GCS XPPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 14

Technical content

The GCS Series has been designed to minimise the no load power consumption and maximise efficiency in order to facilitate equipment design to the latest environmental legislation. Approved for Class I and Class II applications, this range of single output AC-DC power supplies are packaged in an industry standard 3.0" x 5.0" x 1.42" package and achieves EN55011/22 Level B emissions compliance whilst maintaining very low earth leakage currents, making them suitable for a wide range of 1U and other industrial, IT and medical applications. Dimensions: GCS150/GCS180/GCS250/GCS350: w w w .xppow er.com 1 Models & Ratings Notes 1. Add suffix -C for convection cooled cover, e.g. G C S15 0PS12-C . 2. Add suffix -EF for fan cooled cover w ith end fan e.g. G C S15 0PS12-EF . N ote Vfan output no longer available. 3. Add suffix -TF for fan cooled cover w ith top fan, e.g. G C S15 0PS12-TF . N ote Vfan output no longer available. 4 . Add suffix -R for rem ote on/off, e.g. G C S15 0PS12-R , G C S15 0PS12-R C w ith convection cover or G C S15 0PS12-R EF/G C S15 0PS12-RTF w ith fan covers, (rem ote on/off is standard on G C S35 0 m odels). 5 . G C S25 0PS12-C & G C S25 0PS15 -C m odels derate 20% w hen convection cooled. 6. G C S35 0 convection rating quoted at 4 0 °C , others at 5 0 °C . 7 . G C S35 0-C m odels derate 15 % w hen convection-cooled at 4 0 °C . 8. 7 C FM required to m eet stated current for G C S15 0/180/25 0 and 15 C FM for G C S35 0. O utput Voltage V1 O utput C urrent V1 O utput Voltage (Vfan) & C urrent M ax O utput Pow er M odel N um ber (1,2,3,4 ,5) C onvection- cooled (6 ) Forced- cooled (8) G CS Series AC -D C Pow er Supplies

  • Convection/Forced-cooled Ratings
  • Universal 85 - 264 VAC Input
  • IT & Medical Safety Approvals (Class I & II)
  • < 0.5 W Standby Power (150 & 180 Models)
  • -40° C to +70° C Operation
  • Remote On/Off
  • Class B Emissions
  • 3 Year Warranty 150/180/250/350 Watts The series has single output versions from 12 V to 56 VDC, dual-fusing for compliance with IEC60601-1 and feature minimal excess heat generation as efficiencies reach 94%. They will deliver up to 350 W of power over an operating range of -40 °C and up to +70 °C and are available with a number of cover options.

Output Power (W) Input Voltage (VAC) GCS150PSxx convection-cooled 85 264 220 230 240 250 260 270 90 100 GCS180PSxx convection-cooled GCS150PSxx forced-cooled GCS180PSxx forced-cooled 250 240 230 220 210 200 190 180 170 160 Output Power (W) Input Voltage (VAC) 85 264 220 230 240 250 260 270 90 100 Forced-cooled (24 V / 28 V / 48 V) Forced-cooled (12 V / 15 V) Convection-cooled (All models) 360 340 320 300 280 260 240 220 200 180 160 Output Power (W) Input Voltage (VAC) 85 264 220 230 240 250 260 270 90 100 Forced-cooled Convection-cooled (at 40 °C) Convection-cooled (at 50 °C) Input G CS Series w w w .xppow er.com 2 AC -D C Pow er Supplies Input Voltage Derating Curve Figure 1 G C S150 & G C S180 G C S350 G C S250 C haracteristic M inim um Typical M axim um U nits N otes & C onditions Input Voltage - Operating 85 115/230 264 VAC Derate output power <90 VAC. See fig 1. Input Frequency 47 50/60 63 Hz Power Factor >0.9 230 VAC, 100% load Input Current - Full Load 1.5/0.7 A GCS150: 115/230 VAC 1.8/0.8 GCS180: 115/230 VAC 2.2/1.1 GCS250 12-15 V models: 115/230 VAC 2.4/1.2 GCS250 ≥24 V models: 115/230 VAC 3.6/1.8 GCS350: 115/230 VAC Inrush Current 80 A 230 VAC cold start 25 °C No Load Input Power 0.5 W All GCS150 & GCS180 (including -R Models)

2.3 GCS150 & GCS180 -R Models with inhibit activated

5 All GCS250 (including -R Models) 115V AC

3 All GCS250 (including -R Models) 230V AC

1 GCS250 -R Models with inhibit activated 115V AC

3 GCS250 -R Models with inhibit activated 230V AC

0.5 Available for GCS250 models, contact sales

4 GCS350: 115/230 VAC

µA GCS150: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. 95/185 250 GCS180: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. 95/185 250 GCS250: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. 95/185 250 GCS350: 115/230 VAC/50 Hz Typ., 264 VAC/60 Hz Max. Input Protection GCS150/180: F3.15 A/250 V internal fuse in both lines. GCS250/350: F5.0 A/250 V internal fuse in both lines.

