400 Watts

  • 400 W Continuous, 600 W Peak
  • IT and Medical Approvals
  • 80 V - 275 VAC Operation
  • Low Noise Fan
  • Screw Terminals
  • 5 V Standby, AC OK and Remote On/Off
  • 3 Year Warranty FCM Series Input Input Voltage • 80-275 VAC, derate output power <90 VAC (see derating curve) Input Frequency • 47-63 Hz Input Current • 4.1 A at 115 VAC typical

2.1 A at 230 VAC with 400 W load

Inrush Current • 60 A max at 264 VAC, cold start 25 °C Power Factor • >0.9 Earth Leakage Current• 260 µA max, 264 VAC, 60 Hz Input Protection • F10 A / 250 V internal fuse in line and neutral Output Output Voltage • 12-48 VDC (see tables) Output Voltage Trim • ±10% V1 Initial Set Accuracy• ±1% V1, ±5% V2 Minimum Load • No minimum load required Start Up Delay • 1 s typical Start Up Rise Time • 50 ms Hold Up Time • 20 ms minimum Line Regulation • ±0.5% maximum Load Regulation • ±1% V1, ±5% V2 Transient Response • 4% max. deviation, recovery to within 1% in 500 µs for a 50-75-50% load change Ripple & Noise • 1% pk-pk, 20 MHz bandwidth Overvoltage Protection• 115-140% Vnom, recycle input to reset Overtemperature • Auto reset Protection Overload Protection • 150-165%, V1 only Short Circuit Protection• Continuous, approximately constant current Temperature • 0.05% / °C Coefficient Remote On/Off • Uncommitted isolated optocoupler diode, powered diode inhibits V1 & Fan xppower.com General Efficiency • 85% typical Isolation • 4000 VAC input to output, 2 x MOPP,

1500 VAC input to ground, 1 x MOPP,

500 VAC output to ground

Switching Frequency • PFC 70 kHz, main converter 65 kHz typical Power Density • 8.6 W/in3 Signals • AC OK, remote on/off, 5 V standby MTBF • 236 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature• -10 °C to +70 °C, derate linearly from +50 °C at 2.5% / °C to 50% load at +70 °C Cooling • Forced cooled with integral fan Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 kHz, 3 axes EMC & Safety Emissions • EN55011/22 level B conducted EN55011/22 level A radiated Harmonic Currents • EN61000-3-2, class A EN61000-3-2, class C for loads ≥50% Voltage Flicker • EN61000-3-3 Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, installation class 3, Perf Criteria A Conducted Immunity • EN61000-4-6, level 3, Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B, EN60601-1-2, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A, A, B - 230 VAC. Consult longform datasheet for 115 V operation Safety Approvals • IEC60950-1 CB report, UL60950-1, TUV, EN60950-1, IEC60601-1 CB report, CSA 22.2 No.60601-1, ANSI/AAMI ES60601-1, TUV60601-1, including risk management

  1. Peak Output Power - The peak duration is 500 ms maximum, average power must not exceed 400 W. OUTPUT VOL TAGE ADJUSTMENT OUTPUT TERMINALS M4 SCREWS IN 2 POSITIONS. TORQUE TO 90 cNm Max. SIGNALS CONNECTOR CON8 10-WAY JST -BIOB-PDHSS OUTPUT TERMINALS ALLOW CONNECTION FROM EITHER TOP OR SIDE 6.00 ±0.02 (152.4 ±0.5) 1.93 ±0.02 (49.0 ±0.5) 4.00 ±0.02 (101.6 ±0.5) 0.96 (24.3) 2.10 (53.4) 3.35 (85.0) INPUT CONNECTOR Pin 9 NOT INCLUDING OUTPUT TERMINAL SCREWS HEIGHT INCLUDES EMBOSSED FAN COVER Pin 10 Pin 1Pin 2 M3 MOUNTING HOLES (IN 2 POSITIONS). MAX. PENETRATION BY SCREW TO BE 3.5mm FROM OUTSIDE FACE OF CHASSIS 3.94 (100.0) 2.95 (75.0) 0.52 (13.3) 1.03 (26.2) M3 MOUNTING HOLES (IN 4 POSITIONS). MAX. PENETRATION BY SCREW TO BE 2.5mm FROM BOTTOM FACE OF CHASSIS 1. Dimensions shown in inches (mm). Tolerance: ±0.02 (±0.5) 2. Weight: 1.8 lb (800 g). Output Voltage V1 Output Current V1 Standby Supply V2 Output Power Model NumberContinuous Peak(1) Continuous Peak(1) 12 V 33.3 A 50.0 A 5 V / 0.5 A 400 W 600 W FCM400PS12 15 V 26.6 A 40.0 A 5 V / 0.5 A 400 W 600 W FCM400PS15 24 V 16.6 A 25.0 A 5 V / 0.5 A 400 W 600 W FCM400PS24 28 V 14.2 A 21.4 A 5 V / 0.5 A 400 W 600 W FCM400PS28 36 V 11.1 A 16.7 A 5 V / 0.5 A 400 W 600 W FCM400PS36 48 V 8.3 A 12.5 A 5 V / 0.5 A 400 W 600 W FCM400PS48 Notes Input Connector Tyco part #640445-5 Pin 1 Line Pin 2 Neutral Pin 3 Earth Output Connector Pin 1 +V1 Pin 2 V1 RTN J1 mates with Tyco MTA-156 & SL-156 product lines Mating plug: JST p/n PHDR-10VS Contact: 26-22 AWG JST p/n SPHD-001T-P0.5 Signals Connector Pin 1 5 V Standby Return Pin 2 5 V Standby Pin 3 5 V Standby Return Pin 4 5 V Standby Pin 5 5 V Standby Return Pin 6 5 V Standby Pin 7 Power Fail (Collector) Pin 8 Power Fail (Emitter) Pin 9 Remote On / Off (Cathode) Pin 10 Remote On / Off (Anode) Input Voltage & Temperature Derating 400 300 100 200 500 -10 0 50 Ambient Temperature (°C) Peak Power Availability Output Power (W) 600 10 40 60 70 400 360 300 320 540 80 85 275 Input Voltage (VAC) Peak Power Availability 600 90 264