Features
/square4 Conforms to ETSI EN 300 220-3 and EN 301 489-3 /square4 Conforms to Indian low power requirements for 865 - 867 MHz band /square4 High performance PLL synthesizer /square4 +26dBm RF power output /square4 Data rates up to 20 kbps for standard module /square4 Usable range over 3km /square4 Fully screened. Low profile /square4 Feature-rich interface (RSSI, analogue and digital baseband) /square4 Re-programmable via RS232 interface
Applications
/square4 Asset tracking systems /square4 Industrial telemetry and telecommand /square4 High performance security system /square4 Fire alarms /square4 ROV control applications /square4 High speed data modems Technical Summary /square4 Operating frequency: 868 – 870MHz (EU), 865 - 867MH z (India) /square4 Maximum of 8 channels (depends on band allocation and data rate) /square4 Transmit power: 400mW (+26dBm) nominal /square4 Supply range: +5V regulated /square4 Current consumption: 500mA (at 400mW output) transm it, 50mA receive /square4 Data bit rate: 20kbps max. (standard module) /square4 Receiver sensitivity: -115dBm for 12dB SINAD (20kbps variant) -117dBm for 12dB SINAD (10kbps variant) /square4 Size: 67 x 30 x 12mm Evaluation Platform : Narrow Band Evaluation Kit FPX3 is a small, high power (half-watt) multi - channel wide band FM transceiver, operating in the Europe-wide 869.40 - 869.65MHz sub - band. It is also available in the Indian licence free 865-867MHz band (General telemetry and RFID). Figure 1: FPX3-869-20 400mW Multichannel 869MHz band transceiver Hartcra n House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com Issue 3, 7 April 2016FPX3
Radiometrix Ltd page 2 FPX3 Data Sheet Figure 2: FPX3 block diagram
Radiometrix Ltd page 3 FPX3 Data Sheet Pin Description NOTES: 1. No inversion occurs between TXD and RXD. 2. P1 - P3 (parallel channel selects) and N_TXE are active LOW and have internal 47K pullups to 4v 3. RXD is an open collector output, with a weak pul lup to 4v (approx 50K) 4. This radio has no 'internal modem' functions in this version. 5. Programming port (P0) operates at 2400 baud. (Co mmand set specific to this design). The unit is capable of operating in 'basic' parallel channel select only mode, or in serial controlled 'expanded' mode 6. The high current (500mA maximum) transmitter sup ply (5v regulated) is fed to a separate pin, on the RF out connector. The V supply (pin 4 on the user connector) also requires a 5v regulated supply, and draws up to 50mA Both pins must be supplied at all times (most users connect them to a common +5v supply) 7. 10% duty cycle: While the FPX3 is capable of tra nsmitting continuously (the case temperature will rise noticeably) this will be in contravention of the sub-band restrictions. Units operating in the high power 869.4-869.65MHz sub-band are limited to 10% maximum transmit duty cycle. It is the responsibility of the user to ensure that this restriction is complied with. Alternatively, the user may wish to implement a listen-before-talk protocol (using the RSSI output). See EN300-220 for further details Pins Normal mode RF 1A NO PIN 2A RF in/out To the antenna 3A RF Gnd RF ground 4A GND 0V 5A GND 0V 6A Vcc (TX) +5V regulated supply for TX 7 User
1 TXD DC coupled input for 5v pp CMOS logic wavefor ms
2 TXE Transmit enable. Low = TX mode
3 GND 0V
4 Vcc DC supply input (+5V regulated) 8
5 P3 Parallel channel select
6 P2 Parallel channel select
7 P1 Parallel channel select
8 PGM in Serial programming/control input (inverted logic level RS232)
9 RSSI DC level between 0.5V and 2.5V. 60dB dynami c range 10 RXD Open collector output of data slicer. 47K pu llup to 4V 11 AF out 500mV p-p audio. DC coupled, approx 0.8V bias Figure 3: FPX3 footprint (Top) view
Radiometrix Ltd page 4 FPX3 Data Sheet Serial interface commands Serial data is sent to the unit on the programming input (PGM). To successfully program the unit, it must be powered Unlike earlier Radiometrix multichannel units, the FPX3 has separate N and R registers for each channel, on transmit and on receive. In other words, the frequency of each channel is individually programmed in every mode. Commands include: Commands Function GOCHAN a serial select of channel a (ch0 to 7) SETPAR channel selected by 3 bit parallel input SETSER channel selected by most recent 'gochan' operation <cr> process entry / clear all buffers # disable command mode Most users will not need to edit the table which relates channel frequency, channel number and synthesizer register programming values. The commands below are used to access the eeprom table containing this information. Users should be warned that, in order to get the optimum switching speed from the module, the standard channel setup uses a different reference frequency for each channel, and the absolute calculated channel frequency is allowed to deviate by up to +/-2KHz from the nominal LOADaa nnnnn (aa = 0 – 7) load the