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Output Output Overload Characteristic C haracteristic M inim um Typical M axim um U nits N otes & C onditions Output Voltage - V1 12 56 VDC See Models and Ratings table Initial Set Accuracy ±1 (V1) & ±5 (Vfan) % 50% load, 115/230 VAC Output Voltage Adjustment -V1 ±2 % Via potentiometer. See mech. details, Vfan will track Minimum Load 0A Start Up Delay 0.5 s 115/230 VAC full load Hold Up Time ms GCS150 Models 16/18 GCS180 Models

25 GCS250PS12 (225W)

17 GCS250 Other Models (250W)

17 GCS350

Drift ±0.2 % After 20 min warm up Line Regulation ±0.5 % 90-264 VAC Load Regulation ±0.5 (V1) , ±5 (Vfan) % 0-100% load Transient Response - V1 4% Recovery within 1% in less than 500 µs for a 50-75% and 75-50% load step Over/Undershoot - V1 0% Ripple & Noise - V1 1 % pk-pk 20 MHz bandwidth, 12V Models 1.5% max Overvoltage Protection - V1 110 140 % Vnom DC. Output 1, recycle input to reset Overload Protection - V1 110 150 % I nom See fig. 2. Trip and Restart Short Circuit Protection - V1 Continuous Temperature Coefficient 0.05 %/˚C Overtemperature Protection 110 °C At measurement point. Present on GCS350 only. Measured internally, auto resetting Trip & Restart Output Voltage (V) Output Load (A) 0 2468 10 12 14 16 18 20 22 24 Figure 2 G C S180PS12 exam ple (other sim ilar).

w w w .xppow er.com AC -D C Pow er Supplies General Efficiency Vs Load Figure 3

12 V Models

24 V Models

48 V Models

C haracteristic M inim um Typical M axim um U nits N otes & C onditions Efficiency 93 % 230 VAC Full load (see fig.3-5 )

80 Plus Silver All models except 12 V models

80 Plus Bronze 12 V models

Isolation: Input to Output Input to Ground Output to Ground

4000 VAC

1500 VAC

Switching Frequency 60 200 kHz PFC Converter 90 150 Main Converter Power Density 7.4 W/in 3 GCS150

8.8 GCS180

12.1 GCS250

16.4 GCS350

Mean Time Between Failure 569 kHrs MIL-HDBK-217F, Notice 2 +25 °C GB Weight: Open Frame End Fan Unit Top Fan Unit Covered Unit 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 20% 25% 50% 67% 75% 100% Load % Efficiency (%) Efficiency (%) Efficiency (%) 115V 230V 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 20% 25% 50% 67% 75% 100% Load % 115V 230V 0.00% 10.00% 20.00% 30.00% 40.00% 50.00% 60.00% 70.00% 80.00% 90.00% 100.00% 20% 25% 50% 67% 75% 100% Load % 115V 230V

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Signals & Controls Figure 6 Remote On/Off (Inhibit) Figure 8 Thermal Derating Curve Figure 7 Remote On/Off (Enable) C haracteristic N otes & C onditions Remote Sense Compensates for 0.5 V total voltage drop Remote On/Off (-R models) (Standard on GCS350 models) Inhibit The inhibit lo (pin 4), should be pulled below 0.4 V to switch V1 & Vfan off. Open circuit or >4 V to switch on (see fig. 6) Enable With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4) will enable V1 & V fan output. (see fig. 7) 0 V Inhibit Lo Pin 4 POWER SUPPLY Signals Connector 0 V Inhibit Lo Pin 4 Inhibit Hi Pin 5 POWER SUPPLY Signals Connector Environmental C haracteristic M inim um Typical M axim um U nits N otes & C onditions Operating Temperature -40 +70 °C See derating curve, fig. 8 Storage Temperature -40 +85 °C Cooling CFM Forced Cooled >110 W GCS150 Forced Cooled >150 W GCS180 Forced Cooled >180 W GCS250

