM CONFIGURATION
2.1 Overall Configuration
The overall configuration of GOT is as follows. For the connection methods applicable to GS series and cable, refer to the following. ➠ GOT2000 Series Connection Manual For GT Works3 Version1 *1 Only hard copy of the screen can be printed.
2.2 Component List
(1) Explanation of the GOT model name Bar code reader (Commercially available) Personal computer (Commercially available) Printer*1 (Commercially available) SD card GS21 series 07 - W Panel color type 10 : 10" 07 : 7" Display color type W : 800×480Resolution D : DC24VPower type T : TFT colorDisplay device type B : Black TBDG S 2 1
2 - 2 2.2 Component List
2.2.1 GOT
2.2.2 Option
■1. Connection cables for MITSUBISHI PLCs (Sold separately) ■2. Connection cables for SIEMENS PLCs (Sold separately)] ■3. SD card (Sold separately) *1 Some models with the operations checked by our company are usable. For the operation-checked models, refer to "Operation Check Results of Third Party SD Cards on GT14 Model" (Hime-T-P-0089) separately available, or contact your local distributor. Product name Model Specifications GOT GS2110-WTBD 10" [800 480 dots], TFT color liquid crystal, 65536 colors 24VDC, Memory capacity: 9MB, built-in Ethernet interface GS2107-WTBD 7" [800 480 dots], TFT color liquid crystal, 65536 colors 24VDC, Memory capacity: 9MB, built-in Ethernet interfaceProduct name Model Cable length Description RS-422 Cable FXCPU direct connection cable, FX expansion board connection cable GT01-C10R4-8P 1m For connecting FXCPU (MINI DIN 8 pins connector) and GOT For connecting FXCPU expansion board (MINI DIN 8 pins connector) and GOT GT01-C30R4-8P 3m GT01-C100R4-8P 10m GT01-C200R4-8P 20m GT01-C300R4-8P 30m QnA/A/FXCPU direct connection cable, computer link connection cable GT01-C30R4-25P 3m QnA/A motion controller (A series) For connecting FXCPU (D-Sub 25 pins connector) and GOT For connecting FA-CNV CBL and GOT For connecting serial communication unit (AJ71QC24(N)-R4) and GOT GT01-C100R4-25P 10m GT01-C200R4-25P 20m GT01-C300R4-25P 30m Computer link connection cable GT09-C30R4-6C 3m For connecting computer link unit/serial communication unit and GOT GT09-C100R4-6C 10m GT09-C200R4-6C 20m GT09-C300R4-6C 30m RS-232 cable QCPU direct connection cable GT01-C30R2-6P 3m For connecting QCPU and GOT FX expansion board connection cable, FX special adaptor connection cable GT01-C30R2-9S 3m For connecting FXCPU expansion board (D-Sub 9 pins connector) and GOT For connecting FXCPU special adaptor (D-sub 9 pins connector) and GOT FX special adaptor connection GT01-C30R2-25P 3m For connecting FXCPU special adaptor (D-sub 25 pins connector) and GOT Computer link connection cable GT09-C30R2-9P 3m For connecting computer link unit/serial communication unit and GOTGT09-C30R2-25P 3m Product name Model Cable length Description RS-232 cable GT09-C30R20801-9S 3m For connecting SIEMENS HMI Adapter and GOT Product name Model Description SD card L1MEM-2GBSD SD memory card 2GB L1MEM-4GBSD SDHC memory card 4GB - Commercially-available SD card*1
2.2 Component List 2 - 3
■4. Drawing software (Sold separately) *1 If you need two licenses or more, request the number of lice nses. For details, consult your local Mitsubishi representative. *2 Up to 200 licenses can be registered per site license product. However, this applies only to the same corporation or business facility where the product is purchased. *3 Site license products, multiple-license pr oducts, and additional license products can be provided. For details, refer to MELSOFT iQ Works catalog <L(NA)08232ENG>. *4 This product includes the following software.
- System management software [MELSOFT Navigator]
- PLC engineering software [MELSOFT GX Works2]
- Motion controller engineering software [MELSOFT MT Works2]
- Servo setup software [MELSOFT MR Configurator2]
- GOT screen creation software [MELSOFT GT Works3]
- Robot programming software [MELSOFT RT ToolBox2 mini] ■5. PC connection cable (Sold separately) ■6. Bar code reader (Sold separately) *1 Some models with the operations checked by our company are usable. For the operation-checked models, contact your local distributor. Product name Model Description GOT screen creation software MELSOFT GT Works3 Version1 SW1DND-GTWK3-J Standard license product DVD product SW1DND-GTWK3-JC Site license product SW1DND-GTWK3-JA Multiple-license product *1 SW1DND-GTWK3-JAZ Additional license product *1 SW1DND-GTWK3-JV Standard license product (For upgrading version) (For upgrading version of user's GT Designer2/ GT Works2 to the latest one) FA integration engineering software MELSOFT iQ Works *3*4 SW1DND-IQWK-J Standard license product SW1DNC-IQWK-J CD-ROM product Product name Model Cable length Description Project data transfer cable GT09-C30USB-5P 3m For connecting GOT (USB Mini-B) and personal computer (USB) Product name Model Description Bar code - Commercially-available bar code reader*1
2 - 4 2.2 Component List
3.1 General Specifications 3 - 1
- SPECIFICATIONS
3.1 General Specifications
*1 Do not use or store the GOT under pressures higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe th is instruction may cause a malfunction. When the air inside the control panel is purged by pressurization, the surface sheet may be lifted by high pressure. As a result, the touch panel may be difficult to press, and the sheet may be peeled off. *2 This indicates the section of the power supply to which the e quipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises. Category II applies to equipment for which electrical power is supplied from fixed facilities. The surge voltage withstand level for up to the raged voltage of 300V is 2500V. *3 This index indicates the degree to which conductive pollution is generated in the environment where the equipment is used. In pollution degree 2, only non-conductive pollution occurs but temporary conductivi ty may be produced due to condensation. Item Specifications Operating ambient temperature 0 to 50°C Storage ambient temperature -20 to 60°C Operating/Storage ambient humidity 10 to 90%RH, non-condensing (The wet bulb temperature is 39°C) When the ambient temperature exceeds 40°C, maintain the absolute humidity at 40°C and 90%. Vibration resistance Conforms to IEC 61131-2 Frequency Acceleration Half amplitude Sweep Count Under intermittent vibration 5 to 8.4Hz - 3.5mm 10times each in X, Y and Z directions8.4 to 150Hz 9.8m/s 2 - Under continuous vibration 5 to 8.4Hz - 1.75mm 8.4 to 150Hz 4.9m/s 2 - Shock resistance Conforms to IEC 61131-2 (147m/s2, 3times each in the X, Y, and Z directions) Operating atmosphere Must be free of lamp black, corrosive gas, flammable gas, or excessive amount of electro conductive dust particles. Must be no direct sunlight. (Same as for saving) Operating altitude *1 2000m (6562ft) max. Overvoltage category*2 II or less Pollution degree*3 2 or less Cooling method Self-cooling Grounding Class D grounding (100Ω or less), To be connected to the panel when grounding is not possible.
3 - 2 3.2 Performance Specifications
3.2 Performance Specifications
The following shows the performance specifications. Item Specifications GS2110-WTBD GS2107-WTBD Display section*1 Type TFT color liquid crystal Screen size 10" 7" Resolution 800 480 [dots] Display size W222(8.74) H132.5(5.22) mm (Horizontal format) (Horizontal format) Display character 16-dot standard font: 50 characters 30 lines (Horizontal format) Display color 65536 colors Brightness 32-level adjustment Backlight LED-type (no replacement required) Backlight off/screen saving time can be set. Touch panel Type Analog-resistive film type Key size Minimum 2 2 [dots] (per key) Number of points touched simultaneously Simultaneous 2-point presses prohibited (Only one point can be touched.) Life 1 million times (operating force 0.98N max.) Memory C drive Flash memory (Internal) (9Mbytes), for storing project data, OS Life (Number of write times) 100,000times Built-in interface RS-422 RS-422, 1ch Transmission speed: 115200/57600/38400/19200/9600/4800bps Connector shape: D-sub 9 pins (Female) Application: For communicating with controllers Terminating resistor: 330Ω fixed RS-232 RS-232, 1ch Transmission speed: 115200/57600/38400/19200/9600/4800bps Connector shape: D-sub 9 pins (Male) Application: For communication with controllers and a bar code reader For PC connection (Project data upload/download, FA transparent function) Ethernet Data Transfer method: 100BASE-TX, 10BASE-T, 1ch Connector shape: RJ-45 (modular jack) Application: For communication with controllers For PC connection (Project data upload/download, FA transparent function) USB USB (Full Speed 12Mbps) 1ch Connector shape: Mini-B Application: For PC connection (Project data upload/download, FA transparent function) SD card Conforms to the SD standard, 1ch Supported memory card: SDHC memory card, SD memory card Application: Project data upload/download, logging data save Buzzer output Single tone (LONG/SHORT/OFF adjustable) Protective structure *3 IP65F (only the front part of the panel) External dimensions W272(10.71) H214(8.43) D56(2.21) [mm] (inch) (inch) Panel cutting dimensions W258(10.16) H200(7.88) [mm] (inch) (Horizontal format) W191(7.52) H137(5.40) mm (Horizontal format) Weight Approx. 1.3kg (Excluding mounting fixtures) Approx. 0.9kg (Excluding mounting fixtures) Compatible software package (Version of GT Designer3) Version1.104J or later
3.3 Power Supply Specifications 3 - 3
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely a void this symptom, as the liquid crystal display comprises of a great number of display elements. Flickers and partial discoloration may be generated on the liquid crystal display panel due to individual differences of panels. Please note that these phenomena appear due to its characteristic and are not caused by product defect. *2 The touch panel is an analog-resistive type. Simultaneous pressi ng of two or more areas on the touch panel may activate the switch between those areas. Do not press two or more areas simultaneously on the touch panel. *3 Note that this does not guarantee all users' operation environ ment. In addition, the product may not be used in environments under exposition of oil or chemicals for a long period of time, or in environments filled with oil-mist.
3.3 Power Supply Specifications
Operation at momentary power failure The GOT continues to operate even upon 5ms or shorter instantaneous power failure. The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored. Item Specifications GS2110-WTBD GS2107-WTBD Input power supply voltage 24VDC (+10% -15%), ripple voltage 200mV or less Power consumption 7.6W (317mA/24V) or less 6.5W (271mA/24V) or less At backlight off 3.8W (158mA/24V) or less 3.8W (158mA/24V) or less Inrush current 17A or less (6ms, 25°C, at the maximum load) Permissible instantaneous power failure time Within 5ms Noise immunity Conforms to IEC6 1000-4-4, 2kV (power supply line) Dielectric withstand voltage 350VAC for 1 mi nute (across power supply terminals and earth) Insulation resistance 500VDC across power terminals and earth, 10 MΩ or more by an insulation resistance tester
3 - 4 3.4 GOT Connector Specifications
3.4 GOT Connector Specifications
The following shows the specifications of connectors for the GOT. Refer to this section for creating a connection cable by the user.
3.4.1 RS-232 interface
The following shows the connector for the RS-232 interface of the GOT. For the connection cable connector of the GOT side, use a connector and a connector cover which can be connected to the GOT connector. ■1. Connector specifications ■2. Connector pin arrangement
3.4.2 RS-422 interface
The following shows the connector for the RS-422 interface of the GOT. For the connection cable connector of the GOT side, use a connector and a connector cover which can be connected to the GOT connector. ■1. Connector model ■2. Connector pin arrangement GOT Connector type Connector model Manufacturer GS series D-sub 9 pins (Male) Inch screw type 17LE-23090-27(D3CC) DDK Ltd. GOT Connector type Connector model Manufacturer GS series D-sub 9 pins (Female) M2.6 mm screw type 17LE-13090-27(D3AC) DDK Ltd. D-Sub 9pin male GOT main part connector see from the front D-Sub 9pin female GOT main part connector see from the front
4.1 Front Panel 4 - 1
- PART NAME
4.1 Front Panel
No. Name Specifications (1) Display section Displays the uti lity screen and the user creation screen. (2) Touch panel For operating the touch switches in the utility screen and the user creation screen (1)(2)
4 - 2 4.2 Back Panel
4.2 Back Panel
No. Name Specifications (1) RS-232 interface For communicating with controller (PLC, microcomputer board, RFID, etc) or personal computer (OS installation, project data download, FA transparent) (D-sub 9-pin male) (2) RS-422 interface For communicating with controller (PLC, microcomputer board, etc) (D-sub 9-pin female) (3) Ethernet interface For Ethernet communication with cont roller (PLC, microcomputer board, etc) (RJ-45 connector) (4) USB interface USB interface (hos t) for data transfer and saving (5) Hole for preventing the USB cable from unplugging Hole for preventing the USB cable from unplugging with a banding band (6) Rating plate (nameplate) Model name, current consumption, production number, hardware version, and BootOS version are described. (7) SD card interface Interface for mounting an SD card to the GOT (8) SD card access LED ON: SD card is accessed, OFF: SD card is not accessed (9) Power terminal Power terminal and FG termi nal (for power supply (24VDC) to GOT and grounding) (10) Ethernet communication status LED SD RD: Green light while data are being sent or received, 100M: Green light when the transmission speed is 100Mbps (6) (10) (4) (8) (7) (2)(1)(3) (9) (5) (6) (7) (8) (5)(2) (4) (1)(3) (9) (10)
4.3 Bottom 4 - 3
4.3 Bottom
No. Name Specifications (1) Hole for unit installation fittings Hole for the inserting installation fittings (accessory) during the GOT installation to the panel (4 holes at top and bottom) (1) (1)
4 - 4 4.3 Bottom
5.1 Overview 5 - 1
- EMC DIRECTIVE
5.1 Overview
For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives, has been a legal obligation since 1996. Manufacturers, who recognize that their products comply with the EMC Directive must declare that their products comply with the Directives and put a CE mark on the products. ■1. Sales representative in Europe The sales representative in Europe is as shown below. Company name: Mitsubishi Electric Europe BV Address: Gothaer strase 8, 40880 Ratingen, Germany
5.1.1 Conforming standards in the EMC Directive
The GOT complies with the following standards in the EMC Directive. *1 The GOT is an open type device (designed to be integrated in equipment). Make sure to install the GOT on a control panel. This test item is conducted in the condition where the GOT is installed on a control panel and combined with the MITSUBISHI PLC. *2 QP: Quasi-peak value, Mean: Average value *3 This test item is conducted in the following conditions.
- 30 MHz to 230 MHz QP: 40 dBμV/m (measured at 10 m)
- 230MHz to 1000MHz QP: 47 dBμV/m (measured at 10 m) Applied standard Test standard Test details Standard value EN61131-2 : 2007 CISPR16-2-3 Radiated noise*1 Test for measuring electromagnetic emissions from the product
- 30 MHz to 230 MHz QP: 30 dBμV/m (measured at 30 m)*2*3
- 230MHz to 1000MHz QP: 37 dBμV/m (measured at 30 m)*2*3 IEC61000-4-2 Electrostatic immunity*1 Immunity test in which static electricity is applied to the cabinet of the equipment
- Contact discharge: ±4 kV
- Aerial discharge: ±8 kV IEC61000-4-3 Radiated electromagnetic field, amplitude modulation Immunity test in which an electric field is applied to the product
80 MHz to 1000 MHz: 10 V/m
1.4GHz to 2GHz: 3V/m 2.0GHz to 2.7GHz: 1V/m (80% amplitude modulation at 1 kHz) IEC61000-4-4 Fast transient burst noise Immunity test in which burst noise is applied to the power cables and the signal lines Power cable: 2 kV Digital I/O (24V or higher): 1kV Digital I/O (less than 24 V): 250 V or higher Analog I/O (signal lines): 250 V or higher IEC61000-4-5 Surge immunity Immunity test in which lightening surge is applied to the product
- AC power type Power cable (between cable and ground): ±2 kV Power cable (between cables): ±1 kV Data communication port: ±1 kV
- DC power type Power cable (between cable and ground): ±0.5kV Power cable (between cables): ±0.5kV Data communication port: ±1 kV IEC61000-4-6 Conducted RF immunity Immunity test in which a noise inducted on the power cable and the signal lines is applied Power cable: 10V Data communication port: 10 V IEC61000-4-8 Power supply frequency magnetic field immunity Test for checking normal operations under the circumstance exposed to the ferromagnetic field noise of the power supply frequency (50/60 Hz)
30 A/m
5 - 2 5.2 EMC Directive Requirements
5.2 EMC Directive Requirements
The EMC Directive requires the following.
- Strong electromagnetic waves are not emitted to the outside.: Emission (Electromagnetic interference)
- The product is not affected by the electromagnetic waves from the outside.: Immunity (Electromagnetic sensitivity) To comply with the EMC Directive, this section explains the precautions for configuring equipment integrating the GOT. The data described herein are produced with our best, based on the regulation requirements and standards obtained by Mitsubishi. However, the data do not guarantee that the whole equipment produced according to the data comply with the above directive. The manufacturer of the equipment must determine the method to comply with the EMC Directive and conformance to the directive.
5.2.1 Installing the GOT on the control panel
The GOT is an open type device (designed to be integrated in equipment). Make sure to install the GOT in a control panel. This restriction ensures safety and also has a large effect of suppressing noise generated from the GOT by using the control panel. ■1. Control panel
- The control panel must be conductive.
- When fixing a top or bottom plate of the control panel with bolts, do not coat the plate and bolt surfaces so that they contact each other. Connect the door and the box using a thick grounding cable to ensure the low impedance under high frequency.
- To ensure electric conductivity in the large area as much as possible between an inner plate and the control panel, do not coat the fixing bolt area of the inner plate and the control panel.
- Ground the control panel using a thick grounding cable to ensure the low impedance under high frequency.
- The diameter of cable holes on the control panel must be 10 cm or less. If the diameter of the hole is 10 cm or more, radio waves may leak. To reduce the chance of radio waves leaking out, ensure that the space between the control panel and its door is as small as possible. Pasting the following EMI gasket directly on the painted surface seals the space, reducing the leak of electric waves. Our test has been carried out on a panel having the damping characteristics of 37 dB max. and 30 dB mean (measured by 3m method with 30 to 300 MHz). ■2. Connection of power and ground cables Ground the GOT and connect power supply cables as shown below. (1) Wiring the ground cable Provide a ground point near the GOT. Ground the frame ground terminal (FG terminal) of the GOT with the thickest and shortest cable as possible. (2) Ground cable length The ground cable length must be 30 cm or shorter. The FG terminals pass the noise generated in the PLC system to the ground. Therefore, ensure an impedance as low as possible. Since the ground cables relieve the noise, the cables themselves carry a large noise. Thus, short wiring prevents the cable from acting as an antenna. (A long conductor is an antenna radiating noise more efficiently.) (3) Treatment of the power cable and the ground cable Twist the ground cable led from the ground point with the power cable. Twisting with the ground cable relieves more noise from the power cable to the ground. When a noise filter is installed to the power cable, twisting the power cable and the ground cable may not be required. Manufacturer Series name Contact KITAGAWA INDUSTRIES CO., LTD. RFSG series (Recommended Product) 0587-34-3651
5.2 EMC Directive Requirements 5 - 3
5.2.2 Installing a noise filter (power supply line filter)
A noise filter is a part to effectively reduce conducted noise. Except some models, installation of a noise filter to the power supply lines is not necessary. However, installing the noise filter can reduce conducted noise. The noise filter is effective to reduce conducted noise in the band of 10 MHz or less. Use a noise filter equivalent to the following noise filters (double π-type filters). ■1. Precautions The following shows the precautions for installing a noise filter. (1) Prohibition of bundling cables Do not bundle the input and output cables of the noise filter. Bundling the cables inducts the noise from the output-side cable into the input-side cable where noise has been eliminated by the noise filter. (2) Grounding the noise filter Connect the ground terminal of the noise filter to the control panel with a short cable as much as possible (approximately 10 cm). Model Manufacturer Rated current Rated voltage FN343-3/05 SCHAFFNER 3A 250VFN660-6/06 SCHAFFNER 6A RSHN-2003 TDK 3A Input side (power supply side) Output side (device side) Filter Wire the input and output cables separately. Filter Input side (power supply side) Induction Output side (device side) Bundling the input and output cables inducts noise. Bundling
5 - 4 5.2 EMC Directive Requirements
5.2.3 System configuration
■1. GOT Use the following GOTs having a CE mark on the rating plate. The following models are compliant with the EMC Directive at factory shipment. When any GOT other than the following does not comply with the EMC Directive.■2. Connection type The following table lists the connection types compliant with the EMC Directive. ○: Compliant with EMC Directive, ×: Not compliant with EMC Directive *1 For the details of each connection type, refer to the following manual. ➠ GOT2000 Series Connection Manual (GT Works3 Version1) for the controller used *2 When connecting the GOT to other controllers such as a non- Mitsubishi PLC, fabricate connection cables and configure the system following the EMC Directive specifications. ➠ ■4. Non-Mitsubishi PLC, inverter, and servo amplifier connections POINTPOINTPOINT Connected devices When connecting the GOT to a non-Mitsubishi PLC, refer to the manual about the EMC Directive compliance of the connected device (such as a PLC and a microcomputer).
5.2.4 Connection of power cables and ground cables
Carry out wiring and connect the power and ground cables according to the following instruction. By the different wiring or connection method, the system may not comply with EMC Directive. ■1. Wiring method For connection of power cables and ground cables, refer to the following. Ground the frame ground terminal (FG terminal) of the GOT with the thickest and shortest cable as possible. ➠ 7.2 Wiring Inside and Outside the Panel Product name Model GS2110 GS2110-WTBD GS2107 GS2107-WTBD Connection type*1 GS21 Ethernet connection ○ Direct CPU connection ○ Computer link connection ○ Other connections (Connection with non-Mitsubishi PLC, inverter, servo amplifier) ○*2
5.2 EMC Directive Requirements 5 - 5
5.2.5 Fabricating a connection cable
Fabricate the cables used for the GOT by the methods as shown in this section. The fabrication requires a ferrite core, cable clamp, and cable shielding materials. The following products have passed the Mitsubishi EMC Directive compliance test.
- ZCAT3035-1330 ferrite core (TDK Corporation)
- AD75CK-type cable clamp (Mitsubishi Electric Corporation) ■1. Ethernet connection (1) Ethernet cable Strip off the sheath at both ends of the cable as shown in the figure below to expose braided shield for grounding. The braided shield sections are used for grounding with a cable clamp. ➠ 5.2.6 Grounding a cable
- Connecting to the Ethernet interface of the GOT ■2. Direct CPU connection (1) RS-232 cable and RS-422 cable Install a ferrite core to the cable in the positions as shown in the figure below. ■3. Computer link connection (1) RS-232 cable and RS-422 cable Strip off the sheath at both ends of the cable as shown in the figure below to expose braided shield sections for grounding.The braided shield sections are used for grounding with a cable clamp. ➠ 5.2.6 Grounding a cable Personal computer sideGOT side 230or less 40 40 400or less Unit: mm (inch) Ferrite core (ZCAT3035-1330) 120 or less (4.72) 120 or less (4.72) PLC sideGOT s ide 230 or less 40 40 400 or less Unit: mm (inch) Ferrite core (ZCAT3035-1330) Finishing of wearing 120 or less (4.72) 120 or less (4.72) 100 or less Ferrite core (ZCAT3035-1330) 100 or less (3.94) 230 or less 40 40 230 or less (9.06) (3.94) GOT side PLC CPU side Unit: mm (inch)
5 - 6 5.2 EMC Directive Requirements ■4. Non-Mitsubishi PLC, inverter, and servo amplifier connections Create the cables (RS-232 cable, RS-422/485 cable) for connecting the GOT and a controller by yourself. For how to create a cable, refer to the following. ➠ GOT2000 Series Connection Manual For GT Works3 Version1 POINTPOINTPOINT Treatment of the RS-232 cable and RS-422/485 cable When the GOT is connected to a controller, configure the system according to the EMC Directive specifications for the controller. The following shows the recommended instructions to comply with the EMC Directive. However, the manufacturer of the equipment must determine the method to comply with the EMC Directive and conformance to the directive. (1) RS-422/485 cable
- When connecting each signal wire (except SG and FG wires), twist two signal wires as shown below.
- Connect two or more SG wires. (2) RS-232 cable
- Twist each signal wire (except SG and FG wires) with the SG wire.
- Install a ferrite core to the cable in the positions as shown in the figure below.
- Strip off the sheath at the both ends of the cable as shown in the figure below to expose braided shield for grounding. The braided shield sections are used for grounding with a cable clamp. SDA RDA RDBSDB RDA RDB SDA SDB RD RDSD SD DTR DTR DSR DSR SG SG 100 or less Ferrite core (ZCAT3035-1330) 100 or less (3.94) 230 or less 40 40 230 or less (9.06) (3.94) GOT side PLC CPU side Unit: mm (inch)
5.2 EMC Directive Requirements 5 - 7
5.2.6 Grounding a cable
■1. Grounding method Ground the cable and ground cable to the control panel where the GOT and the PLC are installed. Ground the braided shield section of the cable to the control panel with the cable clamp (AD75CK). To ground a bus connection cable, ground the braided cable for grounding to the control panel by tightening a screw. ■2. Precautions Do not arrange the cable clamp close to the other cables that are not clamped. The noise from the control panel may enter the cable clamp and adversely affect the GOT. Braided shield Cable clamps For the attachment details of cable clamps, refer to AD75CK-type Cable Clamping Instruction Manual <IB-68682>.
