DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 28
Technical content
Version 2.0 4 June 2013 2 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. - CONTENTS -
1.1 OVERVIEW
1.2 FEATURES
1.3 APPLICATION
1.4 GENERAL SPECIFICATIONS
1.5 MECHANICAL SPECIFICATIONS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
2.2.2 BACKLIGHT UNIT
3.1 TFT LCD MODULE
3.2 BACKLIGHT UNIT
4.1 TFT LCD MODULE
5.1 TFT LCD MODULE
5.2 BACKLIGHT UNIT
5.3 COLOR DATA INPUT ASSIGNMENT
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
6.2 POWER ON/OFF SEQUENCE
6.3 THE INPUT DATA FORMAT
6.4 SCANNING DIRECTION
7.1 TEST CONDITIONS
7.2 OPTICAL SPECIFICATIONS
9.1 PACKING SPECIFICATIONS
9.2 PACKING METHOD
9.3 UN-PACKING METHOD
11.1 ASSEMBLY AND HANDLING PRECAUTIONS
11.2 SAFETY PRECAUTIONS
Version 2.0 4 June 2013 3 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited.
REVISION HISTORY
Version Date Section Description Ver. 2.0 Jun 4, 2013 All Approval Specification was first issued.
Version 2.0 4 June 2013 4 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 1. GENERAL DESCRIPTION G150XGE-L04 is a 15.0” TFT Liquid Crystal Display module with LED Backlight units and 20 pins LVDS interface. This module supports 1024 x 768 XGA mode and can display 16.2M/262k colors. The PSWG is to establish a set of displays with standard mechanical dimensions and select electrical interface requirements for an industry standard 15.0” XGA LCD panel and the LED driving device for backlight is built in PCBA.
- XGA (1024 x 768 pixels) resolution - DE (Data Enable) only mode - LVDS Interface with 1pixel/clock - PSWG (Panel Standardization Working Group) - Wide operating temperature. - RoHS compliance
-TFT LCD Monitor - Factory Application - Amusement
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note Active Area 304.1 (H) x 228.1(V) (15.0” diagonal) m m Bezel Opening Area 307.4(H) x 231.3(V) mm (1) Driver Element a-Si TFT active matrix - - Pixel Number 1024 x R.G.B x 768 pixel - Pixel Pitch 0.297(H) x 0.297(W) mm - Pixel Arrangement RGB vertical Stripe - - Display Colors 16.7M / 262K color - Display Mode Normally White - - Surface Treatment Hard Coating (3H), Anti-Glare ( Haze 25) - - Module Power Consumption 10.6 (Black pattern) W Typ ical
Version 2.0 4 June 2013 5 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Item Min. Typ. Max. Unit Note Horizontal(H) 326 326.5 327 mm Vertical(V) 253 253.5 254 mm (1) Module Size Depth(D) - 11.5 12.0 mm (1)(2) Weight - 1084 1134 g - Note (1) Please refer to the attached drawings for more information of front and back outline dimensions. Note (2) The depth is without connector. +/ - 0.5mm
Version 2.0 4 June 2013 6 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 2. ABSOLUTE MAXIMUM RATINGS Value Item Symbol Min. Max. Unit Note Operating Ambient Temperature TOP -30 +80 ℃ Storage Temperature T ST -40 +85 ℃ Note (1) Temperature and relative humidity range is shown in the figure below. (2) 90 %RH Max. (Ta 40≦ ℃). (3) Wet-bulb temperature should be 39 ℃ Max. (Ta > 40 ℃). (4) No condensation. 100 80 60 -20 40 0 20 -40 Temperature (ºC) Operating Range Relative Humidity (%RH) Storage Range
Version 2.0 4 June 2013 7 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Value Item Symbol Min. Max. Unit Note Power Supply Voltage VCC -0.3 4 V (1) Value Item Symbol Min. Max. Unit Note Converter Voltage V i -0.3 18 V (1) , (2) Enable Voltage EN --- 5.5 V Backlight Adjust ADJ --- 5.5 V Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation should be restricted to the conditions described under Normal Operating Conditions. Note (2) Specified values are for lamp (Refer to 3.2 for further information).
