WWW.STACOENERGY.COMTOGETHER WE POWER ON PROACTIVE BATTERY MONITORING SYSTEM FIRSTLINE BMS-II FEATURES INCLUDE Lifecycle Management - In Real Time Low Cost Ease of Installation Alarm via email & dry contact Web access - Graphic Designer Interface (GUI) Battery cycling data collection History databases Provides cell balancing Provides ethernet/RS485 for remote monitoring Full Two Year Warranty

WWW.STACOENERGY.COMTOGETHER WE POWER ON FIRSTLINE BMS-II Most battery monitoring systems were developed to allow the user to have real time feedback on the health of their battery system. The FirstLine BMS-II was developed with this in mind, however, it also allows the end user to condition and control their battery system , thus improving the life of the system. Too often a BMS is a reactionary device - discover a problem and then repair or replace the bad battery. The FirstLine BMS-II employs a Battery Analysis and Care System that constantly load levels the jars within the battery string, preventing the ill effects of diverging voltages and cell impedance. This proactive conditioning and cell balancing helps prolong the life of the battery system. PROACTIVE MONITORING AND CONTROL Modules are placed on top of the battery for temperature sensing of the module and battery case. Optional terminal temperature sensing is available upon request. Communications between the modules and controller is achieved via the RJ11 CAN connection. Optional length CAN cables are available for stepping up and down within a battery rack or between battery cabinets. IFC CODE COMPLIANCE OPTION The FirstLine BMS-II also allows the client to add the option of IFC compliance which adds a higher sense of protection for thermal runway events and can control to the battery disconnect(s) allowing the BMSII to separate the battery string from power sources in the event of a thermal event. Modules are mated with quick connect power and sensing cabling that is fused for; reverse polarity, over current and over voltage protection of the sensing and balancing module. Double tab installation, two tabs per terminal post, is required for impedance accuracy. SINGLE POINT IP CONNECTION FirstLine BMS-II allows for multiple devices to be monitored from one IP connection. The controller / web manager allows for the integration of UPS telemetry, remote contract telemetry and other devices such as ground fault detection, hydrogen detection, and smoke detection.

WWW.STACOENERGY.COMTOGETHER WE POWER ON TYPICAL UNBALANCED BATTERY SYSTEM TYPICAL FIRSTLINE BMS-II BATTERY

WWW.STACOENERGY.COMTOGETHER WE POWER ON FIRSTLINE BMS-II GENERAL SPECIFICATIONS CONTROLLER/ WEB MANAGER FLBMSII GWM Operating Temperature 0° to 60°C / 32°F to 140°F Relative Humidity 20%-95% Non-condensating Input Power Supply 120/240 VAC Power Consumption 20 Watt Max Communications Ports Ethernet (LAN) x 1 COM 1-RS 232 UPS Protocols, COM2-RS232, SNMP , MODBUS, *BACnet, *PROFIBUS, Output Dry Contact Output Port x1 24 VDC 1A Monitoring Nodes Maximum 330 nodes / modules per system Display Type GUI Web Based Dimension (H x W x D) 1.108” x 5.12” x 4.92” Weight .4 lbs *Optional PART NUMBER 2V (FBMSII-MO2V) (FBMSII-MO6V) 12V FBMSII-M12V) 16V (FBMSII-M16V) Percent Accuracy < 0.5% Impedance Range .02 - 6 mΩ ± <10% .5 - 60 mΩ ± <5% Shut Down Voltage 1.24 VDC 4.7 VDC 9.6 VDC Startup Voltage 1.65 V 4.8 VDC 9.7 VDC Storage Temperature Range 0 - 100°C / 32 - 212°F Operating Temperature Range 0 - 60°C / 32 - 140°F Relative Humidity 20% - 95% *Power Consumption < 2 W Sleep Mode <1mA Input Impedance 1MΩ Sampling Rate 1Hz (or 1 sampling interval per second) Dimension (H x W x D) .94” x 2.17” x 3.15” Weight 3.4 oz *Dependent upon Balance Charging Power Requirement DC Current Sensors FBMSII-CT0200 FBMSII-CT0400 FBMSII-CT0500 FBMSII-CT1000 FBMSII-CT1500 Current Measure Range 200 ADC 400 ADC 500 ADC 1000 ADC 1500 ADC Accuracy 10% Dimension (H x W x D) 2.99” x 4.33” x 3.54” ID Sensor Opening 1.57” x 1.18” Weight .8 lbs

WWW.STACOENERGY.COMTOGETHER WE POWER ON APPLICATIONS GENERAL SPECIFICATIONS Below is the typical application for a FirstLine BMSII system in an UPS environment. As noted, the optional IFC Compliance Module allows control over the battery cabinet circuit breaker(s) in the event of a thermal runaway. The FirstLine BMS-II Battery Monitoring System consist of a Controller / Web Manager that retrieves and stores data, Cell Monitor Modules that provide voltage, impedance and temperature of each jar or monoblock battery and (optional) Current Transformer to monitor charge and discharge current, (optional) IFC Compliance module to control the battery circuit breaker(s) upon detection of a thermal runaway, (optional) ground fault detector to alert you to service related issues such as electrolyte leakage to ground, (optional) hydrogen detection module to detect the release or presence of hydrogen, and (optional) smoke detector to alert you to a possible thermal runaway event.

WWW.STACOENERGY.COMTOGETHER WE POWER ON FIELD SERVICE PROGRAM WHY STACO ENERGY PRODUCTS? BECAUSE WE ARE YOUR TAILORED POWER SOLUTIONS PROVIDER! Unique application design demands, harsh environment concerns, the need to meet non-standard physical space requirements; providing the “not so usual” is what we do best. From leading edge uninterruptible power supplies, power conditioners, power factor and harmonic correction equipment, to the world’s most stable voltage control systems, we have the technology you need to protect and manage your business, and the knowledge to make it work for you. Since 1937, customers worldwide have relied on Staco Energy as their tailored solutions provider, to solve a wide range of electrical power problems. Headquartered in Miamisburg, Ohio, Staco Energy Products is a wholly owned subsidiary of Components Corporation of America, located in Dallas, Texas. STACO SERVICE Staco specializes in providing choice and flexibility by developing tailored solutions for preventive and remedial maintenance services, as well as emergen- cy repairs for all of our products. Staco Service is built upon a nationwide network of highly trained and motivated customer support engineers and techni- cians who can provide professional services and care throughout the life of your equipment. Start-Ups Preventive Maintenance Spare Parts Battery Analysis/Refresh/Replacement On-Site Training Time & Material Services Voltage Control Contact Us: US Toll Free: 866-261-1191 Phone: 937-253-1191 E-mail: sales@stacoenergy.com UPS & Emergency Lighting Power Factor & Harmonics FL-BMS-II_bro-210217-