The G308 Operator Interface Terminal combines unique capabilities normally expected from high-end units with a very affordable price. It is built around a high performance core with integrated functionality. This core allows the G308 to perform many of the normal features of the Paradigm range of Operator Interfaces while improving and adding new features. The G308 is able to communicate with many different types of hardware using high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100 Base-TX communications. In addition, the G308 features USB for fast downloads of configuration files and access to trending and data logging. A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files. In addition to accessing and controlling of external resources, the G308 allows a user to easily view and enter information. Users can enter data through the touchscreen or front panel 7-button keypad. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use the controller to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the controller. CONTENTS OF PACKAGE - G308 Operator Interface. - Panel gasket. - Template for panel cutout. - Hardware packet for mounting unit into panel. - Terminal block for connecting power.
ORDERING INFORMATION
1 Contact your Red Lion distributor or visit our website for complete selection.
2 Use this part number to purchase Crimson on CD with a printed
manual, USB cable, and RS-232 cable. Otherwise, download from www.redlion.net. 3 Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete details. 4 Battery type is lithium coin type CR2025. 5 Industrial grade two million write cycles. MODEL G308A - GRAPHIC LCD OPERATOR INTERFACE TERMINAL WITH VGA DISPLAY AND TOUCHSCREEN Bulletin No. G308A-E Drawing No. LP0613 Released 1/08 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CompactFlash is a registered trademark of CompactFlash Association. z CONFIGURED USING CRIMSON SOFTWARE (VERSION 2.0 BUILD
187 OR LATER)
z UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS (2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1 RS422/485 ON OPTIONAL COMMUNICATIONS CARD) z 10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS AND HOST WEB PAGES z USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC z UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY (8 MBYTE FLASH) z COMPACTFLASH ® SOCKET TO INCREASE MEMORY CAPACITY z 8.4-INCH TFT DISPLAY (256 COLOR, VGA 640X480 PIXELS) z 7-BUTTON KEYPAD FOR ON-SCREEN MENUS z THREE FRONT PANEL LEDS z POWER UNIT FROM 24VDC ±20% SUPPLY z RESISTIVE ANALOG TOUCHSCREEN CAUTION: Risk of Danger Read complete instructions prior to installationand operation of the unit. CAUTION: Risk of electric shock. MODEL NO. DESCRIPTION PART NUMBER
512 MB CompactFlash Card 5
64 MB CompactFlash Card 5
256 MB CompactFlash Card 5
CANopen Optional Communication Card RS232/485 Optional Communication Card G3CN0000 G3RS0000 PSDR G3PBDP Mini Power Supply 1 A Profibus DP Optional Communication Card PSDR0100 G3PBDP00 SFCRM2 Crimson 2.0 2 SFCRM200 CBL RS-232 Programming Cable CBLPROG0 G3CF G308A USB Cable CBLUSB00 Communications Cables 1 CBLxxxxx G3FILM Protective Films Replacement Battery 4 G3FILM08 BNL20000 DR DIN Rail Mountable Adapter Products 3 DRxxxxxx Operator Interface with TFT display for indoor applications, textured finish with embossed keys FOR USE IN HAZARDOUS LOCATIONS: Class I, Division 2, Groups A, B, C, and D Class II, Division 2, Groups F and G Class III, Division 2 63YN LABORATORY EQUIPMENT The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2/CLASS II, DIVISION 2/CLASS III, DIVISION 2