5 - 8 5.2 EMC Directive Requirements
6.1 Control Panel Inside Dimensions for Mounting GOT 6 - 1
- INSTALLATION
6.1 Control Panel Inside Di mensions for Mounting GOT
Mount the GOT onto the control panel while considering the following control panel inside dimensions. (If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.) POINTPOINTPOINT Applicable cable Some cables may need to be longer than the specified dimensions when connecting to the GOT. Therefore, consider the connector dimensions and bending radius of the cable as well for installation. MOUNTING PRECAUTIONS WARNING
- Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT main unit to/from the controller. Not doing so can cause the unit to fail or malfunction. MOUNTING PRECAUTIONS CAUTION
- Use the GOT in the environment that satisfies the general specifications described in this manual. Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
- Never drop cutting chips and electric wire chips into the ventilation window of the GOT when you drill screw holes or perform wiring. Otherwise, fire, failure or malfunction may be caused.
- Connect connection cables securely to the specified connectors while the power is turned OFF. Imperfect connection may cause malfunction or failure.
- Operate and store the GOT in environments without direct sunlight, dust, lamp black, conductive dust, corrosive gas, combustible gas, high temperature, condensation, wind, rain, vibrations and impacts. Electric shock, fire, malfunction, product damage or deterioration can be caused.
- Tighten the mounting screws within the specified torque range. Undertightening can cause the GOT to drop, short circuit or malfunction. In addition, undertightening can disable waterproof or oil proof effect. Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT. In addition, the waterproof effect and oilproof effect may not be available due to the "distortion" of GOT or panel. Unit: mm(inch) 30(1.18)
6 - 2 6.2 Panel Cutting Dimensions
6.2 Panel Cutting Dimensions
Cut holes in the following dimensions on the panel. Ensure 10mm of space in upper and lower parts of the panel for mounting fixtures.
- Horizontal format (If the vertical format is selected, the dimension must be rotated 90 degrees.)
6.3 Mounting Position
When mounting the GOT, the following clearances must be maintained from other structures and devices.
- Horizontal format (If the vertical format is selected, the dimension, which is rotated 90 degrees clockwise looking from the display section side, is required.) Installation Environment A, D [mm] (inch) B [mm] (inch) C [mm] (inch) E [mm] (inch) In the presence of radiated-noise or heat-generating equipment nearby 50mm (1.97") or more 80mm (3.14") or more*1 50mm (1.97") or more*2 100mm (3.94") or more In the absence of radiated-noise or heat-generating equipment nearby 20mm (0.79") or more 20mm (0.79") or more 20mm (0.79") or more 20mm (0.79") or more A +2 10 (0.4") or more 10 (0.4") or more Unit: mm (inch) Panel thickness: 1.6 to 4mm (0.06" to 0.15") B +2 GS2110-WTBD A BItem BA CD E 10 (0.4") or more
6.4 Control Panel Temperature and Mounting Angle 6 - 3
6.4 Control Panel Temperature and Mounting Angle
When mounting the main unit to a control panel or similar fixture, set the GOT display section as shown below. ■1. Horizontal installation When the temperature inside the control panel is 40 to 50°C, the mounting angle should be in the range from 60 to 105 degrees. The GOT will have a longer lifetime if used within the mounting angles shown above. Ideally, the temperature inside the control panel should not exceed 0 to 40°C. ■2. Vertical installation When the temperature inside the control panel is 40 to 50°C, the mounting angle should be in the range from 60 to 105 degrees. The GOT will have a longer lifetime if used within the mounting angles shown above. Ideally, the temperature inside the control panel should not exceed 0 to 40°C. GOT back panel GOT display section Control panel, etc. 105° 60° GOT back panel GOT display section Control panel, etc. 105° 60°
6 - 4 6.5 Installation Procedure
6.5 Installation Procedure
The GOT is designed to be embedded into a panel. Mount the GOT by following the procedure below. Refer to "6.2 Panel Cutting Dimensions" for the panel cutting dimensions. In addition, the thickness of the installation panel face must be 1.6 to 4mm. POINTPOINTPOINT Check that the packing is firmly attached with the GOT. If the packing is loose, attach the packing to the GOT securely. Step 1. Inserting into the panel face Insert the GOT from the front side of the panel. Step 2. Fixing the GOT Engage the hook of the mounting fixture (accessory) to the unit fixing hole of the GOT and fix them by tightening the mounting screws (accessory) in the torque range of 0.36 to 0.48N
- m. Step 3. A protection film is attached on the display section of GOT prior to shipment. Remove the film when the installation is completed. Mounting hole Mounting fitting Mounting screw
6.5 Installation Procedure 6 - 5
(1) Tightening the mounting screw Tighten the mounting screw within the specified torque. Under tightening can cause the GOT to drop. In addition, undertightening can disable waterproof or oil proof effect. Failure to do so may damage the unit, or distort the panel and make a surface waviness on the display area, leading to deterioration of the visibility or incorrect input from the touch panel. In addition, undertightening can disable waterproof or oil proof effect.
- Specified torque range: 0.36 to 0.48N (2) Installation panel surface Make sure that the panel surface is free from warpage, flaws and irregularities. Warpage, flaws and irregularities may disable the waterproof effect. Select proper panel thickness under consideration of the panel strength. (For example, the panel strength may be insufficient depending on the panel material and dimensions even if the panel thickness is acceptable. Insufficient panel strength may cause warpage depending on the installation positions of the GOT and other equipment.)
6 - 6 6.5 Installation Procedure
- WIRING This chapter describes the wiring to the GOT power supply section. For the connection with a PLC, refer to the following. ➠ GOT2000 Series Connection Manual For GT Works3 Version1 For the dimensional drawing of connection cables, refer to the following. ➠ Appendix.1 External Dimensions POINTPOINTPOINT General preventive measures against noise There are two kinds of noises: Radiated noise that is transmitted into the air and Conductive noise that is directly transmitted along connected lines. Countermeasures must be taken considering both kinds of noises and referring to the following 3 points. (1) Protecting against noise (a) Keep signal lines away from noise sources such as a power cable or a high-power drive circuit. (b) Shield the signal lines. (2) Reducing generated noise (a) Use a noise filter, etc. to reduce the level of the noise generated due to a source such as a high-power motor drive circuit. (b) Attach surge killers to the terminals on t he no fuse breakers (NFB), electromagnetic contactors, relays, solenoid valves, and generators to suppress noise interference. (3) Releasing noise to the ground (a) Make sure to connect the ground cable to the ground. (b) Use a short and thick cable to lower its ground resistance. (c) Ground the power system and the control system separately. WIRING PRECAUTIONS WARNING
- Be sure to shut off all phases of the external power supply used by the system before wiring. Failure to do so may result in an electric shock, product damage or malfunctions.
- Please make sure to ground FG terminal of the GOT power supply section by applying 100Ω or less which is used exclusively for the GOT. Not doing so may cause an electric shock or malfunction.
- Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product. Not doing so can cause a fire or failure.
- Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
- Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction. WIRING PRECAUTIONS CAUTION
- Plug the communication cable into the connector to be connected, and tighten the mounting screws and the terminal screws in the specified torque range. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
7 - 2 7.1 Power Supply Wiring
7.1 Power Supply Wiring
Connect the power supply to the power terminals on the back panel of the GOT. Use a specified size power supply wire to prevent voltage drop, and tighten the terminal screws firmly to a specified torque. Do not exceed the number of wires that are allowed to be connected. Secure the wires to prevent stress from being directly applied to the terminal block or wire connections.
7.1.1 Cable types and wire end processing
Process the end of the electrical wire (solid or stranded), or attach a ferrules with plastic sleeve to the wire end. Terminal screws should be tightened to between 0.3 to 0.5N·m. Terminal screws must be secured to prevent a loose connection thus avoiding a malfunction. When tightening terminal screws, do not exceed the specified torque. Failure to do so may cause equipment failures or malfunctions. ■1. Electrical wire size ■2. Wire end processing (1) Connecting the wire directly (a) Twist the end of the stranded wire. Make sure there are no wire whiskers. (b) Do not solder the wire end. (2) Using a ferrules with plastic sleeve to connect the wire A wire with a too thick of a wire sheath may not fit the insulation sleeve. Refer to the outline drawing for how to select the proper size wire. ■3. Tools Use a small driver with a straight, untapered blade as shown on the right to tighten the power terminals. Electrical wire size Solid wire Stranded wire Ferrules with plastic sleeve 0.5 to 2.5mm2 AWG20 to AWG14 0.5 to 2.5mm2 AWG20 to AWG14 0.5 to 2.5mm2 AWG20 to AWG14 Manufacturer Model Crimper type Phoenix Contact Inc. AI 0.75-8BU (0.5 to 0.75mm2) CRIMPFOX UD6 AI 1.0-8RD (0.75 to 1.0mm2) AI 1.5-8BK (1.0 to 1.5mm2) AI 2.5-8BU (1.5 to 2.5mm2) Manufacturer Model Phoenix Contact Inc. SZS 0.6 3.5 Approx. 6mm 8 to 12mm 14 to 18mm2.8 to 4.2mm Terminal contact section Insulation sleeve 0.6mm 3.5mm Use a driver with a flat end
7.1 Power Supply Wiring 7 - 3
7.1.2 Wiring example
Connect the power supply to the power terminals on the back panel of the GOT.
7.1.3 GOT's ground
■1. Grounding the GOT and other devices Make sure to carry out the followings for grounding.
- Carry out the independent grounding if possible. Provide class D (class 3) grounding. (Ground resistance must be 100W or less.)
- If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.
- Use the cable of 2mm2 or longer for grounding. Set the grounding point closer to the GOT to make the grounding cable short as possible. Tightening torque for the power terminals 0.5 to 0.6N·m Class D grounding Other deviceGOT Other deviceGOT Other deviceGOT (1) Independent ground (2) Shared grounding (3) Common grounding Grounding (100Ω or less) Grounding (100Ω or less)
7 - 4 7.1 Power Supply Wiring
7.1.4 The cause of malfunctio ns related wiring/Remedy
Grounding of the GOT may cause electric potential difference and noise interference, which may result in GOT malfunctions. These problems may be resolved by taking the following measures. ■1. Wiring path of the GOT's ground cable and power line Bundling the GOT's ground cable and power line together can cause interference noise, which may result in malfunctions. Keeping the GOT's ground cable and power line away from each other will help minimize noise interference. ■2. Connecting the ground cable from the panel that houses control equipment to the panel to which the GOT is grounded When running a single ground cable from the panel that houses such piece of control equipment as a sequencer to the panel to which the GOT is grounded, the ground cable may have to be directly connected to the terminal on the GOT. If electric potential difference between the ground points created by it causes malfunctions, lowering the voltage as shown in Remedy 1 below may solve the problem. FG Power supply for power equipment Power supply for power equipment Good: Wiring the ground cable away from the power cable FG Bad: Bundling the ground cable and the power cable FG Ground cable from the panel that houses control equipment Connection cable
7.1 Power Supply Wiring 7 - 5
- Remedy 1 (Refer to the figures Remedy 1-1 and 1-2 below.) If the electric potential difference between the ground cable and the panel that houses the GOT is creating problems, connect the ground cable to the panel also. If the wiring method as shown in Remedy 1-1 is not feasible, follow Remedy 1-2. If taking Remedy 1 worsens noise interference, taking Remedy 2 may alleviate it.
- Remedy 2 (Refer to the figures Remedy 2-1 and 2-2 below.) Attach a ferrite core to the cable if noise from the GOT panel has adverse effects on the GOT when Remedy 1 is taken. Wind the wire around the ferrite core several times (approx. 3times), if a ferrite core is used. If the wiring method as shown in Remedy 2-1 is not feasible, follow Remedy 2-2. FGGround cable from the panel that houses control equipment Connection cable Panel grounding Panel grounding Remedy1-1 Use the thickest cable possible. FG Connection cable Remedy1-2 Ground cable from the panel that houses control equipment Use the thickest cable possible. Ground cable from the panel that houses control equipment Connection cable Remedy2-1 Use the thickest cable possible. Ground cable from the panel that houses control equipment Use the thickest cable possible. FG Connection cable Remedy2-2 FG Panel grounding Panel grounding Ferrite core Ferrite core
7 - 6 7.2 Wiring Inside and Outside the Panel
7.2 Wiring Inside and Outside the Panel
7.2.1 Wiring inside
Run power lines, servo amplifier drive wires, and communication cables so that they do not cross each other. Noise interference that is generated by cables that cross each other may cause malfunctions. Surge suppressors are an effective way to filter out surge noise that is generated from no fuse breakers (NFB), electromagnetic contactors (MC), relays (RA), solenoid valves, and induction motors. Refer to the section to follow for surge killers. ➠ 7.2.3 Attaching surge killers to control equipment
7.2.2 Outside the panel
To pull the power line and communication cable out of the panel, make two pullout holes away from each other and pull the cables through. Putting both cables through the same pullout hole will increase noise interference. Keep the power line and communication cable inside the duct at least 100mm away from each other. If that is not possible, the use of a metal separator inside the duct can reduce noise interference. NFB MC PLC MC RA RA Terminal block Crossing power lines and communication cables GOT connection cable PLC I/O wire Drive control wire NFB MC PLC MC RA RA Terminal block Uncrossed power lines and communication cables GOT connection cable PLC I/O wire Drive control wire Power cable Power cable Power line Connection cable Pullout hole Pullout hole Connection cablePower line 100mm or more Separator Signal linePower line Power line Wiring duct Signal line
7.2 Wiring Inside and Outside the Panel 7 - 7
7.2.3 Attaching surge kille rs to control equipment
If communication errors happen in synch with the on/off signals from certain control equipment (referred to as "load" hereafter) such as no fuse breakers, electromagnetic contactors, relays, solenoid valves, and induction motors, surge noise interference is suspected. If this problem happens, keep the ground cable and communication cable away from the load. If that is not possible, an installation of a surge killer will help reduce noise interference. Place the surge killer as close to the load as possible. Remedy for AC inductive load Remedy for DC inductive load Output AC C R L: Load Keep the ground cable and communication cable away from each other. Place the surge killer near the load. Output equipment such as PLC output unit Output DC D L: Load Keep the ground cable and communication cable away from each other. Place the surge killer near the load. Output equipment such as PLC output unit
7 - 8 7.2 Wiring Inside and Outside the Panel
8.1 SD Card 8 - 1
- OPTION
8.1 SD Card
The SD card is used to transfer the OS or project data and to save the data of the alarm history function. For details, refer to the following. ➠ 15. CONTROL OF VARIOUS DATA (DATA CONTROL)
8.1.1 Applicable SD card
The following SD cards are applicable for GOT. *1 Some models with the operations checked by our company are usable. For the operation-checked models, refer to "Operation Check Results of Third Party SD Cards on GT14 Model" (Hime-T-P-0089) separately available, or contact your local distributor.
8.1.2 Installation/removal procedure of SD card
Install/remove the SD card when the power supply of the GOT is OFF or [Access inhibit] is set in the [SD card access] setting of the GOT. ■1. Installation Model Specifications L1MEM-2GBSD SD memory card 2GB L1MEM-4GBSD SDHC memory card 4GB - Commercially-available SD card*1 Step 1. Touch [Main Menu] [Data] [SD card access] [Permissions] to set [Access inhibit]. ➠ 15.4 SD Card Access Check that the SD card access LED turns off. When the SD card access LED is off, the SD card can be installed or removed even when the GOT is on. Step 2. Insert a SD card into the SD card interface with its front side (nameplate side) outside. Step 3. Touch [SD card access] [Access inhibit] to set [Permissions]. Check that the SD card access LED turns on. SD card surface
8 - 2 8.1 SD Card ■2. Removal POINTPOINTPOINT Precautions when removing the SD card
- Do not pull out the SD card or power OFF the GOT while the SD card access LED is lit. To do so may cause data corruption or malfunction.
- When removing the SD card from the GOT, make sure to support the SD card by hand as it may pop out. Failure to do so may cause the SD card to drop from the GOT, resulting in a failure or break. Step 1. Touch [Main Menu] [Data] [SD card access] [Permissions] to set [Access inhibit]. ➠ 15.4 SD Card Access Check that the SD card access LED turns off. When the SD card access LED is off, the SD card can be installed or removed even when the GOT is on. Step 2. Push the SD card all the way inside and leave your finger once, then remove the SD card.
9.1 Utility Execution 9 - 1
- UTILITY FUNCTION Utility is a function, which carries out connection of GOT and controller, screen display and operation method settings, program/data control and self-check etc.
9.1 Utility Execution
For utility execution, utility has to be displayed by installing BootOS and package data in the C drive (built in flash memory). There are following two methods for installing BootOS and package data. Refer to the following for the installation which uses GT Designer3. ➠ GT Designer3 (GOT2000) Help For the installation methods of package data with an SD card, refer to the following. ➠ 18. INSTALLING PACKAGE DATA BY USING AN SD CARD Install directly from GT Designer3 Via a USB interface or Ethernet interface GT Designer3 GT Designer3 Writing package data 2) GT Designer3→SD card→GOT GOT GOT Installing package data Installing BootOS or Package data When GOT is remote, install using SD card easily Install SD card to the GOT SD card 1) GT Designer3→GOT
9 - 2 9.2 Utility Function List
9.2 Utility Function List
The items in the following list can be set/operated on the utility screens. Item Functions overview Reference Language Switching message languages ➠ 10. Comm. Setting Standard I/F Assigning channel number and communi cation driver to communication interface ➠ 11.1 GOT IP Address Configuring GOT Ethernet setting ➠ 11.2 Comm. Monitor Checking the serial communication port communication ➠ 11.3 Ethernet check Checking the Ethernet communication port communication ➠ 11.4 Transparent mode Setting the channel No. to be used for the communication for the FA transparent function ➠ 11.5 Keyword Setting or deleting sequence program protection key words and canceling sequence program protection status for the FXCPU connection ➠ 11.6 GOT setup Display Setting the title display period ➠ 12.1Setting the screen save time Adjusting brightness Operation Setting the buzzer sound ➠ 12.2 Setting the window move buzzer Setting the key reaction speed Touch panel calibration Setting the utility call keys Unique info Setting the GOT ID No. ➠ 12.3 Security Setting Security level Changing the security level ➠ 13.1 Operator Operator management ➠ 13.2Password change Function setting Login/Logout ➠ 13.3 Time setting Time setting ➠ 14.1 Data OS information System application informat ion, displaying property, checking data ➠ 15.2 Resource Data Alarm info. Deleting or copying alarm log files Converting alarm log files in G1A format CSV/TXT format ➠ 15.3.1 Recipe info. Converting recipe files in G1P format CSV/TXT format Converting CSV/TXT format Recipe files in G1P format Deleting or copying recipe files ➠ 15.3.2 Logging info. Converting logging files in G1L format CSV/TXT format Deleting or copying logging files ➠ 15.3.3 Image file Deleting or copying hard copy files ➠ 15.3.4 SD card access Setting the access permission of the SD card ➠ 15.4 SD card format Formatting the SD card ➠ 15.5 Clear data Clearing the project data and resource data on the GOT ➠ 15.6 Data copy Transferring the project data or OS to the SD card ➠ 15.7 Debug Device monitor Device monitor of PLC, test function, current value change of the buffer memory and the buffer memory monitor of intelligent module ➠ 16.1 FX list editor Changing parameters and sequence program of FX PLC ➠ 16.2 FX3U-ENET-ADP Configuring the communication se tting for FX3U-ENET-ADP stored in the FXCPU ➠ 16.3 Maintenance Touch panel calibration Displaying the screen for cleaning the display ➠ 17.1 Touch panel check Checking the touch panel operation ➠ 17.2 Clean Displaying the screen for cleaning the display ➠ 17.3
9.3 Utility Display 9 - 3
9.3 Utility Display
To display setting screens for each utility, the main menu has to be displayed first. (1) Main menu The menu items that can be set at the GOT utility are displayed. Touching a menu item in the main menu will display the setting screen or following selection screen for the item. (2) System message switch button This button switches the language used for the utility or system alarms. When touching the [Language] button, the Select Language screen is displayed. Step 1. Touch the language button of a desired language and touch the [OK] button to select the language. Step 2. Touching the [ ] button switches the lan guage on the utility to the selected one.
9 - 4 9.3 Utility Display POINTPOINTPOINT (1) When starting the GOT without selecting any language or the selected language and the installed fonts are not matched The following screen will be displayed. Touching the button of a desired language restarts the GOT and the language is switched to the selected one. (2) Selectable languages The system message switch button is displayed only for the selectable languages. The selectable languages differ depending on the fonts installed in the GOT. For the relation between the selectable languages and the fonts, refer to the following. ➠ GT Designer3 (GOT2000) Help (3) System language switching using the device The system language can be switched using the system language switching device set with GT Designer3. For the setting method of the system language switching device, refer to the following. ➠ GT Designer3 (GOT2000) Help
9.3 Utility Display 9 - 5
9.3.1 Display operation of main menu
The following four types of operation can display the main menu. (Display the main menu after installing the standard monitor OS from GT Designer3 to the GOT built in flash memory.) (1) When project data is undownloaded After the GOT is turned on, a dialog box for notifying of absence of project data is displayed. After the dialog box is displayed, touch the [OK] button to display the main menu. (2) When touching utility call key If you touch the utility call key while user-created screen is displayed, the main menu is displayed. The utility call key is set in the position on the GOT screen upper left corner at factory shipment. *1 The utility function windows appear in the horizont al format, and this format cannot be changed. The utility call key can be set by the GOT utility or GT Designer3. For the setting method of the utility call key, refer to the following. ➠ 12.2.5 Setting the utility call keys ➠ GT Designer3 (GOT2000) Help POINTPOINTPOINT (1) Prohibited simultaneous 2-point presses Do not touch 2 points or more on the GOT screen simultaneously. Touching 2 points or more simultaneously may activate a part other than the touched point. (2) Press time of the utility call key When having set [Press time] of the utility call key setting screen to other than "0 (s)", keep pressing the touch panel for the period set to [Press time] or more before leaving the finger from the touch panel. For utility call key setting, refer to the following. ➠ 12.2.5 Setting the utility call keys (3) When the utility call key is not set Even when the utility call key is not set (set to the zero point), you can display the main menu by performing the following operation.
- Pressing the special function switch set on the user-created screen Turning on the power supply of the GOT Touch [OK] button Horizontal format Vertical format
9 - 6 9.3 Utility Display (3) When touching special function switch (utility) If you touch the special function switch (utility) while user-created screen is displayed, the main menu is displayed. The special function switch (utility) can be set as a touch switch that is displayed on a user-created screen by GT Designer3. For the details of the special function switch, refer to the following. ➠ GT Designer3 (GOT2000) Help POINTPOINTPOINT When limiting the display and operation of the utility When limiting the display and operating users, set a password to the GOT using GT Designer3. If a user tries to display the main menu of the utility, the password is displayed. Refer to the following for the details related to the password setting. ➠ GT Designer3 (GOT2000) Help Special function switch (Utility)
9.3 Utility Display 9 - 7
9.3.2 Utility basic configuration
The basic configuration of utility is as follows. (1) Title display The screen title name is displayed in title display part. (2) Close/Return button When a middle screen of the layers is displayed, if the [ ] (Close/return) butt on in the right corner of screen is touched, returns to the previous screen. If this button is touched when directly displayed from monitor screen, the screen is closed and returns to monitor screen. (3) Scroll button For screens in which the content does not fit on one screen page, there is a right or down scroll button on the screen. Scroll one line/column. Scroll window. Title display Close/Return button Display Title display Title display
9 - 8 9.3 Utility Display
9.3.3 Basic operation of settings change
■1. Change of setting value (1) Setting item, select button Touch the select button to change the settings. The setting methods differ depending on the setting items. The following types of setting method are available. (a) Switching the setting value The button repeats every time it is pressed. (b) Enter the setting value with a keyboard. Use these keys to enter numerical values. Touch the button to display a keyboard on the GOT screen. For the keyboard operations, refer to the next page. (c) Move to another setting screen. Touch the button to move to each setting screen. For the setting method of each setting item, refer to the setting operation of each setting screen. (2) [ ] (Close/Return) button Reflect or cancel the changed settings. (a) [ ] (Close/Return) button Touching this button closes the screen. Depending on the setting item, the GOT restarts. Touch the [ ] button, and then the dialog box shown below is displayed. (If no setting is changed, the dialog is not displayed.) Operate following the message of the dialog box. Description Selection button Description Selection button SHORT LONG OFF
9.3 Utility Display 9 - 9
■2. Keyboard operations Step 1. Touch the numerical value to be changed. Step 2. The keyboard for entering numerical values and a cursor are displayed. The display position of the keyboard differs depending on the position of the touched numerical value. (The keyboard is displayed at a position that does not disturb users to input numerical values.) Step 3. Input numerical value by the keyboard.