15 GCS350

Humidity 5 95 %RH Non-condensing Operating Altitude 5000 m Shock ±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47 Vibration Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 -40 -20 0 +70 +50 100 Ambient Temperature (º C) Some specification parameters may not be met Output Load (%)

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Safety Approvals EMC: Immunity EMC: Emissions Phenom enon Standard Test Level C riteria N otes & C onditions Conducted EN55011/22 Class B Radiated EN55011/22 Class B GCS150 Class A GCS180/GCS250/GCS350 Class B GCS180 & GCS250 with 3 turns of output cable through added ferrite core. (Manufacturer: Fair - Rite Products Corp, Part No: 2643800502) Harmonic Fluctuations EN61000-3-3 Safety Agency Safety Standard N otes & C onditions C B R eport IEC 60950-1:2 005 Ed 2 Inform ation Technology IEC 60601-1 Ed 3 Including R isk M anagem ent M edical U L U L60950-1 (2 007 ), C SA 2 2 .2 N o.60950-1-1:08 Inform ation Technology ANSI/AAMI ES60601-1:2005 & CSA C22.2, No.60601-1:08 M edical TU V EN60950-1:2006 Inform ation Technology EN60601-1/A12:2006 M edical C E LVD & R oH S Equipm ent Protection C lass Class I & Class II See safety agency conditions of acceptibility for details M eans of Protection C ategory Primary to Secondary 2 x MOPP (Means of Patient Protection) IEC60601-1 Ed 3 Primary to Earth 1 x MOPP (Means of Patient Protection) Secondary to Earth 1 x MOPP (Means of Patient Protection) Phenom enon Standard Test Level C riteria N otes & C onditions Low Voltage PSU EMC EN61204-3 High severity level as below Harmonic Current EN61000-3-2 Class A All models Class C > 50 W GCS150 > 50 W GCS180 > 80 W GCS250 >125 W GCS350 Radiated EN61000-4-3 3A EFT EN61000-4-4 3A Surges EN61000-4-5 Installation class 3 A Conducted EN61000-4-6 3A Dips and Interruptions EN55024 (100 VAC) Dip >95% (0 VAC), 8.3ms A Dip 30% (70 VAC), 416ms B Dip >95% (0 VAC), 4160ms B EN55024 (240 VAC) Dip >95% (0 VAC), 10.0ms A Dip 30% (168 VAC), 500ms B Dip >95% (0 VAC), 5000ms B EN60601-1-2 (100 VAC) Dip >95% (0 VAC), 10.0ms A Dip 60% (40 VAC), 100ms A Derate Output Power to 85 W (GCS150) Derate Output Power to 90 W (GCS180) Derate Output Power to 120 W (GCS250) Derate Output Power to 150 W (GCS350) Dip 30% (70 VAC), 500ms A Dip >95% (0 VAC), 5000ms B EN60601-1-2 (240 VAC) Dip >95% (0 VAC), 10.0ms A Dip 60% (96 VAC), 100ms A Dip 30% (168 VAC), 500ms A Dip >95% (0 VAC), 5000ms B

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Mechanical Details Notes 1. All dimensions in inches (mm). 3. Weight: 0.65 lbs (0.29 kg) 4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72)

0.25 Faston Ground Tab

4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW O utput C onnector J2 M olex pn. 09- 6 5- 206 8 Pin Single Output 1 +V1 2 +V1 3 +V1