- POWER REQUIREMENTS: +24 VDC ±20% @ 24 W maximum. Must use Class 2 or SELV rated power supply. Power connection via removable three position terminal block. Notes: 1. The front panel PWR LED indicates power. 2. The G308’ s circuit common is not connected to the enclosure of the unit. See “Connecting to Earth Ground” in the section “Installing and Powering the G308.” 2. BATTERY: Lithium coin cell. Typical lifetime of 10 years. 3. DISPLAY: *Lifetime at room temperature. Refer to “Display” in “Software/Unit Operation” 4. 7-KEY KEYPAD: for on-screen menus. 5. TOUCHSCREEN: Resistive analog 6. MEMORY: On Board User Memory: 8 Mbyte of onboard non-volatile Flash memory. Memory Card : CompactFlash Type II slot for Type I and Type II CompactFlash cards. 7. COMMUNICATIONS: USB Port : Adheres to USB specification 1.1. Device only using Type B connection. Serial Ports: Format and Baud Rates for each port are individually software programmable up to 115,200 baud. PGM Port: RS232 port via RJ12. COMMS Ports: RS422/485 port via RJ45, and RS232 port via RJ12. DH485 TXEN: Transmit enable; open collector, V OH = 15 VDC, V OL = 0.5 V @ 25 mA max. Note: For additional information on the communications or signal common and connections to earth ground please see the “Connecting to Earth Ground” in the section “Installing and Powering the G308.” Ethernet Port: 10 BASE-T / 100 BASE-TX RJ45 jack is wired as a NIC (Network Interface Card). 8. ENVIRONMENTAL CONDITIONS: Operating Temperature Range: 0 to 50°C Storage Temperature Range: -20 to 60°C Operating and Storage Humidity: 80% maximum relative humidity (non- condensing) from 0 to 50°C. Vibration According to IEC 68-2-6 : Operational 10 to 55 Hz, in X, Y , Z direction for 1.5 hours, 1 g. Shock According to IEC 68-2-27: Operational 30 g’s, 9 msec in 3 directions. Altitude: Up to 2000 meters. 9. CERTIFICATIONS AND COMPLIANCES: SAFETY UL Recognized Component, File #E179259, UL61010-1, CSA 22.2 No. 61010-1 Recognized to U.S. and Canadian requirements under the Component Recognition Program of Underwriters Laboratories, Inc Type 4X Enclosure rating (Face only), UL50 UL Listed, File #E211967, UL61010-1, UL1604, CSA 22.2 No. 61010.1, CSA 22.2 No. 213-M1987 IECEE CB Scheme Test Certificate #US/9737C/UL CB Scheme Test Report #E179259-V01-S04 Issued by Underwriters Laboratories Inc. IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use, Part 1. IP66 Enclosure rating (Face only), IEC 529 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326: Electrical Equipment for Measurement, Control and Laboratory use. Notes: 1. Criterion A: Normal operation within specified limits. 2. Criterion B: Temporary loss of performance from which the unit self- recovers. 10. CONNECTIONS: Compression cage-clamp terminal block. Wire Gage: 12-30 AWG copper wire Torque: 5-7 inch-pounds (56-79 N-cm) 11. CONSTRUCTION: Steel rear metal enclosure with NEMA 4X/IP66 aluminum front plate for indoor use only when correctly fitted with the gasket provided. Installation Category II, Pollution Degree 2. 12. MOUNTING REQUIREMENTS: Maximum panel thickness is 0.25" (6.3 mm). For NEMA 4X/IP66 sealing, a steel panel with a minimum thickness of 0.125" (3.17 mm) is recommended. Maximum Mounting Stud Torque: 17 inch-pounds (1.92 N-m) 13. WEIGHT: 4.20 lbs (1.91 Kg) DIMENSIONS In inches (mm) SPECIFICATIONS SIZE G308A 8.4-inch TYPE TFT Active Matrix COLORS 256 PIXELS 640 X 480 (VGA) BRIGHTNESS 450 cd/m2 BACKLIGHT* 40,000 HR TYP. Class AEN 55011Emissions Emissions:
3 V/rms
Criterion BEN 61000-4-6RF conducted interference 2 kV L&N-E power 2 kV power Criterion AEN 61000-4-4Fast transients (burst) Criterion AEN 61000-4-5Surge 1 kV L-L,
10 V/m
Criterion AEN 61000-4-3Electromagnetic RF fields 1 kV signal 8 kV air discharge 4 kV contact discharge Criterion AEN 61000-4-2Electrostatic discharge Immunity to Industrial Locations: WARNING - DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION.