- [0] to [9] Key: Enter numerical values.
- [Enter] Key: Completes the numerical value input and closes the keyboard.
- [Cancel] Key: Cancels the numerical value input and closes the keyboard.
- [Del] Key: Deletes one character.
- [AC] Key: Deletes all characters.
- [*] key and the keys which are not mentioned do not function. Step 4. Touching the [Enter] key completes the numerical value input and closes the keyboard. Cursor keyboard
9 - 10 9.3 Utility Display
10.1 Display language setting 10 - 1
LANGUAGE SETTING (LANGUAGE) 10. LANGUAGE SETTING (LANGUAGE)
10.1 Display language setting
10.1.1 Display language setting function
This function allows display language selection. The items which can be set are shown below.
10.1.2 Language setting operation
■1. Language Item Description Setting range Language Display language in which the utility functions and dialog windows are displayed can be selected or confirmed in this menu Japanese/English/Chinese <At factory shipment: Chinese> Step 1. Touch [Language] to bring up the set up screen. Step 2. Select a display language by touching the corresponding button. Step 3. After changing the setting, touch the [ ] button. The setting is saved and the setting screen is closed. Main Menu Touch [Language] Touch a language to be displayed. Touch
10 - 2 10.1 Display language setting POINTPOINTPOINT Switching the display language of the utility by devices Any device can be used for switching the display language of the utility. For details, refer to the following. ➠ GT Designer3 (GOT2000) Help When using devices to switch the display language of the utility, it does not change even if the display language is switched from the GOT utility screen.
11.1 Standard I/F Setting 11 - 1
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) 11. COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) The following communication interfaces can be set.
11.1 Standard I/F Setting
11.1.1 Standard I/F functions
11.1.2 Standard I/F display operation
Item Functions overview Reference Comm. Setting Standard I/F Assigning channel number and communication driver to communication interface ➠ 11.1 GOT IP Address Configuring GOT Ethernet setting ➠ 11.2 Comm. Monitor Checking the serial communication port communication ➠ 11.3 Ethernet check Checking the Ethernet communication port communication ➠ 11.4 Transparent mode Setting the channel No. to be used for the communication for the FA transparent function ➠ 11.5 Keyword Setting or deleting sequence program protection key words and canceling sequence program protection status for the FXCPU connection ➠ 11.6 Function Description Channel no. display Displays the channel number (CH No) that has been assigned by drawing Communication driver display Displays the communicati on driver that has been assigned by drawing software Communication parameters display Displays the communication parameters of the controllers that has been assigned by drawing software Main Menu Comm. Setting Touch [Comm. Setting]. Touch [Standard I/F]. Standard I/F
11 - 2 11.1 Standard I/F Setting
11.1.3 Display content s of standard I/F
Described below are the display items on the standard I/F setting menu and their functions. ■1. Display item (1) Standard interface display BOX The standard interface includes the following four types. Standard I/F-1(RS422): For communication wit h PLC, microcomputer and other equipment Standard I/F-2(RS232): For communica tion with PLC, PC (drawing software), modem, other equipment, bar code reader and transparent Standard I/F-3(USB): For communication with PC (drawing software) and transparent Standard I/F-4(Ethermet): For communication with PC (drawing software) and other equipment (2) Channel No. specification menu BOX Set a channel number to be used by the standard interface. ➠ 11.1.5 Channel setting operation For the detail of the drivers which can be assigned to each channel, refer to this section (3).
- "9" is automatically set to the standard I/F-3(USB). 0: Set when the communication interface is not used. 1, 2: Set when connecting to a controller. 8: Set when connecting to a bar code reader or RFID. 9:*1 Set when connecting to a PC (drawing software). *: Set this channel when the gateway function (except when the connection with controllers is the Ethernet connection) or the Ethernet download function is used. Standard interface display BOX Channel No. specification menu BOX Driver display BOX Drv button Standard I/F-3(USB) Standard I/F-1(RS-422) Standard I/F-4(Ethernet) Standard I/F-2(RS-232)
11.1 Standard I/F Setting 11 - 3
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) (3) Driver display BOX (a) The driver display box displays the names of communication drivers assigned to channels or the communication drivers set in the communication settings of drawing software. For details of the communication drivers to be displayed, refer to the following. ➠ GT Designer3 (GOT2000) Help (b) "Disuse" is displayed in the driver display box in the following cases:
- The communication driver is not installed. ➠ 15.2 System Application Information
- "0" is set in the channel number specification menu box. (c) The channel number of the standard I/F-3(USB) is fixed to "9". (4) button Displays the driver setting screen. Select the driver to use on the driver setting screen. ➠ 11.1.6 Driver setting operation The button is displayed in the following case.
- When a channel number other than channel 0 or 9 is set to the standard I/F-1, standard I/F-2, and standard I/F-4 POINTPOINTPOINT Precautions for communication between GOT and connected devices (1) Installing [Communication driver] and downloading [Communication Settings] To perform communication with the connected device, the following actions are necessary. 1) Installing communication drivers (Up to 2 drivers) 2) Assigning channel numbers and communication drivers to communication interfaces 3) Downloading contents (project data) assigned in step 2) Perform 1), 2) and 3) with drawing software. For details, refer to the following. ➠ GT Designer3 (GOT2000) Help (2) When the communication settings have not been downloaded If the communication settings have not been downloaded with drawing software, set the communication settings on the drawing software or in the GOT utility screen. Drv Drv
11 - 4 11.1 Standard I/F Setting
11.1.4 Detail informa tion setting operation
■1. For Standard I/F-1(RS422) and Standard I/F-2(RS232) Step 1. Touch each driver display box of the standard I/F-1 and standard I/F-2. Step 2. The screen jumps to the detailed information screen and the communication parameter will appear. Step 3. Touch the numerical values of baud rate to switch them repeatedly. The numerical values are set using the ten- key depending on the setting. "0" to "9": Use these keys to enter numerical values. Enter "0" to disable the screen saver function. "ESC": Closes the ten-key window without saving any value entered "AC": Deletes the entire string of numerical characters that are being entered "DEL": Deletes a digit from a string of numerical characters that are being entered "ENT": Enters the value for the clock that has been entered and closes the ten-key pad window "+/-": Switches between positive and negative values (Only positive values are valid for the clock setting.) ".": Invalid key (not used) Touch [Driver display BOX]. Ex. 4800bps 9600bps 19200bps
11.1 Standard I/F Setting 11 - 5
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) POINTPOINTPOINT Communication parameters The types of items that are in the communication parameter setting menu depend on the type of communication driver that is installed on the GOT in use. Refer to the section below for the setting contents of various drivers. ➠ GT Designer3 (GOT2000) Help Step 4. Touch the [ ] button to display the window confirming whether to save the settings. Step 5. Touch the [YES] button to save the settings and restart. Touch the [NO] button to discard the changes.
11 - 6 11.1 Standard I/F Setting ■2. For Standard I/F-4(Ethernet) POINTPOINTPOINT Communication parameter setting by drawing software Set the communication parameter for each communication driver by selecting [Common] [Controller Setting]. ➠ GT Designer3 (GOT2000) Help Step 1. Touch the driver display box of a communication parameter to be set. Step 2. The screen is switched to the communication detail setting. Set the communication parameter on this screen. GOT IP address setting ➠ 11.2 GOT IP Address Setting Step 3. When the [ ] button is touched, it returns to the previous screen. Step 4. Touch the [ ] button to display the window confirming whether to save the settings. Step 5. Touch the [YES] button to save the settings and restart. Touch the [NO] button to discard the changes.
11.1 Standard I/F Setting 11 - 7
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.1.5 Channel setting operation
■1. Channel number setting operation Step 1. Touch the channel No. specification menu box to be set. Step 2. When the channel setting window appears, select the channel number. Step 3. When the channel number is selected, the settings are fixed and the window returns to the previous one. Therefore, touch the [ ] button. Step 4. Touch the [ ] button to display the window confirming whether to save the settings. Step 5. Touch the [YES] button to save the settings and restart. Touch the [NO] button to discard the changes. Touch Touch
11 - 8 11.1 Standard I/F Setting
11.1.6 Driver setting operation
■1. Driver setting operation Step 1. Touch [Drv] button to bring up the driver setting window. Step 2. The available driver names are displayed on the driver setting screen. Select the driver to use. Step 3. When the channel number is selected, the settings are fixed and the window returns to the previous one. Therefore, touch the [ ] button. Step 4. Touch the [ ] button to display the window confirming whether to save the settings. Step 5. Touch the [YES] button to save the settings and restart. Touch the [NO] button to discard the changes. Touch [Drv] Touch
11.2 GOT IP Address Setting 11 - 9
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.2 GOT IP Address Setting
This section describes the GOT Ethernet setting. The GOT Ethernet setting can also be set with drawing software. For details, refer to the following. ➠ GT Designer3 (GOT2000) Help
11.2.1 Standard
The table below shows the communication setting items and setting range. *1 Set the value "0.0.0.0" when not using the subnet mask and default gateway.
11.2.2 Display operation of GOT IP address
Communication setting items Setting range Remark If a value outside the setting range is entered, the error Main Menu Comm. Setting Touch [Comm. Setting]. Touch [GOT IP Address]. GOT IP Address
11 - 10 11.2 GOT IP Address Setting
11.2.3 Setting operation
Step 1. Touch the numerical part of the octet to be changed among the 1st to 4th octets. Step 2. When the ten-key pad appears, enter a numerical value in up to 3 digits, and touch the key. If a numerical value outside the setting range is entered, the following error message appears. Enter a numerical value again. For the details of the setting range, refer to the following. ➠ 16.3.1 Specifications Step 3. The changed IP address is displayed. Touch the [ ] key.Step 4. When the screen shown on the left appears, touch the [YES] key. Touch the numerical part of the octet to be changed. Touch Touch[×] Touch [YES]
11.3 Communication Monitor 11 - 11
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.3 Communication Monitor
11.3.1 Communication monitor functions
11.3.2 Communication monitor display operation
Communication port-selection status display Indicat es the connection status of Standard I/F-1 and I/F-2. Communication status display Displays the co mmunication status (SD: send, RD: receive) Communication error status display Displays an error message when a communication error occurs Comm. Setting Main Menu Comm. Monitor Touch [Comm. Setting]. Touch [Comm. Monitor].
11 - 12 11.3 Communication Monitor
11.3.3 Screen display content
(1) Connection status of the communication ports Indicates the connection status of Standard I/F-1 and I/F-2. Listed in the table below are display items and the connection status (channel number). (2) Communication status Displays the communication status of each communication port. The SD and RD symbols appear in white on red ( , ) while data are being sent or received, and in black on gray ( , ) at other times. They may appear lit depending on the communication status. The SD and RD symbols on the screen indicate normal communication or cable disconnection. Setting example (a) [During normal communication (with connection to a device that supports the transparent mode)] (b) [When the connecting cable with the controller is disconnected] Display item Channel number Remark PLC Ch1 "PLC" appears when connected to a controller (PLC or microcomputer) Barcode Ch8 "BCR" appears when connected to a bar code reader TRANS. Ch9 "TRANS." appears when the controller that is allocated to one of the communication ports supports the transparent mode "TRANS." automatically changes to "PC" when communicating with drawing software Host(PC) Ch9 "PC" appears when the controller that is allocated to one of the communication ports does not support the transparent mode Printer ChA Appears when connected to a printer. Port Channel number Controller type I/F-1 Ch1 MELSEC-FX I/F-2 Ch8, Ch9 - (1) (3) (2) The SD and RD symbols for I/F-1 Only the SD symbol next to I/F-1 blinks.
11.3 Communication Monitor 11 - 13
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) (3) Communication error status Communication error status of each port is displayed on this screen. The following table describes the communication status that each display item shows. Display item Status Action NO ERROR No error Communication is executed normally. ERR Ovr. Overrun error The receive data is sent continuously with a short interval. Let the baud rate (communication speed) be equivalent between the GOT and counterpart equipment. ERR Frm. Framing error The communication frames of GOT and PLC are inconsistent. Confirm the communication settings of GOT and PLC, such as data length, stop bit and baud rate. ERR Prt. Parity error The parity check conditions of GOT and PLC are inconsistent. Let the parity check condition (odd or even) of GOT and PLC be consistent. ERR Text Text error The sum data is inconsistent. Or the contents of the receive data are not consistent with the send command from the GOT. Let the communication settings and contents of data be consistent between the GOT and counterpart equipment. (If NAK is received while the GOT is connected to the microcomputer board, a text error occurs.) TIME OUT Communication timeout Though receiving is started, receive data is not sent. Check the wiring between the GOT and its communication target. (When the GOT is connected to the microcomputer board, confirm the terminator, CR, wiring, etc.) ERR Line Control line error The control line is not operating correctly. Confirm the wiring of the control line. ERR Cmd. Command error A command contained in the receive data is not consistent with the send command from the GOT.
11 - 14 11.4 Ethernet Check
11.4 Ethernet Check
■1. Ethernet check function The Ethernet status check function sends a ping to check the connection status of Ethernet. ■2. Display operation of Ethernet check Ethernet check Main Menu Debug Touch [Debug]. Touch [Ethernet check]. ( 9.2 Utility Function List)
11.4 Ethernet Check 11 - 15
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) ■3. Operation of Ethernet status check Step 1. If the select button of [Destination IP] is touched, a keyboard is displayed. Enter the IP address of the other terminal with the keyboard. <Default: 192.168.3.39> Step 2. If the [Send ping] button is touched, a ping is sent to the IP address entered in [Destination IP]. The timeout time is 5sec.
- When the communication is completed The [Response received.] dialog box is displayed.
- When a communication error occurs The [Timeout occurred.] dialog box is displayed. Touch
11 - 16 11.5 Setting the Transparent Mode
11.5 Setting the Transparent Mode
■1. Function of the transparent mode When using the multi-channel function, the channel No. of a controller to which the FA transparent function is executed can be set. For the multi-channel function and the FA transparent function, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 ■2. Display operation the transparent mode setting ■3. Operation the transparent mode Function Description Setting range ChNo. The channel No. of a controller to which t he FA transparent function is executed can be set. 1/2 (Default: 1) Step 1. When the transparent ChNo. (numerical part) on the left is touched, the screen for selecting a communication driver is displayed. Select the channel to execute the FA transparent function. Step 2. If the [ ] button is touched, it returns to the GOT setup screen. Transparent mode Main Menu Comm. Setting Touch [Comm Setting] Touch [Transparent mode] ( 9.2 Utility Function List)
11.6 Keyword 11 - 17
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.6 Keyword
11.6.1 Keyword functions
The operation related to a keyword of the FX series PLC can be performed.
11.6.2 Keyword display operation
Regist Keyword is registered. Delete Registered keyword is deleted. Clear Keyword protection is cleared. Protect A keyword with cleared protec tion is reactivated for protection. Main Menu Comm. Setting Channel Setting Keyword Touch [Comm. Setting] Touch [Keyword]
11 - 18 11.6 Keyword
11.6.3 Regist
Keyword is registered. Step 1. Touch "Regist" to display the selection screen for the registration. For the FX series PLC, which is not compatible with Customer Keyword, the keyword entry screen of [Step3] is displayed. Start the operation from [Step3]. For the Customer Keyword compatible models, refer to the manual of the PLC to be used. Step 2. Select [Keyword] or [Keyword+Custom]. To register only Keyword and 2nd keyword, touch [Keyword]. To register Customer Keyword, touch [Keyword+Custom]. Step 3. Input a keyword. Touch the display part of the keyword to be registered. Step 4. The keyboard for entering a keyword is displayed. Character types to be input can be changed by touching the [KEY] button. Enter a keyword and touch the [ENT] key. For the keyword, 8 digits from 0 to 9 or A to F must be set. Touch Touch Touch
11.6 Keyword 11 - 19
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING) Step 5. After completing the keyword entry, touch [Next]. When [Keyword+Custom] is selected on the selection screen for the registration, the Customer Keyword entry screen is displayed. Enter it in the same way as for Keyword and 2nd keyword. Step 6. Set Registration conciliation. Touch Registration conciliation to change the setting contents. Step 7. After setting Registration conciliation, touch the [Execute] key. The registration of the keyword is completed. Step 8. The registration of the keyword is completed. Touch [OK]. Touch Touch All Protect Write Protect R/W Protect Touch Touch
11 - 20 11.6 Keyword POINTPOINTPOINT (1) Selection availability of Registration conciliation The following table lists the PLCs that can select Registration conciliation. *1 Refer to the manual for the PLC in use for the models that are compatible with the 2nd keyword. *2 Registration options can be selected among "R/W Pr otect", "Write Protect", or "All online operation protection". For access restrictions of each setting, refer to the manual of the PLC to be used. (2) Selection of keyword protection level For the devices which can perform the online operation of FX PLC, 3 levels of protection can be set. When the monitoring or setting change by online devices is needed, set the keyword taking the following into consideration. (a) When only keyword is registered Protection level is selected by the head character of keyword. All Protect: Set the keyword starting with one of A, D to F, or 0 to 9. Read/incorrect write protection: Set the keyword starting with B. Erroneous write prohibition: Set the keyword starting with C. (b) When keyword and 2nd keyword are registered (3) Applicability of monitoring for each keyword protection level The applicability of monitoring for each protection level is as follows. *1 When the T, C set values are specified indirectly, changing devices is available. (4) Difference between "All online operation protection" and "All Protect" When "All online operation protection" is selected, both device display and input by the programming tool or GOT are prohibited. When "All Protect" is selected, device display and input are possible although operations by the programming tool are all prohibited. Target PLC Setting When keyword and 2nd keyword are registered When only keyword is registered FX PLC compatible with 2nd keyword*1 Registration options*2 can be selected. Registration options*2 cannot be selected.FX PLC not compatible with 2nd keyword*1 - Item When only keyword is registered When keyword and 2nd keyword are registered Keyword unregistered/ protection canceled All operation protect Read/ Incorrect write protection Erroneous write prohibition All online operation protection R/W Protect Write Protect Device monitoring Device change T, C setting values and file register (from D1000) *1 *1 *1 Other than the above
11.6 Keyword 11 - 21
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.6.4 Delete
Registered keyword is deleted. Step 1. Touch [Delete] to display the keyword entry screen. Step 2. Input a keyword. Touch the display part of the registered keyword. Step 3. The keyboard for entering a keyword is displayed. Enter a keyword and touch the [ENT] key. Character types to be input can be changed by touching the [KEY] button. Step 4. After completing the keyword entry, touch [Next]. Touch Touch Target PLC Setting FX PLC compatible with 2nd keyword Input a keyword to be deleted. FX PLC not compatible with 2nd keyword Input a keyword to be deleted only into "keyword". "2nd keyword" is ignored. Touch Touch
11 - 22 11.6 Keyword Step 5. Touch the [Execute] key. Step 6. The keyword is deleted. Touch [OK]. Touch Touch
11.6 Keyword 11 - 23
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.6.5 Clear
To access an FX PLC where a keyword has been registered, keyword protection is cleared. Step 1. Touch [Clear] to display the keyword entry screen. Step 2. Input a keyword. Touch the display part of the registered keyword. Step 3. The keyboard for entering a keyword is displayed. Enter a keyword and touch the [ENT] key. Character types to be input can be changed by touching the [KEY] button. Step 4. After completing the keyword entry, touch [Next]. Touch Touch Target PLC Setting FX PLC compatible with customer keyword Input a keyword or customer keyword to clear the protection. FX PLC compatible with 2nd keyword Input a keyword to clear the protection. FX PLC not compatible with 2nd keyword Input a keyword into "keyword" to clear the protection. "2nd keyword" is ignored. Touch Touch
11 - 24 11.6 Keyword Step 5. Touch the [Execute] key. Step 6. The protection is cleared. Touch [OK]. Touch Touch
11.6 Keyword 11 - 25
COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
11.6.6 Protect
A keyword with cleared protection is reactivated for protection. Keyword protection function is valid when the 2nd keyword is registered. Step 1. Touch [Protect] to switch to the keyword protection status. Step 2. The keyword is protected. Touch [OK]. Touch
11 - 26 11.6 Keyword
12.1 Display Settings 12 - 1
DISPLAY AND OPERATION SETTINGS (GOT SET UP) 12. DISPLAY AND OPERATION SETTINGS (GOT SET UP) The setting screens related to the display or operation can be displayed from the utility screen. In the setting screen for display and the setting screen for operation, the following settings can be set.
12.1 Display Settings
12.1.1 Display setting functions
Setting regarding display is possible. The items which can be set are described below. If touch the each item part, the respective setting becomes possible. *1 Even if 0 is set, the title screen is still displayed. The title screen is always displayed for 4 seconds or more (depending on the project data). POINTPOINTPOINT (1) Display setting by GT Designer3 Set title display period, screen save time and screen save backlight by selecting [Common] [GOT Environmental Setting] [GOT Setup] on GT Designer3. When change a part of the setting, change the setting by the GOT display setting after downloading the project data. ➠ GT Designer3 (GOT2000) Help (2) Screen save time By using the system information function, the screen save function can forcibly enabled from a controller (Forced Screen Saver Disable Signal) or the screen saving time set in the utility can be disabled (Automatic Screen Saver Disable Signal). ➠ GT Designer3 (GOT2000) Help Item Description Reference Display settings Setting the title display period and screen saving time ➠ 12.1.1 Brightness Operation settings Setting buzzer volume, window move buzzer, and key reaction speed ➠ 12.2.3 Touch panel calibration ➠ 12.2.4 Utility call key ➠ 12.2.5 Item Description Setting range Opening time The title display period at the main unit boot can be set. 0 to 60 seconds*2 (At factory shipment: 5 seconds) Screen save time The period from the user stops the touch panel operation till the screen save function starts can be set. 0 to 60 minutes (At factory shipment: 0 minute) Brightness Brightness can be adjusted. ➠ ■■2. Brightness
12 - 2 12.1 Display Settings
12.1.2 Display operation of display setting
[GOT setup]. Touch [Display]. ( 9.2 Utility Function List)
12.1 Display Settings 12 - 3
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.1.3 Display setting operations
■1. The title display period and screen saving time Step 1. If the setting items (numbers) are touched, a keyboard is displayed. Input numeric with the keyboard.Step 2. Set the title display period with the ten- key pad window and touch "ENT". Touch
12 - 4 12.1 Display Settings ■2. Brightness Step 1. Touch [Brightness] to bring up the Brightness setting window. Step 2. Touch the [+] and [-] buttons to adjust the brightness of the screen. Step 3. Touch the [ ] button to reflect the setting. Adjust brightness with the [−] and [+] buttons. Touch
12.2 Operation Setting (Settings for Operation) 12 - 5
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.2 Operation Setting (S ettings for Operation)
12.2.1 Operation setting functions
Setting regarding GOT operation can be set. The items which can be set are described below. If touch the each item part, the respective setting becomes possible. *1 The more the value set for [Key reaction] is high, the more the key reaction speed slows. For example, when the GOT recognizes touching the GOT screen once as touching the screen twice, set a higher value for [Key reaction]. POINTPOINTPOINT Operation setting by GT Designer3 Set buzzer volume and window move buzzer volume by selecting [Common] [GOT Environmental Setting] [GOT Setup] of GT Designer3. When change a part of the setting, change the setting by the GOT display setting after downloading the project data. ➠ GT Designer3 (GOT2000) Help Function Description Setting range Buzzer volume Buzzer volume setting can be changed. OFF/SHORT/LONG (At factory shipment: SHORT) Window move buzzer Whether turn ON/OFF buzzer when move window can be selected. ON/OFF (At factory shipment: ON) Key reaction The touch panel sensitivity when touching the GOT screen can be set. (For preventing chattering) ±0 to +120 Calibration Calibrates the touch panel sensitivity ➠ 12.2.4 Position correction of the touch panel (touch panel calibration setting) Utility call Utility call key setting screen can be displayed ➠ 12.2.5 Setting the utility call keys "Key reaction" [ms] Standard ( ±0) +10 +20 +40 +80 +120
12 - 6 12.2 Operation Setting (Settings for Operation)
12.2.2 Display operation of operation setting
to be changed. Main Menu GOT setup Operation Touch [GOT setup]. Touch [Operation]. ( 9.2 Utility Function List)
12.2 Operation Setting (Settings for Operation) 12 - 7
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.2.3 Setting operation of operation
■1. Buzzer volume ■2. Window move buzzer Step 1. Touch a setting item to change the setting. Step 2. Touch the [ ] button to save the changes. Step 1. Touch a setting item to change the setting. Step 2. Touch the [ ] button to save the changes. (Buzzer volume: )SHORT LONG OFF (Window move buzzer: )ON OFF
12 - 8 12.2 Operation Setting (Settings for Operation) ■3. Key reaction setting *1 The more the value set for [Key reaction] is high, the more the key reaction speed slows. For example, when the GOT recognizes touching the GOT screen once as touching the screen twice, set a higher value for [Key reaction]. Step 1. If touch the setup item, the setup contents *1 are changed. Step 2. After changing the setting, touch the [ ] button. The setting is saved and the setting screen is closed. "Key reaction" [ms] Standard (±0) +10 +20 +40 +80 +120
12.2 Operation Setting (Settings for Operation) 12 - 9
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.2.4 Position correction of the touch panel (touch panel calibration setting)
■1. Touch panel calibration setting function Touch panel reading error can be corrected. Normally the adjustment is not required, however, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, correct the position with this function. ■2. Touch panel calibration setting display operation Run Stop Run Stop Before adjustment After adjustment The [Run] will operate though you intended to touch the [Stop] button. The [Stop] button can be touched without fail. Main menu GOT setup OperationCalibration Touch [GOT setup]. Touch [Operation]. Touch [Calibration].
