FL1F-H12RCE IDEC | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
With an ever-changing market and tough competition, you need an edge to stay on top. This sixth-generation IDEC SmartRelay meets your demands from all small-scale applications by offering more powerful hardware, a new display and full communication options via Ethernet. BASE MODULE HIGHLIGHTS Embedded RJ45 Ethernet Port
- Remote program download, upload and monitor
- Integrated web server for remote monitoring and control Micro SD Card
- Equipped with micro SD slot for program storage, transfer and data logging
- No need for a special memory cartridge Data Logging
- Up to 20,000 lines in a file with a maximum of 50 files can be stored in the Micro SD Memory card Web Page Editor and Web Server
- Easily monitor and control web pages with no HTML knowledge
- Instant monitoring and control using standard web browser like Chrome, IE and Firefox
- View and control I/O status, timer, counters, analog set point and more There's an App for that!
- Download iOS and Android App for free
- Using the SmartRelay App, users can view and control any I/O status, timer, counters, and analog set point anywhere and at any time Microsoft Excel Access Tool
- Easily communicate directly with Excel to view, trace, update and log FL1F SmartRelay variables 6th-Generation IDEC SmartRelay BASE MODULE GENERAL SPECIFICATIONS Item Specifications Standard Operating Temperature Horizontal Mounting -20 to 55°C (no freezing) Cold: IEC60068-2-1 Hot: IEC60068-2-2Vertical Mounting -20 to 55°C (no freezing) Storage/Transportation Temp. –40 to +70°C (no freezing) — Relative Humidity 10 to 95% (no condensation) IEC60068-2-30 Atmospheric Pressure 795 to 1080hPa — Operating Condition No corrosive gas — Degree of Protection IP20 — Vibration Resistance 5 to 8.4Hz, amplitude 3.5mm 8.4 to 150Hz, acceleration 9.8m/s² IEC60068-2-6 Shock Resistance 147m/s² IEC60068-2-27 Drop Test (packaged) 0.3m IEC60068-2-32 Emissions Limit class B Group 1 EN55011/A EN55022/B EN50081-1 Electrostatic Discharge Immunity 8kV air discharge 6kV contact discharge IEC61000-4-2 Radiation Field Immunity Field Strength: 1V/m and 10V/m IEC61000-4-3 Fast Transient Burst 2kV (power line) 2kV (I/O signal line) IEC61000-4-4 Surge Immunity 1 (FL1F-H12RCC, FL1F-B12RCC only) 1kV (power line) normal 2kV (power line) common IEC61000-4-5 Communication Cable 2.5mm² (one wire) 1.5mm² (two wires) — Terminal Style Finger-safe type 2 — 1: For protection against surge noise on DC power supply types (FL1F-H12RCE/B12RCE, FL1F-H12SCD, FL1F-H12RCA/B12RCA), use surge absorbers, noise cut transformers or noise filters. Use of a surge protection device (DEHN + SÖHNE GmbH + Co, BVT AD 24 Part No. 918 402) is recommended. 2: Tightening torque 0.5 to 0.6N·m R USC
BASE MODULE SPECIFICATIONS Base Module Type No. FL1F-H12SCD FL1F-H12RCE FL1F-B12RCE FL1F-H12RCA FL1F-B12RCA FL1F-H12RCC FL1F-B12RCC Power Supply Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC Rated Frequency — — 47 to 63Hz 47 to 63Hz Current Draw 15 to 50 mA (24V DC) 1.2A (with max. load on digital output) 30 to 140 mA (12V DC) 15 to 90 mA (24V DC) 15 to 150mA (12V DC) 15 to 130mA (24V DC) 15 to 40mA (100V AC) 5 to 10mA (100V DC) 15 to 25mA (240V AC) 2 to 8mA (240V DC) Allowable Momentary Power Interruption — 2ms Typ. (12V DC) 5ms Typ. (24V DC) 5ms Typ. (24V AC/DC) 10ms Typ. (100V AC/DC) 20ms Typ. (240V AC/DC) Power Consumption 1.2 W (24V DC) 1.7W (12V DC) 2.2W (24V DC)