INSTALLING AND POWERING THE G308 MOUNTING INSTRUCTIONS This operator interface is designed for through-panel mounting. A panel cut- out diagram and a template are provided. Care should be taken to remove any loose material from the mounting cut-out to prevent that material from falling into the operator interface during installation. A gasket is provided to enable sealing to NEMA 4X/IP66 specification. Install the ten kep nuts provided and tighten evenly for uniform gasket compression. Note: Tightening the kep nuts beyond a maximum of 17 inch-pounds (1.92 N- m) may cause damage to the front panel. CONNECTING TO EARTH GROUND Each G308 has a chassis ground terminal on the back of the unit. Your unit should be connected to earth ground (protective earth). The chassis ground is not connected to signal common of the unit. Maintaining isolation between earth ground and signal common is not required to operate your unit. But, other equipment connected to this unit may require isolation between signal common and earth ground. To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit. For example, a power supply with isolation between its signal common and earth ground must be used. Also, plugging in a USB cable may connect signal common and earth ground. 1. USB’s shield may be connected to earth ground at the host. USB’s shield in turn may also be connected to signal common. POWER SUPPLY REQUIREMENTS The G308 requires a 24 VDC power supply rated at 24 W. Your unit may draw considerably less than 24 W depending upon the options being used. As additional features are used your unit will draw increasing amounts of power. Items that could cause increases in current are additional communications, optional communications card, CompactFlash card, and other features programmed through Crimson. In any case, it is very important that the power supply is mounted correctly if the unit is to operate reliably. Please take care to observe the following points: – The power supply must be mounted close to the unit, with usually not more than 6 feet (1.8 m) of cable between the supply and the operator interface. Ideally, the shortest length possible should be used. – The wire used to connect the operator interface’s power supply should be at least 22-gage wire. If a longer cable run is used, a heavier gage wire should be used. The routing of the cable should be kept away from large contactors, inverters, and other devices which may generate significant electrical noise. – A power supply with a Class 2 or SELV rating is to be used. A Class 2 or SELV power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults. SELV is an acronym for “safety extra-low voltage.” Safety extra-low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault, such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred. CONFIGURING A G308 The G308 is configured using Crimson software. Crimson is available as a free download from Red Lion’s website, or it can be purchased on CD. Updates to Crimson for new features and drivers are posted on the website as they become available. By configuring the G308 using the latest version of Crimson, you are assured that your unit has the most up to date feature set. Crimson software can configure the G308 through the RS232 PGM port, USB port, or CompactFlash. The USB port is connected using a standard USB cable with a Type B connector. The driver needed to use the USB port will be installed with Crimson. The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer. If you choose to make your own cable, use the “G308 Port Pin Out Diagram” for wiring information. The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card. The card is then inserted into the target G3 and powered. Refer to the Crimson literature for more information on the proper names and locations of the files. CABLES AND DRIVERS Red Lion has a wide range of cables and drivers for use with many different communication types. A list of these drivers and cables along with pin outs is available from Red Lion’s website. New cables and drivers are added on a regular basis. If making your own cable, refer to the “G308 Port Pin Outs” for wiring information. USB, DATA TRANSFERS FROM THE COMPACTFLASH CARD In order to transfer data from the CompactFlash card via the USB port, a driver must be installed on your computer. This driver is installed with Crimson and is located in the folder C:\\Program Files\\Red Lion Controls\\Crimson 2.0\\Device\\ after Crimson is installed. This may have already been accomplished if your G308 was configured using the USB port. Once the driver is installed, connect the G308 to your PC with a USB cable, and follow “Mounting the CompactFlash” instructions in the Crimson 2 user manual. COMMUNICATING WITH THE G308 All tolerances ±0.010" (±0.25 mm). ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN ARTICLE 501- 4 (b), 502-4 (b), AND 503-3 (b) OF THE NATIONAL ELECTRICAL CODE, NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES, OR AS SPECIFIED IN SECTION 19-152 OF CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA. WARNING - DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. USB PORT IS FOR SYSTEM SET-UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION. The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system.