12 - 10 12.2 Operation Setting (Settings for Operation) ■3. Touch panel calibration operation Touch [+] displayed on the screen with the finger one by one to make the setting. Step 1. Touch the center of [+] displayed on the upper left precisely. Step 2. Touch [+] displayed on the lower left. Step 3. Touch [+] displayed on the upper right. Step 4. Touch [+] displayed on the lower right. Step 5. When the precise touch could not be made, touch the [YES] button to make the setting from Step1 again.
12.2 Operation Setting (Settings for Operation) 12 - 11
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.2.5 Setting the utility call keys
■1. Utility call key setting function The key position for calling the main menu of the utility can be specified. For the key position, the specification of 1 point from 4 corners on the screen, or no specification (0 point), can be set. By keeping pressing the screen, a setting to switch the screen to the utility is available. This prevents a switching to the utility by an unintentional operation. POINTPOINTPOINT Operation setting by GT Designer3 Set the utility call key by selecting [Common] [GOT Environmental Setting] [GOT Setup] from GT Designer3. When change a part of the setting, change the setting by the GOT display setting after downloading the project data. ➠ GT Designer3 (GOT2000) Help ■2. Utility call key display operation Main menu GOT setup OperationUtility call Touch [GOT setup]. Touch [Operation]. Touch [Utility call]. Touch bottoms to set for the Utility call key. ( 9.2 Utility Function List)
12 - 12 12.2 Operation Setting (Settings for Operation) ■3. Utility call key setting operation POINTPOINTPOINT (1) When the utility call key is not set (set to 0-point) Even when the utility call key is not set (set to the zero point), you can display the main menu by performing the following operation.
- Pressing the special function switch set on the user-created screen ➠ 9.3.1 Display operation of main menu (2) Precautions on using the alarm popup display When [Display Position Switching] is set to [Yes] in the alarm popup display setting, set either of the following for the utility call key. Setting the position of the utility call key to the upper-right or lower-left corner Setting [Press Time] of the utility call key to 1 or more seconds When [Press Time] is set to 0 and the key position is set to the lower-left corner, the operation is as described below. If the positions of the key and the alarm popup display overlap, the utility screen appears by switching the display position of the alarm popup display. For the alarm popup display, refer to the following. ➠ GT Designer3 (GOT2000) Help (3) When limiting the display and operation of the utility When limiting the display and operating users, set a password to the GOT using GT Designer3. If a user tries to display the main menu of the utility, the password is displayed. Refer to the following for the details related to the password setting. ➠ GT Designer3 (GOT2000) Help Step 1. Touch or displayed at the four corners of the setting screen. The button repeats every time it is pressed. Change the part to be set as a key position to . For the key position, 0 or 1 point can be specified. Step 2. When setting 1 point, specify the time to switch to the utility in case of keeping pressing the key position. Touch the time input area. Step 3. Touching the input area displays a keyboard. Input numeric with the keyboard. Step 4. Touch the [ ] button to save the changes.
12.3 Inherent Information 12 - 13
DISPLAY AND OPERATION SETTINGS (GOT SET UP)
12.3 Inherent Information
12.3.1 Setting function for inherent information
Configure inherent information settings.
12.3.2 Display operation of inherent information
12.3.3 Setting operation for inherent information
Item Description Setting range GOT ID No. Set the ID No. as the inherent information for the GOT. 0 to 32767 <Default: 0> Step 1. If touching the setting items, keyboard is displayed. Input numeric with the keyboard. Step 2. If touch the [ ] button, the GOT restarts and operates with the changed settings. Main menu GOT setup Unique info Touch [GOT setup]. Touch [Unique info].
12 - 14 12.3 Inherent Information
13.1 Security Level Authentication 13 - 1
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) 13. SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING)
13.1 Security Level Authentication
■1. Security level change functions Changes the security level to the same security level set by each object or screen switch. To change the security level, enter the password for the security level set with GT Designer3. ➠ GT Designer3 (GOT2000) Help POINTPOINTPOINT Restrictions on screen display The security level change screen cannot be displayed when project data do not exist in GOT. Change the security level after downloading the project data to GOT. ■2. Display operation of security level change the password of the changed security level is input. Main Menu Security setting Security levelSecurity Level Change Touch [GOT setup]. Touch [Operator]. Touch [Level Change].
13 - 2 13.1 Security Level Authentication ■3. Security level change operation (1) Input operation of password POINTPOINTPOINT About forgetting to return to the original level after changing security level temporarily When use GOT after temporarily changing the security level, do not forget to return the security level to the original level. Step 1. By touching [0] to [9], [A] to [F] key, the password of the changed security level is input. Character types to be input can be changed by touching the [KEY] button. Step 2. When correcting the input character, touch [Del] key to delete the correcting character and input the password again. Step 3. After inputting password, touch the [Enter] key. When the password is not matched, displays the error message. Step 4. If [OK] button is touched it returns to the password input screen again. Step 5. If the [ ] button is touched, it returns to the security setting screen.
13.2 Operator Authentication 13 - 3
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING)
13.2 Operator Authentication
13.2.1 Operator information management
■1. Operator management (1) Operator management function The function enables displaying a list of the operator information and adding, changing, or deleting the operator information to be used. A password for operator authentication can be changed when the password is out of date. Functions for the operator authentication (automatic logout time, authentication method, password expiration date, etc.) can be set. For details of the operator authentication functions, refer to the following. ➠ GT Designer3 (GOT2000) Help (2) Display operation of operator management Function Description Reference page Operator info. Enables adding, editing, deleting, importing, and exporting the operator information. ➠ 13-3, 13-6 Add Add operator information to the GOT. ➠ 13-6 Edit Edit the operator information stored in the GOT. ➠ 13-9 Delete Delete the operator information stored in the GOT. ➠ 13-10 Restore Restore the current operator information to the previous saved one. ➠ 13-11 Import Import the operator information that is already exported to an SD card to the GOT. ➠ 13-11 Export Export the operator information stored in the GOT to an SD card. ➠ 13-12 Password change Enables changing passwords to be used for login and logout in/out of the GOT. ➠ 13-13 Function Enables setting the automatic l ogout time and password expiration date. ➠ 13-15 Operator info. Main Menu Security setting Operator info. Touch [Security setting]. Touch [Operator]. Touch [Operator info.]. ( 9.2 Utility Function List)
13 - 4 13.2 Operator Authentication (3) Display example of operator management (a) Operator information management screen No. Item Description (a) Operator Name Displays operator names. (b) ID Displays operator IDs. (c) Level Displays security levels for operators. (d) Update Displays the last updated dates of the operator information. (e) Operation keys Execution keys for each function (f) Drive in use Displays and sets the storage location for imported and exported operator information. To switch the drive, touch the key. (A: Standard SD card) Only when the drive E is installed on the GOT, the user can switch the drive in use. (a) (b) (e) (f) (c) (d)
13.2 Operator Authentication 13 - 5
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) (b) Operator information edit screen Touch the [Add] button or touch the [Edit] button with the operator information selected on the Operator information management screen, and then the Operator information edit screen is displayed. The operator information can be edited. No. Item Description (a) Operator Name The operator name to be edited is displayed or input an operator name to be added. (Up to 16 alphanumeric characters) (b) Operator ID The operator ID to be edited is displayed or input an operator name to be added. (Setting range: 1 to 32766, Maximum number of registrations: 255) (c) Level Displays the security level for the operator or input the security level for an operator to be added. (0 to 15) (d) Password Input a password. (Up to 16 alphanumeric characters) (e) Expiration Switches the setting of the item disabled and enabled. (e) (d) (a) (c) (b)
13 - 6 13.2 Operator Authentication (4) Operator management operation Step 1. Touch [Operator] [Operator info.]. Step 2. The Admin password authentication screen is displayed, and then input the administrator password. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [Enter] key. Step 3. When the administrator password is correctly input, the Operator information management screen in displayed. For operation of operating switches, refer to the following. [Add] ➠This section (4) (a) [Edit] ➠This section (4) (b) [Delete] ➠This section (4) (c) [Import] ➠This section (4) (d) [Export] ➠This section (4) (e) Step 4. Touching the [ ] button displayed on the upper right returns to the previous screen.
13.2 Operator Authentication 13 - 7
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) (a) Add operation Add operator information to the GOT. Step 1. Touch the [Add] button. Step 2. The Operator information edit screen is displayed, and then touch an item to be edited. (a) OperatorName (b) OperatorID (c) Level (d) Password (e) Expiration (a) If the operator name is touched, a keyboard is displayed. Input an operator name with the keyboard. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [ENT] key. (b) If the operator ID is touched, a keyboard is displayed. Input an operator ID. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [ENT] key. (c) If the level is touched, a keyboard is displayed. Input an operator level. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [ENT] key. When the level of the operator being login is changed during editing the operator information, a new level is not reflected until you log out of the GOT once and log in the GOT again.
13 - 8 13.2 Operator Authentication (d) For changing passwords during editing, touch the password. A keyboard is displayed, and then input a password. When the input is completed, touch the [ENT] key. When the password input is completed, the New password input confirmation dialog box is displayed. Input the same password. (e) For switching the setting of [Make a permanent password], touch the [Expiration] dialog box to switch the setting. [Terminable] [Permanent] Step 3. When the [Save] button is touched after all items are input, the input operator information is saved. Touching the [ ] button displayed on the upper right returns to the previous screen.
13.2 Operator Authentication 13 - 9
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) (b) Edit operation Edit the operator information stored in the GOT. Step 1. Select the operator information to be edited with touching the operator information. Step 2. Touch the [Edit] button. Step 3. The Operator information edit screen is displayed, and then touch an item to be edited. (a) Level (b) Password (c) Expiration For how to edit operator information, refer to the following. ➠This section (4) Step 4. When the [Save] button is touched after all items are input, the input operator information is saved. Touching the [ ] button displayed on the upper right returns to the previous screen.
13 - 10 13.2 Operator Authentication (c) Deletion operation Delete the operator information stored in the GOT. Step 1. Select the operator information to be deleted with touching the operator information.Step 2. Touching the [Delete] button deletes the selected operator information. Touching the [ ] button displayed on the upper right returns to the previous screen.
13.2 Operator Authentication 13 - 11
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING) (d) Import operation Import the operator information that is already exported to an SD card to the GOT. Step 1. Touch the [Import] button. Step 2. The dialog box shown left is displayed. When the [YES] button is touched, the Admin password authentication screen is displayed. Input the administrator password. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [Enter] key. Step 3. When the administrator password is correctly input, the dialog box shown left is displayed and the operator information stored in an SD card is imported to the GOT.
13 - 12 13.2 Operator Authentication (e) Export operation Export the operator information stored in the GOT to an SD card. Step 1. Touch the [Export] button. Step 2. The dialog box shown left is displayed. Step 3. Touch the following buttons according to the output format for the file. Binary file: [BINARY] button CSV file: [CSV] button Step 4. The dialog box shown left is displayed. When the [YES] button is touched, the Admin password authentication screen is displayed. Input the administrator password. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [Enter] key. Step 5. When the administrator password is correctly input, the dialog box shown left is displayed and the operator information stored in the GOT is exported to an SD card. (file name: AUTHINF.G2U)
13.2 Operator Authentication 13 - 13
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING)
13.2.2 Password change
(1) Password change function The passwords to be used for the operator authentication can be changed. For the password change, log into the GOT in advance with the operator name corresponding to the password to be changed. (2) Display operation of password change Password change Main Menu Security setting Operator Touch [Security setting]. Touch [Operator]. Touch [Password change]. ( 9.2 Utility Function List)
13 - 14 13.2 Operator Authentication (3) Password change operation Step 1. Touch [Security setting] [Login/ Logout] to log into the GOT with the operator ID whose password is to be changed. Step 2. Touch [Password change] in the operator setting menu, and then the Password change dialog box is displayed. Step 3. Input the current password on the Password change dialog box. Character types to be input can be changed by touching the [KEY] button. When the input is completed, touch the [Enter] key. Step 4. Input a new password. Step 5. After inputting a new password, input the new password again. Step 6. When the new password is correctly input, the dialog box shown left is displayed and the password is changed.
13.2 Operator Authentication 13 - 15
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING)
13.2.3 Function setting
(1) Function setting function The functions for the operator information can be set. The following items can be set. (2) Display operation of function setting Item Description Reference page Auth method The authentication method is fixed to the password authentication. ➠ 13-17 Auto logout time The time from when the last time the GOT is operated until when you automatically log out of the GOT can be set. (1 to 60 minutes, 0 is invalid.) ➠ 13-16 Expiration date Set the item for regularly changing the password to be used for the operator authentication. (1 to 1000 days, 0 is invalid.) When the password is out of date after setting the password, the GOT requests the password change. ➠ 13-16 Function Main Menu Security setting Operator Touch [Security setting]. Touch [Operator]. Touch [Function]. ( 9.2 Utility Function List)
13 - 16 13.2 Operator Authentication (3) Function setting operation Step 1. Touch [Operator] [Function], and then the Admin password authentication dialog box is displayed. Step 2. When the administrator password is correctly input, the Function setting screen in displayed. Touch an item to be set. (a) Auto logout time (b) Expiration date (a) Touch [Auto logout time], and then the Auto logout time edit dialog box is displayed. Input the time. When the input is completed, touch the [ENT] key. (b) Valid byte count Set the valid byte count for external authentication ID. (Only available when [External auth] is set as the authentication method.) Step 3. Touching the [ ] button displayed on the upper right returns to the previous screen.
13.3 Login/Logout 13 - 17
SECURITY LEVEL AND OPERATOR SETTINGS (SECURITY SETTING)
13.3 Login/Logout
To manage the operator or change the password, log into the GOT. ■1. Display operation of login/logout ■2. Operation of login/logout (1) Login (2) Logout Step 1. Log into the GOT by inputting an operator name and its password. Step 1. Touch [Security setting] [Login/ Logout], and then the screen shown left is displayed. Touch the [YES] button. Main Menu Security setting Login/Logout Touch [Security setting]. Touch [Login/Logout].
13 - 18 13.3 Login/Logout
14.1 Time Setting and Display 14 - 1
CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING AND DISPLAY) 14. CLOCK SETTINGS AND BATTERY STATUS DISPLAY (TIME SETTING AND DISPLAY) The clock data (date and time) are displayed and set in the clock setting menu.
14.1 Time Setting and Display
14.1.1 Time setting a nd display functions
Time settings and displaying of the status of GOT built-in battery are possible.
14.1.2 Clock display and setting operation
Time setting Carry out the display and setup of PLC CPU clock data. Main Menu Time setting Touch [Time setting].
14 - 2 14.1 Time Setting and Display
14.1.3 Clock setting operations
■1. Clock display Displays and sets up the clock data on the GOT. When setting the clock data, change the clock data on the GOT and controller unless the clock setting is "Disuse". If you fail to change the clock data on the controller, the clock data on the GOT is not changed as well. When the GOT is not connected to the controller or is connected the controller which does not have the clock data, set the clock setting to "Disuse" first, and then change the clock data. The setup methods of clock data are shown below.? Step 1. Touch either the date or time to be changed. Step 2. Enter date or time on the ten-key pad. The day of the week is displayed automatically according to the input date. "0" to "9": Use these keys to enter numerical values "ESC": Closes the ten-key window without saving any value entered for the date or time "AC": Deletes the entire string of numerical characters that are being entered "DEL": Deletes a digit from a string of numerical characters that are being entered "ENT": Enters the value for the date or clock that has been entered and closes the ten-key pad window "+/-": Switches between positive and negative values. (Only positive values are valid for the date or clock setting.) ".": Invalid key (not used) Step 3. Set [Time setting]. Touch a setting item to change the setting. [Use] [Disuse] Use: Acquires the time information from an external device. Disuse: Does not acquire the time information from an external device. Step 4. After changing the settings, touch the [ ] button to save the changes and close the setting window. Touch the item to be changed. Touch the item to be changed.
15.1 Data Storage Location 15 - 1
CONTROL OF VARIOUS DATA (DATA CONTROL) 15. CONTROL OF VARIOUS DATA (DATA CONTROL) A system application, project data (screen data), or alarm data which is written in the GOT or SD card can be displayed, and the data can be transferred between the GOT and SD card. The format of the SD card is also possible.
15.1 Data Storage Location
15.1.1 Data type and storage location
■1. System The data storage location and transferring (write/read) route for each data type are shown below. Also, the data storage locations are shown below. The data of the build in flash memory (Project data, etc.) can be saved even if the battery voltage becomes low. *1 The SD card can be used from Utility. ➠ 15.2 System Application Information *2 When using the project data stored in the Standard SD Card (A drive) with the GOT, hold the SD card installed to the GOT. Item Data type Storage location BootOS Built in flash memory (C drive) Basic system application Standard SD card (A drive) Built in flash memory (C drive)*2Communication driver Advanced system application *1 Project data (Including recipe setting, alarm conditions, time action, and GOT setup.) Standard SD card (A drive) Built in flash memory (C drive)*2 Read Upload Write Write Install/ Download PC GT Designer3 A drive (Built-in SD card) SD card (when installed in GOT) Inserting/ Removing SD card (when installed in PC) C drive (Built-in flash memory) Copy files on Windows System application BootOS Project data Install, Write : Upload, Read : BootOS System application Project data BootOS System application Project data Project dataProject data Project data BootOS BootOS System application Project data
15 - 2 15.1 Data Storage Location ■2. At maintenance POINTPOINTPOINT Checking available space of the storage memory To save resource data, check available space of the storage memory. Item Data type Storage location Alarm data (Advanced alarm log file, alarm log file) Standard SD card (A drive) C drive (Built-in flash memory) Recipe data (Advanced recipe file, Recipe file) Logging (Logging file) Image file (Hard copy function) Read Copy Copy PC GT Designer3 A drive (Standard SD card) SD card (when installed in GOT) Inserting/ Removing SD card (when installed in PC) C drive (Built-in flash memory) Copy files on Windows Install, Write : Upload, Read : Alarm Recipe Logging Hard copy Alarm Hard copy Alarm Hard copy Alarm Recipe Logging Hard copy Alarm Recipe Logging Hard copy
15.1 Data Storage Location 15 - 3
CONTROL OF VARIOUS DATA (DATA CONTROL)
15.1.2 Checking version of basic system application
Confirm the basic system application version carefully when installing the BootOS and basic system application. When the basic system application is installed, the GOT checks and compares the basic system application version automatically. (1) When install BootOS When the BootOS to be installed has the older major version, GOT displays the installation disapproving message to cancel the installation so that the older version may not be written. (Even when the version of the BootOS to be installed has the same or later version, the version information and the dialog box for selecting continue/not continue will be displayed.) (2) When install basic system application or communication driver When a basic system application or communication driver has already been installed, the version information of the basic system application which has been installed and the dialog box for selecting whether to continue the installation or not will be displayed. Moreover, when the different versions will coexist among all applications (basic system application and communication driver) by installing the basic system application, the installation disapproving dialog box will be displayed and the installation process is canceled. (3) When download project data The GOT automatically compares the version between the project data to be downloaded and the installed basic system application. When the versions are different, the dialog box confirming whether to install the basic system application together is displayed. When downloading the project data from an SD card, storing the project data and basic system application beforehand is recommended. The version of each system application installed in the GOT can be checked by displaying the property of the system application information screen. For the display operation of the screen, refer to the following. ➠ 15.2 System Application Information POINTPOINTPOINT Version confirmation of BootOS by rating plate Confirm the version of BootOS installed in the GOT at product shipment by rating plate of GOT rear face. Explanation of OS version 01.00.00.B BootOS version (Appears only when the property of the BootOS is displayed.) Minor version Major version MODEL GRAPHIC OPERATION TERMINAL GS2107-WTBD PASSED IN 24VDC MAX 6.50W 002692412C1C 83013913AA00029-A Hardware Version Boot OS version AA 2013-09 POWER MAC ADD. SERIAL DATE
15 - 4 15.2 System Application Information
15.2 System Application Information
■1. Function of system application information Each file name or folder name of BootOS and package data stored in each drive (A: Standard SD card or C: Built-in flash memory) can be displayed in a list. Also, each file can be installed and updated. POINTPOINTPOINT (1) Precautions when basic system application file is used When the boot drive of the basic system application is set to "A: Standard SD card", a basic system application file cannot be installed or updated. ■2. Display operation of system application information Function Description Reference page Information display of files and folders Displays the kind, name, data size, creation date and time of the file or folder. ➠ 15-5 Main Menu Data OS information Touch [Data]. Touch [OS information].
15.2 System Application Information 15 - 5
CONTROL OF VARIOUS DATA (DATA CONTROL) ■3. Display example of system application information No. Item Description (1) Name Displays the file name or folder name in the selected drive or folder. When the number of the characters of the file name or folder name exceeds 20, the 21th character and later are not displayed. (2) Version information Displays the software version. OS information Storage file/folder display screen (1) (2)
15 - 6 15.3 Resource Data Information
15.3 Resource Data Information
15.3.1 Alarm information
■1. Function of alarm information Advanced alarm log files and alarm log files stored in each drive (A: Standard SD card or C: Built-in flash memory) is displayed. The functions below can be carried out for files. For details of the advanced alarms, refer to the following manual. ➠ GT Designer3 (GOT2000) Help ■2. The display operation of alarm information Function Description Reference page Information display of files and folders Displays name, data size, creation date and time of file or folder. ➠ 15-7, 15-8 G2A CSV conversion Converts the G1A file of an advanced alarm log file to a CSV file. ➠ 15-9 G2A TXT conversion Converts the G1A file of an advanced alarm log file to a TXT file. ➠ 15-9 Del Deletes the file. ➠ 15-10 Copy Copies the file. ➠ 15-11 Select a drive and operate alarm log files Main Menu Data Resource DataSelect drive Touch [Data]. Touch [Resource Data]. Touch [Alarm info].
15.3 Resource Data Information 15 - 7
CONTROL OF VARIOUS DATA (DATA CONTROL) ■3. The display example of alarm information POINTPOINTPOINT (1) Display of creation date and time The creation date and time display is not updated even if a file is created or updated while displaying the alarm information display screen. If the screen currently displayed is closed (by moving the screen to the folder of the upper hierarchy, etc.) and the same screen is displayed again, the updated contents are displayed. No. Item Description (1) Select drive The drive which displays file or folder can be selected. When an SD card is not installed, the following drives are not displayed.
- SD card: [A: Standard SD card] (2) Kind Indicates whether the displayed name is file or folder. Displays the extension for a file and "DIR" for a folder. (3) Name Displays the file name or folder name. For the long file/folder name, entire part may not be displayed. Confirm the non-displayed part with the [Copy] button, etc. ➠ ■4 . Alarm information operation After confirmation, touch the [Cancel] button to cancel the operation. (4) Size Displays the size of the file displayed in Name. (5) Date, Time Displays the creation date and time of each file. (6) Operation switch Execution switch of each function. Alarm information: Storage file/folder display screenAlarm information screen (1) (3)(2) (4) (6) (5)
15 - 8 15.3 Resource Data Information ■4. Alarm information operation (1) The display operation of alarm information Step 1. If touch a drive of [Select drive], the information of the touched drive is displayed. Step 2. If touch a folder name, the information of the touched folder is displayed. Step 3. If touch a folder of ". .", the information of the folder of the one upper hierarchy is displayed. Step 4. If touch the button of the scrollbar, the screen scrolls up/down by one line. If touch the button, the screen scrolls up/down by one screen. Step 5. If a file name is touched, the file is selected. Step 6. For operations of G1A CSV conversion, G1A TXT conversion, deletion, copy, and graph, refer to the following. G1A CSV, G1A TXT ➠ This section (2) Delete ➠ This section (3) Copy ➠ This section (4) Step 7. If touch the [ ] button, the screen is closed. Alarm information: Storage file/folder display screen Alarm information screen
15.3 Resource Data Information 15 - 9
CONTROL OF VARIOUS DATA (DATA CONTROL) (2) G2A CSV conversion operation, G2A TXT conversion operation The selected G1A file is converted to a CSV file or TXT file. Step 1. Touch the G2A file to be converted to a CSV file or TXT file. Step 2. Touch [Convert]. Step 3. The following dialog box is displayed when touching the following button according to the file type to convert to.
- CSV file: [CSV] button
- TXT file: [TXT] button Step 4. Touch the [OK] button. The file is overwritten with the converted file.