3.6 W (24V AC)
3.2 W (24V DC)
4.6W (100V AC) 1.2W (100V DC) 6.0W (240V AC) 2.0W (240V DC) Reverse Polarity Protection Yes Yes — — Clock Backup Duration 20 days 20 days 20 days 20 days Clock Accuracy ±2 sec/day (Typ.) ±2 sec/day (Typ.) ±2 sec/day (Typ.) ±2 sec/day (Typ.) Input Input Signal DC DC AC/DC AC/DC Input Points 8 (I1 to I8) 8 (I1 to I8) 8 (I1 to I8) 8 (I1 to I8) High-speed Input 1 4 (I3, I4, I5, I6), 5kHz maximum 4 (I3, I4, I5, I6), 5kHz maximum — — Analog Input Points 4 (I1, I2, I7, I8) 4 (I1, I2, I7, I8) — — Analog Input Range 0 to 10V DC (max. rated input: 28.8V DC) 0 to 10V DC (max. rated input: 28.8V DC) — — Analog Input Error ±1.5 (of full scale) ±1.5 (of full scale) — — Analog Input Resolution 10 bits (0 to 1000) 10 bits (0 to 1000) — — Cycle time 300ms 300ms 300ms 300ms Allowable Voltage Range 0 to 28.8V DC 0 to 28.8V DC 0 to 26.4V AC 0 to 28.8V DC 0 to 265V AC 0 to 253V DC Input Impedance Digital Input 5.8kΩ 5.8kΩ 4.8kΩ 610kΩ Analog Input 72kΩ 72kΩ — — Isolation — — — — Operating Range OFF Voltage < 5V DC < 5V DC < 5V AC/DC < 40V AC < 30V DC ON Voltage ≥ 12V DC ≥ 8.5 V DC ≥ 12V AC/DC ≥ 79V AC ≥ 79V DC Turn ON Time 1.5ms (Typ.) ≤ 1.0ms (I3 to I6) 1.5ms (Typ.) ≤ 1.0ms (I3 to I6) 1.5ms (Typ.) 100V AC: 40ms (Typ.) 240V AC: 30ms (Typ.) 100V DC: 25ms (Typ.) 240V DC: 20ms (Typ.) Turn OFF Time 1.5ms (Typ.) ≤ 1.0ms (I3 to I6) 1.5ms (Typ.) ≤ 1.0ms (I3 to I6) 15ms (Typ.) 100V AC: 45ms (Typ.) 240V AC: 70ms (Typ.) 100V DC: 60ms (Typ.) 240V DC: 75ms (Typ.) Wire Length 2 100m 100m 100m 100m Output Output Signal Transistor source output Relay output Relay output Relay output Output Points/ Contact Configuration 4 points (separate) 4NO contacts 4NO contacts 4NO contacts Isolation — Isolated Isolated Isolated Dielectric Strength (between power/input terminals and output terminals) — 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute Output Voltage External power voltage — — — Maximum Load Current 0.3A maximum Resistive load 10A at 12/24V AC/DC 10A at 100/120V AC 10A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Resistive load 10A at 12/24V AC/DC 10A at 100/120V AC 10A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Resistive load 10A at 12/24V AC/DC 10A at 100/120V AC 10A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Surge Current — 30A maximum 30A maximum 30A maximum Short-circuit Protection Built-in current limiting resistor: Approx. 1A External fuse required: 16A maximum External fuse required: 16A maximum External fuse required: 16A maximum Minimum Switching Load — 10mA, 12V DC (reference value) 10mA, 12V DC (reference value) 10mA, 12V DC (reference value) Initial Contact Resistance — 100mΩ maximum (at 1A, 24V DC) 100mΩ maximum (at 1A, 24V DC) 100mΩ maximum (at 1A, 24V DC) Mechanical Life — 10 million operations (no load, 10Hz) 10 million operations (no load, 10Hz) 10 million operations (no load, 10Hz) Electrical Life — 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour 1 When selecting frequency trigger function and up/down counter function. 2 10m when connected to analog input (twisted pair cable) Initialization Time: After power-up, the FL1F takes a maximum of 9 seconds (when using a micro SD card) for initialization. When initialization is complete, the FL1F is automatically set to RUN mode.