Version 2.0 4 June 2013 8 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 3. ELECTRICAL CHARACTERISTICS Value Parameter Symbol Min. Typ. Max. Unit Note Power Supply Voltage V CC 3.0 3.3 3.6 V - Ripple Voltage V RP - - 100 mVp-p Rush Current I RUSH - - 2.0 A (2) White - 410 510 mA (3)a Power Supply Current Black lcc - 590 690 mA (3)b LVDS differential input voltage Vid 200 - 600 mV LVDS common input voltage Vic 1.0 1.2 1.4 V “H” Level V IH - - 100 mV - Differential Input Voltage for LVDS Receiver Threshold “L” Level V IL -100 - - mV - Terminating Resistor R T - 100 - Ohm - Note (1) The module should be always operated within above ranges. Note (2) Measurement Conditions: 470 μs +3.3V GND
0.9 VCC
0.1 VCC
(High to Low) (Control Signal) +12V SW 1uF VCC +3.3V 2SK1470 Q1 2SK1475 47K VR1 47K C2 0.01uF 1uF FUSE (LCD Module Input)
Version 2.0 4 June 2013 9 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Note (3) The specified power supply current is under the conditions at V DD =3.3V, Ta = 25 ± 2 ℃, DC Current and f v = 60 Hz, whereas a power dissipation check pattern below is displayed.
3.2 BACKLIGHT UNIT Ta = 25 ± 2 ℃
Parameter Symbol Min. Typ. Max. Unit Note Converter Power Supply Voltage V i 10.8 12.0 13.2 V Converter Power Supply Current I i 0.5 0.72 0.8 A @ Vi = 12V (Duty 100%) Backlight Power Consumption P BL - 8.64 W @ Vi = 12V (Duty 100%) Backlight on 2.0 3.3 5.0 V EN Control Level Backlight off - 0 --- 0.8 V PWM High Level 2.0 3.3 5.0 V PWM Control Level PWM Low Level - 0 - 0.15 V PWM Control Duty Ratio - 1 - 100 % @200Hz PWM Control Frequency f PWM 190 200 20k Hz (2) LED Life Time L L 50,000 - - Hrs (3) Note (1) LED current is measured by utilizing a high frequency current meter as shown below: Note (2) At 20k Hz PWM control frequency ,duty ratio range is restricted from 20% to 100%. Note (3) The lifetime of LED is defined as the time when it continues to operate under the conditions at Ta = 25 ±2 ℃ and Duty 100% until the brightness becomes 50% of its original value. Operating ≦ LED under high temperature environment will reduce life time and lead to color shift. Active Area a. White Pattern Active Area b. Black Pattern Power Supply Converter LED Backlight Unit Vi, Ii GND Input Power P BL
Version 2.0 4 June 2013 10 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 4. BLOCK DIAGRAM (1024x3x768) DATA DRIVER IC SCAN DRIVER IC DC/DC CONVERTER & REFERENCE VOLTAGE INPUT CONNECTOR (STM MSB240420-E) RX0(+/-) RX1(+/-) RX2(+/-) RX3(+/-) RXCLK(+/ -) LVDS RECEIVER VCC SEL68 GND Converter LED BACKLIGHT UNIT CONVERTER CONNECTOR (Connector, 3823K-F05N-03L, 5pin, Entery) Vi
Version 2.0 4 June 2013 11 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 5. INPUT TERMINAL PIN ASSIGNMENT Pin No. Symbol Function Polarity Note 1 VCC Power Supply +3.3V(typical) 2 VCC Power Supply +3.3V(typical)
3 GND Ground
4 LR/UD Reverse Scan Control
H or NC = Normal Mode. L = Horizonta/ Vertical Reverse Scan.
