www.sensortechnics.com

FEATURES

  • 0...1500 g range
  • High impedance bridge
  • Compact, commercial grade package
  • Robust performance characteristics
  • Ratiometric electrical output
  • Extremely low deflection
  • High ESD resistance

APPLICATIONS

  • Medical infusion pumps
  • Ambulatory noninvasive pump pressure
  • Occlusion detection
  • Kidney dialysis machines
  • Load and compression sensing
  • Variable tensions control
  • Robotic end-effectors
  • Wire bonding equipment SPECIFICATIONS Maximum ratings Supply voltage Temperature limits Storage Operating Lead temperature (5 sec. soldering) Humidity limits Vibration (0 to 2000 Hz) (qualification tested, 0 to 2 KHz) Mechanical shock (qualification tested) Over force 3..6 V -40 to +100°C -40 to +85°C 315°C 0...99 %RH 20 g sine 150 g 4500 g ELECTRICAL CONNECTION Scale: 1 cm ½ inch Output + Vout2 Vs - Vout GND

www.sensortechnics.com COMMON PERFORMANCE CHARACTERISTICS Vs = 5.0 ± 0.01 V, tamb = 25°C (unless otherwise noted) scitsiretcarahC. niM. pyT. xaMt inU ecrofgnitarepO0 0 051g tesffoerusserporeZ5 1-5 1+ VmnapS 2 0510 810 12 )C°05-0(stceffeerutarepmeT 4 tesffO5 .0± napS0 022- C°/mpp ecnadepmiegdirbnostceffeerutarepmeT 4 0022+ )LSB(ytiraeniL 3 7.0±5 .1± naps% siseretsyhlacinahceM 5 5.0± g003taytilibataepeR 5 5.1±V m ecnadepmitupnI0 .40 .50 .6 kΩ ecnadepmituptuO0 .40 .50 .6 )regnulpdnaslanimret,tcatnoctcerid(DSE8 V k )C°05taeruliafotselcycniam(FTCM0 2s elcycnoillim Specification notes: The maximum specified force which may be applied to the sensor without causing a permanent change in the output characteristics. Span is the algebraic difference between the output voltage at full-scale force and the output at zero force. Span is ratiometric to the supply voltage. Linearity (BSL), the deviation of measured output at constant temperature (25°C) from "Best Straight Line" determined by three points, offset pressure, full-scale pressure and half full-scale pressure. Error band of the offset voltage, span or bridge impedance in the specified temperature range, relative to the 25°C reading. Repeatability, the deviation in output readings for successive application of any given input force (all other conditions remaining constant. Hysteresis, the error defined by the deviation in output signal obtained when a specific force point is approached first with increasing force, then with decreasing force or vice versa (all other conditions remaining constant).

www.sensortechnics.com OUTLINE DRAWING mass: 2 g dimensions in mm (inches) Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights n or the rights of others. .ONTRAPE LYTSGNIGAKCAP TSN0051SSF) 001foselpitlum(ebut BSN0051SSFk capretsilb RSN0051SSF )0051foselpitlum(leerdnaepat

ORDERING INFORMATION

6.10 (0.24) 0.50 (0.02)1.57 (0.06) 3.25 (0.13) 9.14 (0.36) 4x 2.54 (0.10) 4x 0.76 (0.03) 3.81 (0.15) 5.59 (0.22) 4x 0.25 (0.01) 0.76 (0.03) Pin 1 is designated by the laser marked surface Pin 1