FSP202-1K20M1 FSP | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

DESCRIPTION

This series of AC-DC switching power supplies in a package of 3 x 5 x 1.5 inches are capable of delivering 200 watts of continuous power at 5.3 CFM forced air cooling or 150 watts at convection cooling. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking. A cover-and-fan assembly can be added during manufacturing for 200 watt output. They are specially designed for medical applications, but not for life-supporting equipment. The units are certified also to IEC /EN /UL /CSA 60950-1 and suitable for data networking, computer and telecommunication applications.

FEATURES

3 x 5 inch footprint with 1.5 inch low profile 100-240 VAC input with active PFC Less than 220 μA leakage current Meet EN55011 /55022 and FCC Class B Power Factor 0.98 typical Short-circuit protection Power Fail Detect (PFD) signal Inhibit - TTL high to disable output Compliant with RoHS requirements Efficiency greater than 87% WATTAGE Wattage: 200W DIMENSION Dimension: 127.0mm(L) x 76.0mm(W) x 38mm(H) INPUT SPECIFICATION Input Range: 90-264 Vdc Input Frequency: 47-63 Hz Input Current: 2.5A(rms) for115VAC, 1.25A(rms) for230VAC Leakage Current: 220 µA max. @ 264 VAC,63 Hz SAFETY STANDARD APPAOVAL OUTPUT SPECIFICATION Ripple & Noise: Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us after a 25% step load change Over Current Protection: Output protected to short circuit conditions ENVIRONMENTAL SPECIFICATION TEMP.Range: Operating Temperature:0°C to +70°C Storage Temperature: -40°C to + *Output Voltage and Current Rating +12V1 Ripple-Noise(R-P) mV 120mV Regulation Load % ±2% Output Max.(A) 16.67A Output Min.(A) NOTES 1. Suffix “B” in model numbers denotes U-bracket form. Change suffix “B” to “C” for enclosed form with cover and fan assembly, e.g. PM202-14C 2. 150 W without moving air or 200 W with 5.3 CFM forced air provided by user for “B” version, 200 W for “C” version with cover and fan assembly. The adequacy of cooling air is judged by the measured core temperature of transformer T1 below 75 at 25 ambient, or below100 at 50 ambient. 3. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the output. MECHANICAL SPECIFICATION This content is subject to change, please refer to specification for more detail. FSP reserve the right to change the content without prior notice Medical PSU FSP202-1K20M1