5 RX0- LVDS Differential Data Input Negative
6 RX0+ LVDS Differential Data Input Positive
7 GND Ground
8 RX1- LVDS Differential Data Input Negative
9 RX1+ LVDS Differential Data Input Positive
10 GND Ground
11 RX2- LVDS Differential Data Input Negative
12 RX2+ LVDS Differential Data Input Positive
13 GND Ground
14 RXCLK- LVDS Differential Data Input Negative
15 RXCLK+ LVDS Differential Data Input Positive
16 GND Ground
17 RX3- LVDS Differential Data Input Negative
18 RX3+ LVDS Differential Data Input Positive
19 GND Ground
20 SEL68 LVDS 6/8 bit select function control,
High /barb2right 6bit Input Mode Low or NC /barb2right 8bit Input Mode Note (3) Note (1) Connector Part No.: STM MSB240420G, Entery 3804K-F20N-10L or equivalent. Note (2) User’s connector Part No.: STM P240420, Entery H204K-D20N-02B or equivalent. Note (3) “Low” stands for 0V. “High” stands for 3.3V. “NC” stands for “No Connection”.
5.2 BACKLIGHT UNIT(Converter connector pin)
Pin Symbol Description Remark
1 V i Converter input voltage 12V
2 V GND Converter ground Ground
3 EN Enable pin 3.3V
4 ADJ Backlight Adjust PWM Dimming
(Hi: 3.3V DC , Lo: 0V DC )
5 NC Not Connect
Note (1) Connector Part No.: 3808K-F05N-03L (Entery) or equivalent. Note (2) User’s connector Part No.: H208K-P05N-02B (Entery) or equivalent.
Version 2.0 4 June 2013 12 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for the color. The higher the binary input the brighter the color. The table below provides the assignment of color versus data input. Data Signal Red Green Blue Color R7 R6 R5 R4 R3 R2 R1 R0 R7 R6 G5 G4 G3 G2 G1 G0 R7 R6 B5 B4 B3 B2 B1 B0 Basic Colors Black Red Green Blue Cyan Magenta Yellow White Gray Scale Of Red Red(0) / Dark Red(1) Red(2) Red(252) Red(252) Red(252) Gray Scale Of Green Green(0)/Dark Green(1) Green(2) Green(252) Green(252) Green(252) Gray Scale Of Blue Blue(0) / Dark Blue(1) Blue(2) Blue(252) Blue(252) Blue(252) Note (1) 0: Low Level Voltage, 1: High Level Voltage
Version 2.0 4 June 2013 13 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 6. INTERFACE TIMING The input signal timing specifications are shown as the following table and timing diagram . Signal Item Symbol Min. Typ. Max. Unit Note DCLK Pixel Clock 1/T C 53.35 65 80 MHz - Vertical Total Time T V 780 806 1200 TH - Vertical Address Time TVD 768 768 768 T H - Horizontal Total Time TH 1140 1344 1600 TC - DE Horizontal Address Time THD 1024 1024 1024 TC - Note (1) Because this module is operated by DE only mode, Hsync and Vsync input signals should be set to low logic level or ground. Otherwise, this module would operate abnormally. INPUT SIGNAL TIMING DIAGRAM TH TC DCLK THD TVD Tv DE DE DATA
Version 2.0 4 June 2013 14 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. T/7 RESERVED B07 B06 G07 G06 R07 R06 DE GND GND B05 B04 B03 B02 B01 B00 G05 G04 G03 G02 G01 G00 R05 R04 R03 R02 R01 R00 TxCLK OUT RxCK IN Rx IN3 Rx IN2 Rx IN1 Rx IN0 TIMING DIAGRAM of LVDS T RxOUT23 RxOUT26 RxOUT25 RxOUT24 RxOUT22 RxOUT12 RxOUT9 RxOUT8 RxOUT7 RxOUT6 RxOUT4 RxOUT3 RxOUT2 RxOUT1 RxOUT0 RxOUT21 RxOUT20 RxOUT19 RxOUT18 RxOUT15 RxOUT14 RxOUT13 RxOUT17 RxOUT16 RxOUT11 RxOUT10 RxOUT5 RxOUT27