The G308 has two RS232 ports. There is the PGM port and the COMMS port. Although only one of these ports can be used for programming, both ports can be used for communications with a PLC. The RS232 ports can be used for either master or slave protocols with any G308 configuration. Examples of RS232 communications could involve another Red Lion product or a PC. By using a cable with RJ12 ends on it, and a twist in the cable, RS232 communications with another G3 product or the Modular Controller can be established. Red Lion part numbers for cables with a twist in them are CBLPROG0 1, CBLRLC01 2, or CBLRC02 3. G3 RS232 to a PC G308 PORT PIN OUTS Connections G3: RJ12 Name PC: DB9 Name
4 COMM 1 DCD
5 Tx 2 Rx
2 Rx 3 Tx
3 COM 5 GND
1 CTS 7 RTS
6 RTS 8 CTS
1 CBLPROG0 can also be used to communicate with either a PC or an ICM5. 2 DB9 adapter not included, 1 foot long. 3 DB9 adapter not included, 10 feet long. ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE-T or 100 BASE-TX. The G308 unit’s RJ45 jack is wired as a NIC (Network Interface Card). For example, when wiring to a hub or switch use a straight-through cable, but when connecting to another NIC use a crossover cable. The Ethernet connector contains two LEDs. A yellow LED in the upper right, and a bi-color green/amber LED in the upper left. The LEDs represent the following statuses: The Crimson manual contains additional information on Ethernet communications. LED COLOR DESCRIPTION YELLOW solid Link established YELLOW flashing Data being transferred GREEN 10 BASE-T Communications AMBER 100 BASE-TX Communications
The G308 has one RS422/485 port. This port can be configured to act as either RS422 or RS485. Note: All Red Lion devices connect A to A and B to B, except for Paradigm devices. Refer to www.redlion.net for additional information. Examples of RS485 2-Wire Connections G3 to Red Lion RJ11 (CBLRLC00) DLC, IAMS, ITMS, PAXCDC4C A+4TxA2 B-5TxB1 COM3COM6 TxEN2TxEN5 NameRLC: RJ11NameG3: RJ45 Connections G3 to Modular Controller (CBLRLC05) TxA8TxA8 TxB7TxB7 COM6COM6 TxEN5TxEN5 RxA TxA 3,2 2,3 RxA TxA 3,2 2,3 RxB4,1RxB4,1 TxB1,4TxB1,4 NameModular ControllerNameG3 Connections DH485 COMMUNICATIONS The G308’s RS422/485 COMMS port can also be used for Allen Bradley DH485 communications. WARNING: DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment. A cable and wiring diagram are available from Red Lion. G3 to AB SLC 500 (CBLAB003) 24V-TxA3, 8 COMM-TxB4, 7 SHIELD4COMM6 TxEN5TxEN5 COMM-RxB4, 7 24V-RxA3, 8 B2TxA2 A1TxB1 NameRJ45: A-BNameRJ45: RLC Connections RS422/485 4-WIRE CONNECTIONS RS485 2-WIRE CONNECTIONS
Crimson software is available as a free download from Red Lion’s website or it can be purchased on a CD, see “Ordering Information” for part number. The latest version of the software is always available from the website, and updating your copy is free. DISPLAY This operator interface uses a liquid crystal display (LCD) for displaying text and graphics. The display utilizes a cold cathode fluorescent tube (CCFL) for lighting the display. The CCFL tubes can be dimmed for low light conditions. These CCFL tubes have a limited lifetime. Backlight lifetime is based upon the amount of time the display is turned on at full intensity. Turning the backlight off when the display is not in use can extend the lifetime of your backlight. This can be accomplished through the Crimson software when configuring your unit. FRONT PANEL LEDS There are three front panel LEDs. Shown below is the default status of the LEDs. 1. The operator interface is shipped without a configuration. After downloading a configuration, if the light remains in the flashing state continuously, try cycling power. If the LED still continues to flash, try downloading a configuration again. 2. Do not turn off power to the unit while this light is flickering. The unit writes data in two minute intervals. Later Microsoft operating systems will not lock the drive unless they need to write data; Windows 98 may lock the drive any time it is mounted, thereby interfering with logging. Refer to “Mounting the CompactFlash” in the Crimson 2 User Manual. TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input. The unit will only produce an audible tone (beep) when a touch on an active touchscreen cell is sensed. The touchscreen is fully functional as soon as the operator interface is initialized, and can be operated with gloved hands. KEYPAD The G308 keypad consists of seven keys that can be used for on-screen menus. TROUBLESHOOTING YOUR G308 If for any reason you have trouble operating, connecting, or simply have questions concerning your new G308, contact Red Lion’s technical support. For contact information, refer to the back page of this bulletin for phone and fax numbers. EMAIL: techsupport@redlion.net Web Site: http://www.redlion.net Valid configuration is loaded and there are no alarms present.STEADY A tag is in an alarm state.FLASHING GREEN (BOTTOM) Valid CompactFlash card present.STEADY YELLOW (MIDDLE) Unit is powered and running an application. Unit is in the boot loader, no valid configuration is loaded. 1 LED INDICATION RED (TOP, LABELED “PWR”) CompactFlash card being checked. No CompactFlash card is present. FLICKERING FLASHING RAPIDLY OFF STEADY FLASHING FLASHING SLOWLY Incorrectly formatted CompactFlash card present. Unit is writing to the CompactFlash, either because it is storing data, or because the PC connected via the USB port has locked the drive.