15 - 10 15.3 Resource Data Information (3) Deletion operation Deletes the selected file. Step 1. Touch the file to be deleted. Step 2. If touch the [Delete] button, the dialog box mentioned left is displayed. If the [YES] button is touched, the file is deleted. If the [NO] button is touched, the deletion is canceled.
15.3 Resource Data Information 15 - 11
CONTROL OF VARIOUS DATA (DATA CONTROL) (4) Copy operation Copies the selected file. Step 1. Touch the file to be copied. Step 2. If the [Copy] button is touched, the Select drive screen is displayed. Step 3. Select a drive. Step 4. Select the copy destination folder and touch [Execute]. The file is copied.
15 - 12 15.3 Resource Data Information
15.3.2 Recipe information
Before using recipe information For writing/reading into/from a controller with this function or editing of recipe files on the personal computer, refer to the following. Specifications and operating procedure are described. ➠ GT Designer3 (GOT2000) Help ■1. Function of recipe information The recipe file used in the recipe function can be copied, deleted, and output in a file. In addition, it is possible to writing/reading into/from a controller by using this function, without creating the screen to operate the recipe. (Recipe setting of GT Designer3 is required.) Function Description Reference page Recipe information screen Information display of files and folders Displays name, data size, creation date and time of file or folder. ➠ 15-14 15-15 G2P CSV conversion Converts a G1P file of a recipe file to a CSV file. ➠ 15-16 G2P TXT conversion Converts a G1P file of a recipe file to a Unicode text file. ➠ 15-16 CSV/TXT G2P conversion Converts a CSV file or TXT file to a G1P file of a recipe file. ➠ 15-17 Del Deletes the file or folder. ➠ 15-18 Copy Copies the file. ➠ 15-19
15.3 Resource Data Information 15 - 13
CONTROL OF VARIOUS DATA (DATA CONTROL) ■2. Display operation of recipe information Select a drive and operate alarm log files Main Menu Data Resource DataSelect drive Touch [Data]. Touch [Resource Data]. Touch [Recipe info].
15 - 14 15.3 Resource Data Information ■3. Example of advanced recipe information display (1) Recipe information screen POINTPOINTPOINT (1) About the displayed file The files other than that for recipe are not displayed on the recipe information screen. No. Item Description (1) Select drive The target drive can be selected. (Even if an SD card is not installed, this message appears.) (2) Kind Indicates whether the displayed name is file or folder. Displays the extension for a file and "DIR" for a folder. (3) Name Displays the file name or folder name. For the long file/folder name, entire part may not be displayed. (4) Size Displays the size of the file displayed in Name. (5) Date, Time Displays the creation date and time of each file. (6) Operation switch Executio n switch of each function. Recipe Information Storage file/folder display screenRecipe Information screen (1) (3)(2) (4) (6) (5)
15.3 Resource Data Information 15 - 15
CONTROL OF VARIOUS DATA (DATA CONTROL) ■4. Recipe information operation (1) Display operation of recipe information Step 1. If touch a drive of [Select drive], the information of the touched drive is displayed. Step 2. If touch a folder name, the information of the touched folder is displayed. Step 3. If touch a folder of ". .", the information of the folder of the one upper hierarchy is displayed. Step 4. If touch the button of the scrollbar, the screen scrolls up/down by one line. If touch the button, the screen scrolls up/down by one screen. Step 5. If a file name is touched, the file is selected. Step 6. For operation of operating switches, refer to the following. G2P CSV, G2P TXT ➠ This section (2) CSV/TXT G2P ➠ This section (3) Delete ➠ This section (4) Copy ➠ This section (5) Step 7. If touch the [ ] button, the screen is closed.
15 - 16 15.3 Resource Data Information (2) G2P CSV conversion operation, G2P TXT conversion operation A recipe file (G2P file) is converted to a CSV file or Unicode text file that can be displayed/edited on a personal computer. Step 1. Touch the G2P file to be converted to a CSV file or TXT file. Step 2. Touch [Convert]. Step 3. Touch the following button in accordance with destination file type.
- CSV file: [CSV] button
- TXT file: [TXT] button Step 4. Touch the [OK] button. The file is overwritten with the converted file.
15.3 Resource Data Information 15 - 17
CONTROL OF VARIOUS DATA (DATA CONTROL) (3) CSV/TXT G2P conversion operation A CSV file or Unicode text file is converted to a recipe file (G1P file). Step 1. To select the file, touch the CSV file or TXT text file to be converted to a G2P file. Step 2. Touch the [Convert] button. Step 3. If the [OK] button is touched, the file is overwritten with the converted file.
15 - 18 15.3 Resource Data Information (4) Deletion operation Folders and files to be used on recipe are deleted. Step 1. Touch the folder or file to be deleted. Step 2. If touch the [Delete] button, the dialog box mentioned left is displayed. If the [YES] button is touched, the file or folder is deleted. (While executing, [Processing...] message appears on the screen.) If the [NO] button is touched, the deletion is canceled.
15.3 Resource Data Information 15 - 19
CONTROL OF VARIOUS DATA (DATA CONTROL) (5) Copy operation Files to be used in recipe are copied. Step 1. Touch the file to be copied. Step 2. If the [Copy] button is touched, the Select drive screen is displayed. Step 3. Select a drive. Step 4. Select the copy destination folder and touch [Execute]. The file is copied.
15 - 20 15.3 Resource Data Information ■5. Precautions (1) Precautions for operation (a) Precautions during folder/file operation (Create/Delete/Copy/File output, etc.) Even if the access to the SD card is inhibited while the GOT is processing folders and files, the processing continues. (Example: Even if the access to the SD card is inhibited while the GOT is creating a folder, the folder is created.) Therefore, do not pull out the SD card while the "Processing..." message is on the screen after the access to the SD card is inhibited. (b) While GOT is accessing to other file (Alarm data, etc) When folder/file processing for the recipe is executed while the GOT is in access to other file (SD card access LED ON), the GOT executes folder/file processing for the recipe after the processing for other file has completed. Therefore, it may take some time to finish the process of the recipe folder/file. (The "Processing..." message is displayed on the screen.) POINTPOINTPOINT Estimation of processing time The process may take time depending on the setting of advanced recipe file to be operated. (The more number of blocks increases, the longer it takes to process recipe folder/file.) The process for creating the first file may take time depending on the setting of advanced recipe file.
15.3 Resource Data Information 15 - 21
CONTROL OF VARIOUS DATA (DATA CONTROL)
15.3.3 Logging information
■1. Function of logging information Logging files created with the logging function can be copied, deleted or renamed, etc. Without using a personal computer, you can manage logging files on the GOT. For details of the logging function, refer to the following. ➠ GT Designer3 (GOT2000) Help ■2. Display operation of logging information Function Description Reference page Information display of files and folders Displays name, data size, creation date and time of file or folder. ➠ 15-22 15-23 G2L CSV conversion Converts a G1L file of a logging file to a CSV file. ➠ 15-24 G2L TXT conversion Converts a G1L file of a logging file to a Unicode text file. ➠ 15-24 Del Deletes the file or folder. ➠ 15-25 Copy Copies the file. ➠ 15-26 Select a drive and operate logging data files Main Menu Data Logging info.Select drive Touch [Data]. Touch [Resource Data]. Touch [Logging info].
15 - 22 15.3 Resource Data Information ■3. Example of logging information display POINTPOINTPOINT (1) About the displayed file The files other than that for logging are not displayed on the logging information screen. No. Item Description (1) Select drive The target drive can be selected. (Even if an SD card is not installed, this message appears.) (2) Kind Indicates whether the displayed name is file or folder. Displays the extension for a file and "DIR" for a folder. (3) Name Displays the file name or folder name. For the long file/folder name, entire part may not be displayed. (4) Size Displays the size of the file displayed in Name. (5) Date, Time Displays the creation date and time of each file. (6) Operation switch Execution switch of each function. Logging Information Storage file/folder display screenLogging Information (1) (3)(2) (4) (6) (5)
15.3 Resource Data Information 15 - 23
CONTROL OF VARIOUS DATA (DATA CONTROL) ■4. Logging information operation (1) Display operation of logging information Step 1. If touch a drive of [Select drive], the information of the touched drive is displayed. Step 2. If touch a folder name, the information of the touched folder is displayed. Step 3. If touch a folder of ". .", the information of the folder of the one upper hierarchy is displayed. Step 4. If touch the button of the scrollbar, the screen scrolls up/down by one line. If touch the button, the screen scrolls up/down by one screen. Step 5. If a file name is touched, the file is selected. Step 6. For operation of operating switches, refer to the following. G2L CSV, G2L TXT ➠ This section (2) Delete ➠ This section (3) Copy ➠ This section (4) Step 7. If touch the [ ] button, the screen is closed.
15 - 24 15.3 Resource Data Information (2) G2L CSV conversion operation, G2L TXT conversion operation A logging file (G2L file) is converted to a CSV file or Unicode text file that can be displayed/edited on a personal computer. Step 1. Touch the G2L file to be converted to a CSV file or TXT file. Step 2. Touch [Convert]. Step 3. Touch the following button in accordance with destination file type.
- CSV file: [CSV] button
- TXT file: [TXT] button Step 4. Touch the [OK] button. The file is overwritten with the converted file.
15.3 Resource Data Information 15 - 25
CONTROL OF VARIOUS DATA (DATA CONTROL) (3) Deletion operation Folder and file to be used on logging are deleted. Step 1. Touch the folder or file to be deleted. Step 2. If touch the [Delete] button, the dialog box mentioned left is displayed. If the [YES] button is touched, the file or folder is deleted. (While executing, [Processing...] message appears on the screen.) If the [NO] button is touched, the deletion is canceled.
15 - 26 15.3 Resource Data Information (4) Copy operation Folder to be used in logging is copied. Step 1. Touch the file to be copied. Step 2. If the [Copy] button is touched, the Select drive screen is displayed. Step 3. Select a drive. Step 4. Select the copy destination folder and touch [Execute]. The file is copied.
15.3 Resource Data Information 15 - 27
CONTROL OF VARIOUS DATA (DATA CONTROL) ■5. Precautions (1) Precautions for operation (a) Precautions during folder/file operation (Create/Delete/Copy/File output, etc.) Even if the access to the SD card is inhibited while the GOT is processing folders and files, the processing continues. (Example: Even if the access to the SD card is inhibited while the GOT is creating a folder, the folder is created.) Therefore, do not pull out the SD card while the "Processing..." message is on the screen after the access to the SD card is inhibited. (b) While GOT is accessing to other file (Alarm data, etc) When folder/file processing for the logging is executed while the GOT is in access to other files (SD card access LED ON), the GOT executes folder/file processing for the logging after the processing for other files is completed. Therefore, it may take some time to finish the process of the logging folder/file. (The "Processing..." message is displayed on the screen.)
15 - 28 15.3 Resource Data Information
15.3.4 Image file management
■1. Function of image file management Deletes, copies, and moves the file created by the hard copy function. For details of the hard copy function, refer to the following. ➠ GT Designer3 (GOT2000) Help ■2. Display operation of image file management Function Description Reference page Information display of files and folders Displays the kind, name, data size, creation date and time of the file or folder. ➠ 15-29 15-30 Delete Deletes the file. ➠ 15-31 Copy Copies the file. ➠ 15-32 Select a drive and operate Image data files Main Menu Data Resource dataSelect drive Touch [Data]. Touch [Resource Data]. Touch [Image file].
15.3 Resource Data Information 15 - 29
CONTROL OF VARIOUS DATA (DATA CONTROL) ■3. Display example of image file management POINTPOINTPOINT (1) Display of creation date and time The creation date and time display is not updated even if a file is created or updated while the image file management screen is displayed. To display the updated creation date and time, close the screen currently displayed (by moving to the upper hierarchy folder, etc.) and display the screen again. No. Item Description (1) Select drive The drive which displays file or folder can be selected. When an SD card is not installed, the following drives are not displayed.
- SD card: [A: Standard SD card] (2) Kind Indicates whether the displayed name is file or folder. Displays the extension for a file and "DIR" for a folder. (3) Name Displays the file name or folder name. For the long file/folder name, entire part may not be displayed. Confirm the non-displayed part with the [Copy] button, etc. ➠ (3) Copy operation After confirmation, touch the [Cancel] button to cancel the operation. (4) Size Displays the size of the file displayed in Name. (5) Date, Time Displays the creation date and time of each file. (6) Operation switch Execution switch of each function. (2) (3) (6) (4) (5) Image file Information (1) Image file Information Storage file/folder display screen
15 - 30 15.3 Resource Data Information ■4. Operation of image file management (1) Display operation of image file management Step 1. If touch a drive of [Select drive], the information of the touched drive is displayed. Step 2. If touch a folder name, the information of the touched folder is displayed. Step 3. If touch a folder of ". .", the information of the folder of the one upper hierarchy is displayed. Step 4. If touch the button of the scrollbar, the screen scrolls up/down by one line. If touch the button, the screen scrolls up/down by one screen. Step 5. If a file name is touched, the file is selected. Step 6. For the operations of the delete, copy, and rename, refer to the following. Delete ➠ This section (2) Copy ➠ This section (3) Step 7. If touch the [ ] button, the screen is closed.
15.3 Resource Data Information 15 - 31
CONTROL OF VARIOUS DATA (DATA CONTROL) (2) Deletion operation Deletes the selected file. Step 1. Touch the file to be deleted. Step 2. If touch [Delete] button, the screen mentioned left is displayed. If the [YES] button is touched, the file is deleted. If the [NO] button is touched, the deletion is canceled.
15 - 32 15.3 Resource Data Information (3) Copy operation Copies the selected file. Step 1. Touch the file to be copied. Step 2. If the [Copy] button is touched, the Select drive screen is displayed. Select a drive. Step 3. If the copy destination folder is touched, the screen display is changed to the folder of copy destination. At this time, it cannot be copied into the same folder where the file exists. Select other folders. Step 4. If touch the [Execute] button, the file is copied.
15.4 SD Card Access 15 - 33
CONTROL OF VARIOUS DATA (DATA CONTROL)
15.4 SD Card Access
15.4.1 Functions of SD card access
When the GOT is turned on, an SD card can be installed or removed to/from the GOT without damage to the data in the SD card.
15.4.2 Display operation of SD card access
15.4.3 Operation of SD card access
Step 1. Touch a setting item to change the setting. [Permissions] [Access inhibit] When installing or removing an SD card, always set [Access inhibit]. SD card access Main Menu Data
15 - 34 15.5 SD Card Format
15.5 SD Card Format
■1. Function of SD card format An SD card is formatted. ■2. Display operation of SD card format Main Menu Data Touch [Data]. Touch [SD card format].
15.5 SD Card Format 15 - 35
CONTROL OF VARIOUS DATA (DATA CONTROL) ■3. Operation of SD card format POINTPOINTPOINT Restrictions on formatting
- When using an unformatted SD card in the GOT, format it by a personal computer. The GOT cannot format the unformatted SD card.
- The format of the GOT does not change the file system (Example: FAT16) of the SD card and inherits the file system before the format. Step 1. Install an SD card to the GOT. For installation/removal procedure of an SD card, refer to the following. ➠ 8.1.2 Installation/removal procedure of SD card Step 2. Touch and select the drive to format by drive selection. Step 3. If touch the [FORMAT] button, the password input screen is displayed. Step 4. Type and touch the [Enter] key. The dialog box shown on the left will appear. (The password is fixed to 1111.) Confirm the contents of the dialog box, and touch the [YES] button to format the SD card. To cancel the format, touch the [NO] button. Step 5. When the formatting is completed, the completion dialog mentioned left is displayed. Step 6. To close the dialog box, touch the [OK] button. 1 1 1 1
15 - 36 15.6 Clear data
15.6 Clear data
15.6.1 Clear data functions
This function deletes the project data and resource data that are written to the GOT.
15.6.2 Clear data display
15.6.3 Clear data operation
Data deletion cannot be canceled once the [YES] button is pressed at the confirm deletion prompt. Double check before touching the [YES] button. Step 1. Touch the type of data on the screen to be deleted.Step 2. The dialog box on the left is displayed for confirmation. Touch the [YES] button to delete the data, or the [NO] button to cancel. Clear data Main Menu Clear data Touch [Data]. Touch [Clear data]. Touch [Project data] or [Resource data]. Touch
15.7 Data Copy 15 - 37
CONTROL OF VARIOUS DATA (DATA CONTROL)
15.7 Data Copy
The project data and basic system application are transferred by using an SD card. POINTPOINTPOINT Copy from the memory board to the GOT Copying from the memory board to the GOT when turning on the power to the GOT. Refer to the following. ➠ 18.1 Installation Method When the GOT is Turned On
15.7.1 Display operation of data copy
[Data]. Touch [Data copy].
15 - 38 15.7 Data Copy
15.7.2 Operation of data copy
Step 1. Select the copy direction. The selection mark is displayed on the side of the selected key. GOT SD card: Copy from the GOT to the memory board SD card GOT: Copy from the SD card to the GOT Step 2. After selecting the direction, touch the [OK] button. To abort copy, touch the [ABORT] button. Step 3. Confirm the copy direction and copy target. When they are set correctly, touch the [OK] button. To change the setting, touch the [CANCEL] button. Step 4. The dialog box on the left is displayed for confirmation. Touch the [YES] button to start copying and [NO] button to abord. Step 5. While the copy is executed, the dialog box on the left is displayed. Touch Touch Touch Touch
15.7 Data Copy 15 - 39
CONTROL OF VARIOUS DATA (DATA CONTROL) POINTPOINTPOINT When installing or removing an SD card Always set [Permissions] on the GOT. For details, refer to the following. ➠ 15.4 SD Card Access ■1. Error display When copying is not available between the GOT and the SD card, check the following contents according to the GOT error display. Step 6. Copy is completed. If the [ESC] button is touched, the screen is closed. If an error occurs during copy, an error message appears. For details of error messages, refer to the following. ➠ Error display When only the project data was copied to the GOT, touch the [ESC] button to restart the GOT and display the user-created screen. When the basic system application was copied, the GOT will automatically start up and display the user-created screen. (If the project data does not exist, a message appears to notify that the project data does not exist.) Error message Remedy SD card is not attached. Install an SD card to the GOT. GOT type is unmatch. The model set for the data in the SD card does not match with that of the copy target GOT. Use the same model data as that of the copy target GOT. Write protection switch ON. The write protection switch of the SD card is ON. Turn off the write protection switch. Available package data is notexisted. There is no data to be a copy target in the copy source. Store the data to be copied in the copy source and copy it again. Touch
15 - 40 15.7 Data Copy
16.1 Device Monitor Function 16 - 1
GOT SELF CHECK (DEBUG) 16. GOT SELF CHECK (DEBUG) The debug includes functions to check the PLC system status and to improve troubleshooting efficiency. The following is available as the debug.
16.1 Device Monitor Function
For a controller connected to the GOT, forcibly turning on or off devices of the controller and changing the set value or present value are available.
16.1.1 System configuration
This section describes the controller names and connection types between the GOT and a controller that are applicable to the device monitor function. For details of communication units and cables for each connection type, refer to the following manual. ➠ GOT2000 Series Connection Manual For GT Works3 Version1 ■1. Target controller ■2. Required system application POINTPOINTPOINT Checking method of the version of basic system application and communication driver Check the version of the basic system application and communication driver installed in the GOT at [System Application Information] of the utility. Refer to the following for details. ➠ 15.2 System Application Information Item Description Reference Device monitor For a controller connected to the GOT, forcibly turning on or off devices of the controller and changing the set value or present value are available. ➠ 16 - 1 FX list editor The sequence program of FX PLC can be list edited. ➠ 16 - 14 FX3U-ENET-ADP communication setting function The communication set value of the FX3U-ENET-ADP stored in the CPU can be changed. ➠ 16 - 42 Controller Connection type QCPU (Q mode) Direct CPU connection, Comput er link connection, CC-Link(G4) connection QnACPU Direct CPU connection, Computer link connection FX CPU Direct CPU connection System application Version Basic system application - Communication driver MELSEC-Q/L/QnA - MELSEC-FX - CC-Link(G4) -
16 - 2 16.1 Device Monitor Function
16.1.2 Devices that can be monitored
For further information about the monitor device names that can be monitored and the scope, see the following: ➠ GT Designer3 (GOT2000) Help
16.1.3 Precautions
(1) Monitoring and testing real number data Real number data cannot be monitored and tested. All word devices containing real number data are monitored in integer data (binary data). (2) Monitoring devices in 32-bit (two-word) module When monitoring word devices (T, C, D, W, etc.) in 32-bit (two-word) module, those with 32 bits of data remaining are monitored. Devices with 16 bits (one-word) of data remaining are not monitored. If an odd number is specified for the first monitor device number, the last device number of the specified controller will not be displayed. (Example) When the data entry of the QnACPU is monitored in units of 32 bits from odd numbers (D1, D3...) (3) Changing the timer/counter set values of QnACPU The timer/counter set values of QnACPUs whose date on the CPU rating plate is after [9707B] can be changed. <Information on the rating plate> D1017 D1018 D1019 D1020 D1021 D1022 D1023 (Device name) Unit of monitor display Nothing displayed PROGRAMMBLE CONTROLLER DATE 9707 B Function versionDate of manufacture
16.1 Device Monitor Function 16 - 3
GOT SELF CHECK (DEBUG)
16.1.4 Display operation of device monitor
Device monitor Channel Setting Touch [Debug]. Touch [Device monitor].
16 - 4 16.1 Device Monitor Function
16.1.5 Information displayed on the device monitor screen and key functions
■1. Device monitor screen The information displayed on the device monitor screen is described below. No. Item Settings 1) Device name Displays the device name. 2) Device No. Displays the device number. 3) Bit device ON/OFF Timer/Counter contact ON/OFF Displays ON/OFF information of bit devices and timer/counter contacts : ON : OFF 4) Data type DW : Indicates that the device value is a 32-bit (two-word) module. Nothing displayed: Indicates that the device value is a 16-bit (one-word) module. Present value of word device Present value and set value of timer/ counter [Decimal number] 16-bit (one-word) module: Six digits (including a digit for a sign) are displayed. (Display example: -12345) 32-bit (two-word) module: Ten digits (including a digit for a sign) are displayed. (Display example: -123456789) [Hexadecimal number] 16-bit (one-word) module: Four digits are displayed. (Display example: H AB12) 32-bit (two-word) module: Eight digits are displayed. (Display example: H ABCDE123) 6) Counting method Displays the counting method when registering the counters from C200 to C255. UP: Up count mode DOWN: Down count mode 7) Reset coil ON/OFF Displays the reset coil state when registering the timer/counter for the FXCPU. : ON : OFF 8) N/W Sets or displays the network No. when the PLC is on the network. 9) ST Sets or displays the station No. when the station No. is assigned to the PLC. 10) CPU No. 0 to 4: This item must be set only when the GOT is connected to the Q series CPU in the multiple CPU system or QnUCPU. Changing the CPU No. cancels the registration for all the devices. ➠ 16.1.7 Device registration (1) (6) (7)
16.1 Device Monitor Function 16 - 5
GOT SELF CHECK (DEBUG) ■2. Key functions The following table describes the key functions displayed on the device monitor screen. Key switch Function DEV Switches the screen to the device registration key window for registering devices to be monitored. ➠ 16.1.7 Device registration TEST Switches the quick test mode between enabled and disabled states. ➠ 16.1.8 Quick test DEC/HEX Switches the numerical notation of word de vice values between decimal and hexadecimal numbers. Scrolls the data list up and down by one line and displays the devices before or after the device which is currently registered and placed in the top or bottom line. : Scrolls the list up by one line to display the device number right before the device number displayed in the top line. : Scrolls the list down by one line to display the device number right after the device number displayed in the bottom line. Exits the device monitor, and then the screen returns to the debug screen.
16 - 6 16.1 Device Monitor Function
16.1.6 Basic operation of device monitor
The following explains basic operations of the device monitor. Debug With no registered device With registered devices DEV TEST DEC/HEX Register devices if necessary. Execute the quick test if necessary. Switch the numerical notation of word device values between decimal and hexadecimal numbers if necessary. Touch [Device monitor]. Touch Touch Touch
16.2.7 Selection and
16.2.8 Displaying sequence
16.1 Device Monitor Function 16 - 7
GOT SELF CHECK (DEBUG)
16.1.7 Device registration
The following explains the procedures for device registration. For the keyboard operations, refer to the next page. No. Item Settings 1) Data type 32 : Indicates that the device value is a 32-bit (two-word) module. Nothing displayed: Indicates that the device value is a 16-bit (one-word) module. 2) Device name Set the device name and device number to be monitored. 3) Device No. Specify the CPU No. of the device to be registered when connecting the GOT to a Q series CPU in the multiple CPU system or QnUCPU. Device monitor Connecting to a Q series CPU in the multiple CPU system or QnUCPU 1) 2) 3) Connecting to a CPU other than the Q series CPU in the multiple CPU system and QnUCPU When registering multiple devices, repeat the procedures. Touch the DEV key. Set 1) to 3) by using the keyboard, and then touch the ENT key. The device registration is completed. Input the CPU No. with the ten-key, and then touch the ENT key. Keyboard Touch Touch
16 - 8 16.1 Device Monitor Function POINTPOINTPOINT Keyboard operations (1) Keyboard functions (2) Input procedures Ends the device registration. Select a data type. [32]: Sets to the two-word. [16]: Sets to the one-word. Device name keyboard Deletes all input numbers. Registers the input device. (The device registration is completed.) Device number keyboard Ends the device registration. Input a device name. (ex:D) Select a data type. (ex:16 bit) Input a device number. (ex:12) The device registration is completed by touching the [ENT] key. Touch [16] key. Touch [32] key.