EXPANSION I/O MODULE SPECIFICATIONS Expansion I/O Module Type No. FL1F-M08B1S2 FL1F-M08B2R2 FL1F-M08D2R2 FL1F-M08C2R2 FL1F-J2B2 FL1F-K2BM2 Power Supply Rated Power Voltage 24V DC 12/24V DC 24V AC/DC 100 to 240V AC/DC 12/24V DC 24V DC 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC 10.8 to 28.8V DC 20.4 to 28.8V DC Rated Frequency — — 50/60Hz (47 to 63Hz) 50/60Hz (47 to 63Hz) — — Current Draw 15 to 40mA 10 to 80mA (12V DC) 10 to 40mA (24V DC) 20 to 100mA (24V AC) 8 to 50mA (24V DC) 10 to 30mA (100V AC) 10 to 20mA (240V AC) 5 to 15mA (100V DC) 5 to 10mA (240V DC) 15 to 30mA 15 to 82mA Allowable Momentary Power Interruption — 2 ms (typ.) (12V DC) 5 ms (typ.) (24V DC) 5 ms (typ.) (24V AC/DC) 10ms (typ) (100V AC/DC) 20ms (typ.) (240V AC/DC) 10ms (typ.) (12/24V DC) 10ms (typ.) Power Consumption 1.0W 1.0W (12V DC) 1.0W (24V DC) 2.4W (24V AC) 1.2W (24V DC) 3.5W (100V AC) 1.8W (100V DC) 4.8W (240V AC) 2.4W (240V DC) 0.4W (12V DC) 0.8W (24V DC) 2.0W Reverse Polarity Protection Yes Yes — — Yes Yes Input Input Signal DC input DC input AC/DC input AC/DC input Analog input — Input Points 4 4 4 4 — — 20.4 to 28.8V DC 85 to 265V AC 100 to 253V DC — — Operating Range OFF Voltage < 5V DC < 5V DC < 5V AC/DC < 40V AC < 30V DC — — ON Voltage ≥ 12V DC ≥ 8.5V DC ≥ 12V AC/DC ≥ 79V AC ≥ 79V DC — — OFF Current < 0.88mA < 0.88mA < 1.1mA < 0.05mA (AC) < 0.06mA (DC) — — ON Current ≥ 2.1mA ≥ 1.5mA ≥ 2.63mA ≥ 0.08mA (AC) ≥ 0.13mA (DC) — — 100V AC: 40 ms (typ.) 240V AC: 30 ms (typ.) 100V DC: 25 ms (typ.) 240V DC: 20 ms (typ.) — — 100V AC: 45 ms (typ.) 240V AC: 70 ms (typ.) 100V DC: 60 ms (typ.) 240V DC: 75 ms (typ.) — — Analog Input Points — — — — 2 — Analog Input Range — — — — 0 to 10V (max. rated input: 28.8V) 0 to 20mA (max. rated input: 40mA) Digital Resolution — — — — 10 bits (0 to 1000) — Input Error — — — — ±1.5% (of full scale) — Input Impedance — — — — 76kΩ (0 to 10V) 250Ω (0 to 20mA) — Sampling Cycle — — — — 50ms — Output Wire Length 100m 100m 100m 100m 10m (twisted-pair shielded cable) — Output Signal Transistor source output Relay output Relay output Relay output — — Output Points/ Contact Configuration 4 points (separate) 4NO contacts 4NO contacts 4NO contacts — — Isolation — Isolated Isolated Isolated — — Dielectric Strength (between power/input terminals and output terminals) — 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute 2500V AC, 1 minute 500V DC, 1 minute — — Output Voltage External power voltage Maximum Load Current 0.3A maximum Resistive load 5A at 12/24V AC/DC 5A at 100/120V AC 5A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Resistive load 5A at 12/24V AC/DC 5A at 100/120V AC 5A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Resistive load 5A at 12/24V AC/DC 5A at 100/120V AC 5A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC Inductive load 2A at 12/24V AC/DC 3A at 100/120V AC 3A at 230/240V AC 0.2A at 120V DC 0.1A at 240V DC — — Short-circuit Protection Built-in current limiting resistor: Approx. 1A External fuse required: 16A maximum External fuse required: 16A maximum External fuse required: 16A maximum — Yes Minimum Switching Load — 10mA, 12V DC (reference value) 10mA, 12V DC (reference value) 10mA, 12V DC (reference value) — — Initial Contact Resistance — 100mΩ maximum (at 1A, 24V DC) 100mΩ maximum (at 1A, 24V DC) 100 mΩ maximum (at 1A, 24V DC) — — Mechanical Life — 10 million operations (no load, 10Hz) 10 million operations (no load, 10Hz) 10 million operations (no load, 10Hz) — — Electrical Life — 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour 100,000 operations (rated resistive load) 1800 operations/hour — — Analog Output Points — — — — — 2 Analog Output Range — — — — — Voltage: 0-10V DC Current: 0-20, 4-20 mA Digital Resolution — — — — — 10 bits (0 to 1000) Output Error (of full scale) — — — — — Voltage output: ±2.5% Current output: ±3% Output Impedance — — — — — Voltage: 5kΩ min Current: 250Ω max Analog Value Conversion Interval — — — — — 50ms (typ.) Wire Length — — — — — 10m (twisted-pair shielded cable)
TEXT DISPLAY PANEL HIGHLIGHTS: New and improved LCD display
- Improved display with 6 lines and 20 characters per line, more than twice as many characters as before
- Selectable white, amber or red backlighting for optical emphasis on alarms and events Two RJ45 Ethernet ports
- Use a standard Ethernet cable to the connect FL1F base module to the Text Display Panel. A special cable is not required.