4 RTN

5 RTN

6 RTN

M olex pn. 09- 6 5- 2038 Pin Function

1 Line

2 Neutral

3 XP Internal Use

4 Inhibit LO

5 Inhibit HI

6 N/C

7 N/C

8 N/C

9 N/C

10 N/C

M olex pn. 22- 04 - 1021 Pin Function

1 Fan +(12 V)

2 Fan -

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Mechanical Details Notes 1. All dimensions in inches (mm). 3. Weight: 0.65 lbs (0.29 kg) 4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD- 001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW GCS250 12-15 V models GCS250 Other models Mechanical Details Notes 1. All dimensions in inches (mm). 3. Weight: 0.65 lbs (0.29 kg) 4. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD- 001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. O utput C onnector J2 M olex pn. 09- 6 5- 206 8 Pin Single Output 1 +V1 2 +V1 3 +V1 M olex pn. 09- 6 5- 2038 Pin Function M olex pn. 22- 04 - 1021 Pin Function 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW 5.0 (127.0) 0.20 (5.1) Note: Mounting points A should be connected together for optimum EMI performance 1.42 (36.3) 2.40 (61.0) 3.00 (76.2) 2.15 (54.6) A C23 C45 A C28 2.55 (64.7) 1.18 (29.8) 0.61 (15.6) 0.14 (3.5) 0.20 (5.1) 0.225 (5.72) 4 x 0.156 (3.96) mounting holes ø.312 (7.92) clearance top and bottom 0.18 (4.6) 0.15 (3.8) SMD Component Height AIRFLOW GCS250 12-15 V models GCS250 Other models

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Mechanical Details Notes 1. All dimensions in inches (mm). 3. Weight: 0.65 lbs (0.29 kg) 4. J1 mates with Molex Housing Pn. 09-50-1031. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. 12 position dual row J2 mates with Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. O utput C onnector 6 position J2 M olex pn. 09- 6 5- 206 8 Pin Function 1 +V1 2 +V1 3 +V1 M olex pn. 39- 28- 8120 Pin Function 1-3 RTN 4-6 +V1 7-9 RTN 10-12 +V1 Input C onnector J1 M olex pn. 09- 6 5- 2038 Pin Function M olex pn. 22- 04 - 1021 Pin Function 3.0 (76.2) 2.5 (64.7) 0.5 (12.6) 0.15 (3.8) SMD Component height M3 screw terminal bus bar Standard on 12/15 V models Optional on all other models 1.49 (37.8) 0.40 (10.2) M3 Screw 1.7 (44.8) 1.18 (29.8) 0.61 (15.6) 0.16 (4.1) 0.20 (5.1) 0.29 (7.4) 2.4 (61.0) 1.6 (40.6) 0.18 (4.6) 0.25 faston ground tab 4 x ø.156 (3.96) mounting hole ø.312 (7.92) clearance top and bottom 1 2 12J1 J3 1 1.8 0.22 (5.72) 0.20 (5.1) (46.7)

6 Position single row

Standard on 24/28/48/56 V models

12 Position dual row

Optional on 12/15 V models 5.0 (127.0) 1 2 1 2 GCS350 model

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Covered (-C) 2 10 1 2 1 2 0.39 (10.0) 0.93 (23.7) 2.39 (60.7) 0.45 (11.4) 1.70 (43.2) 4.72 (120.0) 5.50 (139.7) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 3.48 (88,5) 2.64 (67.0) 0.85 (21.6)

0.25 Faston

0.43 (10.8) 0.45 (11.4) 0.39 (10.0) 1.96 (50.0) 0.76 (19.3) 4.72 (120.0) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration Mechanical Details Notes 1. All dimensions in inches (mm). 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.05 lbs (0.48 kg) O utput C onnector J2 M olex pn. 09- 6 5- 206 8 Pin Single Output 1 +V1 2 +V1 3 +V1 M olex pn. 09- 6 5- 2038 Pin Function M olex pn. 22- 04 - 1021 Pin Function

G CS Series AC -D C Pow er Supplies w w w .xppow er.com Top Fan (-TF) 1 2 2 10 1 2 4.72 (120.0) 5.5 (139.7) 2 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 0.39 (10.0) 0.93 (23.7) 2.39 (60.7) 3.48 (88,5) 2.64 (67.0) 0.85 (21.6) 0.43 (10.8) 0.45 (11.4) 1.7 (43.2) 2.2 (57.8) 0.45 (11.4) 0.39 (10.0) 1.96 (50.0) 0.76 (19.3) 4.72 (120.0) 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration Mechanical Details Notes 1. All dimensions in inches (mm). 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.15 lbs (0.52 kg) O utput C onnector J2 M olex pn. 09- 6 5- 206 8 Pin Single Output 1 +V1 2 +V1 3 +V1 M olex pn. 09- 6 5- 2038 Pin Function M olex pn. 22- 04 - 1021 Pin Function

End Fan (-EF) GCS150/180/250 6.35 (161.3) 1.90 (48.2) 1.10 [27.8] 1 6 210 0.43 (10.8) 2.63 (66.9) 0.84 (21.5)