16.1 Device Monitor Function 16 - 9
GOT SELF CHECK (DEBUG) POINTPOINTPOINT Precautions for device registration (1) Data type Device monitor screens display the data type as shown below.
- DW : 32-bit (two-word) module
- Nothing displayed : 16-bit (one-word) module (2) CPU No. specification Changing the CPU No. after registering devices cancels the registration for all the devices. Check the CPU No. before registering the devices. (3) Station No. specification Changing the station No. after registering devices cancels the registration for all the devices. Check the station No. before registering the devices. (4) Holding registered devices The registration for the devices is not canceled after exiting the device monitor. Restarting the GOT cancels the registration for all the devices. (5) The number of registered devices The number of registered devices must be within the maximum number of devices that can be displayed on the GOT. For registering an additional device, the registration for the device in the top line is canceled and the additional device is displayed in the bottom.
16 - 10 16.1 Device Monitor Function
16.1.8 Quick test
The quick test operation procedure for monitor devices is described below. WARNING
- Before performing the quick test operations of device monitor (such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter), read through the manual carefully and make yourself familiar with the operation method. During quick test operation, never change the data of the devices which are used to perform significant operation for the system. False output or malfunction can cause an accident. Device monitor Enable the quick test mode. (1) Quick test of bit devices (2) Quick test of word devices Check that the quick test operation is enabled. Touch
16.1 Device Monitor Function 16 - 11
GOT SELF CHECK (DEBUG) (1) Quick test of bit devices (Operation example) Change the status of bit device M12 from OFF to ON . The selected bit device is switched from (OFF) to (ON). Touch the bit device to be switched between ON and OFF states. The device name and device number of the selected bit device are highlighted. Touch
16 - 12 16.1 Device Monitor Function (2) Quick test of word devices (Operation example) Change the device value of word device D200 from 43 to 100. Conditions: Data range: 16 bits, device value display format: decimal number The device value of D200 is changed from 43 to 100. Touch the device value to be changed. Input a device value by using the keyboard. Input "100" for the operation example. Touch [ENT] key.
16.1 Device Monitor Function 16 - 13
GOT SELF CHECK (DEBUG) POINTPOINTPOINT When the cursor is displayed When the cursor is displayed, touch the [ ] or [ ] key to move the cursor to the upper or lower registered device. Touch
16 - 14 16.2 FX List Editor
16.2 FX List Editor
The MELSEC-FX list editor can change the sequence programs on the FX PLC.
16.2.1 Display operation of FX list editor
[Debug]. Touch [FX list editor].
16.2 FX List Editor 16 - 15
GOT SELF CHECK (DEBUG) ■1. Parameters and sequence programs are easy to maintain. You can check or partly correct, change or add FX PLC parameters and sequence programs simply by operating keys. You can easily edit sequence programs without preparing any peripheral unit other than the GOT. ■2. Errors that occur during list editing can be checked easily. Error messages, error codes, and number of steps for errors that occur in the FX PLC can be checked. Details can be checked immediately even for errors that occur during list editing. ■3. Commands and devices can be searched and displayed. Commands and devices used in sequence programs can be searched. The correction position can be searched for cases such as when you want to correct a specific device. Changed (Example of changing sequence program commands) LD X000 OUT Y020 LD X001 LD X000 OUT Y030 LD X001 Searched device M800 Displays the searched device. LD M 800 OUT T 10 K 100 LD X 002
16 - 16 16.2 FX List Editor
16.2.2 Specifications
■1. System configuration This section describes the system configuration of the MELSEC-FX list editor. For the setting method in each connection form, used communication unit/cable and cautions on connection form, refer to the following manual. GOT2000 Series Connection Manual For GT Works3 Version1 ■2. Controllers that can be edited with the MELSEC-FX list editor ■3. Functions list and monitor conditions The following shows the memory that can be monitored by the MELSEC-FX list editor and the FX PLC status conditions. ( : Can be monitored : Can be monitored under certain conditions : Cannot be monitored) *1 The operation is available only when the protect switch is OFF. *2 The available memory differs depending on the FX PLC being used. For details, refer to the following. ➠ The hardware manual of the FX PLC being used Target controller FX CPU Function Memory that can be monitored *2 FX PLC status ReferenceBuilt-in memory RAM memory cassette EEPROM memory cassette, flash memory cassette EPROM memory cassette Reading sequence programs Displaying sequence programs RUN/STOP ➠ 16.2.8 Searching commands/ devices ➠ 16.2.9 Writing sequence programs Writing commands *1 For Stop only ➠ 16.2.10 Changing operands/ set values ➠ 16.2.12 Inserting commands ➠ 16.2.10 Deleting commands ➠ 16.2.12 Sequence program all clear ➠ 16.2.13 PLC diagnostics RUN/STOP ➠ 16.2.14 Parameter setting Display ➠ 16.2.15 Setting *1 For Stop only Keyword RUN/STOP ➠ 16.2.16
16.2 FX List Editor 16 - 17
GOT SELF CHECK (DEBUG)
16.2.3 Access range
The access range is the same as the access range when the GOT is connected to a controller. For details of the access range, refer to the following. ➠ GT Designer3 (GOT2000) Help GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1
16.2.4 Precautions
(1) Using other peripheral equipment for sequence program/parameter change When using the MELSEC-FX list editor, do not change programs or parameters in the PLC CPU from other peripheral equipment. If programs or parameters are changed, exit the MELSEC-FX list editor once and start the MELSEC-FX list editor again. If the program on one PLC is changed carelessly from multiple units of peripheral equipment (including GOT), the contents of the program in the PLC CPU and the peripheral equipment may not be the same, resulting in an unintended operation of the PLC CPU. (2) Sequence program change Stop the FX PLC before changing (writing, inserting, deleting) a sequence program or changing parameters. Operation is not possible with the FX PLC running. (3) If you press the [GO] key but the system does not proceed to the next operation (for example, a search) Check the input contents (applied instruction number, device value, etc.). (4) When using list monitor Only devices to be used for basic instructions can be monitored. The status of devices (word, bit) to be used for application instructions cannot be monitored.
16 - 18 16.2 FX List Editor
16.2.5 Display operation
■1. Operation to display The following describes the outline for displaying the operation screen of the MELSEC-FX list editor. POINTPOINTPOINT (1) How to disp lay the utility For how to display the utility, refer to the following. ➠ 9.2 Utility Function List (2) If the project data has not been downloaded The MELSEC-FX list editor can be started from the utility even if the project data has not been downloaded to the GOT. Start Turn on the power to the GOT. The MELSEC-FX list editor is started. Display the utility. Refer to the following manual for how to set the special function switch. GT Designer3 (GOT2000)HELP Touch the special function switch. Starting from the utility Starting from the special function switch (MELSEC-FX list editor) set in the project data End Enter the keyword. Subsection 15.2.16 Keyword After the utility is displayed, touch [Debug] [MELSEC-FX List editor] from the main menu. For how to display the utility, refer to the user's manual of the GOT to be used. When no keyword is registered in the connected FX PLC When a keyword is registered in the connected FX PLC
16.2 FX List Editor 16 - 19
GOT SELF CHECK (DEBUG) ■2. Changing screens This section describes how to change the screen. *1 With setting special function switches (FX list monitor), the list monitor can be started on the monitor screen. When the list monitor is started on the monitor screen, the list editor cannot be used. For how to set special function switches, refer to the following. ➠ GT Designer3 (GOT2000) Help Utility Main Menu or user-created monitor screen Start Communication setting window [ChNo.] [PLC diagnostics] [Parameter setting] MORE MORE CLR OP GO [Keyword setup] [List Monitor] OP CLR GO GO GO
16 - 20 16.2 FX List Editor
16.2.6 Operation procedures
This section describes the contents of the MELSEC-FX list editor and the key functions displayed on the screen. ■1. Key arrangement and a list of key functions The arrangement and functions of the keys displayed on the MELSEC-FX List Editor window are described below. ■2. Displayed contents No. Item Display contents 1) Channel No Displays the currently selected channel number. Touching "ChNo." displays the communication setting window. The communication setting window is not displayed if the MELSEC-FX list editor is started from the FX ladder monitor. 2) Mode Displays a mode for MELSEC-FX list editor. ➠ 16.2.7 Selection and operation of modes [Monitor] is displayed when the list monitor is executed. ➠ 16.2.17 List monitor 3) Error message Displays the contents of errors that occur with the MELSEC-FX list editor. ➠ 16.2.19 Error messages and corrective actions 4) List display area Displays the sequence program in list format (12 digits). The position (line) that can be edited is displayed with a bar. 5) Key area Displays the keys that can be used with the MELSEC-FX list editor.
16.2 FX List Editor 16 - 21
GOT SELF CHECK (DEBUG) ■3. Key functions The table below shows the functions of the keys that are used for the operation on the MELSEC-FX list editor screen. ■4. Keyboard switching Touching the MORE button switches the command keyboard 1 and command keyboard 2. When you touch the button for a keyboard function, the optimum keyboard for input for that function is displayed automatically. Key Function Displays the currently selected channel number. The communication setting window is not displayed if the MELSEC-FX list editor is started from the FX ladder monitor. Selects a mode for MELSEC-FX list editor. ➠ 16.2.7 Selection and operation of modes Displays the PLC diagnostics, parameter setting, and keyword selection menu. Switches between command keyboard 1 and command keyboard 2. ➠■ 4 . Keyboard switching When inputting commands: Cancels the key input when only part of the command has been input. ➠ 16.2.18 Action for an incorrect key input When option menu is displayed: Closes the option menu. Commands cannot be deleted with this key. ➠ 16.2.12 Deleting commands Space key. This key is used when setting timers and counters, writing applied commands, etc. Displays the list from a specified step number when the step number is input. Moves the list display area bar up and down and switches the line being edited. Determines the key operation. to , to , etc. Inputs commands, device names, etc. The key contents depend on the input contents. The commands that can be used differ depending on the target FX PLC. Refer to the manual for the FX PLC to be used. Exits the MELSEC-FX list editor. Touch Touch Command keyboard 1 Command keyboard 2
16 - 22 16.2 FX List Editor
16.2.7 Selection and operation of modes
The MELSEC-FX list editor has four modes: READ, WRITE, INSERT, and DELETE. Select an appropriate mode for the intended operation. For more information on the mode to select, refer to the function operations from subsection 15.3.8. ■1. How to change modes Touch the MODE button. Each time you touch this button, the mode changes. ■2. In the case the mode cannot be changed In the following cases, the mode can be changed to the READ mode only. If you try to change to other than READ mode, an error message is displayed. To change to other than READ mode, take the action below. Error message Cause Corrective action PLC is running The FX PLC is in the RUN status. Stop the FX PLC. Can not write. The protect switch of the EEPROM memory cassette is on. Switch off the protect switch of the EEPROM memory cassette. The EPROM memory cassette is enabled. Set a memory other than EPROM as the memory to write to. Touch the button. The current mode is displayed.
16.2 FX List Editor 16 - 23
GOT SELF CHECK (DEBUG)
16.2.8 Displaying sequence programs
Sequence programs are read from the FX PLC to the GOT and displayed. There are two displaying methods: specifying the step number, and scrolling one screen at a time. ■1. Display using cursor keys (1) Operation (2) Example Scroll one line upward or downward. ■2. Display specifying the step number (1) Operation (2) Example Displaying step number 123. POINTPOINTPOINT When the specified step number is the operand of an applied instruction If the specified step number is a timer (T) or counter (C) set value or the operand of an applied instruction, that command section is displayed at the head. Scroll with OR
128 MPP
129 DIV 23
Scrolling one line upward Scrolling one line downward STEP GOInput the step number. STEP GO Input the step number Step number
0 LD X 000
1 OUT Y 000
2 LDI M 100
3 MOV 12
123 MOV 12
16 - 24 16.2 FX List Editor ■3. Display scrolling one screen at a time (1) Operation (2) Example Displaying with scrolling one screen at a time. MODE GO (Read mode) MODE GO Set the READ mode. Displaying with scrolling one screen at a time. < WRITE > < READ >
16.2 FX List Editor 16 - 25
GOT SELF CHECK (DEBUG)
16.2.9 Searching commands/devices
Displays a command or device by searching it in sequence program from Step 0. ■1. Command search (1) Operation *1 If the command you want to search for is not on the keyboard, touch the key to switch to the other keyboard. When searching for an applied instruction, touch the key and input the applied instruction number. When searching for a label, touch or and input the pointer number. ➠ 16.2.10 Writing commands *2 Input only when searching for commands requiring a device name and device number. *3 After the search results are displayed, you can continue search ing with the same conditions by touching the key. Touching any key other than the key ends the search. (2) Example Searching for LD M8000 POINTPOINTPOINT Pointer (P, I) searches For pointer searches, only labels are searched. Pointers specified as operands in applied instructions are not searched. MODE (Read mode) *1 *2 *3 Select the command to search for. Input the device name and device number. GO GO MORE FNC P I GO GO M800 0 G O GO (Continue to search with the same conditions) MODE LD < WRITE > < READ > Search command Select the command to search for. ( ) Set the READ mode.
8 LD M 8000
9 OUT T 10
12 LD X 002
24 LD M 8000
25 OUT T 0
28 OUT T 1
16 - 26 16.2 FX List Editor ■2. Device search (1) Operation *1 After the search results are displayed, you can continue searching with the same conditions by touching the key. Touching any key other than the key ends the search. (2) Example Searching for LD M8000 POINTPOINTPOINT Devices that cannot be searched The following devices cannot be searched.
- Pointers, interrupt pointers
- Constant K, constant H, constant E
- Digit specification of bit device
- Special function unit/block buffer memory
- Devices specified with the operand of an applied instruction Pointers and interrupt pointers can be searched for with command searches. ➠ ■1. Command search * 1 MODE SP GO GOInput the device name and device number. (Read mode) GO GO GO (Continue to search with the same conditions) GO MSP 8 0 0 0 MODE Search device Set the READ mode.
M8000< WRITE > < READ >
16.2 FX List Editor 16 - 27
GOT SELF CHECK (DEBUG)
16.2.10 Writing commands
Writes a sequence program to the FX PLC. (Overwrite/Insert) ■1. Writing basic commands (1) Operations (a) Inputting command only (Ex.: ANB, ORB command etc.) (b) Inputting command and device (LD, AND commands etc.) (c) Inputting command, No. 1 device, No. 2 device (MC, OUT (T, C) commands, etc.) POINTPOINTPOINT Moving the cursor to the position to write the command When starting to write a command, place the cursor on the command line (the line on which the step number is displayed). You cannot write a command with the cursor on an operand or set value line. (2) Example (a) Writing ORB command MODE GOStop the FX PLC Input the command For overwriting: (WRITE mode) For insertion: (INSERT mode) MODE GO Stop the FX PLC Input the device name and device number Input the command For overwriting: (WRITE mode) For insertion: (INSERT mode) GOSP MODEStop the FX PLC Input the device name and device numberInput the command For overwriting: (WRITE mode) For insertion: (INSERT mode) Input the device name and device number Command line (Place the cursor on this line.) Operand, set value line (Cannot operate on this line.) With or , move the cursor to the position to overwrite/insert the command. Stop the FX PLC
4 LDI X 004
5 AND X 005
6 NOP
7 NOP
6 ORB
< READ > < WRITE >
16 - 28 16.2 FX List Editor (b) Inputting LD X000 (c) Inputting OUT T100 K19 0XLD GO MODE Set the WRITE or INSERT mode. Stop the FX PLC
0 NOP
1 NOP
2 NOP
3 NOP
< READ > < WRITE > With or , move the cursor to the position to overwrite/insert the command. OUT SP K 19 GO 100T
100 OUT M 100
101 NOP
102 NOP
103 NOP
101 OUT T 100
104 NOP
< READ > < WRITE > With or , move the cursor to the position to overwrite/insert the command. Set the WRITE or INSERT mode. Stop the FX PLC
16.2 FX List Editor 16 - 29
GOT SELF CHECK (DEBUG) ■2. Writing applied instructions (1) Operation *1 (double word command) and (pulse execution format command) can also be input after the applied instruction number is input. *2 Inputting in the order is also possible. *3 When a command specifies multiple devices for operations, input the key followed by the device name and device number. POINTPOINTPOINT (1) Moving the cursor to the position to write the command When starting to write a command, place the cursor on the command line (the line on which the step number is displayed). You cannot write a command with the cursor on any other line. (2) Commands using a text string constant for a command operand (such as ASC command) With the MELSEC-FX list editor, text string constants cannot be written as operands. (such as ASC commands) Use GX Developer for writing such commands. (2) Example Input "DMOVP D0 D2". Applied instruction number Stop the FX PLC Input the device name and device number. MODE PS P G O FNC D For overwriting: (WRITE mode) For insertion: (INSERT mode) D P P D Command line (Place the cursor on this line.) Operand, set value line (Cannot operate on this line.) SPD 1 2 P SPD 0 D 2 GO MODE FNC
200 NOP
201 NOP
202 NOP
203 NOP
200 FNC
200 DMOVP 12
209 NOP
< READ > < WRITE > Set the WRITE or INSERT mode. With or , move the cursor to the position to overwrite/insert the command. Stop the FX PLC
16 - 30 16.2 FX List Editor
16.2.11 Changing operands, set values
Changes the operand section of an applied instruction and OUT (T, C) command set value. ■1. Operation *1 For decimal numbers, input K, then the number. For hexadecimal numbers, input H, then the number. POINTPOINTPOINT Moving the cursor to the line on which the operand or set value is to be changed When starting to change an operand or a set value, place the cursor on the line of the operand or set value to be changed (the line on which the step number is not displayed). If you place the cursor on the command line, the input operation is not possible. ■2. Example Changing "MOV D0 D10" to "MOV D0 D123" MODE SP GO (Read mode) Stop the FX PLC Input the device name and device number D 1 2 3SP GO MODE
8 LD M 10
< READ > < WRITE > Set the WRITE mode. Stop the FX PLC Move the cursor to the changed location with or
16.2 FX List Editor 16 - 31
GOT SELF CHECK (DEBUG)
16.2.12 Deleting commands
Deletes one command at a time from a sequence program. ■1. Operation POINTPOINTPOINT When moving the cursor to the position where the command is to be deleted. Place the cursor on the command line (the line on which the step number is displayed). You cannot delete the command if the cursor is placed on the line of an operand or set value. ■2. Example Deleting "OUT T10 K100" MODE GOStop the FX PLC Move the cursor to the command to be deleted. (DELETE mode) GO
9 LD X 002
10 OR X 020Z1
13 AND D 1500.F MODE STEP Set the DELETE mode. Move the cursor to the command to be deleted with , or the key. < READ > <DELETE > Stop the FX PLC
16 - 32 16.2 FX List Editor
16.2.13 Sequence program all clear
Clears all the sequence programs. ■1. Operation ■2. Example Clears all the sequence programs. POINTPOINTPOINT Items cleared when All Clear for a sequence program is performed When All Clear is executed, the parameters before program execution are initialized and Latch Clear is executed. The memory space becomes the default value, the comment area a 0 block, the file register space a 0 block, and keywords unregistered. After All Clear, set the above parameters etc. again. (WRITE mode) MODE NOP A GOStop the FX PLC MODE OK OK Cancel NOP AG O ! Caution The program will be erased. Press "OK" to continue. < WRITE > < READ > Stop the FX PLC Set the WRITE mode.
16.2 FX List Editor 16 - 33
GOT SELF CHECK (DEBUG)
16.2.14 PLC diagnostics
Displays the FX PLC error message, error code, and step at which the error occurred. ■1. Operation ■2. PLC diagnostics screen The following describes the contents displayed on the PLC diagnostics screen and the function of on-screen key. (1) Displayed contents POINTPOINTPOINT Error details For details of the FX PLC errors, refer to the following. ➠ Programming manual for the FXCPU used No. Item Display contents 1) Error message Displays the error message. (I/O configuration error/PLC hardware error/PC/HPP communication error/ Serial communication error/Parameter error/Syntax error/Circuit error/Operation error) 2) Detail Displays the error code. 3) Step Displays the step number in the sequence program at which the error occurred. (This is displayed only for a syntax error, circuit error, or operation error.) OP GO [PLC diagnostics] OP GO Select [PLC diagnostics] with or 1) 2) 3)
16 - 34 16.2 FX List Editor (2) Key function The table below shows the functions of the keys that are used for the operation on the PLC diagnostics screen. Key Function Exits the PLC diagnostics.
16.2 FX List Editor 16 - 35
GOT SELF CHECK (DEBUG)
16.2.15 Parameter setting
Sets FX PLC parameters. ■1. Parameters that can be changed and change targets (1) Parameters that can be changed The parameters that can be changed with the MELSEC-FX list editor and the target FX PLCs are as follows. : Can be set/changed : Cannot be set/changed *1 When connecting an FX0(S), set "0". Setti ng other than "0" causes a parameter error. *2 When the parameters are initialized, the display on the MELSEC-FX list editor is different from the FX PLC default values, bu t do not change the latch range. Changing the latch range causes an error. (2) Change targets When a memory cassette is mounted, the parameters in the memory cassette are targeted for changes. ■2. Operation *1 When checking parameters (not changing), it is not necessary to stop the PLC. Item Target CPU FX0(S) /FX0N FX1 FX2(C) FX1S FX1N(C) FX2N(C) FX3S FX3G(C) FX3U(C) Memory space setting File register space setting Latch range setting *2 *2 *2 RUN terminal setting Initialization of parameters Stop the FX PLC [Parameter setting] OP GO OP GO Select [Parameter setting] with or . Stop the FX PLC
16 - 36 16.2 FX List Editor ■3. Parameter setting screen The following describes the contents displayed on the PLC diagnostics screen and the function of on-screen key. (1) Displayed contents POINTPOINTPOINT (1) Memory space for kana comments after changing memory space, file register space If the memory space is set smaller than the total of the file register space and kana comment space, the kana comment space is automatically reduced. (With the MELSEC-FX list editor, the kana comment space is not displayed.) Note that if any setting as described below is made, the kana comment space is reduced. (Settings that reduce kana comment space and the kana comment space after setting change) Settings resulting in Nm < Nf 500 + Nk 500 + 500 Nm: Memory space after change (steps) Nf: File register space after change (blocks) Nk: Comment space before change (blocks) (2) Settable range and default value The settable range and the default value depend on the FX PLC type. For details of the settable range and the default value, refer to the following. ➠ Programming manual for the FX PLC used (2) Key functions The table below shows the functions of the keys that are used for the operation on the parameter setting screen. No. Item Display contents 1) Memory capacity Sets the memory space (number of steps). If you touch the section, you can change the memory space. 2) File reg. capacity Sets the memory space (number of blocks) allocated to the file register. Touch the section and input the number of blocks. 3) Latch range Sets the latch range (power failure hold area). Touch the number display section and input the value. 4) RUN terminal input Sets whether or not to use one of the FX PLC input terminals for RUN input. Touch the section and set the device to be set for the RUN terminal. 5) Default Initializes the parameters Key Function Initializes the parameters Completes the changed setting contents. Ends parameter setting. Kana comment space (steps) after setting change = 500 Nm-Nf 500-500
16.2 FX List Editor 16 - 37
GOT SELF CHECK (DEBUG)
16.2.16 Keyword
Registers, deletes, releases protection for, and sets protection for the FX PLC keywords. ■1. Function usability of the MELSEC-FX list editor for keyword protection levels The functions that can be used with the MELSEC-FX list editor depend on the keyword protection level. : Available, : Unavailable *1 When the 2nd keyword is set to an FX PLC that supports 2nd keyword, it becomes " " (cannot be used). *2 The names within the parentheses ( ) are for when a keyword + 2nd keyword is set. ■2. Operation Function Keyword protection level Reference All operation protect (All on-line operation protect)*2 Read/Incorrect write protection (Read/write protect)*2 Erroneous write prohibition (Write protect)*2 Keyword not registered/ keyword protection canceled Reading sequence programs Displaying sequence programs ➠ 16.2.8 Searching commands/devices ➠ 16.2.9 Writing sequence programs Writing commands ➠ 16.2.10 Changing operands/ set values ➠ 16.2.12 Inserting commands ➠ 16.2.10 Deleting commands ➠ 16.2.12 Sequence program all clear ➠ 16.2.13 PLC diagnostics *1 ➠ 16.2.14 Parameter setting ➠ 16.2.15 OP GO[Keyword setup] OP GO Select [Keyword setup] with or .
