G58A5111P ROITHNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

18.08.2010 g58a5111p.doc 1 of 4 G58A5111P TECHNICAL DATA Visible LED 5 mm, InGaN Features Applications

  • High Luminous LEDs
  • 5mm Round Standard Directivity
  • Long Lifetime Operation
  • Superior Weather-resistance
  • UV Resistant Epoxy
  • Water Clear Type
  • Automotive Dashboard Lighting
  • Traffic Signal Lamp
  • Back Lighting
  • Other Lighting Diretivity: Absolute Maximum Ratings (Ta=25°C) Item Symbol Value Unit Power Dissipation P D 190 mW Forward Current I F 50 mA Pulse Forward Current * I FP 120 mA Reverse Voltage V R 5 V Operating Temperature T opr -30 … +85 °C Storage Temperature T stg -40 … +100 °C Soldering Temperature (5 sec.) T sol 260 °C * pulse width max. 10 ms, duty ratio max. 1/10 Outline Dimension: Specifications (Ta=25°C) Item Condition Symbol Min. Typ. Max. Unit Optical Specifications Luminous Intensity *1 I F = 50 mA I V 80000 100000 - mcd Dominant Wavelength I F = 50 mA λD 520 525 530 nm Viewing Angle I F = 50 mA 2 Θ1/2 - 15 - deg Electrical Specifications Forward Voltage I F = 50 mA U F 3.0 3.3 3.8 V Reverse Voltage U F = 5 V U R - - 10 µA Tolerance of chromaticity coordinates is ±10% Tolerance of luminous intensity is ±15% PIN Function

1 LED Anode

2 LED Cathode

Unit: mm Tolerance: ±0.3 mm

18.08.2010 g58a5111p.doc 2 of 4 Typical Performance Curves

18.08.2010 g58a5111p.doc 3 of 4 Reliability Test Report Classification Test Time Test Condition Operation Life IF = 50 mA Ta = 25 ±5 °C Test Time = 1000hrs (-24hrs, +72hrs) High Temerature High Humidity Storage R.H = 90~95% T a = 65 ±5 °C Test Time = 240hrs (+2hrs) High Temerature Storage Ta = 105 ±5 °C Test Time = 500hrs (-24 hrs, +48hrs) Endurance Test Low Temperature Storage Ta = 55 ±5 °C Test Time = 500hrs (-24hrs, +48hrs) Temperature Cycling 105 °C ~ 25 °C ~ 55 °C ~ 25 °C 60 min 10 min 60 min 10 min 20 cycles Thermal Shock 105 °C ~ -55 °C 10 min 10 min 10 cycles Solder Resistance Ta = 260 ±5 °C Test Time = 10 ±1 sec Environmental Test Solderability Ta = 230 ±5 °C Test Time = 5 ±1 sec Judgement Criteria Of Falure For The Reliability Measuring Time Symbol Conditions Failure Luminous Intensity I V I F = 50 mA I V < 0.5*Initial Value Forward Voltage U F I F = 50 mA U F < 1.2*Initial Value Reverse Current I R U F = 5 V I R > 2*Spec Operation Life Test Luminance Rate Curve * Brun-in condition: 50 mA * Projection of Statistical Average Light Output Degradation Performance for LED Technology Extrapolated from Test Data. * According to outgoing Packaged Products Specification * MTBF:100,000hrs, 90% Confidence (A Failure is Any LED Which is Open, shorted or fails to Emit Light) * The Projected Data is Base on The Feature of LED Itself Under Normal Operation Conditions. * Any Improper Circuit Design or External Factors Might Cause a Different Result.

18.08.2010 g58a5111p.doc 4 of 4 Precaution for Use 1. Cautions

  • DO NOT look directly into the light or look through the optical system. 2. Lead Forming
  • When forming leads, the leads should be bent at a point at least 3 mm from the base of the lead. DO NOT use the base of the leadframe as a fulcrum during lead forming.
  • Lead forming should be done before soldering.
  • DO NOT apply any bending stress to the base of the lead. The stress to the base may damage the LED’s characteristics or it may break the LEDs.
  • When mounted the LEDs onto the printed circuit board, the holes on the circuit board should be exactly aligned with the leads of LEDs. If the LEDs are mounted with stress at the leads, it causes deterioration of the lead and it will degrade the LEDs. 3. Soldering Conditions
  • Solder the LEDs no closer than 3 mm from the base of the lead.
  • Recommended soldering conditions: Dip Soldering Pre-Heat 120 °C Max. Pre-Heat Time 60 Seconds Max. Solder Bath Temperature 260 °C Max. Dipping Time 5 Seconds Max. Dipping Position No lower than 3 mm from the base of the epoxy bulb
  • DO NOT apply any stress to the lead particularly when heat.
  • The LEDs must not be reposition after soldering.
  • After soldering the LEDs, the lead should be protected from mechanical shock or vibration until the LEDs return to room temperature.
  • When it is necessary to clamp the LEDs to prevent soldering failure, it is important to minimize the mechanical stress on the LEDs.
  • Cut the LED leads at room temperature. Cutting the leads at high temperature may cause the failure of the LEDs. 4. Static Electricity
  • The LEDs are very sensitive to Static Electricity and surge voltage. So it is recommended that a wrist band or an anti-electrostatic glove be used when handling the LEDs.
  • All devices, equipment and machinery must be grounded properly. It is recommended that precautions should be taken against surge voltage to the equipment that mounts the LEDs. 5. Heat Generation
  • The powered LEDs generate heat. Heat dissipation should be considered in the application design to avoid the environmental conditions for operation in excess of the absolute maximum ratings.