Series 100/200 l l 0.8 to 3.0 Amperes
These manually operated panel mounted units are available in single and three phase models from 0.8 to 3.0 amperes. The 171, 201, 221-B and 291 units operate from 120 volt input, while the 252 unit operates from a 240 volt input. STACO’s coil tapping arrangement permits an output voltage from 0 to line voltage in either the clockwise or counterclockwise direction and from 0 to 10% above line voltage in the clockwise direc- tion. Two and three ganged, manually operated units are avail- able for increased single phase voltage ratings and for three phase applications. INPUT OUTPUT TERMINAL CONNECTIONS CONSTANT CONSTANT SHAFT (For increasing Voltage) PART NO. WIRING VOLTS HERTZ VOLTS CURRENT IMPEDANCE ROTATION As Viewed from Base End SCHE- NET LOAD LOAD FOR MATIC WT. MAX MAX MAX MAX VOLTAGE Input Jumper Output (Pg 8 & 9) LBS. AMPS KVA AMPS KVA INCREASE Single 120 50/60 0-120 1.75 0.21 2.2 0.26 CW 1-2 — 1-3
171 Phase CCW 1-2 — 2-3 1 2
60 0-132 1.75 0.23 – – CW 1-4 — 1-3 Single 50/60 0-240 1.75 0.42 2.2 0.53 CW 2-2 1-1 3-3 1&4 4 1/4Phase 240 CCW 1-1 2-2 3-3 Series 60 0-264 1.75 0.46 – – CW 4-4 1-1 3-3 171-2 Three 50/60 0-120 1.75 0.36 2.2 0.46 CW 2-1-2 1-1 3-1-3 Phase 120++ — — CCW 1-2-1 2-2 3-2-3 1 & 5 4 1/4Open 60 0-132 1.75 0.40 — — CW 4-1-4 1-1 3-1-3Delta π Three CW 2-2-2 1-1-1 3-3-3171-3 Phase 240++ 60 0-240 1.75 0.73 2.2 0.92 CCW 1-1-1 2-2-2 3-3-3 1 & 6 6 1/2 Wye π Single 50/60 0-120 2.0 0.24 2.5 0.30 CW 1-2 — 1-3
201 Phase 120 CCW 1-2 — 2-3 12
60 0-132 2.0 0.26 — — CW 1-4 — 1-3 Single 50/60 0-240 2.0 0.48 2.5 0.60 CW 2-2 1-1 3-3 Phase 240 CCW 1-1 2-2 3-3 1 & 4 4 1/4 Series 60 0-264 2.0 0.53 — — CW 4-4 1-1 3-3 201-2 Three 50/60 0-120 2.0 0.42 2.5 0.52 CW 2-1-2 1-1 3-1-3 Phase 120++ CCW 1-2-1 2-2 3-2-3 1 & 5 4 1/4Open 60 0-132 2.0 0.46 — — CW 4-1-4 1-1 3-1-3Delta π Three CW 2-2-2 1-1-1 3-3-3201-3 Phase 240++ 60 0-240 2.0 0.83 2.5 1.04 CCW 1-1-1 2-2-2 3-3-3 1 & 6 6 1/2 Wye π Single 50/60 0-120 2.5 0.30 3.2 0.38 CW 1-2 — 1-3 221-B Phase 120 CCW 1-2 — 2-3 1 2 1/2 60 0-132 2.5 0.33 — — CW 1-4 — 1-3 Single 50/60 0-240 2.5 0.60 3.2 0.77 CW 2-2 1-1 3-3 Phase 240 CCW 1-1 2-2 3-3 1 & 4 5 1/2 Series 60 0-264 2.5 0.66 — — CW 4-4 1-1 3-3 221-B-2 Three CW 2-1-2 1-1 3-1-3 Phase 120++ Three CW 2-2-2 1-1-1 3-3-3221-B-3 Phase 240++ 60 0-240 2.5 1.04 3.2 1.33 CCW 1-1-1 2-2-2 3-3-3 1 & 6 8 1/4 Wye π 3PN221B Single 120 60 0-132 2.50 0.33 — — CW LINE CORD & RECEPTACLE 3 3Phase Single 50/60 0-240 0.8 0.19 1.0 0.24 CW 1-2 — 1-3
252 Phase 240 CCW 1-2 — 2-3 1 2 1/2
60 0-264 0.8 0.21 — — CW 1-4 — 1-3 Single CW 2-2 1-1 3-3 Phase 480 50/60 0-480 0.8 0.38 1.0 0.48 CCW 1-1 2-2 3-3 1 & 4 5 1/2 Phase 240++ CCW 1-2-1 2-2 3-2-3 Open 60 0-264 0.8 0.37 — — CW 4-1-4 1-1 3-1-3 1 & 5 5 1/2 Delta π Three 50/60 0-480 0.8 0.67 1.0 0.83 CW 2-2-2 1-1-1 3-3-3 252-3 Phase 480++ CCW 1-1-1 2-2-2 3-3-3 1 & 6 8 1/4 Wye π 60 0-528 0.8 0.73 — — CW 4-4-4 1-1-1 3-3-3
INPUT OUTPUT TERMINAL CONNECTIONS CONSTANT CONSTANT SHAFT (For increasing Voltage) PART NO. WIRING VOLTS HERTZ VOLTS CURRENT IMPEDANCE ROTATION As Viewed from Base End SCHE- NET LOAD LOAD FOR MATIC WT. MAX MAX MAX MAX VOLTAGE Input Jumper Output (Pg 8 & 9) LBS. AMPS KVA AMPS KVA INCREASE Single 50/60 0-120 3.0 0.36 3.5 0.42 CW 1-2 — 1-3
291 Phase 120 CCW 1-2 — 2-3 1 2 1/2
60 0-132 3.0 0.40 — — CW 1-4 — 1-3 Single 50/60 0-240 3.0 0.72 3.5 0.84 CW 2-2 1-1 3-3 Phase 240 CCW 1-1 2-2 3-3 1 & 4 5 1/2 Series 60 0-264 3.0 0.79 — — CW 4-4 1-1 3-3 291-2 Three 50/60 0-120 3.0 0.62 3.5 0.73 CW 2-1-2 1-1 3-1-3 Phase 120++ CCW 1-2-1 2-2 3-2-3 1 & 5 5 1/2Open 60 0-132 3.0 0.69 — — CW 4-1-4 1-1 3-1-3Delta π Three CW 2-2-2 1-1-1 3-3-3291-3 Phase 240++ 60 0-240 3.0 1.25 3.5 1.45 CCW 1-1-1 2-2-2 3-3-3 1 & 6 8 1/4 Wye π Jumper provided in the standard common position and should be moved or removed as required. ++ Line to line voltage π If ganged units are used in a system that ordinarily has a common neutral or ground between source and load, the neutral or ground must be connected to the com- mon terminals of the variable transformer assembly. If the system has no neutral, the load must be balanced or the transformers will be damaged. 120V 240V TYPE B TYPE A 291 2.31” [58.7]