Version 2.0 4 June 2013 15 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. To prevent a latch-up or DC operation of LCD assembly, the power on/off sequence should be as the diagram below. LVDS VCC Vi 10% 90% 0.1VCC 0.9VCC 0.9VCC 0.1VCC T4 VALID 0.9Vi 0.9Vi 0.1Vi 0.1Vi PWM DIMMING 10% 90% BL ON/OFF 10% 90% Power ON/OFF sequence Note (1) Please avoid floating state of interface signal at invalid period. Note (2) When the interface signal is invalid, be sure to pull down the power supply of LCD VCC to 0 V. Note (3) The Backlight converter power must be turned on after the power supply for the logic and the interface signal is valid. The Backlight converter power must be turned off before the power supply for the logic and the interface signal is invalid. Value Parameter Min Typ Max Units T1 0.5 - 10 ms T2 0 - 50 ms T3 0 - 50 ms T4 500 - - ms T5 200 - - ms T6 200 - - ms T7 5 - 300 ms T8 10 - - ms T9 10 - - ms
Version 2.0 4 June 2013 16 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. The following figures show the image see from the front view. The arrow indicates the direction of scan. Fig.1 Normal Scan Fig .2 Reverse Scan Fig. 1 Normal scan ( pin 4, LR/UD = High or NC ) Fig. 2 Reverse scan (pin 4, LR/UD = Low )
Version 2.0 4 June 2013 17 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 7. OPTICAL CHARACTERISTICS Ambient Temperature Ta 25 ±2 ℃ Ambient Humidity Ha 50 ±10 %RH Supply Voltage V CC 3.3 V Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS" Converter Voltage V i 12 V Converter Duty 100% The relative measurement methods of optical characteristics are shown in 7.2. The following items should be measured under the test conditions described in 7.1 and stable environment shown in Note (5). Item Symbol Condition Min. Typ. Max. Unit Note Rx 0.604 Red Ry 0.356 Gx 0.338 Green Gy 0.590 Bx 0.148 Blue By 0.098 Wx 0.313 Color Chromaticity White Wy Typ - 0.05 0.329 Typ+ 0.05 - (1), (5) Center Luminance of White LC 300 400 cd/m 2 (4), (5) Contrast Ratio CR θx=0 °, θY =0 ° CS-1000T 450 700 - (2), (5) TR - 5 10 Response Time TF θx=0 °, θY =0 ° - 11 16 ms (3) White Variation δW θx=0 °, θY =0 ° θx+ 70 80 - Horizontal θx- 70 80 - θY+ 55 70 - Viewing Angle Vertical θY- CR ≧ 10 USB2000 60 70 - Deg. (1), (5)
Version 2.0 4 June 2013 18 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Note (1) Definition of Viewing Angle (θx, θy): Note (2) Definition of Contrast Ratio (CR): The contrast ratio can be calculated by the following expression. Contrast Ratio (CR) = L255 / L0 L255: Luminance of gray level 255 L0: Luminance of gray level 0 CR = CR (5) CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (6). Note (3) Definition of Response Time (TR , TF): 12 o’clock direction θy+ = 90º 6 o’clock θy- = 90º θx- θx+ θy- θy+ y- x+ Normal θx = θy = 0º θX+ = 90º θX- = 90º 100% 90% 10% Gray Level 255 Gray Level 0 Gray Level 255 Time TF Optical Response TR 66.67m 66.67ms
Version 2.0 4 June 2013 19 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Note (4) Definition of Luminance of White (L C ): Measure the luminance of gray level 255 at center point LC = L (5) L (x) is corresponding to the luminance of the point X at Figure in Note (6). Note (5) Measurement Setup: The LCD module should be stabilized at given temperature for 20 minutes to avoid abrupt temperature change during measuring. In order to stabilize the luminance, the measurement should be executed after lighting Backlight for 20 minutes in a windless room. CS-1000T 500 mm LCD Module LCD P anel Center of the S creen Light Shield Room (Ambient Luminance < 2 lux) USB2000
Version 2.0 4 June 2013 20 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. Note (6) Definition of White Variation (δW): Measure the luminance of gray level 63 (255) at 9 points δW =