- Provide different ways to connect Text Display General Specifications Item Specifications Standard Operating Temperature Horizontal Mounting 0 to 55°C (no freezing) Cold: IEC60068-2-1 Hot: IEC60068-2-2Vertical Mounting 0 to 55°C (no freezing) Storage/Transportation Temp. –40 to +70°C (no freezing) — Relative Humidity 10 to 95% (no condensation) IEC60068-2-30 Atmospheric Pressure 795 to 1080hPa — Operating Condition No corrosive gas — Degree of Protection IP20 — Vibration Resistance 5 to 8.4Hz, amplitude 3.5mm 8.4 to 150Hz, acceleration 9.8m/s2 IEC60068-2-6 Shock Resistance 147m/s2 IEC60068-2-27 Drop Test (packaged) 0.3m IEC60068-2-32 Emissions Limit class B Group 1 EN55011/A EN55022/B EN50081-1 Electrostatic Discharge Immunity 8kV air discharge 6kV contact discharge IEC61000-4-2 Radiation Field Immunity Field Strength: 1V/m and 10V/m IEC61000-4-3 Fast Transient Burst 2kV (power line) 2kV (I/O signal line) IEC61000-4-4 Surge Immunity 1 (FL1F-H12RCC, FL1F-B12RCC only) 1kV (power line) normal 2kV (power line) common IEC61000-4-5 Communication Cable 2.5mm2 (one wire) 1.5mm2 (two wires) — Terminal Style Finger-safe type 2 —
1 For protection against surge noise on DC power supply types (FL1F-H12RCE/B12RCE, FL1F-H12SCD, FL1F-
H12RCA/B12RCA), use surge absorbers, noise cut transformers, or noise filters. Use of a surge protection device (DEHN + SÖHNE GmbH + Co, BVT AD 24 Part No. 918 402) is recommended. 2 Tightening torque 0.5 to 0.6N·m Text Display General Specifications Cont. Dimensions (W × H × D) 128.2 × 86 × 38.7 mm Weight (approx.) 220g Installation Panel cut-out using mounting clips Keyboard Membrane keypad Display FSTN graphic display (W × H: 160 × 96 dots) LED backlight (White, Amber, Red) Font type English, Spanish, Russian, Chinese, Italian, Turkish, German, Dutch, French, Japanese Displayable string 1 screen 6 lines × 20 columns Power Supply Specifications Power Voltage 24V AC/DC 12V DC Allowable Voltage Range 20.4 to 26.4V AC 10.2 to 28.8V DC Allowable Voltage Frequency 47 to 63Hz Power Consumption 12V DC: 145mA (Typ.) 24V DC: 70mA (Typ.) 24V AC: 75mA (Typ.) Data Transmission Rate 10/100M full/half duplex data transmission rate LCD Display / Backlight Specifications LCD Display Durability 3 50,000 hours Backlight Durability 4 20,000 hours
3 Display durability is calculated under ordinary operating and storage conditions: room temperature,
normal humidity below 65% RH, and not subjected to direct sunlight. 4 Backlight durability is the number of hours taken for the light to become 50% of the original brightness. TEXT DISPLAY SPECIFICATIONS