0.25 Faston (Right Angle) Ground Tab

3.48 (88.5) 1.70 (43.2) 0.93 (23.7) 0.76 (19.3) 1.96 (50.0) 0.39 (10.0) 4.72 (120.0) 2 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 4 x M3 x 0.5 THD 0.16 (4.0) max screw penetration 5.50 (139.7) Mechanical Details G CS Series AC -D C Pow er Supplies w w w .xppow er.com Notes 1. All dimensions in inches (mm). 3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. 4. In class II installations the cover is floating and provides 1 x MOPP (2 x MOOP). 5. Weight: 1.30 lbs (0.59 kg) O utput C onnector J2 M olex pn. 09- 6 5- 206 8 Pin Single Output 1 +V1 2 +V1 3 +V1 M olex pn. 09- 6 5- 2038 Pin Function M olex pn. 22- 04 - 1021 Pin Function

4.72 (120.0) 0.75 (18.9) 2.00 (50.8) 0.68 (17.2) 1.48 (37.7) 0.50 (12.6) 3.50 (88.9)2.02 (51.2)1.42 (36.2)0.86 (21.9) 0.99 (25.1) 0.25 (6.4) 0.56 (14.2) 1.75 (44.4) Input Terminal Block Dinkle P/N DT-2C-A02W-03 0.24 (6.0) 0.70 (17.7) M3 Screw 2 X M3 X 0.5 THD 0.16 (4.0) Max screw penetration 4 X M3 X 0.5 THD 0.16 (4.0) Max screw penetration 0.88 (22.3) End Fan (-EF) GCS350 Mechanical Details G CS Series AC -D C Pow er Supplies w w w .xppow er.com 13 Notes 1. All dimensions in inches (mm). 3. Weight: 0.65 lbs (0.29 kg) 4. 6 position single row J2 mates with Molex Housing Pn. 09-50-1061 and both with Molex series 5194 crimp terminals. 12 position dual row J2 mates with Molex Housing Pn. 39-01-2125 and with Molex series 5556 crimp terminals. J3 mates with Molex Housing Pn. 51191-0200 and with Molex series 50802 crimp terminals. J4 mates with JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals. O utput C onnector 6 position J2 M olex pn. 09- 6 5- 206 8 Pin Function 1 +V1 2 +V1 3 +V1 M olex pn. 39- 28- 8120 Pin Function 1-3 RTN 4-6 +V1 7-9 RTN 10-12 +V1 Input C onnector J1 D inkle PN D J- 26 - AD 2W - 03 Pin Function M olex pn. 22- 04 - 1021 Pin Function

G CS Series AC -D C Pow er Supplies w w w .xppow er.com 21-Sept-15 Estimated Service Life vs Component Temperature In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of direct air flow). See Mechanical Details for component locations. The estimated service life of the GCS Series is determined by the cooling arrangements and load conditions experienced in the end application. Due to the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitors with in the product when installed by the end application. The worst case of the two figures should be taken as the indicative service life in 24/7 operation. The graph below expresses the estimated lifetime of a given component temperature and assumes continuous operation at this temperature. Tem perature M easurem ents C om ponent M ax Tem perature °C T1 C oil 12 0 ° C L3 C oil 12 0 ° C Q 1 B ody 12 0 ° C Q 3 B ody 12 0 ° C C 6 105 ° C C 2 3 105 ° C Thermal Considerations Service Life 20000 40000 60000 80000 100000 120000 105 95 85 75 65 55 Lifetime (Hrs) C6 Temperature (°C) 10000 20000 30000 40000 50000 60000 70000 105 95 85 75 65 55 Lifetime (Hrs) C6 Temperature (°C) 5000 25000 45000 65000 85000 105000 125000 145000 165000 185000 105 95 85 75 65 C23 Temperature (°C) Lifetime (Hrs) G C S150/180 G C S250 G C S350 G C S350 G C S150/180 G C S250 5000 25000 45000 65000 85000 105000 125000 145000 165000 185000 105 95 85 75 65 C6 Temperature (°C) Lifetime (Hrs) 5000 25000 45000 65000 85000 105000 125000 145000 165000 185000 105 95 85 75 65 C23 Temperature (°C) Lifetime (Hrs) 5000 25000 45000 65000 85000 105000 125000 145000 165000 185000 105 95 85 75 65 C23 Temperature (°C) Lifetime (Hrs)