Version 2.0 4 June 2013 21 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 8. RELIABILITY TEST CRITERIA Test Item Test Condition Note High Temperature Storage Test 85 ℃, 240 hours Low Temperature Storage Test -40℃, 240 hours Thermal Shock Storage Test -30℃, 0.5 hour ←→80 ℃, 0.5 hour; 100cycles, 1 hour/cycle High Temperature Operation Test 80 ℃, 240 hours Low Temperature Operation Test -30 ℃, 240 hours High Temperature & High Humidity Operation Test 60 ℃, RH 90%, 240 hours (1), (2) ESD Test (Operation) 150pF, 330 Ω, 1 sec/cycle Condition 1 : panel contact, ±8 KV Condition 2 : panel non-contact ±15 KV (2) Shock (Non-Operating) 50G, 11ms, half sine wave, 1 time for ± X, ± Y , ± Z direction (2), (3) Vibration (Non-Operating) 1.5G, 10 ~ 300 Hz sine wave, 10 min/cycle, 3 cycles each X, Y , Z direction (2), (3) Note (1) No condensation of water. Note (2) No display malfunction. Note (3) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough so that the module would not be twisted or bent by the fixture. Note (4) Temperature of panel display surface area should be 90 ℃ Max.
Version 2.0 4 June 2013 22 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 9. PACKAGING
Version 2.0 4 June 2013 23 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited.
9.3 PACKING METHOD
Version 2.0 4 June 2013 24 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 10. DEFINITION OF LABELS
10.1 INX MODULE LABEL
The barcode nameplate is pasted on each module as illustration, and its definitions are as following explanation. (a) Model Name: G150XGE -L04 (b) Revision: Rev. XX, for example: A1, B1, C1, C2 …etc. (c) ﹡﹡﹡﹡: Factory ID (d) Serial ID: X X X X X X X Y M D X N N N N Serial ID includes the information as below: (a) Manufactured Date: Year: 1~9, for 2011~2019 Month: 1~9, A~C, for Jan. ~ Dec. Day: 1~9, A~Y , for 1 st to 31 st , exclude I , O and U (b) Revision Code: cover all the change (c) Serial No.: Manufacturing sequence of product Year, Month, Date INX Internal Use Revision Serial No. INX Internal Use INX Internal Use X X X X X X X Y M D L N N N N G150XGE -L04 Rev.XX ﹡﹡﹡﹡ RoHS E207943
Version 2.0 4 June 2013 25 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 11. PRECAUTIONS (1) Do not apply rough force such as bending or twisting to the module during assembly. (2) To assemble or install module into user’s system can be only in clean working areas. The dust and oil may cause electrical short or worsen the polarizer. (3) It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight will be damaged. (4) Always follow the correct power sequence when LCD module is connecting and operating. This can prevent damage to the CMOS LSI chips during latch-up. (5) Do not pull the I/F connector in or out while the module is operating. (6) Do not disassemble the module. (7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and easily scratched. (8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage LCD module when it is operating. (9) High temperature or humidity may reduce the performance of module. Please store LCD module within the specified storage conditions. (10) When ambient temperature is lower than 10 ℃ may reduce the display quality. For example, the response time will become slowly. (11) Do not keep same pattern in a long period of time. It may cause image sticking on LCD. (1) Do not disassemble the module or insert anything into the Backlight unit. (2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap. (3) After the module’s end of life, it is not harmful in case of normal operation and storage.
Version 2.0 4 June 2013 26 / 27 The copyright belongs to InnoLux. Any unauthorized use is prohibited. 12. MECHANICAL CHARACTERISTICS