Features

  • Non contact actuation
  • High tolerance to misalignment
  • High switching current (up to 2A)
  • Various contact arrangements
  • Terminal connections Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1 Category Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems Approvals CE marked for all applicable directives and cULus Reed Contacts Safety Auxiliary Operating Distance – Make FRS3 FRS4 FRS5 12mm (0.47in) 21mm (0.83in) 12mm (0.47in) 13mm (0.51in) 12mm (0.47in) NA Operating Distance – Break FRS3 FRS4 FRS5 23mm (0.91in) 24mm (0.94in) 23mm (0.91in) 10mm (0.39in) 12mm (0.47in) NA Closing Time 3.0ms 0.5ms Dropout Time 2.1ms 0.3ms Bounce Time 0.7ms 0.7ms Initial Contact Resistance 15m Ω 10mΩ Initial Capacitance, T erminal to T erminal 0.65pF 0.2pF Initial Insulation Resistance Te r m i n a l t o Te r m i n a l1.x.10 6 Ω 1x106 Ω Safety Contact Switching Capability 250V AC 2A max Safety Contact External Fusing ≤1.6A quick blow Auxiliary Contact Switching Capability 300V DC, 250V AC, 0.5A including inrush. 15VA/10W suitable for AC/DC circuits Min Initial Breakdown Voltage 600V AC 600V AC Operating T emperature -10°C to +65°C (14° to 149°F) Enclosure Protection IP65 (NEMA 13) Case Material Red moulded ABS Plastic Mounting Any Position M4 mounting security screws included. Electrical Life 1 x 10 6 at rated loaded Mechanical Life 10 x 106 Vibration 10 to 200Hz Shock 50g

Ferrogard 3, 4 & 5 Product Selection Note: Contacts are described with the guard door closed, that is, actuator in place. Accessories Approximate Dimensions—mm (inches) Dimensions are not intended to be used for installation purposes. Typical Wiring Diagrams Application Details See page 3-54 for operating principles and mounting examples. Safety Contact Switching Capability Connection Housing Material Safety Contacts Auxiliary Contacts T ype Catalogue Number 250VAC 2A T erminals ABS Plastic 1 N.C. 1 N.C. FRS 3 440N-G02003 1 N.O. FRS 4 440N-G02008 None FRS 5 440N-G02009 Description Page Number Catalogue Number Replacement Actuator — 440N-A02005 = = Switch

2 Holes

4 Through

50 (1.97) 6 (0.24) 36 (1.41) 38.5 (1.52) 57 (2.24) 38 (1.5) 6 (0.24) 25 (0.98) 69 (2.72) 30 (1.18) 4 (0.16) (0.31) 60 (2.36) 19.5 (0.77) (0.2) 76 (2.99) 15 (0.59) 5 (0.2) 2 (0.08) 7 (0.28) FRS 3 FRS 4 FRS 5 Safety N.C. Fuse Externally Safety N.C. Fuse Externally Safety N.C. Fuse Externally Aux N.C. Aux N.O.