N values for receive operation LOADaa rrrrr (aa = 8 – 15) load the R values for receive operation LOADaa nnnnn (aa = 16 – 23) load the N values for transmit operation LOADaa rrrrr (aa = 24 – 31) load the R values for transmit operation Reference frequency (10MHz/R) must be in the range 210 to 300KHz (tx) or 175 to 300KHz (rx). As a rule of thumb, an R value greater than 45 (tx) or 55 (rx) should be viewed with suspicion. a = single digit channel number from 0 to 7 aa = eprom location number from 0 to 31 nnnnn = a synthesizer N register value, (up to 65535) rrrrr = the synthesizer R register value, (up to 16383) ALL COMMANDS MUST BE IN UPPER CASE. Notice that the synthesizer and VCO operate at half the output frequency, so for a frequency of 869.475MHz, the actual N/R values will be set for 434.7375MHz Further information TBA NOTE: /square4 A pause of at least 50ms must be allowed between command strings (EEPROM programming time)
Radiometrix Ltd page 5 FPX3 Data Sheet Condensed specifications Frequency 868 – 870MHz (EU) 865 - 867MHz (India) Frequency stability +/-5ppm (better than ±5kHz) Channel spacing 100kHz (FPX3-86x-20) 50kHz (FPX3-86x-10) Number of channels 8 maximum FPX3-869-20 for EU CH0: 869.475MHz, CH1-CH3: 869.565MHz CH4-CH7=869.50MHz for backward compatibility FPX3-869-10 for EU CH0:869.450MHz, CH1:869.500MHz, CH2:869.550MHz, CH3:869.600MHz, CH4-CH7=869.50MHz for backward compatibility FPX3-866-10 or FPX3-866-20 for India CH0 = 865.143 MHz CH1 = 865.294 MHz CH2 = 865.500 MHz CH3 = 865.789 MHz CH4 = 866.047 MHz CH5 = 866.383 MHz CH6 = 866.531 MHz CH7 = 866.829 MHz Supply Receive 5.0V regulated at 50mA Transmit: 5.0V regulated at 500mA for 400mW output Operating temperature -20 to +70 οC (Storage -30 to +70 οC) Spurious radiations Compliant with ETSI EN 300 220- 2 and EN 301 489-3 (EU) Interface User 11 pin 0.1" pitch molex RF and TX supply 5 pin 0.1" pitch molex Recommended PCB hole size 1.2mm (min.) Size 67 x 30 x 12mm Transmitter Output power 400mW (+26dBm) TX on switching time 5 ms Modulation type FM, FSK (F1D, F3D) TX modulation bandwidth DC – 10kHz Peak FM Deviation ±16kHz nominal (FPX3-xxx-20) ±8kHz nominal (FPX3-xxx-10) Adjacent channel TX power -37dBm TX spurii <-36dBm Inputs 5V pk-pk CMOS data Receiver Sensitivity -117dBm for 12dB SINAD at 1KHz (FPX3-xx x-10) -115dBm for 12dB SINAD at 1KHz (FPX3-xxx-20) -107dBm for <0.1% data errors (20kbps NRZ) image / spurious -55dB blocking -80dB adjacent channel -60dB (Tested per. ETSI 300-220-2) Outputs RSSI, Audio, Data
Ordering Information
Part No. Description Frequency band (MHz) FPX3-869-10 10kbps, 4-channel EU version 869.40 – 8 69.65 MHz FPX3-869-20 20kbps, 2-cannnel EU version 869.40 – 8 69.65 MHz FPX3-866-10-IND 10kbps, 8-channel Indian version 86 5 – 867 MHz FPX3-866-20-IND 20kbps, 8-channel Indian version 86 5 – 867 MHz
Radiometrix Ltd page 6 FPX3 Data Sheet Appendix [mW] [MHz] RF POWER [ERP] 100 500 600kHz 500kHz 250kHz 300kHz 25mW 25mW CEPT/ERC Rec 70-03, 868 MHz Band Plan 868.0 868.60 868.70 869.20 869.25 869.30 869.65 869.40 870.0 869.70 <1% or LBT No Spacing Non-specific SRD Non-specific SRD Non-specific SRD No Spacing up to 100% <0.1% or LBT <1% <10% or LBT <10% No Spacing 25kHz or Wide Band 25kHz Alarm Alarm <1% 25kHz or WB Alarm Social Alarm 10mW 25kHz <0.1% 100kHz 25mW 10mW 50kHz 50kHz 10mW Non-specific SRD 25kHz 50kHz
231 Kenton Lane
Harrow, Middlesex HA3 8RP ENGLAND Tel: +44 (0) 20 8909 9595 Fax: +44 (0) 20 8909 2233 sales@radiometrix.com www.radiometrix.com Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice. Radiometrix Ltd does not assume any liability arising from the application or use of any product or circuit described herein, nor for any infringements of patents or other rights of third parties which may result from the use of its products. This data sheet neither states nor implies warranty of any kind, including fitness for any particular application. These radio devices may be subject to radio interference and may not function as intended if interference is present. We do NOT recommend their use for life critical applications. The Intrastat commodity code for all our modules is: 8542 6000 R&TTE Directive After 7 April 2001 the manufacturer can only place finished product on the market under the provisions of the R&TTE Directive. Equipment within the scope of the R&TTE Directive may demonstrate compliance to the essential requirements specified in Article 3 of the Directive, as appropriate to the particular equipment. Further details are available on The Office of Communications (Ofcom) web site: http://www.ofcom.org.uk/ Information Requests Ofcom Riverside House 2a Southwark Bridge Road London SE1 9HA Tel: +44 (0)300 123 3333 or 020 7981 3040 Fax: +44 (0)20 7981 3333 information.requests@ofcom.org.uk European Communications Office (ECO) Peblingehus Nansensgade 19 DK 1366 Copenhagen Tel. +45 33896300 Fax +45 33896330 ero@ero.dk www.ero.dk