BATTERY & TIME KEEPING A battery is used to keep time when the unit is without power. Typical accuracy of the G308 time keeping is less than one minute per month drift. The battery of a G308 unit does not affect the unit’s memory, all configurations and data is stored in non-volatile memory. To change the battery of a G308, remove power, cabling, and then the rear cover of the unit. To remove the cover, remove the four screws designated by the arrows on the rear of the unit. Then, by lifting the top side, hinge the cover, thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below. Install in the reverse manner. Remove the old battery* from the holder and replace with the new battery. Replace the rear cover, cables, and re-apply power. Using Crimson or the unit’s keypad, enter the correct time and date. * Please note that the old battery must be disposed of in a manner that complies with your local waste regulations. Also, the battery must not be disposed of in fire, or in a manner whereby it may be damaged and its contents come into contact with human skin. The battery used by the G308 is a lithium type CR2025. CAUTION: RISK OF ELECTRIC SHOCK The inverter board, attached to the mounting plate, supplies the high voltage to operate the backlight. Touching the inverter board may result in injury to personnel. CAUTION : The circuit board contains static sensitive components. Before handling the operator interface without the rear cover attached, discharge static charges from your body by touching a grounded bare metal object. Ideally, handle the operator interface at a static controlled clean workstation. Also, do not touch the surface areas of the circuit board. Dirt, oil, or other contaminants may adversely affect circuit operation. WARNING - EXPLOSION HAZARD - THE AREA MUST BE KNOWN TO BE NON-HAZARDOUS BEFORE SERVICING/ REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I/O WIRING AND BATTERY. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON-HAZARDOUS.
The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The Company disclaims all liability for any affirmation, promise or representation with respect to the products. The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92- 573) and liability imposed upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter. No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations. OPTIONAL FEATURES AND ACCESSORIES COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept either Type I or II cards. Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with the G308’s CompactFlash socket. Cards are available at most computer and office supply retailers. CompactFlash can be used for configuration transfers, larger configurations, data logging, and trending. Information stored on a CompactFlash card by a G308 can be read by a card reader attached to a PC. This information is stored in IBM (Windows ®) PC compatible FAT16 file format. OPTIONAL COMMUNICATION CARD Red Lion offers optional communication cards for fieldbus communications. These communication cards will allow your G308 to communicate with many of the popular fieldbus protocols. Red Lion is also offering a communications card for additional RS232 and RS422/485 communications. Visit Red Lion’s website for information and availability of these cards. CUSTOM LOGO Each G3 operator interface has an embossed area containing the Red Lion logo. Red Lion can provide custom logos to apply to this area. Contact your distributor for additional information and pricing. Note: Do not remove or insert the CompactFlash card while power is applied. Refer to “Front Panel LEDs.” NOTE For reliable operation in all of our products, Red Lion recommends the use of SanDisk® and SimpleTech brands of CompactFlash cards. Industrial grade versions that provide up to two million write/erase cycles minimum are available from Red Lion. Red Lion Controls