16 - 38 16.2 FX List Editor ■3. Keyword screen and protection level When [Keyword setup] is selected with the MELSEC-FX list editor, the keyword screen is displayed. For the keyword operation, refer to the following. ➠ 11.6 Keyword POINTPOINTPOINT Keywords For details of the keyword, refer to the following. ➠ Programming manual for the FX PLC used
16.2 FX List Editor 16 - 39
GOT SELF CHECK (DEBUG)
16.2.17 List monitor
The status of contacts and coils in a sequence program is displayed. ■1. Operation POINTPOINTPOINT Starting list monitor with special function switches (FX list monitor) With setting special function switches (FX list monitor), the list monitor can be started on the monitor screen. When the list monitor is started on the monitor screen, the list editor cannot be used. For how to set special function switches, refer to the following. ➠ GT Designer3 (GOT2000) Help OP GO[ List Monitor ] OP GO Select [List Monitor] with or . When the list monitor is started on the FX list editor screen, the step numbers displayed on the FX list editor screen is displayed on the list monitor screen.
16 - 40 16.2 FX List Editor ■2. Displays and key functions The following describes the displays for the list monitor. *1 The status of contacts and coils is displayed as below.
16.2.18 Action for an incorrect key input
If an incorrect key is input, cancel the input contents. ■1. Operations (1) Before touching the key (before reading/writing the input contents) Before touching the key, touch the key. (2) After touching the key (after reading/writing the input contents) Write the command again. ➠ 15.3.10 Writing commands Commands finalized by writing and inserting operations are revised (overwritten) with the program writing. No. Item Display contents 1) List display area*1 The status of contacts and coils is displayed on the left of device displays. 2) Keys The same operations as in the READ mode of the FX list editor can be executed. ➠ 16.2.8 Displaying sequence programs 3) [] Ends the list monitor. (When the list monitor is executed on the FX list editor screen, the screen is switched to the FX list editor screen.) Type of instruction Description Status ■ Displayed ■ Not displayed LD, AND, OR (Contact instruction (Normal open)) Contact ON OFF LDI, ANI, ORI (Contact instruction (Normal close)) Contact OFF ON OUT, SET TC: Coil ON OFF Except TC: Contact ON OFF RST TC: Reset ON OFF Word device Value: 0 Value: Except 0 Except TC and word device: Contact OFF ON MC, STL Contact ON OFF LDP, ANDP, ORP, LDF, ANDF, ORF (Rise or fall contact instruction) Not monitored Always ■ not displayed GO GO CLR GO
16.2 FX List Editor 16 - 41
GOT SELF CHECK (DEBUG)
16.2.19 Error messages a nd corrective actions
This section describes the error messages displayed when the MELSEC-FX list editor is executed, and corrective action. POINTPOINTPOINT How to erase an error message An error message is not erased even if the cause of the error is eliminated. To erase an error message, touch a key on the MELSEC-FX list editor screen. Error message Description Corrective action Can not display while protected. The all-operation protect, anti- plagiarism, or incorrect write protect keyword is set.
- Check the protected operation.
- Clear the keyword protection or delete the keyword. ➠ 16.2.16 KeywordCan not operate while protected. PLC parameter error. An FX PLC parameter is def ective. Set correct parameters in the FX PLC. PLC communications error. The communication with the FX PLC is defective.
- Check the FX PLC, cable, and GOT for abnormality.
- Check whether the communication settings are correct or not. PLC is running. A writing operation etc. has been made while the FX PLC is running. Stop the FX PLC. Can not write.
- The memory to write to is EPROM.
- The protect switch of the EEPROM is on.
- Set other than EPROM for the memory to write to.
- Switch off the protect switch of the EEPROM. Step number is out of a range. The specified step number exceeded the maximum number. Specify a step number below the maximum value. Not found. The specified command cannot be found. Proceed to the next operation. Not found. The specified device cannot be found. Proceed to the next operation. Step overflow. The program may exceed the available space. (Writing is not executed.) Check the program memory space and delete commands to keep it within the space. ➠ 16.2.12 Deleting commands Command error. An invalid command (non-existent command) was specified. Input the correct command.
16 - 42 16.3 FX3U-ENET-ADP Communication Setting Function
16.3 FX3U-ENET-ADP Communication Setting Function
In GX Works2, the communication set value of the FX3U-ENET-ADP stored in the CPU can be changed. This function is not available when the communication set value of the FX3U-ENET-ADP is not set in advance in the CPU. POINTPOINTPOINT Communication setting in the CPU In GX Works2, set in advance the communication set value of the FX3U-ENET-ADP to the CPU. For the details of the communication setting, refer to the following. ➠ FX3U-ENET-ADP User's manual
16.3.1 Specifications
■1. System configuration This section describes the system configuration of the FX3U-ENET-ADP communication setting function. For the setting method in each connection form, used communication unit/cable and cautions on connection form, refer to the following manual. ➠ GOT2000 Series Connection Manual For GT Works3 Version1 ■2. Required basic system application ■3. Connection type ( : Applicable, : Partly restricted, : Inapplicable) ■4. Communication setting items The table below shows the communication setting items and setting range. *1 Set the value "0.0.0.0" when not using the subnet mask pattern and default router IP address. Operating system Version Basic system application - Communication driver MELSEC-FX - Function Connection type between GOT and controller Name Description Direct CPU connection GOT multidrop connection FX3U-ENET-ADP communication setting function The communication set value of the FX3U-ENET-ADP stored in the CPU can be changed.Communication setting items Setting range Remark If a value outside the setting range is entered, the error
16.3 FX3U-ENET-ADP Communication Setting Function 16 - 43
GOT SELF CHECK (DEBUG)
16.3.2 Display operation of FX3U-ENET- ADP communication setting function
When the communication set value of the FX3U-ENET-ADP is stored in the CPU Touch [FX3U-ENET-ADP] Channel Setting Touch [OK] Touch [×] Touch [Debug] Touch [OK]
16 - 44 16.3 FX3U-ENET-ADP Communication Setting Function
16.3.3 Setting operation
Step 1. Touch the numerical part of the octet to be changed among the 1st to 4th octets. Step 2. When the ten-key pad appears, enter a numerical value in up to 3 digits, and touch the key. If a numerical value outside the setting range is entered, the following error message appears. Enter a numerical value again. For the details of the setting range, refer to the following. ➠ 16.3.1 Specifications Step 3. The changed IP address is displayed. At this time, the changed communication set value of the FX3U-ENET-ADP is not written to the CPU. Touch the [ ] key. Step 4. When the screen shown on the left appears, touch the key. Continued to next page Touch the numerical part of the octet to be changed. Touch Touch[×] Touch [YES]
16.3 FX3U-ENET-ADP Communication Setting Function 16 - 45
GOT SELF CHECK (DEBUG) Step 5. When the screen shown on the left appears, the changed communication set value of the FX3U-ENET-ADP is written normally to the CPU. For making valid the contents of setting, turn OFF the power of the CPU, and then turn it ON again. Change the setting of the subnet mask pattern and default router IP address using the same procedure if necessary. An error message appears in the following cases. Touch the key to return to the step 1., and perform the setting procedure again.
- When the CPU is running The following error message appears. Stop the running status of the CPU.
- When a communication error occurs Set the communication between the GOT and the CPU to the normal status.
- When the memory cassette is write- protected Set to OFF the write-protect switch of the memory cassette.
- When writing to the CPU is protected by the keyword Clear the protection by the keyword against writing.
16 - 46 16.3 FX3U-ENET-ADP Communication Setting Function POINTPOINTPOINT When the CPU stores the symbolic information When the setting such as IP address is changed using this function and then the program is read by the programming tool from the CPU that stores the symbolic information, the following warning appears. However, the changed value is read correctly. Convert and compile the project again.
17.1 Touch Panel Calibration 17 - 1
- MAINTENANCE
17.1 Touch Panel Calibration
■1. Touch panel calibration setting function Touch panel reading error can be corrected. Normally the adjustment is not required, however, the difference between a touched position and the object position may occur as the period of use elapses. When any difference between a touched position and the object position occurs, correct the position with this function. ■2. Touch panel calibration setting display operation Run Stop Run Stop Before adjustment After adjustment The [Run] will operate though you intended to touch the [Stop] button. The [Stop] button can be touched without fail. Main Menu Maintenance Calibration Touch [Maintenance]. Touch [Calibration].
17 - 2 17.1 Touch Panel Calibration ■3. Touch panel calibration operation Touch [+] displayed on the screen with the finger one by one to make the setting. Step 1. Touch the center of [+] displayed on the upper left precisely. Step 2. Touch [+] displayed on the upper left. Step 3. Touch [+] displayed on the upper right. Step 4. Touch [+] displayed on the lower right. Step 5. When the precise touch could not be made, touch the [YES] button to make the setting from Step1 again.
17.2 Touch Panel Check 17 - 3
17.2 Touch Panel Check
■1. Touch panel check function Touch panel check function checks whether there is no dead zone area of 2 dots 2 dots. ■2. Display operation of Touch panel check POINTPOINTPOINT Notes on Touch panel check If the touched part is not filled with yellow color, there are the following two possible causes. 1. Display part failure 2. Touch panel failure In that case, contact your local Mitsubishi (Electric System) Service. Main Menu Maintenance Panel check Touch [Maintenance]. Touch [Panel check].
17 - 4 17.2 Touch Panel Check ■3. Touch panel check operations If touch [Panel check] of self-check, a black-filled screen is displayed over the entire screen area. POINTPOINTPOINT Checking the upper left part of the screen Only the upper left part of the screen cannot be filled with yellow. If the screen returns to the self-check by touching the upper left part, judge that the upper left area operates normally. Step 1. Touch a part of the screen. The touched part becomes a yellow- filled display. Up to 40 parts becomes yellow-filled displays.Step 2. If [ ] on the upper right is touched, the screen returns to the self-check. Black-filled screen Yellow color
17.3 Clean 17 - 5
17.3 Clean
In utility, the screen can be set as not to be effected by touching the screen when clean with clothes. For cleaning method, refer to the following. ➠ 20.3 Cleaning Method ■1. Display operation of clean ■2. Display operation of clean For details of cleaning method, refer to the following. ➠ 20.3 Cleaning Method Step 1. Touching the [ ] key closes the screen. Even if touch points other than the upper left corner and upper right corner of the screen, the GOT does not operates. Main Menu Maintenance Clean Touch [Maintenance]. Touch [Clean]. Touch
17 - 6 17.3 Clean
18.1 Installation Method When the GOT is Turned On 18 - 1
INSTALLING PACKAGE DATA BY USING AN SD CARD 18. INSTALLING PACKAGE DATA BY USING AN SD CARD The package data stored in an SD card can be installed to the GOT by performing the following procedure. For storing method of the package data to an SD card, refer to the following. ➠ GT Designer3 (GOT2000) Help
18.1 Installation Me thod When the GOT is Turned On
■1. Operation procedure Step 1. Power OFF the GOT, and attach the SD card which stores the basic system application and communication driver to the GOT. Step 2. While touching the upper left corner of the GOT screen, power ON the GOT.Step 3. When the screen shown on the left appears, select the [Data copy]. For details of install, refer to the following. ➠15.7 Data Copy Touch [Data copy].
18 - 2 18.1 Installation Method When the GOT is Turned On
19.1 BootOS and Basic System Application to be Installed 19 - 1
INSTALLATION OF BOOTOS AND BASIC SYSTEM APPLICATION 19. INSTALLATION OF BOOTOS AND BASIC SYSTEM APPLICATION To execute the GOT utility, install the BootOS and system applications on the C drive (built-in flash memory) of the GOT, or set the boot drive of the package data to [A: Standard SD card] and insert an SD card with the package data into the GOT. (BootOS is installed in the GOT at factory shipment. It is not necessary to install BootOS when upgrading of it is unnecessary.) This chapter explains the installation using GOT. Refer to the following for the installation which uses GT Designer3. ➠ GT Designer3 (GOT2000) Help
19.1 BootOS and Basic System Application to be Installed
Under-mentioned BootOS and basic system application are necessary to execute utility. System application name Function overview BootOS Required for the control of GOT and the communication between PC and GOT. Installed at factory shipment. (BootOS can also be installed from GT Designer3. When BootOS is installed, the GOT is initialized and goes to the status at factory shipment. When BootOS needs to be reinstalled, the basic system application has to be installed in the GOT.) System application Required for the GOT operation as the monitoring function of GOT, installation and deletion of the system application or project data, touch key control or display function of the screen and guidance. Required for display and operation of the user-created screen and utility screen. Not installed in GOT at factory shipment. Install it from GT Designer3 or an SD card. The GOT can starts without a package data installed. Install the SD card in GOT Set the OS boot drive to [A: Standard SD card]. Install the SD card in GOT SD card Install from GOT to GOT using a SD card. SD card Package data install GOT GT Designer3 SD card GOT GOT SD card GOT Write package data Package data upload GT Designer3 GOT GOT
19 - 2 19.2 Prior Preparations for Installing BootOS and System Application
19.2 Prior Preparations for Installin g BootOS and System Application
For the installation using GOT, the data storage that is storing BootOS or the system application is required. There are the following three methods for the installation of BootOS and system application. (1) [To Memory Card] from GT Designer3 ➠ GT Designer3 (GOT2000) Help (2) Uploading from another GOT (the package data has been installed) ➠ 18. INSTALLING PACKAGE DATA BY USING AN SD CARD (3) Using an SD card that stores data with OS boot drive set to A drive ➠ GT Designer3 (GOT2000) Help POINTPOINTPOINT Precautions when installing BootOS and the package data into an SD card When installing BootOS and the package data into the SD card, be sure to execute by the utility of another GOT or GT Designer3. The installation is not executed properly with the SD card to which data is uploaded from the utility of GOT or copied by software other than GT Designer3. Note the available capacity of the SD card. The available capacity of BootOS and system applications can be confirmed by [To Memory Card] or [Write Option] of GT Designer3. Write Option Available space of the data Available space of the system application
MAINTENANCE AND INSPECTION 20. MAINTENANCE AND INSPECTION The GOT does not include consumable components that will cause the shorten life. However, the liquid crystal screen and backlight have life length. For the life of the LCD screen or backlight, refer to the following. ➠ 3.2 Performance Specifications STARTUP AND MAINTENANCE PRECAUTIONS WARNING
- When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction.
- Connect the battery correctly. Do not discharge, disassemble, heat, short, solder or throw the battery into the fire. Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires.
- Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases. Not doing so can cause the unit to fail or malfunction. Undertightening can cause a short circuit or malfunction. Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit. STARTUP AND MAINTENANCE PRECAUTIONS CAUTION
- Do not disassemble or modify the unit. Doing so can cause a failure, malfunction, injury or fire.
- Do not touch the conductive and electronic parts of the unit directly. Doing so can cause a unit malfunction or failure.
- The cables connected to the unit must be run in ducts or clamped. Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
- When unplugging the cable connected to the unit, do not hold and pull from the cable portion. Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
- Before touching the unit, always touch grounded metals, etc. to discharge static electricity from human body, etc. Not doing so can cause the unit to fail or malfunction. DISPOSAL PRECAUTIONS CAUTION
- When disposing of this product, treat it as industrial waste.
20 - 2 20.1 Daily Inspection
20.1 Daily Inspection
■1. Daily inspection items
20.2 Periodic Inspection
■1. Yearly or half-yearly inspection items The following inspection should also be performed when equipment has been moved or modified or the wiring changed. Item Inspection Item Inspection Method Criterion Corrective action
1 GOT mounting status Check for loose
mounting screws. Securely mounted Retighten screws within the specified torque range
2 Connection
screwdriver Not loose Retighten terminal screws Proximate solderless terminals Visual check Proper space Correction Loose connectors Visual check Not loose Retighten connector fixing screws
3 Usage
attachment Visual check No foreign matter sticking Remove, clean Item Inspection Item Inspection Method Criterion Action
1 Surrounding
temperature Make measurement with thermometer or hygrometer. Measure corrosive gas. 0 to 50°C For use in control panel, temperature inside control panel is ambient temperature Ambient humidity 10 to 90%RH Atmosphere No corrosive gas
2 Power supply voltage check 24VDC Measure voltage across
terminals. 20.4 to 26.4VDC Change supply power
3 Mounting
Looseness Move module Should be mo unted firmly Retighten screws Foreign material attachment Visual check No foreign ma tter sticking Remove, clean
4 Connection
screws Retighten screws with screwdriver Not loose Retighten terminal screws Proximate solderless terminals Visual check Proper space Correction Loose connectors Visual check Not loose Retighten connector fixing screws
20.3 Cleaning Method 20 - 3
MAINTENANCE AND INSPECTION
20.3 Cleaning Method
Use the GOT always in a clean condition. To clean the GOT, wipe the dirty part with a soft cloth using neutral detergent. For the display operation of the [Clean] screen, refer to the following. ➠ 17.3 Clean POINTPOINTPOINT Precautions for cleaning Do not use chemicals such as thinner, organic solvents and strong acids, since they may cause the protective sheet to be deformed or the dissolvable paint on the surface to peel off. In addition, do not use spray solvents since they may cause the electrical failure of the GOT and peripheral devices. Clean
20 - 4 20.4 Backlight Shutoff Detection
20.4 Backlight Shutoff Detection
A GOT has a built-in backlight for the liquid crystal display. When a GOT detects the backlight shutoff, the POWER LED alternately flashes with orange/green color. The brightness of the backlight degrades as the usage period passes. Replace the backlight when it is shut off or the display gets blurry. For the replacement of the backlight, contact your local distributor. (1) Backlight life The usage period of the backlight can be extended by setting [Screen saving backlight off] in the GOT utility function (GOT setup). For details, refer to the following. ➠ 12. DISPLAY AND OPERATION SETTINGS (GOT SET UP)
20.4.1 Backlight shutoff detect ion and external alarm
When the GOT has detected that the backlight is shut off, the system information set by using drawing software is turned on. The information of the backlight shutoff can be output from a PLC to an external device (such as lamp and buzzer) by using the system information. An alarm for prevention of touch operation should be set and the external interlock should also be set for the dangerous load. For system information details, refer the following. ➠ GT Designer3 (GOT2000) Help POINTPOINTPOINT (1) Example of alarm for external devices (such as lamp and buzzer) System information is used to output the backlight shutoff detection signal from a FX series PLC to an external device. Condition: The write device is D20 and all data is used (the [Select All] button on the setting screen of drawing software is clicked) for the system information assignment. D36 b14: Backlight shutoff detection (System number 2-2) This signal turns on when the backlight shutoff is detected. This signal is used in a sequence programs shown below. (2) Caution when the b acklight is shut off Even when the backlight is shut off, the touch keys are available. Replace the dead backlight as soon as possible. M34 Output to external device of PLC Activated the output upon battery shutoff detection. Backlight shutoff detection M8000 MOV D36 K4M20 RUN monitor Y*** *indicates the output number at which the external device is connected.
21.1 GOT Restoration Sheets 21 - 1
- TROUBLESHOOTING This chapter describes the GOT restoration sheets and the lists of error messages and system alarms.
21.1 GOT Restoration Sheets
This section describes how to restore the GOT that operates improperly in the check sheet format. The following describes how to use each sheet. (1) When the GOT does not operate or operates improperly (GOT status check sheet) When the GOT does not operate or operates improperly, check the cause of a malfunction by following the GOT status check sheet and take corrective actions. After the GOT is restored, see how the GOT works. (2) When wiring needs to be modified (GOT installation status check sheet) When the check (1) is performed and then noise and other failures generated by improper wiring of the GOT are considered as the cause of the malfunction, modify the wiring by following the GOT installation status check sheet. After the GOT is restored, see how the GOT works. (3) When corrective actions other than the above (1) and (2) are required (System configuration check sheet) If the GOT still does not operate or operates improperly even though the check (1) and (2) are performed and the corrective actions are taken, write the system configuration used on the system configuration check sheet and contact your local distributor. When sending the actual product, attach the GOT restoration sheets (GOT status check sheet, GOT installation status check sheet, and System configuration check sheet) which are checked in this section. Keep a copy of each sheet.
21 - 2 21.1 GOT Restoration Sheets ■1. GOT status check sheet Start the check from (1) GOT status. Follow the instructions in the corrective action column. (1) GOT status Phenomenon Cause/Status Corrective action (a) Frequency of a case where the GOT does not operate or the screen is not displayed properly Always Frequency: ( ) Example: Once a month Go to (1)-(b). Sometimes (b) The display of an error code (system alarm) Can be confirmed Error code (system alarm): ( ) Example: 460 Communication unit error Take corrective actions for the confirmed error code (system alarm) and error message. If the status does not change even after the corrective actions are taken, go to (1)-(c). Cannot be confirmed Go to (1)-(c). (c) Screen display The screen is entirely black. The possible cause is a failure of the liquid crystal or an error of the BootOS. Take corrective actions in the following order. 1) Re-install the BootOS. 2) Re-install the standard monitor OS. When the GOT is still not restored after Action 1) and 2) are taken, perform the following. 3) Re-install the CoreOS and the standard monitor OS in this order. If the GOT is still not restored, go to (5) Actual product investigation. The screen is entirely white. The possible cause is a hardware failure of the GOT. Go to (5) Actual product investigation. A line appears on the screen. The possible cause is a hardware failure of the GOT. Example: A vertical line appears on the screen. Go to (5) Actual product investigation. Other display errors The screen is frozen. The screen display is not updated and the screen cannot be operated. Go to (1)-(e). (d) Buzzer sound No buzzer sound Buzzer sound: ( ) Example: The buzzer repeats in the rhythm of "beep-beep-beep, beep, beep-beep". Go to (2) Status where the GOT screen is frozen. Beeps randomly Beeps in a pattern Beeps without a pause The possible cause is the activated buzzer output signal. When the reading device of the system information is set, the device may be turned on and the buzzer output signal may be activated. Check the setting of the reading device. When the buzzer output signal has no error, proceed to (2) Status where the GOT screen is frozen.
21.1 GOT Restoration Sheets 21 - 3
(2) Status where the GOT screen is frozen (When the screen operation stops) (3) PLC CPU status Phenomenon Cause/Status Corrective action (a) Switching to the utility Enabled Error code (system alarm): ( ) Example: 460 Communication unit error When the system alarm display function can be used, take corrective actions for the displayed error code (system alarm). Otherwise, go to (2)-(b). Disabled The system alarm display function cannot be used. Go to (2)-(c). (b) I/O check with the utility of the GOT Communication fault Display contents: ( ) Example: A message that indicates the possible cause is a connection failure is displayed. Go to (2)-(c). No error Hardware such as the communication interface has no error. Go to (3) PLC CPU status. (c) Objects that are not displayed on the monitor screen Exists Detail: ( ) Example: The numerical display is not displayed. Go to (3) PLC CPU status. None Phenomenon Cause/Status Corrective action (a) PLC error Always The possible cause is CONTROL-BUS. ERROR, SP. UNIT LAY. ERROR, or other errors. Error code (system alarm): ( ) Example: 1204 CPU H/W fault Go to the following. ➠ 21.1 Sometimes The possible cause is noise or a hardware failure. Frequency: ( ) Example: Once a month Error code (system alarm): ( ) Example: 1204 CPU H/W fault Go to (4) GOT restoration procedure. Normal operation -
21 - 4 21.1 GOT Restoration Sheets (4) GOT restoration procedure Follow the procedures in order from (a) and check if the GOT is restored. If the GOT is still not restored, go to the next step. *1 Before powering on the GOT again (OFF ON), make sure to power off the PLC. (5) Actual product investigation When the GOT still operates improperly even after the corrective actions described above are taken, contact your local distributor. Depending on the error status, the actual product may need to be returned to us. In that case, attach the GOT status check sheet, GOT installation status check sheet, and system configuration check sheet (Write down your system configuration used on the sheet). Check item Cause Corrective action (a) The GOT is restored by using the reset switch on the GOT. Restored Not restored (Go to (b).) It may be a temporary malfunction due to noise. Take the corrective action described in (4)- (h). (b) The GOT is restored by powering on and off the GOT. Restored Not restored (Go to (c).) (c) The GOT is restored by resetting or powering on and off the PLC CPU. Restored Not restored (Go to (d).) (d) The GOT is restored by powering on and off the GOT and the PLC CPU simultaneously. Restored Not restored (Go to (e).) (e) The GOT is restored by reconnecting cables. Restored Not restored (Go to (f).) The possible cause is a cable connection fault. Connect cables securely. When the error occurs again, go to (5) Actual product investigation. (f) The GOT is restored by reinstalling project data. Restored Not restored (Go to (g).) In such a case where the GOT is powered off during installation of project data or OS, the data may be corrupted. Do not power off the GOT during data transmission. When the error occurs again, go to (5) Actual product investigation. (g) The GOT is restored by reinstalling OS. Restored Not restored (Go to (h).) (h) The GOT is restored by taking corrective actions against noise described in the corrective action column. Restored Not restored (Go to (i).) It may be a temporary malfunction due to noise. Take corrective actions by following the GOT installation status check sheet. (i) The GOT is not restored even after the corrective actions in (a) to (h) are taken. - Go to (5) Actual product investigation.