Rated Power Voltage Input Signal Output Signal Display Clock I/O Points Weight (approx.) Part No. 24V DC DC I1, I2, I7 and I8 are used for digital/ analog inputs Transistor Yes Yes 8/4 points 195g FL1F-H12SCD 12/24V DC Relay Yes Yes 8/4 points 240g FL1F-H12RCE — 200g FL1F-B12RCE 24V AC/DC AC/DC Relay Yes Yes 8/4 points 240g FL1F-H12RCA — 200g FL1F-B12RCA 100 to 240V AC/DC AC/DC Relay Yes Yes 8/4 points 240g FL1F-H12RCC — 200g FL1F-B12RCC 1 With NPN/PNP sensor input. For details, see Input Internal Circuits in the Specifications table. Expansion I/O Module Type Rated Power Voltage Input Signal Output Signal I/O Points Weight (approx.) Part No. Input/Output 24V DC DC Transistor 4/4 points 95g FL1F-M08B1S2 12/24VDC DC Relay 4/4 points 130g FL1F-M08B2R2 24V AC/DC 2 AC/DC 2 Relay 4/4 points 130g FL1F-M08D2R2 100 to 240V AC/DC AC/DC Relay 4/4 points 130g FL1F-M08C2R2 Analog Input 12/24V DC Analog — 2/0 points 95g FL1F-J2B2 Analog Output 24V DC — Analog 0/2 points 95g FL1F-K2BM2 2 With NPN/PNP sensor input. For details, see Input Internal Circuits in the Specifications table. I/O points within the maximum number of expandable I/O points can be used. When using modules of the same power voltage, supply power to the base module and expansion I/O modules using one power supply. When power is supplied to the modules from different power supplies, the fast transient burst is 1 kV (IEC61000-4-4). Text Display Rated Power Voltage Weight (approx.) Part Number Remarks 24V AC/DC 12V DC 220g FL1F-RD1 Supplied with mounting clip and gasket Options Description Part Number Package Quantity Remarks Mounting Clip for Base Module FL1F-PSP1PN05 5 Supplied with a module 3 Mounting Clip and Waterproof Gasket for Text Display FL1F-KW1 1 Supplied with text display 4 IDEC SmartRelay User’s Manual (English) FL9Y-B1789 1 Downloadable from: http://www.idec.com/download 3 Supplied with a base module and an expansion module. 4 Supplied with a text display, it includes a gasket, four mounting clips, and a power supply connector. NEW FUNCTION BLOCKS Analog filter Sn=8 AQ AX Sn 1 2 3 4 5 6 7 8 9 10 ... Sn=8 Sn=8Sn=8Sn=8Sn=8Sn=8 Ax AQAx Astronomical clock Monday TR TS TR TS TR TS Q Tuesday Wednesday... TaTa Ta AC Q Max/Min .PEF *G&3TU Stopwatch En R AQ LapT CurT Lap Sw AQ En Lap R Average value Sn=8 St=10s Sn=8 St=10s AX En R AQ Sn 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Ax AQ En R Ax Ax AQ En Ax
DIMENSIONS (All dimensions in mm) Note: Drawings are not to scale Mounting Hole Layout (Using Mounting Slides) +0.2 35.5 -0.0 +0.2 35.5 -0.0 +0.2 35.5 -0.0 +0.2 35.5 -0.0 +0.2 53.5 -0.0 +0.2 35.5 -0.0 +0.2 n x 35.5 -0.0 98 +/- 0.3 ➀ ➁ ➁ ➁ ➁ ➁ ➁ ➁ Text Display 77.6 38.7 34.7 31.9 128.2 (Panel Cutout) 119.0+0.5mm 78.5+0.5mm Mounting clip Mounting screws (tightening torque: 0.15 to 0.2N·m) Panel (thickness: 1.5 to 4mm) Mounting clip Gasket Base Module (with Display) 71.5 Base Module (without Display) 71.5 Expansion I/O Module 35.5 Base Module (with Display) Base Module (without Display) Expansion I/O Module IDEC Corporation • 1175 Elko Drive • Sunnyvale, CA 94089 • 800-262-IDEC (4332) • Fax: 408-745-5258 • www.IDEC.com/usa ©2015 IDEC Corporation. All Rights Reserved. FL9Y-DS100-2 12/19 2.5K