21.1 GOT Restoration Sheets 21 - 5
■2. GOT installation status check sheet Check the actual installation status of the GOT used according to the GOT installation status described in the upper rows of items (1) to (7). When the corrective actions described in the lower rows need to be taken, take the actions. Only when the corrective actions are taken, put a check mark in the check box of "Effective" or "Ineffective" depending on the results of the actions. (1) Wiring inside (2) Outside the panel Actual status Power lines such as power supply cables or servo amplifier drive cables and communication cables are crossed each other in the wiring duct in the control panel. Crossed Not crossed Corrective action for when the cables are crossed each other Wiring the power lines and the communication cables to keep them away from each other in the control panel will help minimize noise interference. Effective Ineffective Actual status Power lines and communication cables are bundled together. Bundled Not bundled Corrective action for when they are bundled Figur e A Setting outlets of the power lines and the communication cables separately, as shown in Figure A, will help minimize noise interference. In the duct, keeping the communication cables away from the power lines or using a metal separator, as shown in Figure B, can reduce noise interference. Effective IneffectiveFigur e B NFB MC MC RA RA NFB MC MC RA RA Power line Communication cable Communication cable Power line Power line Wiring duct Separator Power line Signal line Communication cable 100mm or more
21 - 6 21.1 GOT Restoration Sheets (3) Wiring of the GOT's FG cables and power lines (4) Countermeasures to prevent surges Entry columns for surge suppressors Actual status The GOT's FG cables and power lines are bundled together. Bundled Not bundled Corrective action for when they are bundled Keeping the GOT's FG cables and power lines away from each other will help minimize noise interference. Effective Ineffective Actual status Surge suppressors are used for wiring equipment (loads) such as no fuse breakers, electromagnetic contactors, relays, solenoid valves, and induction motors. (When surge suppressors are used, write their models and the names of devices for which the surge suppressors are used in the following table.) Used Not used Corrective action for when surge suppressors are not used Using surge suppressors on the wiring near loads can reduce interference of the GOT surge. Effective Ineffective Model of surge suppressor Device for which the surge suppressor is used GOT FG Power for the power equipment FG Power for the power equipment GOT AC C LROutput PLC AC C LROutput PLC The surge suppressor must be attached close to the load
21.1 GOT Restoration Sheets 21 - 7
(5) Installation status Actual status The FG cables of control equipment (such as a PLC) and power equipment (such as a servo amplifier) are connected each other as shown in a. True False Corrective action for when it is true Figure A Carry out the independent grounding at two points as shown in Figure A. Independent grounding will help minimize noise interference. If the independent grounding is impossible, carry out the shared grounding as shown in Figure B. Effective Ineffective Figure B GOT FG Connection cable Panel grounding Panel grounding FG FG CN1BCN1A CN3 CN2 LG a PLCServo FG Connection cable Panel grounding Grounding for power system Grounding for power system Terminal block Terminal block FG FG CN1BCN1A CN3 CN2 LG PLCServo GOT FG Connection cable Panel grounding Panel grounding FG FG CN1BCN1A CN3 CN2 LG PLCServo GOT
21 - 8 21.1 GOT Restoration Sheets (6) Grounding status of the control panel where the GOT is installed Actual status A ground cable is led from the control panel where control equipment such as a PLC is installed to the control panel where the GOT is installed. True False Corrective action for when it is true Figure A Connecting a ground cable to the panel where the GOT in installed as shown in Figure A reduces electric potential difference between the ground points, which may avoid malfunction of the GOT. If the wiring shown in Figure A cannot be carried out, perform the wiring as shown in Figure B. Effective Ineffective Figure B Figure C Attaching a ferrite core to the ground cable connected to the control panel where the GOT is installed, as shown in Figure C, will help minimize noise interference. If the wiring shown in Figure C cannot be carried out, perform the wiring as shown in Figure D. Effective Ineffective Figure D Connection cable GOT FG Ground cable led from the panel having the control equipment GOT Ground to the panel. Ground cable Use a short and thick wire as possible. FG Connection cable GOT Ground to the panel. Ground cable FG Connection cable GOT Ground to the panel. Ferrite coreGround cable FG Connection cable Use a short and thick wire as possible. GOT Ground to the panel. Ground cable FG Connection cable Ferrite core
21.1 GOT Restoration Sheets 21 - 9
(7) Power supply system Actual status I/O equipment (such as a relay) and power equipment (such as a servo amplifier) use the power supply in the same system as the one of the GOT. True False Corrective action for when it is true Carry out the wiring with the power supply of the GOT separated from the one of the I/O equipment and power equipment and connect an isolation transformer. This will help minimize noise interference. Effective Ineffective Main power AC200V PLC power I/O power I/O equipment PLC GOT Main circuit power Power equipment Main power AC200V PLC power I/O power I/O equipment Isolation transformer PLC GOT Main circuit power Power equipment
21 - 10 21.1 GOT Restoration Sheets ■3. System configuration check sheet Write the model of each unit in the following square brackets ([ ]). (1) System configuration of the GOT (a) GOT [ ] (b) Communication interface [ ] (c) Cable between the PLC and GOT [ ] (d) Cable length [ m] (2) System configuration of the PLC (a) Power supply unit [ ] (b) CPU module [ ] (c) Serial communication unit /computer link unit Used [ ] Not used (d) Network unit Used [ ] Not used (e) Interrupt module Used [ ] Not used (f) Positioning module Used [ ] Not used (g) Number of extended PLC stages [ stages ] (h) When other units or devices are used, write their names. Entry column for writing the status of the phenomenon (when the GOT still operates improperly after corrective actions are taken) (3) Write the details of the error operations. (Such as when the GOT screen is frozen or the screen is displayed improperly)
22.1 Connecting to Mitsubishi Products 22 - 1
- CONNECTION This chapter describes connection types which are supported by GOT SIMPLE series. In each reference manual, two icons, and , are given in this manual. refers to the connection types supported by the GOT SIMPLE series. refers to the connection types unsupported by the GOT SIMPLE series. For the connectors on the GOT side, refer to the following. ➠ 3.4 GOT Connector Specifications
22.1 Connecting to Mitsubishi Products
The following connection types are supported.
22.1.1 Ethernet connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 5. ETHERNET CONNECTION
22.1.2 Direct CPU connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 6. DIRECT CONNECTION TO CPU
22.1.3 Computer link connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 7. COMPUTER LINK CONNECTION
22.1.4 CC-Link connection (via G4)
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 13. CC-Link CONNECTION (Via G4)
22.1.5 Inverter connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 14. INVERTER CONNECTION
22.1.6 Servo amplifier connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 15. SERVO AMPLIFIER CONNECTION
22.1.7 Multi-channel function
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 19. Multi-channel Function
22.1.8 FA transparent function
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Mitsubishi Product) For GT Works3 Version1 20. FA TRANSPARENT FUNCTION
22 - 2 22.2 Connecting to Non-Mitsubishi Products
22.2 Connecting to Non-Mitsubishi Products
22.2.1 Connecting to SIEMENS PLC
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Non Mitsubishi Product 2) For GT Works3 Version1 14. CONNECTION TO SIEMENS PLC
22.3 Connecting to Peripheral Devices
22.3.1 Bar code reader connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT Works3 Version1 8. BAR CODE READER CONNECTION
22.3.2 Printer connection
For details, refer to the following. ➠ GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT Works3 Version1 14. PRINTER CONNECTION
- APPENDIX Appendix.1 External Dimensions ■1. GS2110-WTBD Unit: mm (inch) M2.6 (Metric screw thread) #4-40UNC (Inch screw thread) 272(10.71") 56(2.21") 35(1.38") 6(0.24") 214(8.43") 151(5.95") 197(7.76") 257(10.12") The thickness of the panel face is 1.6 to 4mm. 197(7.76")
■2. GS2107-WTBD Unit: mm (inch) 10(0.4")10(0.4") 144(5.67") 206(8.12") 155(6.11") 190(7.49") The thickness of the panel face is 2 to 4mm. 136(5.36") 112(4.41") 50(1.97") 26(1.03") M2.6 (Metric screw thread) #4-40UNC (Inch screw thread) 144(5.67")
■3. Communication cable value L length (mm (inch)) 100 10000 (393.7") 200 20000 (787.4") 300 30000 (1181.1") value L length (mm (inch)) 10 1000 (39.37") 30 3000 (118.11") 100 10000 (393.7") 200 20000 (787.4") 300 30000 (1181.1") 30000(1181.11") 55(2.17") 16(0.63")16(0.63") 35(1.38") M2.6 M2.6 (0.28") L 55(2.17") 16(0.63")16(0.63") 35(1.38") M2.6 M2.6 (0.28") GT01-C30R4-25P GT01-C R4-25P Unit: mm (inch) L 40(1.58") Φ13 Φ25×33 (0.52") M2.6 50(1.97")16(0.63") 35(1.38") GT01-C R4-8P Unit: mm (inch)
#4-40UNC M2.6 55(2.17") 16(0.63")16(0.63") 35(1.38") (0.24") #4-40UNC #4-40UNC 35(1.38") 35(1.38") (0.24") Φ13 #4-40UNC Φ20×28 35(1.38") 40(1.58") (0.52") GT01-C30R2-25P GT01-C30R2-9S GT01-C30R2-6P Unit: mm (inch)
- The manual number is given on the bottom left of the back cover. © 2013 MITSUBISHI ELECTRIC CORPORATION Print Date * Manual Number Revision Jan., 2014 JY997D52901A First printing This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
Please confirm the following product warranty details before using this product. 1. Gratis Warranty Term and Gratis Warranty Range If any faults or defects (hereinafter "Failure") found to be the responsibility of Mitsubishi occurs during use of the product within the gratis warranty term, the product shall be repaired at no cost via the sales representative or Mitsubishi Service Company. However, if repairs are required onsite at domestic or overseas location, expenses to send an engineer will be solely at the customer's discretion. Mitsubishi shall not be held responsible for any re-commissioning, maintenance, or testing on-site that involves replacement of the failed module. [Gratis Warranty Term] The gratis warranty term of the product shall be for thirty-six (36) months after the date of purchase or delivery to a designated place. Note that after manufacture and shipment from Mitsubishi, the maximum distribution period shall be six (6) months, and the longest gratis warranty term after manufacturing shall be forty-two (42) months. The gratis warranty term of repair parts shall not exceed the gratis warranty term before repairs. [Gratis Warranty Range] (1) The customer shall be responsible for the primary failure diagnosis unless otherwise specified. If requested by the customer, Mitsubishi Electric Corporation or its representative firm may carry out the primary failure diagnosis at the customer’s expence. The primary failure diagnosis will, however, be free of charge should the cause of failure be attributable to Mitsubishi Electric Corporation. (2) The range shall be limited to normal use within the usage state, usage methods and usage environment, etc., which follow the conditions and precautions, etc., given in the instruction manual, user's manual and caution labels on the product. (3) Even within the gratis warranty term, repairs shall be charged for in the following cases. 1. Failure occurring from inappropriate storage or handling, carelessness or negligence by the user. Failure caused by the user's hardware or software design. 2. Failure caused by unapproved modifications, etc., to the product by the user. 3. When the Mitsubishi product is assembled into a user's device, Failure that could have been avoided if functions or structures, judged as necessary in the legal safety measures the user's device is subject to or as necessary by industry standards, had been provided. 4. Failure that could have been avoided if consumable parts designated in the instruction manual had been correctly serviced or replaced. 5. Replacing consumable parts such as the battery, backlight and fuses. 6. Failure caused by external irresistible forces such as fires or abnormal voltages, and Failure caused by force majeure such as earthquakes, lightning, wind and water damage. 7. Failure caused by reasons unpredictable by scientific technology standards at time of shipment from Mitsubishi. 8. Any other failure found not to be the responsibility of Mitsubishi or that admitted not to be so by the user. 2. Onerous repair term after discontinuation of production (1) Mitsubishi shall accept onerous product repairs for seven (7) years after production of the product is discontinued. Discontinuation of production shall be notified with Mitsubishi Technical Bulletins, etc. (2) Product supply (including repair parts) is not available after production is discontinued. 3. Overseas service Overseas, repairs shall be accepted by Mitsubishi's local overseas FA Center. Note that the repair conditions at each FA Center may differ. 4. Exclusion of loss in opportunity and secondary loss from warranty liability Regardless of the gratis warranty term, Mitsubishi shall not be liable for compensation to damages caused by any cause found not to be the responsibility of Mitsubishi, loss in opportunity, lost profits incurred to the user by Failures of Mitsubishi products, special damages and secondary damages whether foreseeable or not, compensation for accidents, and compensation for damages to products other than Mitsubishi products, replacement by the user, maintenance of on-site equipment, start-up test run and other tasks. 5. Changes in product specifications The specifications given in the catalogs, manuals or technical documents are subject to change without prior notice. 6. Product application (1) In using the Mitsubishi graphic operation terminal, the usage conditions shall be that the application will not lead to a ma jor accident even if any problem or fault should occur in the graphic operation terminal device, and that backup and fail-safe functions are systematically provided outside of the device for any problem or fault. (2) The Mitsubishi graphic operation terminal has been designed and manufactured for applications in general industries, etc. Thus, applications in which the public could be affected such as in nuclear power plants and other power plants operated by respective power companies, and applications in which a special quality assurance system is required, such as for Railway companies or Public service purposes shall be excluded from the graphic operation terminal applications. In addition, applications in which human life or property that could be greatly affected, such as in aircraft, medical applications, incineration and fuel devices, manned transportation equipment for recreation and amusement, and safety devices, shall also be excluded from the graphic operation terminal range of applications. However, in certain cases, some applications may be possible, providing the user consults the local Mitsubishi representative outlining the special requirements of the project, and providing that all parties concerned agree to the special circumstances, solely at our discretion. In some of three cases, however, Mitsubishi Electric Corporation may consider the possibility of an application, provided that the customer notifies Mitsubishi Electric Corporation of the intention, the application is clearly defined and any special quality is not required.
GOT is a registered trademark of Mitsubishi Electric Corporation. Microsoft, Windows, Windows NT, Windows Server, Windows Vista, and Windows 7 are registered trademarks or trademarks of Microsoft Corporation in the United States and other countries. Adobe and Adobe Reader are registered trademarks of Adobe Systems Incorporated. Pentium and Celeron are a registered trademarks of Intel Corporation in the United States and other countries. Ethernet is a registered trademark of Xerox Corporation in the United States. MODBUS is a trademark of Schneider Electric SA. VNC is a registered trademark of RealVNC Ltd. in the United States and other countries. Other company and product names herein are either trademarks or registered trademarks of their respective owners.
GOT SIMPLE series User's Manual JY997D52901A Specifications subject to change without notice. Printed in Japan, January 2014. When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14 , YADA-MINAMI 5-CHOME , HIGASHI-KU, NAGOYA , JAPAN
Mitsubishi Electric Europe B.V. / FA - European Business Group / Gothaer Straße 8 / D-40880 Ratingen / Germany / Tel.: +49(0)2102-4860 / Fax: +49(0)2102-4861120 / info@mitsubishi-automation.com / https://eu3a.mitsubishielectric.com Mitsubishi Electric Europe B.V. EUROPE Gothaer Straße 8 D-40880 Ratingen Phone: +49 (0)2102 / 486-0 Fax: +49 (0)2102 / 486-1120 Mitsubishi Electric Europe B.V. CzECh REP. Radlická 751/113e Avenir Business Park Cz-158 00 Praha 5 Phone: +420 251 551 470 Fax: +420 251 551 471 Mitsubishi Electric Europe B.V. FRANCE 25, Boulevard des Bouvets F-92741 Nanterre Cedex Phone: +33 (0)1 / 55 68 55 68 Fax: +33 (0)1 / 55 68 57 57 Mitsubishi Electric Europe B.V. IRELAND Westgate Business Park, Ballymount IRL-Dublin 24 Phone: +353 (0)1 4198800 Fax: +353 (0)1 4198890 Mitsubishi Electric Europe B.V. ITALY Viale Colleoni 7 Palazzo Sirio I-20864 Agrate Brianza (MB) Phone: +39 039 / 60 53 1 Fax: +39 039 / 60 53 312 Mitsubishi Electric Europe B.V. NEThERLANDs Nijverheidsweg 23a NL-3641RP Mijdrecht Phone: +31 (0) 297250350 Mitsubishi Electric Europe B.V. POLAND ul. Krakowska 50 PL-32-083 Balice Phone: +48 (0) 12 347 65 00 Fax: +48 (0) 12 347 65 01 Mitsubishi Electric Europe B.V. RUssIA 52, bld. 1 Kosmodamianskaya emb. RU-115054 Moscow Phone: +7 495 / 721 2070 Fax: +7 495 / 721 2071 Mitsubishi Electric Europe B.V. sPAIN Carretera de Rubí 76-80 Apdo. 420 E-08190 sant Cugat del Vallés (Barcelona) Phone: +34 (0) 93 / 5653131 Fax: +34 (0) 93 / 5891579 Mitsubishi Electric Europe B.V. (Scandinavia) swEDEN Fjelievägen 8 sE-22736 Lund Phone: +46 (0) 8 625 10 00 Fax: +46 (0) 46 39 70 18 Mitsubishi Electric Turkey Elektrik Ürünleri A.Ş. TURkEY Fabrika Otomasyonu Merkezi Şerifali Mahallesi Nutuk Sokak No.5 TR-34775 Ümraniye-İsTANBUL Phone: +90 (0)216 / 526 39 90 Fax: +90 (0)216 / 526 39 95 Mitsubishi Electric Europe B.V. Uk Travellers Lane Uk-hatfield, herts. AL10 8XB Phone: +44 (0)1707 / 28 87 80 Fax: +44 (0)1707 / 27 86 95 Mitsubishi Electric Europe B.V. UAE Dubai Silicon Oasis United Arab Emirates - Dubai Phone: +971 4 3724716 Fax: +971 4 3724721 Mitsubishi Electric Corporation JAPAN Tokyo Building 2-7-3 Marunouchi, Chiyoda-ku Tokyo 100-8310 Phone: +81 (3) 3218-2111 Fax: +81 (3) 3218-2185 Mitsubishi Electric Automation, Inc. UsA
500 Corporate Woods Parkway
Vernon hills, IL 60061 Phone: +1 (847) 478-2100 Fax: +1 (847) 478-0328 GEVA AUsTRIA Wiener Straße 89 A-2500 Baden Phone: +43 (0)2252 / 85 55 20 Fax: +43 (0)2252 / 488 60 OOO TECHNIKON BELARUs Prospect Nezavisimosti 177-9 BY-220125 Minsk Phone: +375 (0)17 / 393 1177 Fax: +375 (0)17 / 393 0081 ESCO DRIVES BELgIUM Culliganlaan 3 BE-1831 Diegem Phone: +32 (0)2 / 717 64 60 Fax: +32 (0)2 / 717 64 61 KONING & HARTMAN B.V. BELgIUM Woluwelaan 31 BE-1800 Vilvoorde Phone: +32 (0)2 / 257 02 40 Fax: +32 (0)2 / 257 02 49 INEA RBT d.o.o. BOsNIA AND hERzEgOVINA Stegne 11 sI-1000 Ljubljana Phone: +386 (0)1/ 513 8116 Fax: +386 (0)1/ 513 8170 AKHNATON BULgARIA 4, Andrei Ljapchev Blvd., PO Box 21 Bg-1756 sofia Phone: +359 (0)2 / 817 6000 Fax: +359 (0)2 / 97 44 06 1 INEA CR CROATIA Losinjska 4 a hR-10000 zagreb Phone: +385 (0)1 / 36 940 - 01/ -02/ -03 Fax: +385 (0)1 / 36 940 - 03 Kafkova 1853/3 Cz-702 00 Ostrava 2 Phone: +420 595 691 150 Fax: +420 595 691 199 Beijer Electronics A/S DENMARk Lykkegardsvej 17 Dk-4000 Roskilde Phone: +45 (0)46/ 75 76 66 Fax: +45 (0)46 / 75 56 26 HANS FØLSGAARD A/S DENMARk Theilgaards Torv 1 Dk-4600 køge Phone: +45 4320 8600 Fax: +45 4396 8855 Beijer Electronics Eesti OÜ EsTONIA Pärnu mnt.160i EE-11317 Tallinn Phone: +372 (0)6 / 51 81 40 Fax: +372 (0)6 / 51 81 49 Beijer Electronics OY FINLAND Vanha Nurmijärventie 62 FIN-01670 Vantaa Phone: +358 (0)207 / 463 500 Fax: +358 (0)207 / 463 501 PROVENDOR OY FINLAND Teljänkatu 8 A3 FIN-28130 Pori Phone: +358 (0) 2 / 522 3300 Fax: +358 (0) 2 / 522 3322 UTECO A.B.E.E. gREECE 5, Mavrogenous Str. gR-18542 Piraeus Phone: +30 (0)211 / 1206-900 Fax: +30 (0)211 / 1206-999 MELTRADE Kft. hUNgARY Fertő utca 14. hU-1107 Budapest Phone: +36 (0)1 / 431-9726 Fax: +36 (0)1 / 431-9727 Beijer Electronics SIA LATVIA Ritausmas iela 23 LV-1058 Riga Phone: +371 (0)6 / 784 2280 Fax: +371 (0)6 / 784 2281 Beijer Electronics UAB LIThUANIA Goštautų g. 3 LT-48324 kaunas Phone: +370 37 262707 Fax: +370 37 455605 ALFATRADE Ltd. MALTA 99, Paola Hill Malta-Paola PLA 1702 Phone: +356 (0)21 / 697 816 Fax: +356 (0)21 / 697 817 INTEHSIS SRL MOLDOVA bld. Traian 23/1 MD-2060 kishinev Phone: +373 (0)22 / 66 4242 Fax: +373 (0)22 / 66 4280 HIFLEX AUTOM. B.V. NEThERLANDs Wolweverstraat 22 NL-2984 CD Ridderkerk Phone: +31 (0)180 / 46 60 04 Fax: +31 (0)180 / 44 23 55 KONING & HARTMAN B.V. NEThERLANDs Energieweg 1 NL-2627 AP Delft Phone: +31 (0)15 260 99 06 Fax: +31 (0)15 261 9194 Beijer Electronics AS NORwAY Postboks 487 NO-3002 Drammen Phone: +47 (0)32 / 24 30 00 Fax: +47 (0)32 / 84 85 77 Fonseca S.A. PORTUgAL R. João Francisco do Casal 87/89 PT-3801-997 Aveiro, Esgueira Phone: +351 (0)234 / 303 900 Fax: +351 (0)234 / 303 910 SIRIUS TRADING & SERVICES SRL ROMANIA Aleea Lacul Morii Nr. 3 RO-060841 Bucuresti, sector 6 Phone: +40 (0)21 / 430 40 06 Fax: +40 (0)21 / 430 40 02 INEA SR d.o.o. sERBIA Ul. Karadjordjeva 12/217 sER-11300 smederevo Phone: +386 (026) 461 54 01 SIMAP SK (Západné Slovensko) sLOVAkIA Jána Derku 1671 sk-911 01 Trenčín Phone: +421 (0)32 743 04 72 Fax: +421 (0)32 743 75 20 INEA RBT d.o.o. sLOVENIA Stegne 11 sI-1000 Ljubljana Phone: +386 (0)1 / 513 8116 Fax: +386 (0)1 / 513 8170 Beijer Electronics Automation AB swEDEN Box 426 sE-20124 Malmö Phone: +46 (0)40 / 35 86 00 Fax: +46 (0)40 / 93 23 01 OMNI RAY AG swITzERLAND Im Schörli 5 Ch-8600 Dübendorf Phone: +41 (0)44 / 802 28 80 Fax: +41 (0)44 / 802 28 28 OOO “CSC-AUTOMATION” UkRAINE 4-B, M. Raskovoyi St. UA-02660 kiev Phone: +380 (0)44 / 494 33 44 HEADQUARTERS EUROPEAN REPRESENTATIVES EUROPEAN REPRESENTATIVES EURASIAN REPRESENTATIVES MIDDLE EAST REPRESENTATIVE TOO Kazpromavtomatika kAzAkhsTAN UL. ZHAMBYLA 28, kAz-100017 karaganda Phone: +7 7212 / 50 10 00 Fax: +7 7212 / 50 11 50 I.C. SYSTEMS Ltd. EgYPT 23 Al-Saad-Al-Alee St. Eg-sarayat, Maadi, Cairo Phone: +20 (0) 2 / 235 98 548 Fax: +20 (0) 2 / 235 96 625 GIRIT CELADON Ltd. IsRAEL
12 H’aomanut Street
Phone: +972 (0)9 / 863 39 80 Fax: +972 (0)9 / 885 24 30 ILAN & GAVISH Ltd. IsRAEL 24 Shenkar St., Kiryat Ariet IL-49001 Petah-Tikva Phone: +972 (0)3 / 922 18 24 Fax: +972 (0)3 / 924 0761 CEG LIBAN LEBANON Cebaco Center/Block A Autostrade DORA Lebanon-Beirut Phone: +961 (0)1 / 240 445 Fax: +961 (0)1 / 240 193 AFRICAN REPRESENTATIVE ADROIT TECHNOLOGIES sOUTh AFRICA
20 Waterford Office Park 189 Witkoppen Road